| Sl. No. | Item Description |
| 1 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 2 | Dismantling of RCC post or struts, any section and stacking for measurement including taking out embedded concrete portion and making good disturbed ground complete all as specified and directed. |
| 3 | Dismantling fencing wire mesh any type complete all as specified and directed. |
| 4 | Surface dressing not. exceeding 15cm deep in hard/ dense soil including cutting bushes, vegetations & small trees upto 30cm girth and removal of debris to distance not exc. 100 metre complete all as specified and directed. |
| 5 | Grubbing up tree trunk of girth exc 30cm and n.exc 100cm including cutting of trunk portion protruding over ground, digging out roots, filling holes and levelling off ground,stacking of serviceable material and removing of unserviceable material to a distance n exc. 50 m and clearing site complete all as specified and directed. |
| 6 | Grubbing up tree trunk of girth exc 100cm and n.exc 150cm including cutting of trunk portion protruding over ground, digging out roots, filling holes and levelling off ground, stacking of serviceable material and removing of unserviceable material to a distance n exc. 50 m and clearing site complete all as specified and directed. |
| 7 | Grubbing up tree trunk of girth exc 150cm and n.exc 200cm including cutting of trunk portion protruding over ground, digging out roots, filling holes and levelling off ground, stacking of serviceable material and removing of unserviceable material to a distance n exc. 50 m and clearing site complete all as specified and directed. |
| 8 | Grubbing up tree trunk of girth exc 200cm and n.exc 250cm including cutting of trunk portion protruding over ground, digging out roots, filling holes and levelling off ground, stacking of serviceable material and removing of unserviceable material to a distance n exc. 50 m and clearing site complete all as specified and directed. |
| 9 | Grubbing up tree trunk of girth exec 250cm and n.exc 300cm including cutting of trunk portion protruding over ground, digging out roots, filling holes and levelling off ground, stacking of serviceable material and removing of unserviceable material to a distance n exc. 50 m and clearing site complete all as specified and directed. |
| 10 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation n exc 10 sqm on plan and n exc 1.5 m depth getting out Hard/ Dense soil all as specified complete all as specified and directed. |
| 11 | Excavation in trenches not exceeding. 1.5m wide and not exceeding 1.5m in depth for foundation n exc 10 sqm on plan and n exc 1.5 m depth getting out Hard rock complete all as specified and directed. |
| 12 | Excavating over areas, n exc 1.5 m deep and getting out in Hard/ Dense soilcomplete all as specified and directed. |
| 13 | Excavating over areas, n exc 1.5 m deep and getting out in Hardrock complete all as specified and directed. |
| 14 | Excavation in trenches n exc 1.5m wide and exc 1.5m and n exc 3m in depth for foundation n exc 10 sqm on plan and n exc 1.5 m depth getting out Hard /dense soilcomplete all as specified and directed. |
| 15 | Excavation in trenches n exc 1.5m wide and exc 1.5m and n exc 3m in depth for foundation n exc 10 sqm on plan and n exc 1.5 m depth getting out Hard rockcomplete all as specified and directed. |
| 16 | Excavating over areas, exc 1.5 m deep and getting out in Hard/ Dense soil complete all as specified and directed. |
| 17 | Excavating over areas, exc 1.5 m deep and getting out Hard rock complete all as specified and directed. |
| 18 | Material and labour for plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate, in foundations, filling and mass concrete all as specified and directed. |
| 19 | Material and labour for RCC Design mix M25 grade using 20mm graded stone aggregate as in foundation including raft, footing, foundation beams, plinth beams bases of column basement slab and mass concrete all as specified and directed. (from work and reinforcement shall be measured and paid separately). |
| 20 | Material and labour for form work to sides of concrete foundations, footings, bases, of columns, rafe and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finished, flat surfaces of concrete, complete all as specified and directed. |
| 21 | Material andlabour for RCC Design mix M25 grade using 20mm graded stone aggregate as in column, pillar, piers, post and struts etc complete all as specified and directed.(Note: Form work and reinforcement shall be measured and paid separately). |
| 22 | Material and labour for formwork to sides of pillars, posts, struts, piers, columns and stanchions for fair finished, square, rectangular or polygonal flat surfaces of concrete, complete all as specified and directed. |
| 23 | Material and labour for formwork to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished, flat surfaces of concrete, complete all as specified and directed. |
| 24 | Material and labour for RCC Design mix M25 grade using 20mm graded stone aggregate as in beams, cantilevers, lintels etc. all as specified and directed. (Note:Form work and reinforcement shall be measured and paid separately). |
| 25 | Material and labour for mild steel TMT bars Fe-500 D grade 10mm dia andover, cut to length, bent to shaperequired including cranking, bending spirally for hooping for columns hooking ends and binding with and including MS wire (annealed ) not less than 0.90mm dia complete all as specified and as directed. |
| 26 | Material and labour for mild steel TMT bars Fe-500 D grade 6mm to 8mm dia andover ,cut to length, bent to shaperequired including cranking, bending spirally for hooping for columns hooking ends and binding with and including MS wire (annealed ) not less than 0.90mm dia complete all as specified and as directed. |
| 27 | Material and labour for mild steel TMT bars Fe-500 D grade 5mm dia and over upto 10mm, cutto length, bent to shape required including cranking, bending as in stirrups and binders and binding with and including MS wire (annealed) not less than 0.90 mm dia complete all as specified and as directed. |
| 28 | Material and labour for precast cement concrete block masonry with solid blocks made out of PCC 1:3:6, type C-1 with using 20mm graded stone aggregate, exceeding 10cm in width and setting in cement mortar 1:6 etc completeall as specified and as directed. |
| 29 | Material and labour for plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in coping including necessary form work and finishing the exposed surfaces complete all as specified and directed. |
| 30 | Material and Labour for rendering 15 mm thick in cement mortar 1:6 on fair faces of PCC block masonry/concrete surface finished even and Smooth without using extra cement complete all as specified and directed. |
| 31 | Material and Labour for preparing newly plastered wall surface and applying two coats of cement base paint over a coat of alkali resistiveprimer complete all as specified and directed. |
| 32 | Supply and fixing mild steel posts swan neck (Single) using angles conforming to Fe-290 Gde E-165 including cutting top to shape required, bottom with split ends embedded in concrete, drilling, welding etc. complete all as specified and directed. (Note: Concrete for embedding / fixing shall be measured and paid separately.) |
| 33 | Material and labour for preparation of new untreated steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 34 | Returning filling, including spreading, levelling, watering and well ramming in layers n.exc. 25cm complete all as specified and directed. |
| 35 | Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed at a level n. exc. 1.5 m above starting point complete all as specified and directed . |
| 36 | Supply and fix galvanized two strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing any type of standard rail straining bolts including securing or tying at crossing with and provision of galvanized MS steel wire with staples or steel pins complete all as specified and directed. |
| 37 | Supply and fix framed work such as grills gratings etc with ends of bars shouldered and / or riveted or forged into spikes framed guard bars barred iron doors ladders framed balusters walk ways railings frame work of water tanks and similar work confirming to Fe 290 Gde E 165 complete all as specified and directed. |
| 38 | Supply and fix PVC (SWR) pipes single socketed 110 mm bore in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 39 | Excavating in post holes (or similar holes) in any Soft/loose soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed. |
| 40 | Excavating in post holes (or similar holes) in Hard rock each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,complete all as specified and directed. |
| 41 | Material and Labour for PCC 1:3:6 type C2 using 40 mm graded stone aggregate in foundation complete all as specified and directed. |
| 42 | Supply and fixmild steel sections of any description conforming to grade E 165 fixed as in posts and struts in fencing, including flat iron fillets for security wire mesh etc with all necessary drilling holes, bolting or riveting etc. complete all as specified and as directed |
| 43 | Supply only chain link MS galvanised fencing, 50x50 mm mesh or as specified of 3.8mm dia or more wire including line wires as approved by GE complete all as specified and directed. |
| 44 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standard, rails straining bolts etc including provision for binding wire complete all as specified and directed. |
| 45 | Supply and fix MS round bars conforming to Grade E-250 quality A, 10 mm dia cut to length bent to shape required and fixing as directed in fencing complete all as specified and directed |
| 46 | Supply and fix mild steel screw bolts n exc 5 cm long of 11 mm to 15 mm diameter (machine made) with hexagonal or square heads at one screwed the other each screwed end to be fitted with washers and one hexagonal or square nut complete all as specified and directed |
| 47 | Material and Labour for preparation of new or steel surfaces of any description n exc 10 cm width or girth, not otherwise described any applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 48 | Material and Labour framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete to Fe-410-w (Grade-E-250) quality B complete all as specified and directed. |
| 49 | Excavation in trenches not exceeding. 1.5m wide and not exceeding 1.5m in depth for foundation n exc 10 sqm on plan and n exc 1.5 m depth getting out Soft/ loose soil complete all as specified and directed. |
| 50 | Excavation in trenches not exceeding. 1.5m wide and exceeding 1.5m and n exc 3m in depth for foundation n exc 10 sqm on plan and n exc 1.5 m depth getting out Soft/ loose soil complete all as specified and directed. |
| 51 | Material and Labourfor rendering 15mmthickCM 1:6 onfair faces of brick work or concrete surfaces complete all as specified and directed. |
| 52 | Removingexcavated material to a distance not exc.50m and depositing where directed at a level not exc.1.5m above the starting pointcomplete all as specified and directed. |
| 53 | Earth work in excavation by mechanical means (Hydraulic excavator) in any kind of soil means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m,complete all as specified and directed. |
| 54 | Material and LabourReinforced cement concrete (design mix) M-25 using 20 mm graded stone aggregates as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed. |
| 55 | Material and Labour use and waste of timber as in formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, for fair finished surfaces of concrete flat complete all as specified and directed. |
| 56 | Material and Labour use and waste of timber as in formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pilasters, buttresses, etc.; vertical or to batter, for fair finished surfaces of concrete flat complete all as specified and directed. |
| 57 | Supply and fix PVC (SWR) pipes single socketed 75 mm bore in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 58 | Supply and fix Hand packing broken stone aggregate (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level complete all as specified and directed. |
| 59 | Spreading and levelling with approved soil obtained from excavation in layers n exc. 25 cm thick, well ramming including watering as required complete all as specified and directed. |
| 60 | Material and Labour forpreparing new surfaces of walls and applying cement wash with Portland cement slurry 02 coats to a smooth bodied opaque finish complete all as specified and directed. |
| 61 | Supply and fix for 12 mm thick pre-formed filler for expansion joint complete all as specified and directed. |
| 62 | Material and Labour for hardcore ofbroken stone are boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered andrammed to a true surface complete all as specified and directed. |
| 63 | Material and Labour for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 64 | Material and Labour formachine pressed precast concrete interlocking paver block with grey cement and no pigmentany shape and size of confirming to IS 15658-2006 of 80 mm thickness M-40 Grade complete all as specified and directed. |
| 65 | Material and Labourfor PCC 1:5:10 type E-2 using 40 mm graded stone aggregate in foundations, filling and mass concrete etc complete all as specified and directed. |
| 66 | Material and Labour forPCC 1:2:4, type B-1 using 20 mm graded stone aggregate as in coping sides of paver block complete all as specified and directed |
| 67 | Material and Labour Reinforced concrete pipes, class NP3 300mm dia, laid in trench & in manhole and jointedwith collars complete all as specified and directed. |
| 68 | Material and Labour for 1: 4 : 8 D2 Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested all as specified and directed. |
| 69 | Supply and installation of copper wound transformer, level - 3, step down,indoor/outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:2026 of capacity of 100 KVA complete all as specified and directed. |
| 70 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sqmm complete all as specified and directed. |
| 71 | Supplying and laying un-reinforced precast concrete cable cover class HV, Type 1, flat, size 300mmx180mm x 40mm complete all as specified and directed. |
| 72 | Supply and fix cable jointing kit for 11 KV grade cable for out door termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 Sqmm complete all as specified and directed. |
| 73 | Supply and fix cable jointing kit for 11 KV grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 50 Sqmm to 95 sqmm, Indoor/Outdoor type complete all as specified and directed. |
| 74 | Supply and install steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified type 410SP-55 (11.0 meter long) and including painting with two coats of aluminium paint over one coat of red oxide and black bituminous paint on the hidden surface in foundation including drilling of holes for fixing of D Iron clamp and holes for continuous GI earth wire as requiredcomplete all as specified and directed. |
| 75 | Material and Labour for Cross arms, bracings, supports, Anti climbing device, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including Dismantling of cross arms of MS channel or angle sections etccomplete all as specified and directed. |
| 76 | Supply andfixAir Break, Gang operated Triple pole switches/device , mechanically operated, mounted on insulator and steel frame,with operating mechanismof GI tubing 25 mm suitable length worked from ground levelincluding locking accessories complete for current rating up to 400 Amps11000 Volts complete with 12 insulatorscomplete all as specified and directed. |
| 77 | Supply and fix Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, suitable for 11000 Volts complete all as specified and directed. |
| 78 | Material and Labour for Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundation of steel poles/struts as specified including necessary form work all as specified and as directed. |
| 79 | Material and labour for PCC 1:2:4 type B-1 using 20mm graded stone aggregate for making good of road finished fair and even and pole coping complete all as specified and directed. |
| 80 | Supply and fix steel tubular swaged poles type 410 SP-22 (9.0 meter long) complete with CI base plate and finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (9 metres long)complete with CI base. complete all as specified and directed. |
| 81 | Supply and fix LED street light 90 W, 230 V AC outdoor type with thermal management in multiple optics and equipped with IP 65 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 82 | Supply and fixing street light bracket made out of 40 mm bore mild steel GI light grade tubing overall length 1.5 mtr bend to shape as directed including providing two nos MS flat iron 40x6m clamp of appropriate size with nut bolts and washer duly painted two coats of enamel paint over a coat of primer complete all as specified and directed. |
| 83 | Supply, laying, jointing and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sqmm 4 core complete all as specified and directed. |
| 84 | All as per item No. 83.00 above but of size 25 sqmm 4 core complete all as specified and directed. |
| 85 | All as per item No.83.00above but of size 50 sqmm 3.5 core complete all as specified and directed. |
| 86 | All as per item No.83.00above but of size 70 sqmm 3.5 core complete all as specified and directed. |
| 87 | Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in soft/loose soil for laying of under ground cable and foundation of poles.etc complete all as specified and directed. |
| 88 | Returning filling in including spreading, levelling watering and well ramming in layers not exceeding 25 cmthick .etc complete all as specified and directed. |
| 89 | Removal of excavated surplus soil not exceeding 50 m and depositing where directed at al level not exceeding 1.5 m above the starting pointcomplete all as specified and directed. |
| 90 | Supply and spreading clean dry riddled sand in trenches for cushioning all as specified for cable protection in trenches / ducts complete all as directed. (Note: The punned down thickness shall be measured and paid.) |
| 91 | Supplying and laying reinforced precast concrete cable cover,Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed. |
| 92 | Supply and fix sub main wiring with using two runs of 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed (FRLS) cable and one run of 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed (FRLS) as earth wire using ISI marked IS 694 1100 Volts grade PVC insulated flexible stranded copper conductor wire drawn through with and including medium grade PVC conduit of size not less than 25mm dia ISI marked of suitable size including conduit fitting and accessories, including end termination with bottle type copper lugs conduit being laid either in ceiling slab or wall or on surfaces or under the frame of the false ceiling including PVC flexible conduit or through wooden partition including clamping arrangement as required complete all as specified and directed.Note: Two runs of 1.5 Sqmm cable and one run of 1.5 Sqmm earth wire and conduit of suitable size shall be measured as one unit |
| 93 | Supply and fix hot press moulded SMC junction/terminal box of size with internal dimensions of 255 x 355 x 122 mm with hinged door, including provision of 2 way connector 415 volts made out of polycarbonate or bakelite and 1 no MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable size of cable lugs/glands, fixed on pole by means of clamps made out of MS flat ironof size 25mm x 3 mm (two set) complete all as specified and directed. |
| 94 | Supply, install, testing and commissioning of factory made LT Busbar box, CPRI approved, outdoor type, 1.1KV made out of MS CRCA sheet 3.15 mm thick, having 4 Nos Aluminium bus bar of size 200 Amps for phase 100 Amps for neutral fixed on LT, 8 Nos insulators of size 0.60M x 0.45 M with legs made out of MS angle 50x50x5mm & 0.75mtr in length, locking arrangementsfront and back opening danger notice board with skull & bone monogram and indicating 1100 volt danger board including incoming and outgoing connections and testing on completion complete all as specified and directed. |
| 95 | Supply, install, testing and commissioning of factory made CPRI approved LT panel board (Panel No. 1) 415 Volts, 50 Hz, 100 Amps capacityoutdoor cubical type LT distribution switch gear and control gear, legmounted, totally enclosed, cubical type modular compartment , dust and vermin proof IP-54 with neoprene gasket, fabricated out of CRCA sheet of thick ness not less than 3.15 mm complete with 2 mm thick for internal compartmentduly powdercoated fixed on angle iron pedestal made out of 50x50x6mm with cable chamber for incoming outgoing connections comprising for the following including necessary PCC foundation of minimum 0.20 Mtr height positioned and fixed with suitable nut, bolts, washers etc to the pedestal and connecting all incoming and outgoing cables all as specified and directed with the following details:- |
| 96 | (a) AluminiumBus bar four wire system 415 volts mounted on porcelain heat shrinkableinsulator & sleeve suitable for 200 A for phases and 100 Amps for neutral . b) LED type Indicating lamps for all the three phase with different colour lamp red, yellow and green.- 1 set c) Digital multi function panel meter measuring voltage, Amps and frequency with suitable CTs and backup protection - 1 Nos d) Danger notice board of size 200 MMX150mmX 1.6 mm thick of mild steel sheet with vitreous enamelled white and letter figure and convention skull and bones of signal red colour and fixed/riveted with panel- 02 Nos b) Incoming - MCCB 4 pole 63 Amp 25 KA - 01No. c) OutgoingMCCB 4 pole 32 Amp 25 KA -02 NosMCB TPN 10 Amp - 03 Nos MCB SPN 10 Amp -01 NosTime switches 415 V three Phase of 20 Amp rating with contactor - 01 Nos |
| 97 | Supply, install, testing and commissioning of factory made CPRI approved LT panel board (LT panel No. 2, 6 & 5 ) 415 Volts, 50 Hz, 100 Amps capacityoutdoor cubical type LT distribution switch gear and control gear, legmounted, totally enclosed, cubical type modular compartment , dust and vermin proof IP-54 with neoprene gasket, fabricated out of CRCA sheet of thick ness not less than 3.15 mm complete with 2 mm thick for internal compartmentduly powdercoated fixed on angle iron pedestal made out of 50x50x6mm with cable chamber for incoming outgoing connections comprising for the following including necessary PCC foundation of minimum 0.20 Mtr height positioned and fixed with suitable nut, bolts, washers etc to the pedestal and connecting all incoming and outgoing cables all as specified and directed with the following details:- |
| 98 | (a) AluminiumBus bar four wire system 415 volts mounted on porcelain heat shrinkableinsulator & sleeve suitable for 200 A for phases and 100 Amps for neutral . b) LED type Indicating lamps for all the three phase with different colour lamp red, yellow and green.- 1 set c) Digital multi function panel meter measuring voltage, Amps and frequency with suitable CTs and backup protection - 1 Nos d) Danger notice board of size 200 MMX150mmX 1.6 mm thick of mild steel sheet with vitreous enamelled white and letter figure and convention skull and bones of signal red colour and fixed/riveted with panel- 02 Nos a) Incoming - MCCB 4 pole 32 Amp 25 KA - 01 No. b) OutgoingMCB TPN 10 Amp - 03 No.MCC SPN 10 Amp - 01 No.Time switches 415 V three Phase of 20 Amp rating with contactor - 01 No |
| 99 | Supply, install, testing and commissioning of factory made CPRI approved LT panel board (LT Panel No. 4)415 Volts, 50 Hz, 100 Amps capacityoutdoor cubical type LT distribution switch gear and control gear, legmounted, totally enclosed, cubical type modular compartment , dust and vermin proof IP-54 with neoprene gasket, fabricated out of CRCA sheet of thick ness not less than 3.15 mm complete with 2 mm thick for internal compartmentduly powdercoated fixed on angle iron pedestal made out of 50x50x6mm with cable chamber for incoming outgoing connections comprising for the following including necessary PCC foundation of minimum 0.20 Mtr height positioned and fixed with suitable nut, bolts, washers etc to the pedestal and connecting all incoming and outgoing cables all as specified and directed with the following details:- |
| 100 | (a) AluminiumBus bar four wire system 415 volts mounted on porcelain heat shrinkableinsulator & sleeve suitable for 200 A for phases and 100 Amps for neutral . b) LED type Indicating lamps for all the three phase with different colour lamp red,yellow and green.- 1 set c) Digital multi function panel meter measuring voltage, Amps and frequency with suitable CTs and backup protection - 1 No. d) Danger notice board of size 200 MMX150mmX 1.6 mm thick of mild steel sheet with vitreous enamelled white and letter figure and convention skull and bones of signal red colour and fixed/riveted with panel- 02 Nos. b) Incoming - MCCB 4 pole 100 Amp 25 KA - 01 No c) OutgoingMCCB 4 pole 32 Amp 25 KA -03 Nos.MCB TPN 16 Amp - 03 Nos.MCB SPN 16 Amp -01 Nos. Time switches 415 V three Phase of 20 Amp rating with contactor - 01 No. |
| 101 | Supply, install, testing and commissioning of factory made CPRI approved LT panel board (LT Panel No. 3)415 Volts, 50 Hz, 100 Amps capacityoutdoor cubical type LT distribution switch gear and control gear, legmounted, totally enclosed, cubical type modular compartment , dust and vermin proof IP-54 with neoprene gasket, fabricated out of CRCA sheet of thick ness not less than 3.15 mm complete with 2 mm thick for internal compartmentduly powdercoated fixed on angle iron pedestal made out of 50x50x6mm with cable chamber for incoming outgoing connections comprising for the following including necessary PCC foundation of minimum 0.20 Mtr height positioned and fixed with suitable nut, bolts, washers etc to the pedestal and connecting all incoming and outgoing cables all as specified and directed with the following details:- |
| 102 | (a) AluminiumBus bar four wire system 415 volts mounted on porcelain heat shrinkableinsulator & sleeve suitable for 200 A for phases and 100 Amps for neutral . b) LED type Indicating lamps for all the three phase with different colour lamp red, yellow and green.- 1 set c) Digital multi function panel meter measuring voltage, Amps and frequency with suitable CTs and backup protection - 1 Nos d) Danger notice board of size 200 MMX150mmX 1.6 mm thick of mild steel sheet with vitreous enamelled white and letter figure and convention skull and bones of signal red colour and fixed/revited with panel- 02 Nos b) Incoming - MCCB 4 pole 63 Amp 25 KA - 01 No.c) OutgoingMCCB 4 pole 32 Amp 25 KA -03 Nos. MCB TPN 16 Amp - 03 Nos.MCB SPN 16 Amp -01 No.Time switches 415 V three Phase of 20 Amp rating with contactor - 01 No. |
| 103 | M&L for earthing complete with galvanised steel earth plate electrode 60 × 60 cm × 6 mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed |
| 104 | M&L for earthing of machinery/equipment Installed at power house /sub station, using 32 x 6 mm galvanized MS strip and MS galvanized plate of size 600 x 600 x 6 mm ,as earth electrode complete all as specified and directed |
| 105 | Supplying, Installing, testing and commissioning, factory assembled silent Diesel Engine driven generator set as per CPCB IV norms, fully wired alternator to give an out put of 20 kVA continuously raing at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz + 1% supply, directly coupled with diesel engine, liquid cooled of of suitable BHP de-rated for Wellington, Nilgiris at high altitude of approximate 2000 Mtr mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line and accessories, PCC foundation work as per manufacture\"s instructions, vibration damper pads, AMF control panel, Battery& other accessories etc and comprising of following :-(a) Diesel Engine liquid cooled, turbocharged with after coler to deliver required BHP a under NTP condition ofBS 5514 standard de-rated for Wellington, Nilgiris at high altitude of approximate 2000 Mtr and conforming to IS 10001/10002 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories.(i)Dry type air cleaner(ii) Exhaust Silence suitable for canopy(iii)Expansion bellow(iv) Lube oil Cooler(v)Fuel Filters |
| 106 | (vi) Radiator with pusher type fan and mounting(vii)In-line mono block fuel injection pump(viii)Mechanical governor and fuel feed pump(ix) Fly wheel with starter ring and bell bousing suitable for close coupling(x) 12 Volt electric starter motor(xi) Battery charging alternator(xii) Microprocessor based KG934(L1) Controller mounted are fixed in power panel(xiii) Protection system for Low lube oil pressure and High water temperature(xiv) Battery:- Suitable Maintenance free battery with leads & terminals as per OEM recommendation (Make- Exide/Amron) (xv) Fuel tank:08 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator, fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling from exterior canopy (without opening its panel) etc complete all as specified and directed. |
| 107 | (b) Alternator suitable rated at 20 kVA at 0.8 power factor , 415 volts, 3 phase, 4 wire, 50 Hz atself excited and self regulated with AVR brushless excitation, screen protected, drip proof , insulation class H,self ventilated, floor mounted with ball or bearing on end shields and conforming to IS: 4722 suitable for engine as mentioned here-in before.(c) Acoustic Enclosure:- Acoustic enclosure with outer body made of 3.15mm thick CRCA sheet , epoxy coated and sound insulation to reduce noise level to 75 dBA measured at 1.0 meter average distance for audible frequencies as per guide of Central Pollution Control Board or latest CPCB norms and of suitable size and OEM specification and inside illumination with 1 No. 1 x 18 watt LED fitting .(d)Standard Gen set Controller with Control Panel -Gen Set controller unit totally enclosed, steel construction control panel suitable for indoor floor/ wall mounting installation with control fuse base with necessary link, power terminals and control terminal start and stop relayhaving following safeties and display parameters :- |
| 108 | (i) Engine display Parameter for :-(aa) Oil Pressure(ab) Engine Coolant Temperature(ac) Fuel Status(ad) Engine Speed(ae)Battery Voltage(af) Engine Hours (ii) Mechanical Safeties (along with Display) for :-(aa)Under / Over Speed(ab)Low lube oil Pressure(ac)High Engine coolant Temperature (iii) Gen-Set Display parameter for :-(aa)Phase Voltage(ab)Line Current(ac)Frequency & PF(ad)Average Voltage(ae)Average Current(af) Phase KW and Total KW(ag)KWH(ah)KVA & KVAR (iv) Electrical Safety (along with display ) parameter for :-(aa) Genset under / over voltage(ab) Under / Over Frequency(ac) Phase Failure(ad) Phase sequence reverse(ae) Over Current(af)Over KW |
| 109 | (e) Civil works:- All civil works related to foundation, installation of panel and equipment & depth of foundation shall be minimum 300mm with anti vibration pads, or as recommended by manufacturers is included in the quoted rate. Cable from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule |
| 110 | Supplying, Installing, testing and commissioning, factory assembled silent Diesel Engine driven generator set as per CPCB IV norms, fully wired alternator to give an out put of 15 kVA continuously raing at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz + 1% supply, directly coupled with diesel engine, liquid cooled of of suitable BHP de-rated for Wellington, Nilgiris at high altitude of approximate 2000 Mtr mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line and accessories, PCC foundation work as per manufacture\"s instructions, vibration damper pads, AMF control panel, Battery& other accessories etc and comprising of following :-(a) Diesel Engine liquid cooled, turbocharged with after coloer to deliver required BHP a under NTP condition ofBS 5514 standard de-rated for Wellington, Nilgiris at high altitude of approximate 2000 Mtr and conforming to IS 10001/10002 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories. |
| 111 | (i)Dry type air cleaner(ii) Exhaust Silence suitable for canopy(iii)Expansion bellow(iv) Lube oil Cooler(v)Fuel Filters(vi) Radiator with pusher type fan and mounting(vii)In-line mono block fuel injection pump(viii)Mechanical governor and fuel feed pump(ix) Fly wheel with starter ring and bell bousing suitable for close coupling(x) 12 Volt electric starter motor(xi) Battery charging alternator(xii) Microprocessor based KG934(L1) Controller mounted are fixed in power panel(xiii) Protection system for Low lube oil pressure and High water temperature(xiv) Battery:- Suitable Maintenance free battery with leads & terminals as per OEM recommendation (Make- Exide/Amron) (xv) Fuel tank:08 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator, fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling from exterior canopy (without opening its panel) etc complete all as specified and directed. |
| 112 | (b) Alternator suitable rated at 15 kVA at 0.8 power factor , 415 volts, 3 phase, 4 wire, 50 Hz atself excited and self regulated with AVR brushless excitation, screen protected, drip proof , insulation class H,self ventilated, floor mounted with ball or bearing on end shields and conforming to IS: 4722 suitable for engine as mentioned here-in before. Make- Kirloskar /STAMFORD/ Crompton.(c) Acoustic Enclosure:- Acoustic enclosure with outer body made of 3.15mm thick CRCA sheet , epoxy coated and sound insulation to reduce noise level to 75 dBA measured at 1.0 meter average distance for audible frequencies as per guide of Central Pollution Control Board or latest CPCB norms and of suitable size and OEM specification and inside illumination with 1 No. 1 x 18 watt LED fitting of make Phillips/ Bajaj/ Crompton.(d)Standard Gen set Controller with Control Panel -Gen Set controller unit totally enclosed, steel construction control panel suitable for indoor floor/ wall mounting installation with control fuse base with necessary link, power terminals and control terminal start and stop relayhaving following safeties and display parameters :- |
| 113 | (i) Engine display Parameter for :-(aa) Oil Pressure(ab) Engine Coolant Temperature(ac) Fuel Status(ad) Engine Speed(ae)Battery Voltage(af) Engine Hours (ii) Mechanical Safeties (along with Display) for :-(aa)Under / Over Speed(ab)Low lube oil Pressure(ac)High Engine coolant Temperature (iii) Gen-Set Display parameter for :-(aa)Phase Voltage(ab)Line Current(ac)Frequency & PF(ad)Average Voltage(ae)Average Current(af) Phase KW and Total KW(ag)KWH(ah)KVA & KVAR (iv) Electrical Safety (along with display ) parameter for :-(aa) Genset under / over voltage(ab) Under / Over Frequency(ac) Phase Failure(ad) Phase sequence reverse(ae) Over Current(af)Over KW |
| 114 | (e) Civil works:- All civil works related to foundation, installation of panel and equipment & depth of foundation shall be minimum 300mm with anti vibration pads, or as recommended by manufacturers is included in the quoted rate. Cable from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule. |
| 115 | Supplying, Installing, testing and commissioning, factory assembled silent Diesel Engine driven generator set as per CPCB IV norms, fully wired alternator to give an out put of 10 kVA continuously raing at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz + 1% supply, directly coupled with diesel engine, liquid cooled of of suitable BHP de-rated for Wellington, Nilgiris at high altitude of approximate 2000 Mtr mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line and accessories, PCC foundation work as per manufacture\"s instructions, vibration damper pads, AMF control panel, Battery& other accessories etc and comprising of following :-(a) Diesel Engine liquid cooled, turbocharged with after cooler to deliver required BHP a under NTP condition ofBS 5514 standard de-rated for Wellington, Nilgiris at high altitude of approximate 2000 Mtr and conforming to IS 10001/10002 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories.Make : Kirloskar /Cummins/Greaves Cotton |
| 116 | (i)Dry type air cleaner(ii) Exhaust Silence suitable for canopy(iii)Expansion bellow(iv) Lube oil Cooler(v)Fuel Filters(vi) Radiator with pusher type fan and mounting(vii)In-line mono block fuel injection pump(viii)Mechanical governor and fuel feed pump(ix) Fly wheel with starter ring and bell bousing suitable for close coupling(x) 12 Volt electric starter motor(xi) Battery charging alternator(xii) Microprocessor based KG934(L1) Controller mounted are fixed in power panel(xiii) Protection system for Low lube oil pressure and High water temperature(xiv) Battery:- Suitable Maintenance free battery with leads & terminals as per OEM recommendation (Make- Exide/Amron) (xv) Fuel tank:08 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator, fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling from exterior canopy (without opening its panel) etc complete all as specified and directed. |
| 117 | (b) Alternator suitable rated at 10 kVA at 0.8 power factor , 415 volts, 3 phase, 4 wire, 50 Hz atself excited and self regulated with AVR brushless excitation, screen protected, drip proof , insulation class H,self ventilated, floor mounted with ball or bearing on end shields and conforming to IS: 4722 suitable for engine as mentioned here-in before. (c) Acoustic Enclosure:- Acoustic enclosure with outer body made of 3.15mm thick CRCA sheet , epoxy coated and sound insulation to reduce noise level to 75 dBA measured at 1.0 meter average distance for audible frequencies as per guide of Central Pollution Control Board or latest CPCB norms and of suitable size and OEM specification and inside illumination with 1 No. 1 x 18 watt LED fitting .(d)Standard Gen set Controller with Control Panel -Gen Set controller unit totally enclosed, steel construction control panel suitable for indoor floor/ wall mounting installation with control fuse base with necessary link, power terminals and control terminal start and stop relayhaving following safeties and display parameters :- |
| 118 | (i) Engine display Parameter for :-(aa) Oil Pressure(ab) Engine Coolant Temperature(ac) Fuel Status(ad) Engine Speed(ae)Battery Voltage(af) Engine Hours (ii) Mechanical Safeties (along with Display) for :-(aa)Under / Over Speed(ab)Low lube oil Pressure(ac)High Engine coolant Temperature (iii) Gen-Set Display parameter for :-(aa)Phase Voltage(ab)Line Current(ac)Frequency & PF(ad)Average Voltage(ae)Average Current(af) Phase KW and Total KW(ag)KWH(ah)KVA & KVAR (iv) Electrical Safety (along with display ) parameter for :-(aa) Genset under / over voltage(ab) Under / Over Frequency(ac) Phase Failure(ad) Phase sequence reverse(ae) Over Current(af)Over KW |
| 119 | (e) Civil works:- All civil works related to foundation, installation of panel and equipment & depth of foundation shall be minimum 300mm with anti vibration pads, or as recommended by manufacturers is included in the quoted rate. Cable from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule. |
| 120 | Material and Labour for earthing complete with galvanized steel plate earth electrode 60 cm x 60 cm x 6 mm thick thick surrounded by char coal and saltburried directly in ground vertically in pit of depth not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 m below the normal ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected togalvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanised iron steel and connected to earthing test point including all earth work , earth lead protection light grade GI pipe of 15 mm dia, light grade GI pipe of 20 mm dia for watering with funnel , wire mess, PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical plate No 3 of SSR Part-I including testing complete all as specified and directed. Note : (i) If earthing resistance not obtained less than 2 ohm then re-earthing or any other work shall be done by contractor without any additional cost complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail