| 1 | Takng out old unserviceable under ground HT cable upto 120 sqmm from trenches/floor/road/pipe/ along poles including taking out old bricks complete all as specified and directed by Engineer-in-charge.Note: Excavation,earth work required for item shall be measured and paid seperately under respective items of this Schedule. |
| 2 | Supplying, laying, jointing and testing XLPE insulated,screened,PVC beded,galvanised steel strip or wire armoured,clectric power cables (heavy duty)with aluminium conductor HT cable 11000 volts grade with cross sectional area 95 sqmm 3 core laid in trenches/ ducts/ along poles/through pipescomplete all as specified & directed by Engineer-in- charge.Note: Excavation & earth work shall be measured & paid separately under appropriate item of this Schedule. |
| 3 | Excavation in trenches not exceeding 1.5 mtr depth width and not exceeding 1.5m depth for laying under ground cable in loose/soft soil complete all as specified & directed by Engineer-in- charge. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified & directed by Engineer-in- charge. |
| 5 | Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified & directed by Engineer-in- charge. |
| 6 | M&L for PCC preparation including cutting up to 45 cm width and depth of the road/hard standing and making good disturbed surfaces by using PCC type C2(1:3:6) by using 40mm graded stone aggregate for the fixing the pipe/laying cables complete all as directed by the Engr. in Charge. |
| 7 | M&L for Boring hole across the Road/plinth/hardstanding/path/drain/pavement etc., suitable for inserting HDPE/GI pipe of upto 100mm dia bore pipe for cable passing without damaging existing Raod/path/hardstanding/floor by manual using trenchless technology tools/necessary equipment complete all as specified & directed by Engineer-in- charge. |
| 8 | Laying and commissioning only HT UG Cable of size 3Core , 95 to 120 Sqmm, 11000 V grade PVC/XLPE insulated, PVC sheathed armoured conductor laid in trenches/Road/paths/ on poles through GI protection pipe complete including connection of cable at both ends with suitable size of glands, aluminium lugs complete joining, testing and commissioning including disconnecting and removing existing UG Cable. Note:1. HT UG Cable laid is Serviceable cable retrieved under relavent items of the schedule.2.Earth work for the cable removing, layingmeasured and paid separately under relevent items of the schedule. |
| 9 | M&L for removing connections of faulty cable from both endsHT terminaton after meggaring and confirm the faulty cable taking directions from Engr-in-charge as specified and finding the spot of the cable faulty position with any other mechanism like cable fault locator or manual with necessary earth work made and remove the cable from the trench and jointing the cable to serviceable condition after necessary meggaring values obtain and shifting or relaying the cable all as specified and directed by Engr-InCharge.Note: 1. Earth work for the cable removing, laying and necessary joints involved measured and paid separately under relevent items of the schedule.2. hiring or arrangment of cable locator/cable route tracker/other any mechanisim with skilled operator for positioning the cable fault locationis deemed to be included in the rates quoted |
| 10 | M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron earth strip 25x4mm thick fixed by means of bolts, nuts and washers and watering pipe 20mm dia GI medium grade withsocket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire meah etcall as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009complete and all as specified and direcrted by Engr-in-charge Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level.(ii) GI strip connecting upto panel and DBs earth connection is included in this item. (iii)GI pipe 40 mm dia protection pipe shall be provided upto Ground level. |
| 11 | M&L for fabrication of cross arms, bracings, supports,clamps and back plates fabricated from structuralsteel section including nuts, bolts, washers, welding,bending, cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed by Engr in charge. |
| 12 | M&L for painting of old painted surfaces with synthetic enemel paint to HT steel tubbular pole 11 mtr long including clamps,brackets,chanels,cross arms,bracing support and supporting pipe of cables etc including zebra painting at bottom up to 1.5 mtr above from the PCC couping and writing pole No with white paintcomplete etc complete all as specified and as directed. |
