| 1 | Taking down cement or cement lime plaster of any description on any type of walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 2 | M & L for rendering 15mm thick in cement mortar 1:4 on stone walls or other than fair faces of brick walls fiinished even and smooth without using extra cement, complete all as specified and directed. |
| 3 | M&L for preparation of new plastered wall surface including cornices etc and applying two coats of exterior emulsion all weather proof paint of Apex Ultima of ASIAN or equivelent make of any approved two or more colour pattern as approved by GE over and including a coat of primer, complete all as specified and directed. |
| 4 | M&L complete removal of existingtreatment of wall surfaces,preparation ofplastered or unplastered or untreated wall surfacesincluding cornices etc and applying two coats of exterior emulsion all weather proof paint of Apex Ultima of ASIAN or equivelent make of any approved two or more colour pattern, complete all as specified and directed. |
| 5 | Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillers etc, complete all as specified and directed. |
| 6 | M & L for Brick work with sub-class `B\" bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6,complete all as specified and directed. |
| 7 | All as per Item No 6.00 here-in-before but except bricks. |
| 8 | M & L for providing plain cementconcrete type B-1, 1:2:4, (using 20 mm graded stone aggregate), as in coping, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required, complete all as specified and directed. |
| 9 | Demolition of RCC of any description and in any position not therwise specifically provided for, complete all as specified and directed. |
| 10 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m indepth; for foundation, etc. or for shafts, wells, cesspits, anholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil, complete all as specified and directed. |
| 11 | M&L for plain cement convrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in fondation, filling and mass concrete, complete all as specified and directed. |
| 12 | M & L for providing RCC M-25 design mix (using 20 mm graded stone aggregate) as in foundation including rafts, footing, foundation beams, plinth beams, base of columns and the like, complete all as specified and directed. |
| 13 | M & L for providing RCC M-25 design mix (using 20 mm graded stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed. |
| 14 | M & L for providing RCC M-25 design mix (using 20 mm graded stone aggregate) as in Columns, pillars, piers, posts and struts, complete all as specified and directed. |
| 15 | Returning & filling of the excavated earth including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils, complete all as specified and directed. |
| 16 | Removing excavated soils not exc 50 mand depositing where directed at a level not exc 1.5 m above the starting point, complete all as specified and directed. |
| 17 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surfaces of concrete, complete all as specified and directed. |
| 18 | Formwork to sides ofsquar ,rectangular or polygonal pillars, posts, struts, piers, columns and stanchions rough finished surfaces of conrete flat, complete all as specified and directed. |
| 19 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc rough finished surfaces of conrete flat,complete all as specified and directed. |
| 20 | M&L for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia or securing with clips,complete all as specified and directed. |
| 21 | All as per Item No 20.00 here-in-before but 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders. |
| 22 | S&F in repair galvanised, 2 strand, steel barbed wire 2.24mm dia with 2mm barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc as directed (each line wire to be measured), complete all as specified and directed. |
| 23 | M&L for Concertina coil 1050mm dia, 56 loop, 2.5mm core wire heavy galvanished (wire-275 GSM & strip-200 GSM), tensile strengthof wire 1400-1500 N/Sqmm, wight 14.63 Kg/coil, stretchable length 12M including securing or tying at crossings with and provision of galvanised mild steel wire, staples ot steel pins etc, complete all as specified and directed. |
| 24 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 25 | S&F angle iron posts or struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling,boltingor riveting, etc, and grills and grating and for iron frame works similar work conforming to Fe-290 Gde E-165, complete all as specified and directed. |
| 26 | M&Lfor preparation of new steel surfaces of any dedcription over 10 cm in with or girth,not otherwise describe and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 27 | Supply and filling in and speading unwashed river sand for cushioning and covering the under ground cables in trenches and provide required cover coomplete all as specified in SSR Part-I and as directed.Note:Punned thickness i.e. 18cm shall be measured for payment separately. |
| 28 | M & L for sub class \"B\" bricks old size laid dry flat over the cable abutting each other, length of cable equal to width of per brick, complete all as specified and as directed. |
| 29 | Supply and laying XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 50sqmm 3.5 core confirming to IS 7098 (Part-I):1988 laid on trenches/wall/floor or passing through cable duct/trunking and suitable size of lugs, connection with existing LT panels and testing on completion, complete all as specified and directed. |
| 30 | All as per Item No 29.00 here-in-before but size of cable 25sqmm 3.5 core. |
| 31 | All as per Item No 29.00 here-in-before but size of cable 16 sqmm 4.0 core. |
| 32 | All as per Item No 29.00 here-in-before but size of cable 10 sqmm 2.0 core. |
