| 1 | M&L for brick work with sub class \"B\"brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 including all quoins, arches, pillars incl demolition of old existing brick/stonework etc complete all as specified and directed. |
| 2 | All as per item No.01 above but(Except bricks) straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 including all quoins, arches, pillarsincl demolition of old existing brick/Stone work etc,complete all as specified and directed. (Using old bricks obtained from demolition) |
| 3 | M&L forbrick work with sub class \"B\"brick straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick wallincluding demolition of existing brick work or stone masonary built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed. |
| 4 | M & L for 15 mm thick rendering on brick/stone work or concrete surface in cement mortar 1:4, surface finished even and fair mixed with water proofing compound as per manufacture instruction complete all as specified & directed. (WPC will be measured & paid separately under respective item of the BOQ) |
| 5 | M & L for 15 mm thick renderingon brick/stone work or concrete surfacein cement mortar 1:6, surface finished even and fair complete all as specified and directed. |
| 6 | M & L for 15 mm thick rendering on brick/stone work or concrete surface in cement mortar 1:4, surface finished even and fair mixed with water proofing compound as per manufacture insturction incl taking down old cement plaster complete all as specified & directed.Note: Water proofing compound will be measured & paid separately under respective item of the schedule. |
| 7 | M & L for 15 mm thick rendering on brick/stone work or concrete surfacein cement mortar 1:6, surface finished even and fair incl taking down old cement plaster complete all as specified and directed. |
| 8 | M & L for 5mm thick rendering on celing surface in cement mortar 1:3, finished even and smooth without using extra cement incl taking down old plaster complete all as specified and directed. |
| 9 | Supply only liquid water proofing compound complete all as specified and directed. |
| 10 | M&L for preparation of wall and applying a layer of wall care putty1.50mm thick to make the surface smooth complete all as specified and directed. |
| 11 | M&L for complete removal existing treatment from walls and applying two coats oil bound distemper any tint on walls including preparation of surface complete all as specified and directed. |
| 12 | M&L for applying two coat of exterior weather proof 100% anti fungal acrylic smooth emulsion with silicon additives that offer anti alge high performance exterior wall finish with 6 years of performance warranty by manufacturer applied by using Airless spray technology with max working pressure of 3300 PPSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacture with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper, should be able to spray in hard to reach areas and penetration of distemper on the surface to achieve excellent application using limited manpower incl preparation of surfaces complete all as specified and directed. |
| 13 | M & L forapplying one coat of white wash on old decorated surface of ceiling including preparation of surfaces complete all as specified and directed. |
| 14 | M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. |
| 15 | M&L for preparation of newly plastered surface of wall and applying two coat of cement base paint over a coat of primer complete all as specified and directed. |
| 16 | M&L for preparation of newly plastered surface of ceiling and applying two coat of white wash complete all as specified and directed. |
| 17 | M&L for complete removal/ demolition of existing treatment of sunken portion such as WC & bath and carried out sunken treatment as per following:-(a) Clean the complete surfaces including rubbish for sunken and washing down with water.(b) Plaster for sunken portion in CM (1:3) with WPC (Dr. Fixit or equivalent) as per manufacturer\"s instructions.(c) Preparation of surfaces and applying one coat of polymeric primer @ 0.30 Kg/Sqm.(d) Supply and providing APP based polymeric water proofing members 3 mm thick of weight not less than 3.00 Kg/ Sqm.(e) Applying one coat of bitumen 85/25 @ 1.2 Kg/Sqm.(f) PCC 1:5:10 mixed with brick bats 40 mm size.(g) 40mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) finish even and smooth (h) Poinding test carried out upto 1 to 7 days . |
| 18 | M&L for 25mm thick PCC 1:2:4 type B-0 (using12.5 mm graded stone aggregate) as in floor incl demolition old existing concretecomplete all as specified and as directed. |
| 19 | M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (Square/reangular) area of each tiles exc 0.11 sqm but n exc 0.18 sqmin floor, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tile laid over and including 15 mm thick screed bed in cement mortar 1:4incl dismantling old existing tiles complete all as specified and directed. |
| 20 | M&L for glazed ceramic coloured tiles of size 350x250x7mm/450x350x7 mmthick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tile fixed over and including 10 mm thick rendering in cement mortar 1:4 incl dismantling old existing tiles complete all as specified and directed. |
| 21 | M&L for 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar work/places, laid in alternate bays and filling the joints with & including bitumen and sand 1:3 by weight, surface finished even and fair without using extra cementincl demolition old existing concrete complete all as specified and directed. |
| 22 | M&L for 18-20mm thick Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match withshade of granite incl dismantling old stone complete all as specified and directed. |
| 23 | M&L for grinding and polishing to edges and rounding of granite kota or marble slab and smooth finishing complete all as specified and directed. |
| 24 | Taking down chowkhats or frames n. exc 1.5 sqm each without taking off shutter from the frame complete all as specified and directed. |
| 25 | Taking down chowkhats or frames exc 1.5 sqm but n exc 4.0 sqm each without taking off shutter from the frame complete all as specified and directed. |
| 26 | S&F 24 mm thick moulded WPC factory made 100% solid door (conforming as per IS-4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10 mm deep mould on single side with wood grain texture and back side plain with density not less than 600 Kg/cum.Manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, fireetardant and having screw holding capacity complete all as specified and directed. |
| 27 | S&F factory made 100 % solid wood plastic composite (WPC) door frame 75x50 mm made from wood plastic composite (single extruded process) material with density 780 Kg/Cum from ISO certified company door should be water proof, termite proof, fire retardant and having good screw holding capacity complete all as specified and directed. |
| 28 | S&F 18 mm thick WPC board one side prelaminated and other side plain white colour as in cup board shutters and frames, kitchen cabinet frontshutter, partion, shelf, & drawer, fixed with screws, solvent cement / adhesive incl dismantling of old unserviceable existing board complete all as specified and directed. |
| 29 | S&F 18 mm thick WPC board both side plain white colour as in cup board shutters and frames, kitchen cabinet frontshutter, partion, shelf, & drawer, fixed with screws, solvent cement / adhesive incl dismantling old existing board complete all as specified and directed. |
| 30 | S&F magnetic catcher and striking plate including letting in and fixed complete all as specified and directed. |
| 31 | S&F Continious (PIANO) hinges, mild steel, bright finish or electrogalvanised. 30 mm width of flaps (when open) complete allas specified as directed. |
| 32 | S & F stainless steel barrel tower bolts 150 mm long one piece and fixed complete all as specified and directed. |
| 33 | S & F stainless steel butt hinges, medium weight 100 mm long one piece and fixed with screws/welded to frame complete all as specified and directed. |
| 34 | S & F stainless steel handles 150 mm long one piece and fixed with screws/welded to frame complete all as specified and directed. |
| 35 | S & F stainless steel handles 125 mm long one piece and fixed with screws/welded to frame complete all as specified and directed. |
| 36 | S & F 300 mm long stainless steel sliding door bolt (bolt not less than 12 mm dia) with hasp & staple and fixing clips of SS sheet, and SS fixing boltsand fixed complete all as specified and directed. |
| 37 | S&F power coated ventilator fixed type and frame made with aluminium section with and including partly glass and partly stainless steel wire mesh and including aluminium grill of aperture not more than 40 sqcm (as specified below), aluminium sections shall be of size as given below including taking down old window/ventilator etc complete all as specified and directed by Engineer in Charge. Frame : 44.5 x 44.5 mm x 1.98 mm thick including 5mm thick frosted glass fixed with rubber gasket with aluminium beading and stainless steel wire mesh of 0.63 mm nominal dia wire and average width of aperture 1.40 mmNote :- (i) Making good of wall surface withmatching to existing surface witout any extra cost (ii) Cost of glass and gauge shall be included in the quoted rate. |
| 38 | Taking up or down PPR/ steel tubing and connection incl removal from site bore of pipe 15mm dia complete all as specified and directed. |
| 39 | Taking up or down PPR/ steel tubing and connection incl removal from site bore of pipe 20mm dia complete all as specified and directed. |
| 40 | S&F 15mm bore pipe medium grade galvanised iron with all fittings fixed to wall and ceiling or laid in floor complete all as specified and directed. |
| 41 | S&F 20 mm bore pipe medium grade galvanised iron with all fittings fixed to wall and ceiling or laid in floor complete all as specified and directed. |
| 42 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed. |
| 43 | S&F in repairs PVC connection 15 mm dia 450 mm long with brass fly nut at both endscomplete all as specified and directed. |
| 44 | S & F in repairs vitreous china wash down water closet pedestal pattern white (excluding flushing cistern and flush pipe) with CI ‘P’ or ‘S’ trap excluding plastic white sheet cover, CP jet spray with 1.0 metre long PVC pipe, connecting to stack pipe and to flushing pipe and complete including making good to floor complete all as specified and directed. |
| 45 | S&F in repair full stall china urinals (wall type) complete incl plugs, bedding urinal to plugs with and incl 60 mm long screws, pointing around urinal back in cementand waste pipe etc complete all as specified and directed. |
| 46 | S&F in repair plastic water closet seat cover, white, closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 47 | S & F in repair vitreous china squatting pan “ORISSA PATERN” of size 580x440mm, white, with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified and directed. |
| 48 | S & F in repair 10 litre capacity PVC low level cistern ‘ white’ with inlet, float valve including brackets with 32 mm dia PVC pipe/bend 600 mm long complete all as specified and directed. |
| 49 | S & F in repair75 mm bore UPVC (SWR) pipe pressure 4kgf/cm2 single socketed in any length with rubber ring, fixed on wall / laid in trenches complete all as specified and directed. |
| 50 | S & F in repair 110 mm bore UPVC (SWR) pipe pressure 4kgf/cm2 single socketed in any length with rubber ring, fixed on wall/ laid in trenchescomplete all as specified and directed. |
| 51 | S & F in repair 75 mm diaPVC (SWR) bends complete all as specified and directed. |
| 52 | S & F in repair 110 mm diaPVC (SWR) bends complete all as specified and directed. |
| 53 | S & F in repair75 mm bore PVC (SWR) junction double, (double T) equal or unequal complete all as specified and directed. |
| 54 | S & F in repair110 mm bore PVC (SWR) junction double, (double T) equal or unequal complete all as specified and directed. |
| 55 | S & F in repairvitreous china wash hand basin counter top size 550x400mm fixed with waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified and directed. |
| 56 | S&F in repair 15mm dia brass chromium plated centre hole wash basin/ sink mixer with accessories in wash basin for mixing hot and cold water, screwed down for 15 mm dia bore GI Pipe complete all as specified and directed. |
| 57 | S&F in repair brass chromium platedovehead shower with shower arm complete all as specified and directed. |
| 58 | S&F in repair 15 mm bore Angle cock/stop valves, cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 59 | S&F in repair 15mm bore Bib taps long bodycast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 60 | S&F in repair 15mm bore Stop cock concealed typefancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 61 | S&F in repair gun-metal globe or gate valve with iron wheel head,screwed both ends for iron pipe complete all as specified and directed. |
| 62 | S&F in repair CP Health Faucet with 1.20 mtr chromium plated metalic expandable tube & hook complete all as specified and directed. |
| 63 | S&F CP grating 100mm to 125 dia round fixed to floor/ nahani trap with hole/without fixed with cement mortar, complete all as specified and directed. |
| 64 | S&F in repair looking mirrorselected quality glass,8mm thick fixed to wall with fixing arrangement complete all as specified and directed. |
| 65 | S & F in repair 20 mm dia brass chromium plated towel rack of 3 sets type 60cm long between flanges including pair of fixing brackets complete all as specified and directed. |
| 66 | S&F in repair 32 mm waste fittings/ coupling brass, chromium plated for wash hand basin, basins, etc. with long screwed shanks and fly-nuts complete all as specified and directed. |
| 67 | S&F in repair 32 mm dia PVC waste pipe for WHBand sink 90 cm long with union, complete all as specified and directed. |
| 68 | S&F in repair CI spun casted floor trap with grating including jointing with solvent cement 75mm bore outlet complete all as specified and directed. |
| 69 | S & F rotational moulded polyethylene water storage tanks Capacity of tank 1000 litres tripple layer, white colour,(cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including dismantling of existing unserviceable tank and removing from site, complete all as specified and directed. |
| 70 | S & Fin repairs ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed for 20 mm bore size (Minimum weight 210 gms) complete all as specified and directed. |
| 71 | M & L for RCC1:2:4 (nominal mix) type B-1 (using 20 mm gradedstone aggregate) as in slabs supported on wall, beam and columns in floors, roof slabs, shelves and cover slab Including necessary form work and demolition of existing old RCC complete all as specified and as directed. |
| 72 | S & F mild steel TMT bar 6-8 mm dia, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed. |
| 73 | M&L for 70 mm thick vibromatic reinforcedcement concrete precast 1:2:4 (using 20mm graded stone aggregate) with 1mm thick mild steel CR sheet around painted with 2 coats of bituminous paint ,as in drain cover slabsfinish fair even and smooth without using extra cement incl form work and 10 mm dia bar spacing of bar100mmc/cincluding , 100 mm long handle of 12mm dia round bar counter sunk by 25mm welded to reinforcement completeall as specified and directed |
| 74 | M & L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in benching to drain, holdfast, padding to roof/chhajja, coping, bed block etc. and the like edge slightly rounded or chamfered including necessary use and waste of form work and demolition of existing old cement concrete (un-reinforced) not exc 15 cm thick inground floor and paving below or above ground level complete all as specified and directed. |
| 75 | Taking down carefully copper /aluminium point wiring (light, fan , socket or power ) any type including unscrewing from board,fitting and fixture such as switches, ceiling roses, holders, regulators sockets ,light fittings etc removing materials from site and making good disturbed with the existingsurfaces complete all as directed. |
| 76 | M&L for point wiring with1.5 sq mm PVC insulated, unsheathed, stranded copper conductor (FRLSH) cable single core 1100 Volt grade in and including rigid PVC conduit medium grade 20mm dia or more ISI Marked concealed / Surface conduit as per existing and conduit accessories and cutting chases of suitable girth where required on brick/concrete surface &making gooddisturbed surface,provision of CI/Pressed steel terminal switch box with plastic laminatedsheet 3 mm thick fixed with brass screw and washers along with 1.5 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLS H) as earth wire connected with main common earth dolly complete all as specified and directed for the following :- |
| 77 | One light/fan/bell/exhaust fan point controlled by one, one-way switch 5/6 Amp. |
| 78 | One 3pin 5 Amps socket out let on same board controlled by one, one-way switch |
| 79 | One 3pin 5 Amps socket out let onindependent board controlled by one, one-way switch |
| 80 | All as per item No.76 here in before but point wiring with 2.5 sqmm multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm PVC insulated multi strand copper conductor cable as continous earth wire. Note: ( In One ckt of onepoint only) |
| 81 | All as per item No 76 abovebut point wiring with 4.0 sqmm multistrand copper conductor cable and 4.0sqmm PVC insulated multi strand copper conductor cable as continous earth wire for 15 Amps power point. |
| 82 | S&F switch Piano flushtype single pole one way230 Volts 6 Amps complete all as specified and directed. |
| 83 | S&F switch Piano flushtype single pole one way230 Volts 15 Amps complete all as specified and directed. |
| 84 | S&F Socket outlet 3 pin , 230 Volts 5/6 Amps multipurpose 5 pin complete all as specified and directed. |
| 85 | S&F Socket outlet multipurpose having provision for 3 pin, 230 Volts 15/16 Amp and 3 pin, 5/6 Amp, piano flush type complete all as specified. |
| 86 | S&F ceiling rose 3 terminal / PVC/ polycarbonate, isolated body ISI marked all as specified and directed. |
| 87 | S&F batton holder ISI Marked mounted on wall including 09 Watt LED Bulbcomplete all as specified and directed. |
| 88 | S&F in replacement energy efficient LED tube light fitting20 watts, 230 volts with efficiency of not less than 100 lumensper watt, PC extruded body with PC diffuser including connecting up with three core flexible copper conductor cable of suitable size from ceiling completeall as specified and directed.. |
| 89 | S&F in replacement mirror light decorative compact luminaries with decorative ends caps incl9/10 Watt LED with all accessories and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 90 | S&F sub main wiring with two single core 4 sqmm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium gradesurface on wall along with 4 Sqmm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected withmain earth dolly including cutting chasing and making good disturbed portionand taking down old unserviceable wiring complete all as specified and directed. Note:03 runs of copper cable and 01 run of conduit will be measured as 01 RM unit length. |
| 91 | S&F sub main wiring with two single core 6.0 sqmm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 25mm dia or more medium gradesurface on wall along with 6.0 Sqmm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected withmain earth dolly including cutting chasing and making good disturbed portionand taking down old unserviceable wiring complete all as specified and directed. Note:03 runs of copper cable and 01 run of conduit will be measured as 01 RM unit length. |
| 92 | S&F in replacement sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 8 way with 200 Amps rated busbar all complete all as specified and directed. |
| 93 | S&F in repair MCB SP 6 to 32 Amp \"C\" series 10 KA repturingcapacity complete all as specified and directed. |
| 94 | S&F in repair MCB SPN40 Amp 240 V AC 10 KA repturingcapacity complete all as specified and directed. |
| 95 | S&F in replacement sheet metal enclosure double door type for MCBs DB TPN 415V AC 4 way with 200 Amps rated bus bar complete all as specified and directed. |
| 96 | S&Fin repair MCB TPN63 Amps rating 240V, 10KA \"C\" curve complete all as specified and directed. |
| 97 | S&F in replacement for Distribution Box MCB Procted socket with sheet steel enclosure 20 A MCB DBOXX Combo DP including PLUG TOP complete all as specified and directed. |
| 98 | S&F electric water heater storage type, ABS Body with Glass lined tankand heating element upto 2KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve thermostate NRV connection piece complete all as specified and directed. |
| 99 | S&F exhaust fan steel body AC Single phase,230 voltof size 300 mm sweepwith blades, and frame and louvers with all fittings complete allas specifiedand directed. |
| 100 | Taking down exhaust fan from building and keep in safe custody and again refixing the same after servicing / greasing etc as directed by Engr- in -charge. |
| 101 | M&L for earthing complete with galvanished steel earth plate electrode 600x600x6.0 mm thick buried directly in ground and earth pit not less than 2.25 mtr deep below natural ground level and top edge of the plate not less than 1.5 Mtr deep below natural ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Pt-I connected to earthing testpoint all as specified or indicated including testing on completion, surrounded with adequate qty of char coal dust mixed with salt to a packed thickness not less than 15 Cm on all sides of earth plate incl excavation, earth work, returning filling in, removal of surplus soil to a distance n.exc. 50 mtr, incl GI pipe watering light grade with CI funnel and wire mesh and PCC 1:2:4 type B-1 as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1 duly re-enforced with MS bar 6mm dia @ 150mm C/C both ways with 10mm dia MS bar lifting handles, complete all as specified and directed. |