| 13 | All as per item No 12 above herein before but for 4 pole structure including cross arm,bracings etc. complete all as specified & directed by Engineer-in- charge. |
| 14 | All as per item No 12 above herein before but for 2 pole structure including cross arm,bracings etc. complete all as specified & directed by Engineer-in- charge. |
| 15 | S & F GI tube light grade galvanised of size 100 mm with all fitting and fixed to wall and celling or laid in floors/under road etc complete all as specdied and directed by Engineer-in- Charge. |
| 16 | S & F GI tube light grade galvanised of size 50 mm with all fitting and fixed to wall and celling or laid in floors/under road etc complete all as specdied and directed by Engineer-in- Charge. |
| 17 | S & F GI tube light grade galvanised of size 80 mm with all fitting and fixed to wall and celling or laid in floors/under road etc complete all as specdied and directed by Engineer-in- Charge. |
| 18 | S&F in replacement disc type insulator, porcelain,vitreous 145 mm high and 225 mm dia ball and socket type,white,brown or green \"Single disc assembly\" for tension with tension clamps for conductors,suitable for working pressure 11000 volts grade complete all as specified and directed by Engineer-in-charge. |
| 19 | S&F in replacement Post insulator suitable for AB switch porcelain,vitreous white,brown or green of 400 Amps rating suitable for working pressure 11000 volts grade complete all as specified and directed by Engineer-in-charge. |
| 20 | Supply and fix in replacement of cradles,hexagonal/rectangular,fabricated with Galvanised steel wire 3.15 mm or 4 mm dia, for LT/HT guard wire and craddles of required size or span complete all as specified and directed by Engineer-in-charge. |
| 21 | Supply and fix Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified & directed by Engineer-in- charge. |
| 22 | Supply and fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified & directed by Engineer-in- charge. |
| 23 | S&F in replacement of HT 11 KVAir break switch, gang operated and drop out fuse unit having 12 Insulators for outdoor use, complete with all acessories, mounted on insulator and steel frame, with operating mechanism working from ground level, for current rating up to 200 Amps including GI pipe of suitable size,clamps,nuts,bolts amd washers etc complete all as specified & directed by Engineer-in- charge. |
| 24 | S&F in replacement of HT 11 KV Air break switch, gang operated and drop out fuse unit having 12 Insulators for out door use, complete with all acessories,, complete with all acessories, mounted on insulator and steel frame, with operating mechanism working from ground level, for current rating up to 400 Amps including GI pipe of suitable size,clamps,nuts,bolts amd washers etc complete all as specified & directed by Engineer-in- charge. |
| 25 | S&F in replacement of lightning arresterss expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo amp suitable for 11000 Volts complete all as specified & directed by Engineer-in- charge. |
| 26 | S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified & directed by Engineer-in- charge. |
| 27 | S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm complete all as specified & directed by Engineer-in- charge. |
| 28 | S&F cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified & directed by Engineer-in- charge. |
| 29 | S&F cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmmcomplete all as specified & directed by Engineer-in- charge. |
| 30 | S&F Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified & directed by Engineer-in- charge. |
| 31 | S&F Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm complete all as specified & directed by Engineer-in- charge. |
| 32 | M&L for cutting/trimming of branches of tree tuching/aproaching LT/HT over lines/UG Cables of various spans(having 40 to 45 mtr) up to 3 mtr width on each side from difrent site of grith up to 10 cm with cutting equipments hacksaw,axe,ladders,rope and safety measures etc including disposal of trimmed branches 100 mtr away inside the cantonment area and cleaning the areas complete all as specified & directed by Engineer-in- charge. |
| 33 | M&L for cutting,trimming bushes,weed/tidy plants to bring in a cleaned position of substation/transformer yard installation without disturbing installed accessories/equipments by using cutting equipments hacksaw,axe,ladders,sword,trimmer for well groomed with safety measures etc including disposal of trimmed branches 100 mtr away inside the cantonment area and cleaning the areas complete all as specified and directed by Engineer-in-charge. |
| 34 | M&L for disconnectingHT & LT side cables of follwing indoor/outdoor transformer of capacity 100 KVA to 500 KVA and earth strip from body and neutral of transformer mounted on two pole/four pole structure/staging/sub stn and taking down the transformer manually/using mechanical means and lifting loading and transportation to MES store yard/site to civil workshop for repair and servicing duly opening of covers,draining out existing transformer oil,lifting of core,cleaning oil tank using chemicals,cleaning of core with core varnishing heating and bringing back the same after repairs to the same point all as specified and directed by Engineer-in-charge. Note-(i) Any type/material,dihydretion of transformer oil reassembling after repair etc.will be measured and paid seperately under relevant item of the schedule. (ii) Spare part shall be measured and paid seperately as supply only and cost of fixing and connection of spare shall be deemend to included in the quoted rate of the above items. |
| 35 | M&L for Dehydreation and filteration of exisitng transformer oil for transformer of any capacity using centrifugal plant to eliminate foreign particals and to improve die electric straingth not less than 40 KV for one minute in 2.5 mm electrode gap as per relevant IS and to bring the acidity within the permissible limit complete all as specified and directed by Engineer-in-charge.Note- Transformer oil required for toping up shall be measured and paid for seperately under respective item of this schedule. |
| 36 | Supply and topping up to filling of fresh transformer oil conforming to IS-335 having die electric strength not less than 50 KV in existing transformer installed at different locations complete all as specified and directed by Engineer-n-charge. |
| 37 | M&L for assembling of HV and LV coils including necessary insulation with paper boards and varnishing,making internal connections,drying,removal of moisture from core and coils heating etc complete including testing of transformer on full load of capacity upto 500 KVA complete all as specified and directed by Engineer-in-charge. |
| 38 | Disconnecting transformer of capacity 100 to 160 KVA , indoor/outdoor from HT/LT side carefully at site, dismantling carefully and removing primary and secondary terminals, top cover, conservator tank, neutral earth strips and draining out transformer oil to the required level and storing carefully in cleaned containers, cleaning of terminals, inspection of core, supply and replacing the 5 mm thick rubberised cork sheet gasket to leak proof seal under relevent item of this schedule for tank top cover and reassembling the complete dismantling items by replacing unserviceable minor spares such as nut, bolts, washers, expulson vent diaphram, bush seals and filling drained out transformer oil after filtration to eliminate foreign particals and to improve die electric straingth not less than 40 KV for one minute in 2.5 mm electrode gap as per relevant IS and to bring the acidity within the permissible limit complete and reconnecting the HT/LT supply cable ends at the site and testing complete all as specified and directed by Engr-In-Charge. |
| 39 | All as per item No 38 above here in before but transformer of capacity above 200 KVA and up to315 KVA complete all as specified & directed by Engineer-in- charge. |
| 40 | All as per item No38 above here in before but transformer of capacity 400 KVA to500 KVA complete all as specified & directed by Engineer-in- charge. |
| 41 | Supply and fixing in replacement of ceramic LV bushingfor transformer of capacity 100 KVA to 200 KVA complete all as specified and directed by Engineer-in-charge. |
| 42 | Supply and fixing in replacement of ceramic LV bushingfor transformer of capacity 315 KVA to 500 KVA complete all as specified and directed by Engineer-in-charge. |
| 43 | Supply and fixing in replacement of ceramic HV bushingfor transformer of capacity 100 KVA to 200 KVA complete all as specified and directed by Engineer-in-charge. |
| 44 | Supply and fixing in replacement of porcelain HV TFR bushing complete with bushing stud (brass metal) for transformer of capacity 315 KVA to 500 KVA complete all as specified and directed by Engineer-in-charge. |
| 45 | M&L for supplying and refixing in replacement silica cork rubberised gasket, 5mm thick for transformer of capacity 100 KVA to 500 KVAcomplete all as specified and directed by Enginer-in-charge. |