| 33 | M&L for 50mm bore GItubing, light grade, ISI marked with all fittings and fixed to wall and ceiling or laid in floor/ trenches for cable protection, complete all as specified and directed. |
| 34 | M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 including galvanized iron pipe light grade 15 mm for protection to the extend of 7.5mtr as earthing lead connecting to equipment with provn of charcol and salt complete including PCC type C-1 chamber with RCC cover, watering arrangement with GI pipe 20mm dia medium grade and MS funnel, including excavation and earth work and returning, filling including ramming and removal of surplus soild and testing on completion, complete all as specified and directed. |
| 35 | M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level with top edge of the earth plate at a depth not less than 1.5 mtr below normal ground level, connected to and including galvanised iron strip 25 x 4 mm as earthing led by means of bolts, Nuts, Check Nuts and washers of steel after welding of GI tubing 40mm bore, light grade protection pipe upto test point & 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 40 x 40 x 4mm, adequate quantity of charcoal dust and salt layers all around teh earrth plate removal of surplus soild and returning, filling in all as required as site including test point made out of steel plate of size 70 x 75 x 6 mm fixed to wall or pole all as specified in plate No 3 of SSR Part-I, complete all as specified and directed.Note: On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of GE. |
| 36 | S&F in replacement of energy saving & environmental friendly long life LED street light made up of pressure each die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection, impact resistance of IK07 & 10KV external SPD and electronic driver of 45W LED 5700K and making necessary connections with over head line street light feeder with 4 Sqmm PVC insulated aluminium conductor twein core cable 1100 volts upto 5 Mtr length, complete all as specified and directed. |
| 37 | S&F PVC conduit 25mm dia with fixing arrangement on pole including PVC insulated round sheathed copper conductor of 1.5 Sqmm, 3 single core cable duly passing through the holes of existing steel pole/ street light brackets including necessary connection of mounted street light junction box and at the street light fittings, complete all as specified and directed. |
| 38 | S&F in replacement weather proof thermo plastic (Polysterene) cable junction box having protection class IP-66 and of overall size Nos 210mm x 155mm x 92mm having metric knockouts on the wall, duly fixed with the pole with aluminium strip (25 x 3mm) clamp, GI blots, nuts, wahsers and 2 Nos polymide wather proof cable glands of cable sealing range 10mm to 17mm (complete with check nut) and including 1 No 30 Amp 4 way cable connector and 1 No 6 Amp SP MCB, complete all as specified and directed. |
| 39 | S & F in repair of Street light bracket made out of 32 mm dia GI light grade pipe 1.2 mtr long bend to shape 120 degree and duly fixed alongwith existing pole/bldg with the help of2 Nos ofMS clamp ofsizes32x3 mm duly painted with synthetic aluminium paint over a coat of primer including suitable size of bolt ,nuts, andwashers, complete all as specified & as directed. |
| 40 | M&L for preparation of old painted surface of existing steel tubular poles of 9 mtr long including cross arms, cable protection pipe, bus bar box and painting of complete area with one coat of aluminium paint from 1.5mtr above ground level to top of pole and making alternate strips/ layers (30cm wide) with white and blue synthetic enamel paint upto the 1.50 mtr height from the ground level including writing the pole number in white letters on black background and cleaning/ cutting the grass/ bushes at a radius of 2 mtrs surrounding the pole, complete all as specified and directed. |
| 41 | M&L for replacement of LT feeder pillar box factory made pedestal cubical double door outdoor type, CPRI approved, modular construction fabricated out of 3.15mm thick MS sheet, epoxy powder coated to give superior finish, totally enclosed, dust and vermin proof with locking arrangement (compartment wise) front and back side opening system including air louvers at both side, rain shed 15cm all around, overall size of each incoming and out going modules should not be less than (350 x 300 x 400 mm), platform mounted having minimum clearance of 450mm above ground level suitable for 415 volts 3 phase 4 wire system 50 Hz supply, having aluminium basbar strip (three phase & neutral) duly tapped in colour coded FRP sleeves install on procelain/ epoxy insulator, floor mounted type based on angle iron frameand legs 50x50x5mm thick, front and rear opening with double shutter and having locking arrangement and including provision of housing the following accessories:- |
| 42 | Incoming MCCB(a)4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA Nos with thermal magnetic release, Ics=100%, Icu-01 No(b)Digital type Voltmeter (0-500Volts), 3 phase4 digit, hgih resolution, LED type with onsite programmability- 01 No.(c)Digital type Ampermeter (0-300 Amp), three phase with copper wound CT coil accessory of suitable ratio & size Class-I accuracy, 0.5 VA burden & onsite programmability- 01 No(d)Indicating lamp LED type with holder key flush mounted, Red, Yellow, Blue with toggle switch - 01 No (Set of three) as in incoming phases.(e) Bus bar strips made of copper of size 50x 8mm suitable length - 04 Nos. Outgoing MCCB(a)4 Pole MCCB 63 Amp, 50 Hz, 415 V with thermal magnetic release, Ics=100%, Icu- 03 Nos.(b)All outgoing MCCB shall be connected through spreader and copper busbar not less than 5mm thick strip.Notes: All existing cable connections will be disconnected from old panel carefully and re-connected with new panel by providing glands and thimble, complete all as specified and directed. |