| 1 | Dismantling Plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. |
| 2 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed. |
| 3 | Demolition Brickwork or stone/boulder masonry, built in cemnt mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified anddirected . |
| 4 | Dismantling posts or struts (wood, steel or R.C.C.) any section, embedded in natural ground, including taking out embedded portion and making good disturbed groundcomplete all as specified and as directed. |
| 5 | Dismantling fencing wire mesh, any type complete all as specified and as directed. |
| 6 | S&F Prepainted galvalume aluminium zink coating GI based corrugated/semi corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 7 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and as directed. |
| 8 | S&F Rolled mild steel Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.confirming to Fe.410W. Gde-E- 250) quality A) including necessary preperation of surfaces and applying one shop coatof red oxide, zinc chrome primer complete all as specified and as directed. |
| 9 | M&L Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 mmean radius built in cement mortar 1:6complete all as specified and directed. |
| 10 | M&L Brickwork with burnt old size bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed. |
| 11 | Excavating in post holes (or similar holes) in soft/loose soil, each n exc 0.5 cu. m, getting out,and removing soil out of the site ,complete all as specified and as directed. |
| 12 | M&L PCC (1:4:8) type-D2withusing 40 mm graded crushed stoneaggregate as in foundations, filling and mass concrete complete all as specified and as directed. |
| 13 | M&L PCC (1:3:6) type-C2withusing 40 mm graded crushed stoneaggregate as in foundations, filling and mass concrete complete all as specified and as directed. |
| 14 | S&F MS work for posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 including necessary prepration of surface and applying a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 15 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long, Diameter of neck 5-10mm complete all as specified and directed. |
| 16 | Supply only chain link MS galvanized fencing 4mm dia and size as ordered, complete all as specified and as directed. |
| 17 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and as directed |
| 18 | S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed |
| 19 | M&L TMT bar 10 mm diaand over, cut to length, bent to shape required, including cranking, hooking ends as in chain link fencing complete all as specified and as directed. |
| 20 | M&L preparation new iron and steel surfaces of any description, exc 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 21 | M&L preparation new iron and steel surfaces of any description, not exc 10 cm width or girth and applying two coats of synthetic enamel paintover a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 22 | M&L Rendering 15 mm thick on other thanfair faces of brick work or concrete surfaces in cement mortar 1:6 for finished even and smooth complete all as specified and as directed. |
| 23 | M&L 20mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm& 10mm) mixed with and including water proofing compound in top layer as per manufacturer\"s instructions, finishing the surface even and smooth without using extra cement complete all as specified and as directed. |
| 24 | M&L preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm complete all as specified and directed. |
| 25 | M&L applying Two or more coats Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification complete all as specified and directed. |
| 26 | Supply and fix Turbo Ventilators Industrial/domestic turbo ventilator complete all as per manufacturers instructions and as directed. :- (i)(Turbine Dia 28 Inch (760mm), (Nech/Throat-24\"), (Height-18\"/610mm) (Vanes(Blades) - 42 Vanes, Aluminium 0.50mm Alloy 8011), Base Ring MOC(Mounting ring - Stainless steel),(Top plate MOC- Stainless steel 0.80 mm thickness). (ii) Rotation - Twin sealed 6203ZZ bearing with self lubricating duponty zytel 101L Polyamide 66 resin to ensure frictionless rotation even at lowest wind velocity Twin sealed 6201ZZ bearings with self lubricating Duponty Zytel 101L Polyamide 66 resin to ensure frictionless rotation even at lowest wind velocity. (iii) Centre shaft : 18mm high carbon steel zinc plated) ( Inner Arms - M.S. with electro zinc plating), (Outer Arms - M.S. with electro zinc plating), (Frp base plate - 2mm thick clear 1.020 mtr wide 1.65 mtr long matching your sheet profile weight 8Kg Approx), (Centre width - 800mm+/-5mm), (Dia of Bottom Ring- 600mm+/-15mm), (Nos of Bearings -02 Nos), (Bearing Type : SKF-6001ZZ & 6003ZZ) (Rivets-Aluminium Alloy wiht Washer) ,angle adjustable range- 0 to 17 deg,(iv) Exhaust capacity- 1972 - 2164 CFM, Wind velocity 8 Km/Hr |
| 27 | M&L preperation of old concrete/bitumineous surfaces and applying one coat of100% Premium acrylic exterior emulsion paint for Painting lines, dashes, arrows, letters, etc. on roads pavements and the likeexc 10cm width or girth of approved shade completeall as specified and directed. |
| 28 | S&F Racking out of old existing sealant compound, back up rod and filler board of the existing joints (EXPANSION JOINT REPAIR/REPLACMENT IN OLD CONCRETE PAVEMENT) by special tools like racker/cutting blades/machines , widening of joints by 2 mm by using joint cutting blades of appropriate size, straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil, vegetation and other debris Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the filler board and pouring the sealant Thereafter filled with pre-molded 25 mm thick compressible polyethylene closed cell type filler board as specified , over it filled with closed cell medium density, cross linked polyethylene foam backup rod of 30 mm dia for complete length of the joint. Finally filled with polyurethane joint sealant meeting the requirements mentioned in BS-5212, BS 4254 and EN-141875-2003 with minimum movement accommodation factor MAF of+/- 30%.complete all as per manufacturers instruction and as directed. |
| 29 | S&F Racking out of old existing sealant compound and back up rod of the existing joints (DUMMY JOINT REPAIR/ REPLACEMENT IN OLD CONCRETE PAVEMENT)by special tools like cutting blades/machines, widening of joints by 2 mm by using joint cutting blades of appropriate size straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil vegetation and other debris Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before pacing the backup rod and pouring the sealant. Thereafte filled with closed cell, medium density, cross linked polyethylene foam backup rod of 8 mm dia fo complete length of the joint, over it to be filled with polyurethane joint sealant meeting the requirements mentioned in BS-5212, BS 4254 and EN-141875- 2003 with minimum movement accommodation factor (MAF) of+!- 30%. complete all as per manufacturers instruction and as directed. |
| 30 | M&L preperation of old bituminous painted surfaces of road and marking 2mm thick center lines, stop lines, dashes,arrow etc and like on road pavements with hot applied thermo plastic road marking paint of approved colour/shade conforming to BS 3262-1989 with special applicator machine complete all as per manufacturers instruction and as directed. |
| 31 | S&F nylon HDPE bird proofing net 1mm thick 2.5 x 2.5cm size UV Stablized fixed with polypropeline rope of 6mm dia for net and 12mm dia for border with nail clips, cable zip ties and C hoohs as directed.Note : Rate quoted by the contractor shall deemed to inclusive of necessary scaffolding and all other fittings and binding materials as required for fixing the net complete all as directed. |
| 32 | M&Lcomplete removal of old existing paint from concrete surfaces, necessary preperation of surfaces and and applying two coats of aliphatic two components paint (exterior application) complete all as per manufacturers instruction and as directed. |
| 33 | Dismantling of hanger door of size exc 10 Sqm and refixing the same after necessary repair including greasing, replacement of defective wheels as required, chanel top rail/bottom rail , complete all as directed.Note:- Replacement of Wheel, chanel top rail/bottom rail will be measured and paid seperately in respective items) |
| 34 | S&F MS wheel for hanger door with bearings not exc 25cm dia complete all as directed. |
| 35 | M&L Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting platesconfirming to Fe.410W. Gde-E- 250) quality A) including necessary preperation of surfaces and applying one shop coatof red oxide, zinc chrome primer complete all as specified and as directed. |
| 36 | S&F 1.25mm thick Mild steel, plain, black sheet in wall cladding,steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required including necessary preperation of surfaces and applying one shop coatof red oxide, zinc chrome primer complete all as specified and as directed. |
| 37 | Demolition of unreinforced cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and directed. |
| 38 | M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternatebays (not exceeding 2 Sqm each)and finished even and smooth without using extra cement and providing jointsthroughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed. |
| 39 | M&L 100mm thick Plain cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregate as in sub base of path/hardstanding finished even and fair complete all as specified and directed. |
| 40 | M&L PCC (1:3:6) type C-2 (using 40 mm graded agreegate) as in surface chanels and drains, fair finished drain or channel inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed. |
| 41 | M&L PCC (1:2:4) type B-0 (using 12.5 mm graded agreegate), in copings, kneelers, apex stones, bed plates, and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed. |
| 42 | Supply and laying Polythene film, black, 50micron laid in floors complete all as specified and as directed. |
| 43 | M&L Granite (of any type) tiles 18-20mm thick machine cut, floor laid bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing including including 20 mm thick Screed bed or bedding layer of cement mortar 1:6,complete all as specified and directed. |
| 44 | M&L 100mm thick Plain cement concrete type B-2 (1:2:4) using 40 mm graded stone aggregate as in path/hardstanding laid in alternate bays (not exceeding 2 Sqm each) and finished even and fair without using extra cement complete all as specified and directed. |
| 45 | M&L preparation of old wall surface applying one coats of 100% Premium acrylic exterior emulsion paint of required shade as approved complete all as specified and directed. |
| 46 | M&L preparation of old wall surface applying one coats of cement base paint complete all as specified and directed. |