| 46 | M&L for re-streaching of loose LT/HT over head line,aluminium conductor,GI guard wires and credals etc complete at various location and difrent span of 2 to 7 conductors with the help of rope and pullar etc complete all as specified and directed by Engineer-in-charge. |
| 47 | Supply onlyMale and female contacts with moving livers and connectors of HT 11 KV Airbreak switch GOD of 200 amps rating complete all as specified and directed.Note : Fixing only underrelevant items here in after. |
| 48 | Taking out old unserviceable defective HT bushings from transformers by opening carefully primary and secondary terminals top cover conservator tank neutral earth strips and draining out transformer oil to the required level and storing carefullyin cleaned containers for fixing porcelain bushing with brass studs under relevant items of the schedule and supply and fixng minor spares like nuts,rubber bush and washers connecting to winding and reassebling the complete dismantling items with same position, including reconnecting HT and LT sides by relacing suitable nut,bolts and lugs,testing and commissioning the transformer 100 KVAto 200 KVA capacity complete all as specified & directed by Engineer-in- charge. |
| 49 | All as per item No 48 above here in before but HT bush for transformer of capacity 315 KVA to 500 KVA complete all as specified & directed by Engineer-in- charge. |
| 50 | All as per item No 48 above here in before but LT bush for transformer of capacity 100 KVAto 500 KVA complete all as specified & directed by Engineer-in- charge. |
| 51 | Taking out old unserviceable drain cocks from the transformers and Supply and fix new gun metal gate valve 25 mm bore along with brass/ gun metal dummy cap with rubbber washers as required at site complete all as specified & directed by Engineer-in- charge. |
| 52 | Supply and replace silica gel in to the serviceable breathers of transformersall as specified and directed by Engr-In-Charge. |
| 53 | Supply and replace silica gel breather by connecting required short length GI pipe of existing size with conservator oil tank for transformer of capacity 63 KVA to 100 KVA all as specified and directed by Engr-In-Charge. |
| 54 | All as per item No 53 above here in beforebut for transformer of capacity above 150 KVA and up to 630 KVA all as specified and directed by Engr-In-Charge. |
| 55 | M & L for preparation ofold painted surfaces of HT/LT transformers / Voltage stabiliser of capacity 63 KVA to 100 KVA including removing oilly and greasy spots and applying one coats of synthetic enamel paint including white wash to transformer foundation plinth and lettering with white paint as MES NO/SM No, capacity, year of installation, serial No over coat on black paint complete all as specified and directed. |
| 56 | All as per item No 55 here in before buttransformer of capacity exceeding 200 KVA but not exceeding 315 KVA complete all as specified & directed by Engineer-in- charge. |
| 57 | All as per item No 55 here in before buttransformer of capacity 400 KVA to 500 KVA complete all as specified & directed by Engineer-in- charge. |
| 58 | All as per item No 55 here in before but Power transformer of capacity5 MVA complete all as specified & directed by Engineer-in- charge. |
| 59 | Shifting of transformers of capacity 100 KVA to 315 KVA from one location to another location under the area of GE Abohar as required and specified placing in positionincluding making all connections and comissioning complete all as specified & directed by Engineer-in- charge. |
| 60 | Taking down the HT Vacuum circuit breaker/RMU of any type capacity 1250/800/630/400 Amps , 11 KVfor servicing, repairs replacement of defective /worn-out components and reassembling complete comprising of the followingtesting and commissioning to the entire satisfaction of Engineer-in-charge. Note : -(i) Dismantling the VCB//RMU of any type from the enclosure consisting of vacuum interrupter assembly, socket contacts, checking the serviceability of the following parts carefully including cleaning, adjustments, replacements, of defective/won our parts and re-assembling the complete(a) Cleaning the external surface of bushing with CTC or liquid ammonia to remove the accumulation of dirt or any other deposits.Inspection of bushings and make sure that vibration due to break operation have not caused the bushings to move resulting misalignment of contacts.(b) Checking the vacuum/RMU interrupter assembly and contact Checking the alignment of contacts and setting the contact surfaces to bare firm and uniform pressure and adjust the gap as per manufacture tolerance.Badly potted contact needs to be replaced Note Contacts shall be ordered separately (c) Checking the breaker bushing of bus bar and circuit side inspecting the interval surface carefully for any charging/tracking, replacement of bushings.(ii) Dismantling the spring Charging mechanism of VCB/RMU, checking the operations of closing/tripping through closing/tripping coils electrically as well as manual charging including cleaning adjustments and replacement of defective/worn out parts re-assembly complete for the following(a) Checking the ratchet wheel assembly, driving and charging parts including replacement of defective ratchet wheel and like parts(b) Checking the ratchet wheel assembly, driving and charging parts including replacement of defective ratchet wheel and like parts(c) Checking the operation mechanism of breaker and ensure its operation freely through entire stroke.Parts which shows excessive wear and tear to be replaced or adjusted as per manufactures tolerance.(d) Checking of operating voltage watt mechanism terminals tripping arrangement for positive tripping. Contacts to be examined for their condition and operation.Dress the pitted contacts and replace if necessary.(iii) Review the adjustment of all pressure switched land lockout devices.(iv) Inspecting all bolts, nuts pins and collar pins and in place and they are tight and opened properlyNote : Cost of additional hardware like bolts, nuts, washers and springs, washers, petroleum jelly etc, to put the breaker in serviceable condition is deemed to be included in the quoted rate and cost of Inspection, cleaning and re-lubrication of circuit breaker is also included in quoted rates. |
| 61 | Taking down old Protection relay from VCB breaker for repair and maint with replacement of minor spares such as fuse device,DC supply transistor,diaode and other any device to serviceable the specified relay of 3 OC + EF for 18-250 volt DC (Make: ASHIDA Model: ADR241 A or 7SR-210 Siemens Make or P-127 Micom, 220 V DC) 1250/800/630/400 A Capacitycomplete all as specified & directed by Engineer-in- charge. |
| 62 | Taking down old over current and earth fault relay from 66 KV DC control panel for repair and maint with replacement of minor spares such as fuse device,DC supply transistor,diaode and other any device to serviceable the specified relay of Make Avana Model No NPA 422 PF Series-1 complete all as specified & directed by Engineer-in- charge. |
| 63 | Taking down old unserviceable Tripping coil with assembly for 1250/800/630/400 Aand supply and fix new Tripping Coil for630 /400 A Capacity replaced by unseriveable one complete all as specified & directed by Engineer-in- charge. |
| 64 | Taking down old unserviceable Closing coil with assembly for1250/800/630 /400 Aand supply and fix new ClosingCoil for 630 /400 A Capacity replaced by unseriveable one complete all as specified & directed by Engineer-in- charge. |
| 65 | Taking down old unserviceable TNC Switch for breaker control and supply and fix new TNC (Trip, Neatural. Close) Switch for HT Panelreplaced by unseriveable one complete all as specified & directed by Engineer-in- charge. |
| 66 | Taking down old unserviceable indoor VCB/RMU LED Lamps for lightingand supply and fix suitable new LED lamps for HT Panelreplaced by unseriveable one complete all as specified & directed by Engineer-in- charge. |
| 67 | Taking down Old unserviceable Ampere meter and replace by new one complete all as specified & directed by Engineer-in- charge. |
| 68 | M&L for Earthing complete with copper earthplate electrode of size 600 x 600 x 3.15mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to copper strip of size 20 x 3mm earth lead by means brazing after fixing of nuts, bolts, check nuts, washers of galvanised iron steel,protected by galvanized iron pipe 40mm bore (Medium grade) allas directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x 10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel,wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion after taking down old earthing complete all complete as specified and directed. |
| 69 | M & L for removing old unserviceable HT OH linejumpers/connectoers/taps/sleeves of any type and size rejumpering the same by supply and fixing suitable size of ACSR conductor as jumpers and testing the OH lines after reapir/replacement and maint of jumpers all as specified and directed. Note: Connectors/Taps/Sleeves to be paid and measured separately under relevent items of this schedule.Note: Jumpers set of three to be replaced in one job at one pole including in this item. |
| 70 | M&L for repair and maint of HT Air break GOD switch to removing carbon/burnt accessories and replacement of unservceable male and female contacts assembly including applying jelly for contact points and removing/replacement of unserviceable jumpering with new ACSR conductor jumpers and provision for requiered minor spares like screws, nuts, bolts,washers and links are inclusive complete all as specified and directed.Note: Male and female contacts of HT Airbreak GOD switch will be measured and paid separately under relevant item of this schedule. |
| 71 | Laying only old bricks full size or used obtaind from excavation against cable shifting/rerouting complete all as specified and directed. |
| 72 | M&L for emergency maintenance work of HT/LT over head line during breakdown by deploying skilled labour and electricians at faulty site having gang of mimimum 04 persons including transportation and other tools and plant required at site for fault rectification.Note:Contractor or his rep shall come to the site of breakdown within two hours of notification of breakdown.Incase the contractor or his rep shall not come to the site of breakdown and start attending breakdown with in two hours of notification a penalty of Rs 500/- per fault per hour shall be imposed over contractor and same is deducted from his RARs or his deposits. |
| 73 | Material and Labour Framed work of Fe 410-W (Gde-E- 250)quality-A as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete as incompound guards of transformers, four pole/two pole structures in sub stations incuding painting of two coats of enamel paint over one coat of zinc coatingprimer complete all as specified and directed |
| 74 | Material and Labour for MS structrural steel work plates (chequered) channels, square cut or notched (ordinery and counter sunk) forming holes without any attachment(Framed work of Fe 410-W (Gde-E- 250)quality-A for cable duct cover duly provision with lifting handles complete all as specified and directed. |
| 75 | Material and labor for HT cable route indicator cast iron plate round shape of size 150 mm dia bolted with 50 x 6 mm flat iron member of height not less than 1 Mtr embedded in PCC 1 : 3 : 6 type C2 of size 20 x 20 x 30 cm block in trench over the cable route complete all as specified and directed. |
| 76 | Material and labor for filling SF6 gas upto the mark (4 kgper job) to read all electric parameters of the out door SF6 unit of 66 KV grade / 11 KV RMUby bringing a gas cylinder and filling arrangement tools to fill with complete safety measures without long interruption of supply and test the equipment operational and shown on display a healthy parameters all as specified and directed by the Eng-In-charge. |
| 77 | M & L,filling/ laying with aggregate of size 40 mmto the required level ® for outdoor installation yardcomplete all as specified & directed by Engineer-in- charge. |
| 78 | Repair/ maintenance and servicing of Servo Voltage Motor operating Oil Immerged Voltage Stablizer 3 phase 415 volts 50 HZ of capacity 30 to 120 KVA and Comprising following work services complete all as specified and directed by Engineer-in-Charge :-(a) Disconnection carefully in put & out put cable connection and foundation it any and transporting to trade work shop for repairs.(b) Opening of Top cover by removing nuts bolts and all mounting accessories etc.(c)Draining out stabilizer oil and keeping aside in barrel for reuse and then again pouring back after necessary filteration, Dehydration and dehydration including top-up with new oil to make up the reduced quantityafter dehydration dielectric strength of Oil should be 40 KV.(d) Replacement of gas ket(e) Servicing of parts complete including cleaning and polishing the contact points.(f) Labour only for cleaning the internal body complete, under voltage coil with insulators,Servo motor, Volt meter , switches, dimmer state with PCB board etc.(g) Replacing unservicible nut bolts as required and as directed by Engr-In-Charge.(h)Reconnectingof all in out put contact points and refixing top cover after replacement of gas kit extra.(j)Transporting Stablizer backto the respective site connecting in put & out put cable testing & commencing.Note : Spareparts (IF required) will be measured & paid separately under relevant item of this schedule at \" Supply only\" rates. |
| 79 | All as per item no-78 but for Stablizer of 10 KVA capacity complete all as specified & directed by Engineer-in- charge. |
| 80 | Supply only under voltage coil with insulator suitable for stabilizer of capacity30 to 120 KVAcomplete all as specified and directed by Engineer-in-Charge. |
| 81 | Supply only under voltage coil with insulator suitable for stabilizer of capacity 10 KVAcomplete all as specified and directed by Engineer-in-Charge. |
| 82 | Supply only servo motor suitable for30 to 120 KVA complete all as specified and directed by Engineer-in-Charge. |
| 83 | Supply only servo motor suitable of 10 KVA complete all as specified and directed by Engineer-in-Charge. |
| 84 | Supply only volt meter with selector switch 0 to 500 V complete all as specified and directed by Engineer-in-Charge. |
| 85 | Supply only dimmer state with PCB board suitable for30-120 KVA DG set.complete all as specified and directed by Engineer-in-Charge. |
| 86 | Supply only dimmer state with PCB board suitable for 10 KVA DG set. complete all as specified and directed by Engineer-in-Charge. |
| 87 | Preparation of old painted surface by steel brushing / cleaning stain gresy spot with thimmerand applieying two coats of spray painting (synthetic enamel paint) all sides with spraying machine to servo voltage stablizer of capacity 30-120 KVA. complete all as specified and directed by Engineer-in-Charge |
| 88 | Preparation of old painted surface by steel brushing / cleaning stain gresy spot with thinder and applieying two coats of spray painting (synthetic enamel paint) all sides with spraying machine to servo voltage stablizer of capacity 10 KVA. complete all as specified and directed by Engineer-in-Charge |
| 89 | M & L ,Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11metres long) Note:- For Raw water line along the FZK Abohar roadas intermidiate pole to maintain over sagging of existing HT 11 KV Cable on pole. |
| 90 | M&L for cement concrete in foundations, filling and mass concrete type D2 1:4:8 with 40 mm graded stone aggregate for foundation of pole etc complete all as specified & directed by Engineer-in- charge. |
| 91 | M&L for providing PCC 1 : 3: 6 type C2 using 40mm graded stone aggregate as foundations, filling and mass concrete complete all as specified & directed by Engineer-in- charge. |
| 92 | M&L for providing cement concrete type B1, 1:2:4 using 20 mm stone aggregate in coping or chamfered on edges complete all as specified & directed by Engineer-in- charge. |
| 93 | M & L ,in repair, Greacing , replacing wheel Hub Ball bearing , check nuts ,tubeflap,rectifying punchatr of tube of Trolley incl Air filling,body denting ,applying metal putty,painting andwriting MES NO/SM NO in standard size complete all as specified & directed by Engineer-in- charge. |
| 94 | Supply and fix Galvanised steel wire 3.15 or 4mm dia for earth wire complete all as specified and directed. |
| 95 | Supply & Laying rubber mattings electrical insulation, 11 KV of size 1 mtr X 2 mtr X 2.5mm for installationscomplete all as specified & directed by Engineer-in- charge. |
| 96 | Supplyingrubber hand gloves, 11 KV/ 15 KV complete all as specified & directed by Engineer-in- charge. |
| 97 | M & L in repairHT Back coonector plate for G.O Switch complete all as specified & directed by Engineer-in- charge. |
| 98 | Taking down old burnt 11 KV Fuse elements and supply& fix new D.O Fuse of capacity 2.5 Amps to 25 Amps complete all as specified & directed by Engineer-in- charge. |
| 99 | Taking down old U/S 11 KV Drop out contactand supply& fix new Drop out fuse top contact complete all as specified & directed by Engineer-in- charge. |
| 100 | Taking down old U/S 12KV brass stemand supply& fix new HV 12 KV /250Amp brass metal set stem as per IS complete all as specified & directed by Engineer-in- charge. |
| 101 | Taking down old U/S 1.1KV brass stemand supply& fix new LV 1 .1 KV /250Amp brass metal set stem as per IS complete all as specified & directed by Engineer-in- charge. |
| 102 | Taking down old U/S 1.1KV brass stemand supply& fix new LV 1 .1 KV /400Amp brass metal set stem as per IS complete all as specified & directed by Engineer-in- charge. |
| 103 | M & L ,Weeding spray,using spray pump andchemicalwith reqd safety precausion for installation yard complete all as specified & directed by Engineer-in- charge. |
| 104 | Taking down old U/S 11 KV Drop out contactand supply& fix new Drop out fuse bottom contact complete all as specified & directed by Engineer-in- charge. |
| 105 | Supply and laying DWC pipe of size outer dia 90 mm , inner dia 76mm for the protection of cable including all fittings complete all as specified & directed by Engineer-in- charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail