| 1 | Dismantling / taking down BER submersible/ monoblock/ centrifugal and any type of pumping set of any model/ make size 3 HP to 20 HP cap after necessary removal of electrical, starter connections, demolition of PCC and water connections from existing location at site and making good finishing of walls, UG Sump etc including shifting /transporting to MES store yard for depositing complete all as specified and as directed. |
| 2 | Supply and install, testing commissioning of submersible pump set 7.5 HP, 3 Phase stage 16 delivery dia 50mm including suitable FASD starter complete all as specified and as directed.Make:- Kirloskar Cat No KS6B-0815 or equivalent |
| 3 | Supply and install, testing commissioning of submersible pump set 10 HP, 3 Phase stage 16 delivery dia 50mm including suitable starter complete all as specified and as directed.Make:- Kirloskar Cat No KS6B-1016 or equivalent |
| 4 | Supply and install, testing commissioning of submersible pump set 15 HP, 3 Phase stage 30 delivery dia 50 mm including suitable FASD starter complete all as specified and as directed.Make:- Kirloskar Cat No KS6B-1530 or equivalent |
| 5 | Supply and install, testing commissioning of horizontal open well submersible pump set 20 HP, 3 Phase delivery dia 100x100 mm, head 38 mtrs delivery 75 Cum/ hr including suitable starter complete all as specified and as directed.Make:- Kirloskar Cat No KS6B-1530 20 100x100 3P CII or equivalent |
| 6 | Supply and install, testing commissioning of horizontal open well submersible pump set 10 HP, 3 Phase delivery dia 65 x 50mm, head 45 mtrs delivery 23 Cum/ hr including suitable FASD starter complete all as specified and as directed.Make:- Kirloskar Cat No JOS 1065 10 65x65 3P CII or equivalent |
| 7 | Supply and install, testing commissioning of horizontal open well submersible pump set 7.5 HP, 3 Phase delivery dia 65 x 50mm, head 45 mtrs delivery 25 Cum/ hr including suitable FASD starter complete all as specified and as directed.Make:- Kirloskar Cat No-JOS 854 7.5HP 65x50 3P CII or equivalent |
| 8 | Supply and install, testing commissioning of horizontal open well submersible pump set 5 HP, 3 Phase delivery dia 65 x 50mm, head 30 mtrs delivery 27 Cum/ hr LPM including suitable FASD starter complete all as specified and as directed.Make:- Kirloskar Cat No-JOS 550 5.0 65x50 3P CII or equivalent |
| 9 | Supply and install, testing commissioning of horizontal open well submersible pump set upto 3 HP, 3 Phase delivery dia 65x50mm, head 20 mtrs delivery 23 Cum/ hr LPM including suitable FASD starter complete all as specified and as directed.Make:- Kirloskar Cat No JOS 335 3.0 65x50 3P CII or equivalent |
| 10 | Supply and install, testing commissioning of suction sweepers with centrifugal pumpset 2 HP, 3 Phase including suitable FASD starter with channel mounted, easily movable Gland packed/ mechanical seal, 50HZ/60HZ availability good suction performance and low NPSH vibration free performance complete all as specified and as directed. |
| 11 | Supply and install, testing commissioning of blower pump for filter plant (air compressor) of capacity 5 HP including suitable FASD starter complete all as specified and as directed. |
| 12 | S & F water proof submersible cable 3 core flat copper conductor, PVC insulated 1100 volts grade, protected by means of metal clip alongwith the pump body and connected to pump motor through water tight sealing joints complete all as specified and as directed at site by the Engr-in-Charge of the following sizes:- Make:- finolex/ polycab/ Havells |
| 13 | 4 Sqmm 3 Core |
| 14 | 6 Sqmm 3 Core |
| 15 | Supply, laying, jointing, welding & testing MS Pipe (Heavy duty class \"C\") laid in trenches or on floors for connections to pump sets for suction, pump to header and to connect out going water main CI/DI/MS pipe line including taking down old unsv MS pipe any size complete all as specified and as directed.Note:- MS Flanges and Flange joints complete with jointing materials shall be measured and paid separetely. |
| 16 | 80 mm bore |
| 17 | 100 mm bore |
| 18 | 150 mm bore |
| 19 | 200 mm bore |
| 20 | S & F, MS flanges of following sizes not less than 16 mm thick duly welded on ends of MS pipe complete all as specified and as directed. |
| 21 | 80 mm bore |
| 22 | 100 mm bore |
| 23 | 150 mm bore |
| 24 | 200 mm bore |
| 25 | M & L for Flanged Joints with rubber or fibre board gasket including nuts, bolts and double washers of following sizes complete all as specified and as directed. |
| 26 | 80 mm bore |
| 27 | 100 mm bore |
| 28 | 150 mm bore |
| 29 | 200 mm bore |
| 30 | Supply, errection, testing and commissioning of 16 Mtr high mast, suitable for 180 Km/ hr wind speed continuously tapered, polygonal cross section, not less than 20 sided manufactured from MS plates, hot dip galvanized complete with all its accessories and including LED Luminaries suitable for mounting 08 Nos of 200 Watt consisting of head frame, pully assembly, motorized movable lantern carriage, double drum winch, 3/4 point suspension system with SS wire rope 6mm dia 7/19 gauge, trailing cable-5 core x 4sqmm, with integral power tool and control panel housing with suitable control gears and circuit for the operation of high mast complete all as specified and as directed. |
| 31 | The rate quoted is inclusive for the following:-(a) Design and casting of suitable shallow foundation with M-25 concrete for the high mast considering the safe soil bearing capacity at site as 10 Ton per square meter at 2m depth, design factor for safety 1.2, considering wind speed (Km/hr) is 180 (IS 875, 1987) and depth of foundation as per manufacturer instruction/design and min 12 Nos of foundation bolts (dia minimum 25mm).(b) Aviation obstruction lights with one numbers of LED lights fittings complete.(c) Supply and erection of hot dip galvanised lightning arrestor with 32X6 mm hot dip galvanised strip down conductor upto ground level.(d) Supply, installation, testing and connecting to electical system distribution board (outdoor type - 01 No on each high mast pole) suitable size, factory made, double door, cubical and pedestal type, compartmentalised design, back door hinged type & openable, fabricated out of 3.15 mm thick CRCA steel sheet, weather/ dust/ vvermin proof, IP 65 protection, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one number lock with duplicate key duly painted with power coated paint and providing the following items including connection of all incoming and outgoing cables using suitable size lugs and glands, danger notice board, with supporting legs of angle iron of size 50 x 50 x 6mm of length 100 cm long duly grouted in PCC (1:3:6), 50cm below ground level and 50cm above ground with 1 No 32A TPN MCB Incomer, Single dial time switch, 22A TP Contactor for automatic switching on luminaries, power tool control with 2 No 9A contactors and raise lower push button, incoming 25 sq.mm and outgoing 16 & 2.5 sq.mm terminals, complete all as speccified and directed.(e) Connecting to GI Earthing 2 sets required along with GI 32x6 Flat. Design and drawings of the foundation shall be prepared as recommended by the OEM and be got approved from Engr-in-Charge before commencement the work and the rate quoted is deemed to including for the same.(f) Excavation, PCC, nuts, bolts etc retun filing, removal all shall be deemed to be included in quoted rates as per specifications/ foundation drawing of manufacturer. |
| 32 | S & F LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.Make:- Crompton Cat No-LFLN-200-CDL/60-HPM/ Bajaj Cat No-GLEAM-G F 240L WH NB-AS PC SD/ Eveready Cat No-LEDFL20015-03L. |
| 33 | Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in soft/ loose soil getting out and levelling of bottom surface to required level complete all as specified and as directed. |
| 34 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 Cm thick soft / loose soil complete all as specified and as directed. |
| 35 | Removing excavated material (Soils) from site to a distance not exc 50 M away and depositing where directed at a level not exc 1.5mtr above the starting point complete all as specified and as directed. |
| 36 | M & L burnt bricks sub class \"B\" old size laid in trenches with equal to length of bricks across the cable for cable protection complete all as specified and as directed. |
| 37 | Fine Seived excavated dry soil laid to the required width of trench at botom and top of cable as cushioning complete all as specified and as directed. |
| 38 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25sqmm 4 core complete all as specified and as directed. |
| 39 | Supply & laying 50mm HDPE pipe heavy grade for cable protection complete all as specified and as directed. |
| 40 | Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm buried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to the galvanised iron strip 32 x 6mm size by means of bolts, nuts, check nuts and washers of galvanised iron and 32x6mm GI strip protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit in PCC1:2:4 type B-1, using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kgs/ Sqm and 6mm dia bar handle, excavation and earth work in any type of soil, charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mesh and medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No.3 of MES Such 2009 Part-I complete all as specified and as directed. |
| 41 | Boring holes under road pavement by bocky manually in any type of soil upto 200mm bore complete all as specified and as directed. |
| 42 | Supply, errection, testing and commissioning of 15W LED warm white bollard in unique traingular design with IP-65 protection in and including suitable size of 0.30x0.30x0.45 cm foundation complete all as specified and as directed.Make:- Bajaj Tllum 15W 30 K 80 C3 GW S or equivalent |
| 43 | Supply, errection, testing and commissioning of 20W LED garden lights IP-54 Castor black post light fixture 3 mtr long dimension of D-230mm H-3000mm including 20W Warm white LED lamp, holder and suitable size of 0.30x0.30x0.45 cm foundation complete all as specified and as directed.Make:- Luker cat No-LBF028E27 BK or equivalent. |
| 44 | Boring holes under road pavement by bocky manually/ mechanically in any type of soil without distrubing road/ footpath etc upto 80mm bore complete all as specified and as directed. |
| 45 | Supplying and fixing of pole mounted sheet moulded compound (SMC) box weather proof type with hinged type door off white color of size 150 X 100 X 290mm (LxBxH) comprising of 1 No MCB 6A and 1 No neutral link, three phase and one neutral link 63A connector blocks (heavy duty) bottom to top open front door complete fixed on pole/wall with suitable two nos clamps, bolts, nuts and suitable size stainless steel cable glands complete all as specified and as directed. |