Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | 34W/MW-07/2025-26: PROVN OF E/M WORKS SERVICES(E/M PORTION) |
| 2 | Supply, laying, jointing and testing XLPE armoured heavy duty electric able with aluminium conductor 1100 volts grade of size 35 Sq mm 3.5 Core, complete all as specified and directed by Engineer in Charge. |
| 3 | Supply, laying, jointing and testing XLPE armoured heavy duty electric able with aluminium conductor 1100 volts grade of size 10 Sq mm 4 Core, complete all as specified and directed by Engineer in Charge. |
| 4 | M&L for excavation in trenches not exc. 1.5 m wide and notexceeding 1.5m depth for foundation of poles/laying of cables/stay/strut etc not exceeding 10 Sq m on planand getting out in soft/loose soil, complete all as specified and directed by Engineer in Charge. |
| 5 | M&L for Returning,filling including spreading, levelling watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed by Engineer in Charge. |
| 6 | M&L for Removing excavated material (soil) n.exc 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed by Engineer in Charge. |
| 7 | M&L for providing river sand as in sand cushioning to under ground cable including punning down of sand in layers, complete all as specified and directed by Engineer in Charge. |
| 8 | M&L for brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm, complete all as specified and directed by Engineer in Charge. |
| 9 | S&F factory madeSheet metal enclosure of 3.15 mm thick sheet of outdoor type platform or wall mounted including three phase aluminium bus bar of rating 200 amps, complete all as specified and directed by Engineer in Charge. |
| 10 | S&F factory madeSheet metal enclosure of 3.15 mm thick sheet of outdoor type platform or wall mounted including three phase aluminium bus bar of rating 200 amps with MCCB 4 POLE 63 Amps, complete all as specified and directed by Engineer in Charge. |
| 11 | Supply, installing testing and commissioning of factory made and tested(Including CPRI test citified) outdoortype floor mountedLTpanel board with top canopy , cubical type suitable for 415 Volts 3 phase, 4 wire 50Hz, Ac supply system having busbar chamber with insulated AL busbar of rating 1.5 times the incomer MCCB for phaseinstalled on porcelain/SMC insulators. The panel shall be dust and vermin proof IP-64 class protection and made out of 3.15 mm thickCRCA MS sheet and angle iron frame 40x 40x 6mm thick frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front and back opening type with approaches for cable entry with double door shutter and locking arrangementsincluding internal wiring with PVC insulated stranded copper conductor cable FRLS IS 694 sheathed 1100V grade of appropriate size comprising of following :-INCOMING-(i) Mains MCCB 4 pole 125 Amps 50 KA with adjustable setting, 415 Volts with breaking capacity 16 KA -01 No.(ii) Digital type voltmeter 0-500 volts and with selector switch-01 No.(iii) Digital Amp meterwith CTs & built in selector switch-01 No.(iv) Indication lamp RYB-01 Set.OUTGOING-(i) MCCB 4 pole 63 Amps, 415 Volts with breaking capacity 16 KA-02 No.(ii) MCB 4 pole 40 Amps , 415 Volt with breaking capacity 10 KA-02 |
| 12 | 34W/MW/06/2025-26: PROVN OF EXHAUST FANS AT OFFICER\"S MESS, SNCOs MESS, AIRMEN MESS AND DSC MESS(E/M PORTION) |
| 13 | M&L for point wiring light point/ bell point with single core PVC insulated FRLS unsheathed 1100 volt grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through in concealed conduit, fixed on wall, ceiling with GI saddles GI screws, rawal plugs (concealed conduit wiring) with all fittings including Tee, junction boxes and prvn of modular metal flush boxof suitable sizemodular white cover plate with frame for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) for following:-.NOTE:- After rewiring cutting chasing portion should be matched with existing finishes of walls. (a) One light/fan/bell point controlled by one switch 6 amp one way |
| 14 | S&F of 5 Star rated BLDC exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers, complete all as specified and directed by Engineer in Charge. |
| 15 | S&F of 5 Star rated BLDC exhaust fan, steel body AC single Phase. 230V of size 380mm sweep with, blades, and frame and louvers, complete all as specified and directed by Engineer in Charge. |
| 16 | S&F of ceiling rose 65 x 17 mm three terminals, complete all as specified and directed by Engineer in Charge. |
| 17 | S&F of switch piano flush type single pole, one way 6amp . |
| 18 | M&L for making bore/ hole of dia. Suitable for fixing exhaust fan of size upto 380 mm sweep and making good the disturbed surface to match the existing plaster and paint, complete all as specified and directed by Engineer in Charge. |
| 19 | 34W/MW/01/2025-26: PROVN OF QTY-02 ACs FOR HYDRAULIC LAB(E/M PORTION) |
| 20 | Supply and install hi wall split units indoor/ outdoor complete with cordless remote control unit and with in built Heating and Cooling arrangement and Digital Inverter twin rotary type, minimum 5 Star rating of 1.5 TR capacity with powder coated MS bracket for mounting of outdoor unit, complete all as specified and directed by Engineer in Charge. |
| 21 | M&L for sub main wiring with 2 run of 4 Sqmm single core PVC insulated unsheathed FRLS cable 1100 Volts grade multistranded with copper conductor drawn through and including non metallic rigid PVC conduit ISI marked 25 mm dia including conduit accessories concealed/surface type on walls roof, floors etc including one run of 4.0 Sqmm PVC copper conductor as earth continuity wire including taking down unserviceable sub main wiring including conduit from MCB SPN to AC box, complete all as specified and directed by Engineer in Charge.Note:- 2 Runs of 4 sqmm cable 1 run of 4 sqmm cable and 1 run of PVC conduit shall be measured as one unit for the of payment. |
| 22 | S&F of metallic AC earth plug and socket with sheet metal enclosure with MCB SP 20A to 32 A complete all as directed |
| 23 | S&F of voltage stabilizer for Automatic operation with digital display of IP & OP voltage, copper wound single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy if +/-(2.5)% and of capacity 4 KVA, with low and high voltage cut-off protection, protect equipment from potentially danger voltage , built in thermal temperature burnout with latest IC technology and assories, complete all as specified and directed by Engineer in Charge. |
| 24 | S&F of amp rating 240V, 10KA C\" curve miniature circuit breaker (MCB) SPN 32Amps and current carrying capacity in the MCB DB complete with connection testing and commissioning in existing MCB DB, complete all as specified and directed by Engineer in Charge. |
| 25 | 34W/MW-02/2025-26: PROVN OF FLAME PROOF EXHAUST FAN QTY-03 ALONGWITH FLAME PROOF WIRING IN FOL BUILDING (P-950)(E/M PORTION) |
| 26 | M&L for concealed point wiring using approved colour codeing as per IS with halogen free flame retardant (HFFR) smoke free non toxic,non corrosive with copper cable 1.5 sqmm confirming to IS : 694 nominal area single core insulated and unsheathed stranded cable 1100 volt grade and including 20 mm dia. ERW stove enamelled concealed conduit heavy duty ISI marked and unsheathed copper conductor 1.5 sqmm area as earth wire as earth continuity conductor, complete all as specified and directed by Engineer in Charge. |
| 27 | S&Fof flame proof switchsocket and plug combined in LM^ cable termination box in LM6 , 16A, 250V, 2 P+Earth, complete all as specified and directed by Engineer in Charge. |
| 28 | S&F of Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V, complete all as specified and directed by Engineer in Charge. |
| 29 | S&F of ceiling rose 240V, 3 phase/PVC/polycarbonate isolated body, complete all as specified and directed by Engineer in Charge. |
| 30 | S&F of flame proof exhaust fans of size 380 mmsingle phase AC supply complete and fixing arrangement etc complete with all accessories prewired andincluding connecting up with twin core twisted flexible copper cableFRLS of suitable size incl making hole for fixing of exhaust fan of suitable size and making good disturbed surfaces, complete all as specified and directed by Engineer in Charge. |
| 31 | S&F of flame proof Wall mounting fans of size 400 mmsingle phase AC supply complete and fixing arrangement etc complete with all accessories prewired andincluding connecting up with twin core twisted flexible copper cableFRLS of suitable size incl making hole for fixing of exhaust fan of suitable size and making good disturbed surfaces, complete all as specified and directed by Engineer in Charge.Note- Removing materials to be hand over AGE E/M store for safe custody |
| 32 | S&F of LED light fitting 2x 16 watt flame proof ,CMRI certified for gas /vapour group of IIa & IIIB , Zone 1 & 2and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixtures driver , holders, connectors etc complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified and directed by Engineer in Charge. |
| 33 | S&F of single phase 220/240 VoltFlameproof Distribution Board 4 way with suitable aluminium bus bar complete with all accessories, complete all as specified and directed by Engineer in Charge. |
| 34 | Supply, laying, jointing and testing in replacement XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 6 Sq mm 2 Core with aluminium thimble of same size, complete all as specified and directed by Engineer in Charge. |
| 35 | Excavation in trenches not exc. 1.5 m wide and notexceeding 1.5m depth for foundation of poles/laying of cables/stay/strut etc not exceeding 10 Sq m on planand getting out in soft/loose soil, complete all as specified and directed by Engineer in Charge. |
| 36 | Returning,filling including spreading, levelling watering and well ramming in layers not exceeding 25 cm as directed, complete all as specified and directed by Engineer in Charge. |
| 37 | Removing excavated material (soil) n.exc 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed by Engineer in Charge. |
| 38 | M&L for river sand as in sand cushioning to under ground cable including punning down of thickness 180mm sand in layers, complete all as specified and directed by Engineer in Charge. |
| 39 | Supply and laying reinforced precast concrete cable cover LV, Type I, flat, size 250mm x 150mm x 40mm, complete all as specified and directed by Engineer in Charge. |
| 40 | 34W/MW-05/2025-26: PROVN OF LIGHTENNING ARRESTOR TRIPS TO BE CONNECTED AT CAP(E/M PORTION) |
| 41 | M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as requiredof size 20x3 mm copper strip, complete all as specified and directed by Engineer in Charge.Note:- Porcelain cleat/ insulator deemed to be included in quoted rate |
| 42 | M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw including necessary cutting and welding wk, complete all as specified and directed by Engineer in Charge. |
| 43 | S&F in replacement air termination single pointed copper rod12 mm dia 300 mm long in replacement, complete all as specified and directed by Engineer in Charge. |
| 44 | M&L for Earthing complete with copper plate 60×60cm ×3.15mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 20×3 mm copper strip by means of bolts, nuts check nuts and washers of galvanized iron or steel all as shown in electrical palte No 5 of SSR Pt-I connected earthing test point/panel all as specified includingPCC earth chamber using PCC(1:3:6) Type C-2 using, graded stone aggregate,50mm thick cast iron frame with CI cover, funne and wire in esh excavation and earth work, complete all as specified and directed by Engineer in Charge.Note:- Pipe/strip upto 7.5 mtrs also included in quoted rate |
| 45 | 34W/MW-09/2025-26: UPGRADATION OF CERTAIN E/M INFRASTRUCTURE TO BLDG NO P-140(E/M PORTION) |
| 46 | S&F Switch Modular type, 6 Amp, 240 Volts, one way, complete all as specified and directed by Engineer in Charge. |
| 47 | S&F Switch Modular type, 16 Amp,240 Volts, one way, complete all as specified and directed by Engineer in Charge. |
| 48 | S&F Socket outlet, Modular type, 6 Amp, complete all as specified and directed by Engineer in Charge. |
| 49 | S&F Socket outlet, Modular type, 6816 Amp, complete all as specified and directed by Engineer in Charge. |
| 50 | S&F Fan regulator, modular type electronic step type, complete all as specified and directed by Engineer in Charge. |
| 51 | S&F ceiling rose surface Bakelite two to three terminal 65x50 mm+B24, complete all as specified and directed by Engineer in Charge. |
| 52 | S&F Tube light fittings LED type 1x20 Watt 4 ft long incl LED tube rod and incl 3 core flexible wire 0.75 Sqmm copper cable, complete all as specified and directed by Engineer in Charge. |
| 53 | 34W/MW-03/2025-26: ADDN/ALTN TO BLDG NO P-346(E/M PORTION) |
| 54 | Taking down carefully copper/ aluminium point wiring (light fan socket or power) complete along with fittings such as switches, ceiling roses, Pendants regulators Tube fittings and other Kits & fittings/conduitfromsurface /wall . Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface/ location, complete all as specified and directed by Engineer in Charge.Note:- Serviceable fitting/ fixtures will be reused in the work as directed by Engineer- in-Charge |
| 55 | Taking down un-serviceable main switch, DB’s insulators, DB for MCB etc of any type and any capacity and further disposal including making good the disturbed surface and matching the colour of wall with the existing colour wash / paint / distemper wherever required, complete all as specified and directed by Engineer in Charge. |
| 56 | Taking down ceiling fan of any descriptions, servicing and repairs of fans as required, fixing back, connecting and testing the fanfor its satisfactory functionincluding making good the disturbed surface and matching the colour of wall with the existing colour wash/ paint/ distemper wherever required (as per the existing ), complete all as specified and directed by Engineer in Charge. |
| 57 | M&L for point wiringwith FRLSPVC insulated unsheathed multi-stranded copper conductor 1.5 Sq.mm (nominal area ) single core cable 1100 Volt grade drawninand including rigid non metallic concealed PVC Conduit of suitable size (not less than 20 mm) on wall , surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes(Terminal boxes) with earth dolly,duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLSPVC insulated unsheathed stranded copper conductor 1.5 Sq.mm (nominal area ) single core cable as earth continuity conductor to common earth and connected to earth dolly, complete all as specified and directed by Engineer in Charge.(a) One light/fan point controlled by one 1-way switch |
| 58 | M&L for point wiringwith FRLSPVC insulated unsheathed multi-stranded copper conductor 1.5 Sq.mm (nominal area ) single core cable 1100 Volt grade drawninand including rigid non metallic concealed PVC Conduit of suitable size (not less than 20 mm) on wall , surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes(Terminal boxes) with earth dolly, duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLSPVC insulated unsheathed stranded copper conductor 1.5 Sq.mm (nominal area ) single core cable as earth continuity conductor to common earth and connected to earth dolly, complete all as specified and directed by Engineer in Charge.(a) One3/5 pin socket outlet, 5 Amp on independent board |
| 59 | M&L for point wiringwith FRLSPVC insulated unsheathed multi-stranded copper conductor 1.5 Sq.mm (nominal area ) single core cable 1100 Volt grade drawninand including rigid non metallic concealed PVC Conduit of suitable size (not less than 20 mm) on wall , surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes(Terminal boxes) with earth dolly, duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLSPVC insulated unsheathed stranded copper conductor 1.5 Sq.mm (nominal area ) single core cable as earth continuity conductor to common earth and connected to earth dolly, complete all as specified and directed by Engineer in Charge.(a) One3/5 pin socket outlet, 5 Amp on same board |
| 60 | M&L for point wiring with FRLSPVC insulated unsheathed multi-stranded copper conductor 2.5 Sq.mm (nominal area ) single core cable 1100 Volt grade drawninand including rigid non metallic concealed PVC Conduit on wall , surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes(Terminal boxes) with earth dolly,duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLSPVC insulated unsheathed stranded copper conductor 2.5 Sq.mm (nominal area ) single core cable as earth continuity conductor to common earth and connected to earth dolly, complete all as specified anddirected by Engineer in Charge. |
| 61 | Dismantling/ Taking down existing unserviceable sub main wiring from batten / conduit of any size all as directed. Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface / location, complete all as specified and directed by Engineer in Charge. |
| 62 | M&L for sub main surface wiring with PVC insulated unsheathed copper conductor cable of size 6 Sqmm single core through concealed rigid non-metallicPVC conduit of suitable size (Not less than25mm dia)inwall and surface of ceiling including 6 Sqmm PVC insulated unsheathed copper conductor cable for continuous earthing form main earth dolly includingmakinggoodthedisturbedpotionofwall, complete all as specified and directed by Engineer in Charge.Note :- Two run of 6 Sqmm copper cable one run of 6 Sqmm copper cable and PVC conduit will be measured as a single length. |
| 63 | S&F ofSwitch Modular type, 6 Amp, 240 Volts , one way, complete all as specified and directed by Engineer in Charge. |
| 64 | S&F of Switch Modular type, 16 Amp,240 Volts , one way, complete all as specified and directed by Engineer in Charge. |
| 65 | S&F of Socket outlet, Modular type, 6 Amp, complete all as specified and directed by Engineer in Charge. |
| 66 | S&F of Socket outlet, Modular type, 6&16 Amp, complete all as specified and directed by Engineer in Charge. |
| 67 | S&F of Fan regulator, modular type electronic step type, complete all as specified and directed by Engineer in Charge. |
| 68 | S&F of ceiling rose surface Bakelite two to three terminal 65x50 mm, complete all as specified and directed by Engineer in Charge. |
| 69 | S&F of Tube light fittings LED type 1x20 Watt4 ft long incl LED tube rod and incl 3 core flexible wire 0.75 Sqmm copper cable, complete all as specified and directed by Engineer in Charge. |
| 70 | S&F of MCBDB SPN8 Waywith acrylic double door, complete all as specified and directed by Engineer in Charge. |
| 71 | S&F of including flushing in wallMCB distribution board verticalTPN 4 way 415 Volts AC double door type sheet steel phosphatised powder painted with bus bar neutral earth barincluding provision of MCB TPN, FP 100 Ampconforming to IP 43as incomer, complete all as specified and directed by Engineer in Charge. |
| 72 | S&F of MCCB 4 pole100Amp 415 voltwith breaking capacity of 16 KA, complete all as specified and directed by Engineer in Charge. |
| 73 | S&F of MCB SPN 240V 40 Amps C series 10 KA, complete all as specified and directed by Engineer in Charge. |
| 74 | S&F of MCB SP 240V 6 to 32 Amps C series 10 KA, complete all as specified and directed by Engineer in Charge. |
| 75 | M&L for earthing complete withgalvanisedsteel earth plateelectrode 600x600x6mm thick burieddirectlyin ground(earth pitnot less than2 mtr deep belowground levelwith top edgwof the platenot less than 1.4 mtr belownormal ground level, connected earth wire 4 sqmm by means ofbolts nutscheck nutsand washersof galvanisediron or steelall as shownin electrical plateNo 5 connectedto earthingtest pointall as specifiedor indicated includingPCC pitin PCC(1:3:6) type C-1 cast ironframe50mm thickpre castRCC(1: 1 1/2:3)nominal mixcover slabreinforcedwith 8 mmdia mild steeldeformed bar15cc and suitable handleof 10 mm Diaround barincluding necesaryexcavationearth workin soft/loose soiland disposalof spoilto a distancen.exc 50m and funnelwithwatering pipewire meshcopper lugsetc GI protectionpipe of size 15 mm boreincluding testing, complete all as specified and directed by Engineer in Charge. |
| 76 | 34W/MR-03/2025-26: ADDN/ALTN TO BLDG NO P-346(B/R PORTION) |
| 77 | Taking down cement or cement lime plaster of any description and any thickness on brick ,concrete or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed by Engineer in Charge. |
| 78 | M&L for rendering 15 mm thick cement plaster in CM (1:4) on brick or concrete surfaces and finishing the surface even and fair etc, complete all as specified and directed by Engineer in Charge. |
| 79 | M&L for rendering 5 mm thick cement plaster in CM(1:3) on concrete surfaces in ceiling, complete all as specified and directed by Engineer in Charge. |
| 80 | M&L for rendering 15 mm thick cement plaster in CM (1:6) on brick or concrete surfaces and finishing the surface even and fair etc, complete all as specified and directed by Engineer in Charge. |
| 81 | M&L for complete removal of existing treatment from walls, pillars, cornices upto plaster surface by electric sand paper grinder, washing, rubbing down and stopping of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plasteredsurfaces finally rubbed and smooth with sand paper and applying two coat of premium quality exterior emulsion paint over priming coat of exterior primer, complete all as specified and directed by Engineer in Charge. |
| 82 | M&L for preparation new wall surfacefor applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed by Engineer in Charge. |
| 83 | M&L for preparation of new plastered surfaces of Ceiling and applying three coats of white wash on Ceiling, complete all as specified and directed by Engineer in Charge. |
| 84 | M&L for Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper acrylic, white or tinted over a coat ofprimer, complete all as specified and directed by Engineer in Charge. |
| 85 | M&L for Complete removal of existing treatmentand preparation of old plastered /unplastered surfaces of Ceiling and applying three coats of white wash on Ceiling, complete all as specified and directed by Engineer in Charge. |
| 86 | M&L for Complete removal of existing treatment andpreparation of old plastered surfaces of walls and applying two coats of Oil bound distemper acrylic, white or tinted over a priming coat of same make on wall surfaces, complete all as specified and directed by Engineer in Charge. |
| 87 | M&L for applying 1.5 avg mm thick wall care putty (JK/Birla/berger) on walls, including making surface even and smooth using sand paper before applying Priming coat, complete all as specified and directed by Engineer in Charge. |
| 88 | Dismantling floor , hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed by Engineer in Charge. |
| 89 | M&L for 25 mm thick cement concrete Type B1, 1:2:4(using 20 mm graded stone aggregate), as in sub base of floor, complete all as specified and directed by Engineer in Charge. |
| 90 | M&L for vitrified tiles 9 to 10 mm thick light shade (square/ rectangular) polished, area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM (1:6) for laying floor finishes, complete all as specified and directed by Engineer in Charge. |
| 91 | M&L for vitrified tiles 9 to 10 mm thick light shade (square/ rectangular) on vertical surfaces as in skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick cement plaster in CM 1:4 to receive vertical tiles, complete all as specified and directed by Engineer in Charge. |
| 92 | Demolition of cement concrete in ground floors and paving n exc 15 cm thickness (below or above ground level) and removal of debris from MD land, complete all as specified and directed by Engineer in Charge. |
| 93 | M&L for 75 mm thick Cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base to paving, complete all as specified and directed by Engineer in Charge. |
| 94 | M&L forColoured Chequered cement concrete tiles 30cm x 30 cm x 25 mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment, complete all as specified and directed by Engineer in Charge. |
| 95 | M&L for machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over 15mm thick screed bed of CM1:4 including rubbing and polishing, complete all as specified and directed by Engineer in Charge. |
| 96 | M&L for machine cut kota stone slab14-16 mm thick in riser of steps ,skirting, dado and pillar laid over cement screed and cement slurry including 10mm thick cement plaster 1:3 CM to receive kota stone and jointedrubbing and polishing, complete all as specified and directed by Engineer in Charge. |
| 97 | M&L for Granite stone (of any Type) worktable rubbed and polished 18 mm thick machine cut,in steps, jams,pillars,window cills,cooking platforms and like laid and bedded over 15 mm thick cement mortar in CM(1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, including making 01 x hole for gas pipe in each cooking platform, complete all as specified and directed by Engineer in Charge. |
| 98 | M&L for preparation of previously treated/untreated surface of chequered or interlocking tiles and applying two coats of indigo washable floor paint over a coat of priming paint with 30-40% water, complete all as specified and directed by Engineer in Charge. |
| 99 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar, complete all as specified and directed by Engineer in Charge. |
| 100 | M&L for brick work with subclass B bricks, straight or curved on plan exc 6 m mean radius , built in cement mortar (1:6), complete all as specified and directed by Engineer in Charge. |
| 101 | Taking downAluminium chowkats & shutters without taking offshutters from the frame, size of openingexc. 1.0 sqm but not exc 4 Sqm each, complete all as specified and directed by Engineer in Charge. |
| 102 | Taking downAluminium chowkats & shutters without taking offshutters from the frame, size of openingexc. 4 sqm but not exc 8 Sqm each, complete all as specified and directed by Engineer in Charge. |
| 103 | S&F for Powder coatedaluminium frame for doors, windows, ventilators, partitions with one or more rebates including joining cleat for fixing etc, complete all as specified and directed by Engineer in Charge. |
| 104 | S&F for Powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, mortise locks anodised aluminium snap beading screws etc, complete all as specified and directed by Engineer in Charge. |
| 105 | S&F for Powder coated aluminium side hung /sliding type window and ventilator shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, locks, glazing clips, rubber packing, anodised aluminium snap beading, screws etc, complete all as specified and directed by Engineer in Charge. |
| 106 | S&F for Powder coated aluminium decorative grill of size of mesh 50mmX50mm fixed with doors, window for safety of glass etc, complete all as specified and directed by Engineer in Charge. |
| 107 | S&F of Aluminium (extruded section)Door closer hydraulicallyregulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg, complete all as specified and directed by Engineer in Charge. |
| 108 | Supply only sheet glass 6.3 mm thick ordinary qualityin square/rectangular exceeding .5 Sqm in each pane, complete all as specified and directed by Engineer in Charge. |
| 109 | S&F of 12 mm Pre laminated exterior grade both side laminated board, complete all as specified and directed by Engineer in Charge. |
| 110 | Taking down rolling shutter of any description (With all components) and in any size and removing from site area upto 15.00 Sqm each, complete all as specified and directed by Engineer in Charge. |
| 111 | Providing & fixing tiled false ceiling ofDesigner tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and croos \"T\" of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main \"T\" at 600 mm c/c toform a grid of 1200x600mm and secondary cross \"T\" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mmand laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips, spaced at 1200mm c/c along main \"T\", bottom exposed width of 15mm of all \"T\"\" sections of 3mm dia GI wire shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, all complete at all heights, complete all as specified and directed by Engineer in Charge. |
| 112 | 34W/MW-08/2025-26: PROVN OF LPG CYLINDER STORE FOR AIRMEN MESS (B/R PORTION) |
| 113 | Surface dressing n exc 15 cm deep in soft/loose soil, complete all as specified and directed by Engineer in Charge. |
| 114 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil, complete all as specified and directed by Engineer in Charge. |
| 115 | Removing surplus excavated material (soil) to distance exc. 250 m but not exc 500 m and depositing where directed at a level not exc. 1.50 m above the starting point, complete all as specified and directed by Engineer in Charge. |
| 116 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft and loose soil, complete all as specified and directed by Engineer in Charge. |
| 117 | M&L for providing plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation and mass concrete, complete all as specified and directed by Engineer in Charge. |
| 118 | M&L for hardcore of broken bricks of gauge n exc. 63 mm , deposited , spread and levelled and compacted in layers n exc. 15 cm thick , watered and rammed to a true surface, complete all as specified and directed by Engineer in Charge. |
| 119 | M&L for 125 mm thick cement concrete type C-2, 1:3:6 (40 mm graded stone aggregate) as in sub base, complete all as specified and directed by Engineer in Charge. |
| 120 | M&L for Sand filling under floors or watering and consolidation, complete all as specified and directed by Engineer in Charge. |
| 121 | M&L Damp proof course 40 mm thick cement concrete 1:2:4, type B-0 (using 12mm graded stone aggregate), to horizontal or vertical surfaces including necessary formwork & Polythene film, 50 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sq. m, complete all as specified and directed by Engineer in Charge. |
| 122 | M&L for brick work with sub class \"B\" bricks, straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and directed by Engineer in Charge. |
| 123 | M&L rendering 15mm thick on cement mortar 1:4finished fair faces of brick/concrete surfaces even and fair without using extra cement, complete all as specified and directed by Engineer in Charge. |
| 124 | M&L for rendering15 mm thick in CM 1 : 6onother than fair faces of brick work or concrete surfaces etc finished even and fair without using extra, complete all as specified and directed by Engineer in Charge. |
| 125 | M&L for rough cast plaster on brick wall consisting under coat of cement and sand mortar (1:4) not less than 10mm thick and while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel mixed with coarse sand and cement in the ratio 1:1:1 shall be applied and finish even, complete all as specified and directed by Engineer in Charge. |
| 126 | M&L for preparation of new plastered surfaces of walls and applying three coats of white wash, complete all as specified and directed by Engineer in Charge. |
| 127 | M&L for preparation of new plastered surfaces and applying two coats ofcement base paint of approved shade on walls, complete all as specified and directed by Engineer in Charge. |
| 128 | M&L for 75 mm thick plain cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protectionfinishing cement concrete surface even and fair without using extra cement, including making construction joint at a interval not exceeding 2.00 m and at each corner and filled with sealing compound with grade A(normal) in 25/30, complete all as specified and directed by Engineer in Charge. |
| 129 | M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing in Fe 410-W (Gde E- 250) quality A, complete all as specified and directed by Engineer in Charge. |
| 130 | M&L for Mild steel, plain, black sheet 1.25 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc, complete all as specified and directed by Engineer in Charge. |
| 131 | S&F of Stainless steelwire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tack or galvanised wire staple, complete all as specified and directed by Engineer in Charge. |
| 132 | M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates in Fe 410 -W (Gde E- 250) quality A, complete all as specified and directed by Engineer in Charge. |
| 133 | M&L for preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer exposed to view surfaces complete all as specified and as directed complete, complete all as specified and directed by Engineer in Charge. |
| 134 | S&F of Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engineer in Charge. |
| 135 | 34W/MW-03/2025-26: PROVN AND INTALLATION OF DE-WATERING PUMP (E/M PORTION) |
| 136 | Supply, installation , connecting commissioning and testing of self priming pump,Bronze impeller1.5 HP Single Phase, 220 volts with head 33 mtr and discharge 1950LPH, complete all as specified and directed by Engineer in Charge. Note:- The cost shallbe included making foundation size .5mtrx.5mtr x10 mm thick pith RCC structure. |
| 137 | S&FofGun-metal, globe or gate valves 25 mm dia with iron wheel head, screwed both ends for iron pipe, complete all as specified and directed by Engineer in Charge. |
| 138 | S&F ofGun-metal, globe or gate valves 20 mm dia with iron wheel head, screwed both ends for iron pipe, complete all as specified and directed by Engineer in Charge. |
| 139 | Supply and laying 20 mm bores of tubes medium grade\" galvanised with all fittings, complete all as specified and directed by Engineer in Charge. |
| 140 | Supply and laying 25 mm bores of tubes medium grade\" galvanised with all fittings, complete all as specified and directed by Engineer in Charge. |
| 141 | M&L for PVC Foot valveof size 25 mm, dianuts,bolts,rubber gaskets etc, complete all as specified and directed by Engineer in Charge. |
| 142 | M&L for Gun metalNRVof size 25 mm, dianuts,bolts,rubber gaskets etc, complete all as specified and directed by Engineer in Charge. |
| 143 | Supply and Laying ,PVC insulated and FR PVC Round Sheathed, Copper Conductorconforming to IS: 694 PVC insulated 1100 volt grade heavy duty electric cables with copper conductor , cross sectional area 2.5 sqmm 3 core, complete all as specified and directed by Engineer in Charge. |
| 144 | M&L sub main wiring with 2 runs of copper conductor PVC FRLS insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked25mm dia as per IS specification fixed concealedin wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distemper all as directed at site, complete all as specified and directed by Engineer in Charge. Note: Two runs of 4 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathedcopper conductor as earth wire, conduitand conduit accessories will be measured as one length |
| 145 | S&F Single pole and neutral (SPN) 4 way MCB distribution box double door powder coated sheet metal encloser240 voltsincluding 200 Amps rated bus bar, complete all as specified and directed by Engineer in Charge. |
| 146 | S&F of MCB single pole (SP) B curve240 Volt 6 to 32 Amp, rupturing capacity 10 KA, complete all as specified and directed by Engineer in Charge. |
| 147 | S&F of MCB single pole & Neutral (SPN)B curve 240 Volt 40 Amp, rupturing capacity 10 KA, complete all as specified and directed by Engineer in Charge. |
| 148 | S&F single phase DOL starter with incorporating single phase pump starter -economical model ind SS enclosure incorporating 2 pole definite purpose contactor , single pole MCB , Ammeter, ON/OFF push buttong , motor ON indicatorwith dry run protection Make C&S,/Havelss, Having capacity 1.5 KW Capacitor rating50 MFD , MCB Range 32 Amp, MCB C Curve, complete all as specified and directed by Engineer in Charge. |
| 149 | M&L for plain cement concrete 1:3:6, type C-1, (using 20mm graded stone aggregate) for road cutting / making plinth for transformer where required and fair finishing to exposed surfaces without using extra cement including necessary form work, complete all as specified and directed by Engineer in Charge. |
| 150 | S&F new Horizantalplastic 2.5 feet rectangularloft tankhaving capacity 250 ltr moulded polythene water storage tank inthree layerin white colour and fix in position, complete all as specified and directed by Engineer in Charge.Note : Contractor will be supply the item after visit the site. |
| 151 | M&L for earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand includinggalvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means ofnuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dollyall as shown in electrical plate No 3 of MES SSR part I and testing on completion includingnecessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame, funnel with watering pipe 20mm dia medium grade, wire mesh and lugs, GI protection pipe,15mm deadlight grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed. |
| 152 | M&L for Making holes in 100 mm dia bore in RCC wall/roof sump using suitable machinery or equipment and close again using Cement mortar 1:3:4 make or repair of pot holes in existing building wall/sump for passing of pipe / cables / pipe / cabletray, the disturbed surface of wall to passing of pipe cable/removing of existing ductshall be make good by applying cement plaster 1:4, and if required to fill with brick work 1:3:6 and applyingputty and colour wash etc matching with the existing surfaces, complete all as specified and directed by Engineer in Charge. |
| 153 | Labour for connectingthe existing 40/32mm MS pipe ,suction and delivery endof any type from the AHU and S&F with newpipes of various material and sizes ofpipe given in schedule, complete all as specified and directed by Engineer in Charge. |
| 154 | M&L for demolishing Floor\ RCC floorof size 1.5mtrx1.5 mtr x1.5 mtr without damaging of existing structure / wall/ AC pipeand S&F new , loft horizontalwhite plastic tankinstallation of 250 ltr PVC tank of sizeas per recommendation by OEM 1.0x.70x1.2mtrin theditch , After installation of PVC tank given in schedule the ditch will be again made bith RCC structure and filledwith water sealed cement /water sealed compound , The tank ditchwill be covered with same size of floor tiles the cost shall be included minimum 64 sqfttile for one place . The size of tiles 02 feetx02 feet .Thetile shuld be matched withsame material and size and colour of existing tiles , The cost shall be included of Tiles , Excavation . Removal of Debries, Soil and Cement , sandand tiles, complete all as specified and directed by Engineer in Charge.NoteThe contractor shallmust to visit the site before quoting of tender ,Location 200 SQN |
| 155 | S&F of Submersible pump, horizontal typeelectric driven 415 V, TP suitable for 30 mtr head open welltype 3 HP, complete all as specified and directed by Engineer in Charge. |
| 156 | 34W/MR/04/2025-26: PROVN OF CERTAIN E/M EQUIPMENT (E/M PORTION) |
| 157 | Supply installation, Connecting,commissioning & testing ofHorizontal type submersible pump set, open well of capacity 5 HP, 415V, 3Ph, 50Hz, multi stage pump with minimum Head 82 mtr discharge 600LPM, RPM 2800, with 50 RM, 3 core, flat type copper wire of minimum 6 sqmmand DOL starter of capacity 5HP for submersible pump set with single phase preventer, dry run preventer, phase reversel indicator complete all as specified and all directed.Note - (a) This cost of foundation is included in quoted rate.(b) 10 Rm Suction & 10 Rm delivery GI pipe of required size is included in quoted rate. |
| 158 | Supply installation, Connecting,commissioning & testing of Horizontal type submersible pump set, open well of capacity 10 HP, 415V, 3Ph, 50Hz, multi stage pump with minimum Head 82 mtr discharge 696 LPM, RPM 2900, with 50 RM, 3 core, flat type copper wire of minimum 10 sqmmand DOL starter of capacity 10 HP for submersible pump set with single phase preventer, dry run preventer, phase reversel indicator complete all as specified and all directed. Note- aThis cost of foundation is included in quoted rate.b 10 Rm Suction & 10 Rm delivery GI pipe of required size is included in quoted rate. |
| 159 | Supply installation, Connecting,commissioning & testing of pump sets centrifugal type pumping set of discharge capacity minimum 140LPM working head minimum 20M bowl length 305mm with IC engine driven complete 15 HP air cooled 1500 RPM, inclusive fuel tank 20 ltr capacity, maintenance free Battery 12 volt -01 No, in-built Self starter-01 and additional of manually hand operated axial drive arrangement. The diesel driven pump will have trolly mounted having RIM size 14 inch, section width 165 mmsize of tyre 40cm x 40 cm x 14cm, tread depth of tyre 8.5 mm, minimum weight 7 kg, Make MRF/CEAT. The wheel will have rubber tyre alonwith tube & steel RIM, nut bolt, washer etc. The wheel with suitable size bearing both wheelwill be fixes in trolly with axle , The axle made of 65 mm dia heavy grade steel pipe, minimum length of axle 1.5 mtr, support angel iron frame made of 6 mm thick iron plate, duly painted with two coat of stove enamel paint which is capable to carry the load of IC engine with centrifugal pump and pulling arrangement, vibration pad, nut bolts, washer for holding to pump with motor, with \"0\" vibration of pump set including necessary water connectioninlet/ outlet testing completeas existing and as directed by Eng-In-Charge. |
| 160 | Supplyinstallation, Connecting,commissioning & testing Horizontal type submersible pump set, three phase open well of capacity 20 HP, 415V, 3Ph, 50Hz, multi stage pump with minimum Head 30 mtr discharge 2910 LPM, RPM 2900, with 100 RM, 3 core, flat type copper wire of minimum 10 sqmm and DOL starter of capacity 20 HP for submersible pump set with single phase preventer, dry run preventer, phase reversel indicator complete all as specified and all directed.Note- a This cost of foundation is included in quoted rate. b 10 Rm Suction & 10 Rm delivery GI pipe of required size is included in quoted rate. |
| 161 | Supply installation, connecting commissioning and testing of pump set with suitable capacity motor of Monoblock pump set 5 HP suitable for 415 V ,3phase system having capacity 525 LPM , 18-24 Mtr Head . with electric motor3 phase 415 Volts, 50 C/s ,2830 of rating as per the recommendation of manufacture of pump set, with trolly mounted havingrubber tyre alonwith tube & steel RIMmake MRF,pump will have trolly mounted having RIM size 14 inch, section width 165 mm.Size of tyre 40cm x 40 cm x 14cm, Tread Depth of tyre 8.5 mm, minimum weight 7 kg, Make MRF/CEAT. The wheel will have rubber tyre alonwith tube & steel RIM, nut bolt, washer etc. The wheel with suitable size bearing both wheelwill be fixes in trolly with axle , The axlce made of 65 mm dia Heavy grade steel pipe , minimum length of axle 1.5 mtr,support angel iron frame made of 6 mm thick iron plate, duly painted with two coat of stove enamel paint which is capable to carry the load of monoblock pump ,andpulling arrangement, vibration pad, nut bolts washer for holding to pump with motor, with \"0\" vibration of pump set, including necessary water connectioninlet/ out let,testing complete.as existing and as directed by Eng-In-Charge. Having arrangement ofsuitable capacity DOLstarter mounted on trollyand frame having plate/ angeland Amp meter, Voltmert, single phase preventer, dry run protection, relay, Tripping ON/OFF indicator button, iron angles frame, anti vibration pad, nut bolts washer for holding to pump with motor and water connectioninlet/outlet testing complete as existing and as directed by Eng-In-Charge. NOTE:- (a) This cost of Trolly mounted is including in quoted rate-01(b) 02 Nos of pump set will be required to set on concrete foundation (1:2:4)and 1 No. pump set will be trolly mounted. |
| 162 | NOTE: BOQ has bifurcated job wise, if bidder quoted different rate for same item at different jobs then lowest quoted rate shall be considered for acceptance for all jobs. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail