| 1 | Supply and fix 2 mm thick coloured electro static conductive vinyl flooring optimal and constant static conductive property, antifungal, anti bacterial on levelled floors (using cementitious self levelling compound using suitable adhesive, copper strip) and cord welding of joints including sealing of joints of wall and floor with sealing compound etc. complete all as specified and directed.Note: The work to be carried out as per manufacturer instruction and by authorised applicator only.colour and design shall be approved by Engr-in-Charge |
| 2 | M & L aluminium composite panel shall be metalic series of approved shade, the panel shall be of 4mm thick with combination of aluminium skin materials of 0.25mm thick aluminium sheet of alloy grade 1100 H cover material coated on external side with PVDF (Poly vinytedene floride) of KYNAR, PVDF coating containing 70% KYNAR 500 resign for antifungal & anti bacterial properties & the central core shall benatural polyethylene(LDPE and HDPE) bonded to aluminium skin on both sides. all as per manufecturer\"s instructions & all as specified & directed. Note: rateof aluminium shall be deemed to be included in the quoted rate |
| 3 | M & L for providing PU sealent in expansion joints of width n exc 45 mm filler boards including removal of old sealent complete all as directed. |
| 4 | Material and labour for filling with non bituminous PE form filler boards450 mm width(minimum) in crumple joints as per manufacturer\"s instructions, including necessary scaffolding complete all as specified and directed. |
| 5 | Supply and installation in repair of hermetically sealed swing type door of size 1800mm x 2100mm made of SS304 sheet of thickness 0.8 mm for Door Leaf and SS 304 sheet of thickness 1.2mm for Door Frame and designed to fit flush into the wall panel system on both sides. Standard 50mm panel shall have frame width of 100mm. Shutters shall be of 45mm thick sealed andPUFF insulated with polyurethane foam injected under high pressure with a minimum density of 40 kg/m3. Door shall be fitted with following accessories as part of the door: Stainless steel hinges 3Nos per leaf, Stainless Steel \"D\" type handles, Stainless steel push plates on push side. Standard arm door closure (TS-1002)& tower bolt. View panel along with self-adhesive tape and silicon sealant. One side key operated locking arrangement, Automatic door bottom seal at the bottom of shutter. |
| 6 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing ) and removingrubbish off the MD premises |
| 7 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc.and removing debris out side MD land. Note: The place of disposal shall be find out by the contractor. |
| 8 | Taking down cement plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. and rubbish off the premises.Note: The place of disposal shall be find out by the contractor. |
| 9 | M&L granite (of any type) slab 18-20 mm thickmachine cut in floors, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete andincluding20mm thick screed bed in CM (1:6) complete all as specified and directed by Engineer In Charge |
| 10 | M&L granite (of any type) tiles 12 mm thick machine cut, in skirting/ dado etc. vertical surfaces laid over cement screed, and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete andincluding10mm thick backing coat in CM (1:4)complete all as specified and as directed by Engineer In Charge |
| 11 | M&L Marble tiles Makrana White 20mm thick and matching existing pattern machine cut in floors, bedded jointed and pointed with grey cement slurry including cutting and polishing and including 20mm cement sand screed in cement mortar 1:6 completeall as directed |
| 12 | M&L Marble tiles Makrana White 20mm thick and matching existing pattern machine cut in vertical surfaces dado/skirting laid over cement screed and pointed with grey cement slurry including cutting and polishing and including10mm thick backing coat in CM 1:4complete all as specified and as directed by Engineer In Charge |
| 13 | M&L Machine cut Kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete andincluding20mm thick screed bed in CM(1:6)complete all as specified and as directed by Engineer In Charge |
| 14 | Ditto all as per item No 13.00 above but in riser of steps, skirting, dado and pillar etc including 10mm thick backing coat in CM 1:4 complete as directed. |
| 15 | M&L 75mm thick PCC type D-2, (1:4:8) using 40mm graded stone aggregate as in sub base complete all as specified and directed |
| 16 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces of any description in CM (1:4)with Ready mix plaster mixed with integral water proofing compound and finished even & smooth without using extra cement completed all as specified.(Note : WPC will be measured and paid separately) |
| 17 | Supply only integral water proofing compound of approved ISI make. |
| 18 | M&L preparing newly plasteredsurfaces of walls and applying two coats of Acrylic based exterior paint exterior grade (100% Acrylic)over a coat of primer & bio wash on wall. |
| 19 | M&L for rendering 15mm thick in CM 1:6 on other than fair faces of bricks work or concrete finished even and smooth without using extra cement. |
| 20 | Material and labour for preparation of newly plastered or previously untreated surfaces of walls and applying two coats of acrylic (100 % antifungal interior grade) paint over a coat of primer etc.complete all as specified and directed. |
| 21 | S&F in repair8mm thick 600x600mm size gypsum prelaminated tiles false ceiling on aluminium anodized snap grid of size 605 mm x 605 mm with aluminium anodized angle 20 mm x 20 mm x 1.2 mm fixed to wall along the perimeter of ceiling with the help of nylon sleeves & screws, at 610mm centres and main and cross tees of size 31.75 mm x 31.75 mm x 1.6mm & 25.4 mm x 25.4 mm x 1.22 mm respectively with ceiling cleats / angle brackets of size 15 mm x 15 mm x 1.5 mmincluding 4 mm dia.G.I.wire suspended from the soffit at 1220 mm centres (upto 1200 mm length maximum) fixed to roof slabs by means of 12 mm diafancy type steel anchor fastner hook 80 mm long complete all as specified and directed. |
| 22 | S & F in repairs 12mm thick plywood grade BWR fixed with screws including fixed with screws/teakwood beading/aluminium beadingto wooden or Aluminium frame work or in wall or floor cupboards duly fixed with wall with fastners wherever requiredetc.complete all as specified and directed.((New aluminium sections shall be msrd and paid seperately) |
| 23 | M & L1.5mm decorative acrylic laminateof surface finish , colour and pattern as approved, fixed with approved adhesive as per manufacturer\"s instruction |
| 24 | S & F in repairs 12mm thick prelaminated particle board exterior grade with decorative choice lamination on both sidesfixed with screws/teakwood beading/aluminium beadingto wooden or Aluminium frame worketc.complete all as specified and directed.((New aluminium sections shall be msrd and paid seperately) |
| 25 | Taking down old aluminium framed windows/door/partion including glass/ply/particle board at any description and in any position |
| 26 | Supply and fix powder coated aluminium sections of various sizes required for frame and shutters of doors, windows, ventilators and partition with one or more rebates etc.including necessary joining cleats, glazing clips, beading, rubber packing, screws and all other fittings like locking arrangement for shutters etc. complete all as specified and directed.Notes:-(i) Glazing/wire mesh shall be measured and paid separately.(ii) Item shall be paid as per the weight of aluminium section however the rate quoted shall be inclusive of the cost of neoprene beading, glazing pins, screws, handle,hinges,locking arrangement ,towerbolts etc which shall not be measured for arriving the weight |
| 27 | S & F sheet glasses,plain4.80mm to 5MMthickglazingall withaluminum beading, glazing pin etc, or with oil putty in squaren exc .5 sqm in each pane |
| 28 | .-do-- all as above but exc 0.5 sqm in each pane |
| 29 | S&F aluminium alloy wire mesh 0.45 mm nominal dia of wire and average width of aperture 1.4 mm fixed with aluminiumwire staples and beading /U sectionif requires complete all as specified and directed |
| 30 | S&F in repairs anodized aluminium framework for doors, windows, ventilatorswith one or more rebates including jointing cleat for fixing and all fittings, etc. complete all as per existing pattern and directed |
| 31 | Supply and fix in repairs plain aluminium sheeting 0.71mm thick alloy 31000 H4 in shutters ,crumple joint including fixing to aluminium frame work with rivets etc. complete all as specified and directed. |
| 32 | Material and labour for preparation of old plastered surfaces of wall by washing and rubbing down and stopping of old surfaces and complete removal of existing treatment and applying two coats of acrylic (antifungal) paint interior grade over a coat of primer etc. complete all as specified and directed. |
| 33 | Material and labour for preparation of old plastered surfaces of ceiling by washing and rubbing down and stopping oldsurfaces/painted surfaces and complete removal of existing treatment and applying two coats of acrylic (antifungal) paint over a coat of primer etc.complete all as specified and directed. |
| 34 | Material and labour for preparation of old steel and iron work of any description not otherwise described over 10 cm width or girth and applying one coat of antifungal synthetic enamel paint etc.complete all as specified and directed. |
| 35 | M & L for mirror polishing to the existing stone flooring of any type to give high gloss finishwith machine evenly with fine granding( Fine Grade No. 120) andfinally oxalic acid shall be dusted over the surface at the rate of thirty three (33) gms. per square metre sprinkled with water and rubbed hard with pad of wooden rags and floor shall be wiped with a moist rag and dried with a soft cloth and finished clean including pointing of joints with cement slurry mixed with pigment to match the colour of slab complete all as specified. |
| 36 | Supply and application of silicone Sealantat the junction of the windows from external side, sky lit roof, wall-floor tile joints |
| 37 | S&F dholpuri stone tiles of size 200 x 100 of thick 10 mm fixed to dado set and jointed in neat cement slurry and pointed in white or coloured cemet to match and including10mm thick screed bed in CM (1:3), complete all as specified and directedNote:- Colours of dholpuri stone tiles shall be approved by Engr-in-Charge before execution and the same shall be deemed to be included in the above rate. |
| 38 | Material and labour for vitrified ceramic tiles 600 x 600 x 8 to 10 mm of light colour (matt finish/nano finish, double charged), polished/glazed area of each tile in floors set jointed and pointed in epoxy grout to match flooring with and including 20mm cement sand screed in cement mortar 1:6 complete. The joints shall be 2 mm thick and 2 mm thick spacer at every corner shall be used all as specified and directed. |
| 39 | Material and labour for glazed/ polished ceramic tiles in vertical surfaces 600 x 300 x 8 to 10 mm thick (glossy/nano finish, double charged), set and jointed using tile adhesive (3-6 mm thick) and pointed in epoxy grout to match shade of tile including 10mm thickbacking coat in cement mortar 1:4 complete all as specified and directed.Note: both the substrates should be cleaned, spread the adhesive on plastered surface and comb with a notched trowel and place the tile. |
| 40 | S&F400MMX400MMX 6 to 8mm thick non skid ceramic tile any colour tile set jointed and pointed in coloured cement slurry in flooring with and including 20mm cement sand screed in cement mortar 1:6 completeall as directed |
| 41 | S&F glazed ceramic coloured tiles of size 300x450x 7mm thick in vertical surfaces set and jointed in neat cement slurry and pointed in coloured cement to match and including10mm thick backing coat in CM 1:4complete all as specified and as directed by Engineer In Charge |
| 42 | Material and labour for granite slabs, 18 to 20mm thick, table rubbed and polished fixed independently to walls duly supported with partition walls, as directed at site. |
| 43 | Supply and fix in repair plain ceiling system consisting of 600 mm x 600mm tiles (As per IS: 2095-1996: Part I) of pre coated galvanised aluminium in 0.7 mm thickness in required colour to be laid “on grid systems with 15 mm wide T - section flanges in required colour having rotary stitching on the 1200 mm & 600 mm cross tees. The grid should be GIwith 15mm wide T - section flanges in required colour shade having rotary stitching on all T sections i.e. the main runner, 1200 mm & 600 mm. Tees with a web height of 32 mm. , wall angles of size 19x19mm, secured to walls at 450 mm maximum centres including necessary fitting and 4 mmGI suspenders fixed to slab using steel fastener in ceiling all as specified and directed. |
| 44 | Supply and fix wall mountained U shaped powdercoated stainless steel hand rail of size 600 x 100 mm with hinge including all necessary fittings complete all as specified and directed. |
| 45 | Supply and fix wall mountainedstainless steel hand rail of 30 to 40 mm dia with hinge including all necessary fittings complete all as specified and directed. |
| 46 | Supply and fix surface mount corner guard of wing size 76 mm with 1.78 mmcontinuous aluminium retainer, 2 mm vinyl cover, and with top/bottom caps of colour as specified and of required height fixed to walls with self tapping screws of height as per site requirement and making good complete all as specified and directed. Make: Fastrack-Inpro ( 1.2 m height) or equivalent make as approved. |
| 47 | Demolition of brick work or stone/boulder masonry, built in cement mortar, including all quoins, arches, pillars, shaft walls, crumple edges and supports for water pipeline carefully including copings etc.and removing debris outside MD land complete all as specified.Note: the work to be carried out in roof of G+6 storey bldg |
| 48 | M&L for brick work with sub class \"B\" bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4)complete all as specified. |
| 49 | M&L brick work with sub class \"B\" old size bricks half size, straight or curved on plan exc 6m mean radius built in CM 1:6 including duly reinforced with 10 mm dia MS round bars 2 nos horizontally after each 4 layer of bricks complete all as spd and directed |
| 50 | Supply and fix in repair health faucet with flexible pipe(ABS Body) with 01 meter long PVC tube and wall hook complete all as specified and directed. |
| 51 | Supply and fix in repairs table top ceramic wash hand basin coloured vitreous china oval shape and of size610x460x150mm. |
| 52 | Supply and fix in repair white vitreous china urinal (full stall type) flat back, (same as existing) with cast iron hangers, 15 mm dia CP spreader, 32 mm dia CP brass domical white for connector to 32mm dia cast bottle trap including cutting and making good the wall and floors whereever required complete all as specified and directed. |
| 53 | Supply and fix in repair PVC waste pipe 40mm bore, 90cm long fixed with waste coupling complete all as specified and directed. |
| 54 | Supply and fix in repair urinal partition of vitreous China white 310x700cm size tapering at bottom, 50mm thick to match existing pattern complete all as specified and directed. |
| 55 | Supply and fix in repair 6mm thick superior quality beveled edge mirror of selected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers size 600mm x 450 mm complete all as specified and directed. |
| 56 | Supply and fix flat back urinal of size 360 x 330 x740 mm with integrated electronic flushing cistern with fixing accessories complete all as specified and directed. |
| 57 | S&F in repairs 15 mm bore Florentine Pillar Cock with Extended Lever Handle cast copper alloy chromium plated complete all as specified. |
| 58 | S&F in repairs 15 mm bore Florentine Bib Cock with Extended Lever Handle and Wall Flange cast copper alloy chromium plated complete all as specified. |
| 59 | S&F in repairs toilet paper holder complete all as specified. |
| 60 | M&L for injectingcement slurry grout in the ratio 1:2 (1-Cement 2-water) including super plasticizer (Supercom-100) 250 ml/50 Kgs. Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 0.5 Kg/cm2 etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled. The damaged area of the slab is to be repaired using polymer plaster(POLYMER MODIFIED MORTAR) (1:5:15) 1 monobond 5 Cement-15 sand) –in damaged areas . nozzle to be fixed to the slab using epoxy grout.The work includes complete sealing of cracks, voids from both floor and ceilng(For repair to slab) |
| 61 | M & L for water proofing treatment of external walls by applying two coats of elastomeric external acrylic water proofing coating material after cleaning the surface thoroughly and sealing all cracks with acrylic sealing compound as per the manufacturer’s specifications and directions of Consultant/Architect. complete all as specified & as directed by EIC. (Note :- work will be carred out with scafolding all over bldg upto G+6 th floor of wall. Rate of scaffolding & acrylic based exterion paint is included in this item). |
| 62 | S&F 10 mm thicktoughenedglass as in partition, doors and similar works including cutting to shape drilling holes required fixed to granite platform or floorcomplete all as specified and directed by Engr-in-charge |
| 63 | M & L for wooden wall panelling made out of15 mm thick Ist class Hardwoodboarding, treated for termite proof,planed one side and edges tongued and groovedwidth of panels exc 10 cm and n.exc 30 cm and fixed with coloured screws, nails beads , jambs / glue to aluminiumframe work complete all as specified. |
| 64 | M & L for preparation of newwooden surfaces of any description over 10 cm in width or girth and finish the wood surface with two coats of french polishingwith undercoatoverwood fillerand make the surface fully shined complete all as spd and directed by Engr-in-Charge |
| 65 | S & F in repairs 18/ 19mm thick plywood grade BWR fixed with screws including fixing and polishing teakwood beading 4mm thick to exposed sides, as in cupboards, shutters etc including necessary fixing arrangements as directed by Engineer in Charge. |