| Sl. No. | Item Description |
| 1 | SUBWORK 1 - UNLOADING PLATFORM |
| 2 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift 0.00 to 1.50 m MJP SSR 2023-24 / P.No. 37 / I.No. 1 |
| 3 | Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 m and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-2/259) Lift 0.00 to 1.50 m MJP SSR 2023-24 / P.No. 37 / I.No. 2 |
| 4 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto distance of 50 m beyond area and lifts as below, stacking as directed. Lift 0.00 to 1.50 m MJP SSR 2023-24 / P.No. 37 / I.No. 5 |
| 5 | Providing dry trap/granite/quartzite/gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264) Soling MJP SSR 2023-24 / P.No. 40 / I.No. 18 |
| 6 | Providing and laying in situ Cement concrete M-15 of trap/granite/quartzite/gneiss metal for foundation and bedding including dewatering, form work, compacting, finishing and curing etc. complete. PCC M-150 MJP SSR 2023-24 Item No.1.b Page No.47 |
| 7 | Providing and laying in situ Cement concrete of trap/granite/quartzite/gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including dewatering, form work, compaction, finishing and curing etc. complete. (Mix Design M-250/M-300) Excluding steel reinforcement. Raft in RCC M-300 MJP SSR 2023-24 / P.No. 47 / I.No.2-d |
| 8 | Providing and fixing in position steel bar reinforcement including cutting, bending, binding, welding and supporting etc. complete. (Including cost of binding wire) Steel MJP SSR 2023-24 / Item No. 8.b / Pg 50 |
| 9 | Structural Design Charges = 2% of cost of RCC work (Item No. 3,4 &5) |
| 10 | SUBWORK 2 - SCREEN CHAMBER |
| 11 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum including removing excavated material up to 50 m, stacking, spreading as directed, dewatering, preparing bed for foundation & excluding backfilling, etc. complete. Lift 0.00 to 1.50 m MJP SSR 2023-24 / P.No. 37 / I.No. 1 |
| 12 | Excavation for foundation / pipe trenches in hard murum including removing excavated material up to 50 m, normal dewatering, stacking as directed & excluding backfilling etc. complete. (Bd-A-2/259) Lift 0.00 to 1.50 m MJP SSR 2023-24 / P.No. 37 / I.No. 2 |
| 13 | Excavation for foundation / pipe trenches in soft rock and old cement/lime masonry foundation including removing excavated material up to 50 m, stacking as directed. Lift 0.00 to 1.50 m MJP SSR 2023-24 / P.No. 37 / I.No. 5 |
| 14 | Providing dry trap/granite/quartzite/gneiss rubble stone soling in 15 cm to 20 cm thick layers including hand packing, compacting etc. complete (Bd-A-12/264). Soling MJP SSR 2023-24 / P.No. 40 / I.No. 18 |
| 15 | Providing and laying in situ cement concrete M-15 for foundation and bedding including dewatering, formwork, compacting, finishing & curing etc. complete. PCC M-150 MJP SSR 2023-24 / Item No. 1.b / Page 47 |
| 16 | Providing and laying in situ cement concrete for RCC work in foundation like raft, grillage, strip foundation & footing including dewatering, formwork, compacting & curing etc. complete. (Mix design M-250/M-300). Raft in RCC M-300 — Excluding Reinforcement MJP SSR 2023-24 / P.No. 47 / I.No.2-d |
| 17 | Providing & casting in situ RCC M-30 for vertical wall including centering, formwork, finishing with C.M. 1:3, compaction, dewatering & curing etc. complete — Excluding steel reinforcement. RCC M-30 Vertical Wall MJP SSR 2023-24 / P.No. 48 / I.No.5-d |
| 18 | Filling in plinth and floors/trenches with contractor’s murum in 15–20 cm layers including watering & compaction etc. complete (Bd-A-11/263). Filling MJP SSR 2023-24 / P.No. 41 / I.No.17 |
| 19 | Providing & fixing steel bar reinforcement including cutting, bending, binding, welding & supporting etc. complete including binding wire. Steel MJP SSR 2023-24 / Item No. 8.b / Pg. 50 |
| 20 | Providing & applying water proofing treatment using acrylic polymer modified cement-based waterproof coating with fiberglass mesh — 7 years guarantee. Water Proofing PWD SSR 2022-23 / P.No.206 / I.No.31.09 |
| 21 | Structural Design Charges = 2% of Cost of RCC Work (Item No. 3, 4, 5 & 7) |
| 22 | SUBWORK 3 - SLUDGE STORAGE TANK |
| 23 | Excavation for foundation / pipe trenches in earth, soils of all types including removal of excavated material up to 50 m, stacking & spreading, dewatering, bed preparation & excluding backfilling, etc. complete. Lift 0.00 to 1.50 m MJP SSR 2023-24 / P.No. 37 / I.No.1 |
| 24 | Excavation for foundation / pipe trenches in hard murum including removing excavated material up to 50 m, stacking & spreading, normal dewatering & excluding backfilling etc. complete. (Bd-A-2/259) Lift 0.00 to 1.50 m MJP SSR 2023-24 / P.No. 37 / I.No.2 |
| 25 | Excavation for foundation / pipe trenches in soft rock including removing excavated material up to 50 m & stacking as directed. Lift 0.00 to 1.50 m |
| 26 | Lift 1.50 to 3.00 m MJP SSR 2023-24 / P.No.37 / I.No.5 |
| 27 | Excavation for trenches in hard rock & concrete road by chiseling or mechanical means including removing material up to 50 m & excluding backfilling. (Bd-A-6/259) Lift 1.50 to 3.00 m MJP SSR 2023-24 / P.No. 37 / I.No.5 |
| 28 | Providing dry rubble soling in 15–20 cm layers including hand packing & compacting etc. complete (Bd-A-12/264). Soiling MJP SSR 2023-24 / P.No. 40 / I.No.18 |
| 29 | Providing & laying PCC M-15 for foundation bedding including formwork, roughening, finishing & curing etc. complete. PCC M-150 MJP SSR 2023-24 / Item No.1.b / Pg.47 |
| 30 | Providing & laying RCC M-300 in raft foundation including formwork, compaction & curing etc. complete — excluding steel reinforcement. Raft in RCC M-300 MJP SSR 2023-24 / P.No. 47 / I.No.2-d |
| 31 | Providing & casting RCC M-30 vertical wall including formwork, centering, compaction, finishing, curing etc. complete — excluding steel. RCC M-30 Vertical Wall MJP SSR 2023-24 / P.No. 48 / I.No.5-d |
| 32 | Providing & casting RCC M-30 slab including formwork, compaction, finishing & curing etc. — excluding steel. RCC M-30 Slab MJP SSR 2023-24 / P.No. 48 / I.No.5-d |
| 33 | Providing & fixing steel reinforcement including cutting, bending, binding, welding & all supports — including binding wire. Steel MJP SSR 2023-24 / Item No. 8.b / Pg.50 |
| 34 | Filling in plinth/floors/trenches with contractor’s murum in 15–20 cm layers including watering & compaction etc. complete. (Bd-A-11/263) Filling MJP SSR 2023-24 / P.No. 41 / I.No.17 |
| 35 | Providing & fixing SFRC frame & fibre reinforced covers (20T capacity) including all taxes & transport. 90 × 60 cm size SFRC Cover MJP SSR 2023-24 / P.No. 287 / I.No.17-d |
| 36 | Providing & applying waterproofing treatment using acrylic polymer cement-based coating with glass mesh — 7-year guarantee. Water Proofing PWD SSR 2022-23 / P.No.206 / I.No.31.09 |
| 37 | Structural Design Charges = 2% of cost of RCC work (Item No. 3,4,5 & 7) |
| 38 | SUBWORK 4 - MULTI DISK SREW BASED PLATFORM |
| 39 | Excavation for foundation/pipe trenches in earth, soils of all types including removing excavated material up to 50 m, stacking & spreading, dewatering, preparing bed & excluding backfilling etc. complete. Lift 0.00 to 1.50 m MJP SSR 2023-24 / P.No.37 / I.No.1 |
| 40 | Excavation for foundation/pipe trenches in hard murum including removing excavated material up to 50 m, normal dewatering and excluding backfilling etc. complete. (Bd-A-2/259) Lift 0.00 to 1.50 m MJP SSR 2023-24 / P.No.37 / I.No.2 |
| 41 | Excavation for foundation/pipe trenches in soft rock including removing excavated material up to 50 m & stacking as directed. Lift 0.00 to 1.50 m |
| 42 | Providing dry trap/granite/quartzite/gneiss rubble stone soling in 15–20 cm layers including hand packing & compacting etc. complete. (Bd-A-12/264) Soiling MJP SSR 2023-24 / P.No.40 / I.No.18 |
| 43 | Providing & laying PCC M-15 for foundation/bedding including dewatering, formwork, compacting, finishing & curing etc. complete. PCC M-150 MJP SSR 2023-24 / Item No.1.b / Pg.47 |
| 44 | Providing & laying RCC M-300 in raft foundation including formwork, compaction & curing etc. complete — excluding steel. Raft in RCC M-300 MJP SSR 2023-24 / P.No.47 / I.No.2-d |
| 45 | Providing & casting RCC M-30 Column including centering, formwork, finishing, curing etc. complete — excluding steel. RCC M-30 Column MJP SSR 2023-24 / P.No.48 / I.No.5-d |
| 46 | Providing & casting RCC M-30 Beam including centering, formwork, compaction & curing — excluding steel RCC M-30 Beam MJP SSR 2023-24 / P.No.48 / I.No.5-d |
| 47 | Providing & casting RCC M-30 Slab including centering, formwork, compaction & curing — excluding steel RCC M-30 Slab MJP SSR 2023-24 / P.No.48 / I.No.5-d |
| 48 | Providing & fixing steel reinforcement including cutting, bending, binding, welding & supporting etc. complete — including binding wire. Steel MJP SSR 2023-24 / Item No.8.b / Pg.50 |
| 49 | Providing structural steel work in single stanchions of RSJ/channel including fabrication, hoisting, fixing & painting etc. complete. Structural Steel MJP SSR 2023-24 / Item No.4 / Pg.45 |
| 50 | Providing & fixing corrugated GI sheet roofing of 0.63 mm thickness including fastening accessories etc. complete. GI Sheet PWD SSR 2022-23 / Item No.38.08 / Pg.233 |
| 51 | Filling in plinth & floors/trenches with murum including watering & compaction etc. complete (Bd-A-11/263). Filling MJP SSR 2023-24 / P.No.41 / I.No.17 |
| 52 | Structural Design Charges = 2% of Cost of RCC Work (Item No. 3,4,5 & 7) |
| 53 | SUBWORK 5 - LIQUID STORAGE TANK |
| 54 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift 0.00 to 1.50 m MJP SSR 2023-24 / P.No. 37 / I.No. 1 |
| 55 | Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-2/259) Lift 0.00 to 1.50 m MJP SSR 2023-24 / P.No. 37 / I.No. 2 |
| 56 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge. Lift 0.00 to 1.50 m MJP SSR 2023-24 / P.No. 37 / I.No. 5 |
| 57 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge. Lift 1.50 to 3.00 m MJP SSR 2023-24 / P.No. 37 / I.No. 5 |
| 58 | Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by all means. (Bd-A-6/259) Lift 1.50 to 3.00 m MJP SSR 2023-24 / P.No. 37 / I.No. 5 |
| 59 | Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264) Soiling MJP SSR 2023-24 / P.No. 40 / I.No. 18 |
| 60 | Providing and laying in situ Cement concrete M-15 of trap or granite or quartzite or gneiss metal for foundation and bedding including dewatering, form work, compacting, roughening them if special finish is to be provided, finishing if required and curing etcetera complete. PCC M-150 MJP SSR 2023-24 / Item No. 1.b / Page No. 47 |
| 61 | Providing and laying in situ Cement concrete of trap/granite/quartzite/ gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc, complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) Excluding M. S. or Tor Reinforcement. Raft in RCC M-300 MJP SSR 2023-24 / P.No. 47 / I.No. 2-d |
| 62 | Providing and casting in situ c.c. of trap/ granite/ quartzite/ gnesis metal of approved quality for RCC works as per detailed drawings and designs or as directed including normal dewatering, centering, form work, bally, steel propups, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special is to be provided and curing etc. complete (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C. Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) Excluding M.S. reinforcements. RCC M-30 Vertical Wall MJP SSR 2023-24 / P.No. 48 / I.No. 5-d |
| 63 | Providing and casting in situ c.c. of trap/ granite/ quartzite/ gnesis metal of approved quality for RCC works as per detailed drawings and designs or as directed including normal dewatering, centering, form work, bally, steel propups, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special is to be provided and curing etc. complete (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C. Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) Excluding M.S. reinforcements. RCC M-30 Slab MJP SSR 2023-24 / P.No. 48 / I.No. 5-d |
| 64 | Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). Steel MJP SSR 2023-24 / Item No. 8.b / Pg. No. 50 |
| 65 | Filling in plinth and floors / trenches with contractor\"s murum for bedding in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-11/263) Filling MJP SSR 2023-24 / P.No. 41 / I.No. 17 |
| 66 | Providing and fixing in position steel concrete (S.F.R.C.) frame and fibre covers reinforced of approved make including loading, unloading, transportation, all taxes, etc. complete as directed by Engineer-in-charge (20 tonnes capacity). 90 x 60 cm size SFRC Cover MJP SSR 2023-24 / P.No. 287 / I.No. 17-d |
| 67 | Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Sq.m / Kg with two coats using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. Water Proofing PWD SSR 2022-23 / P.No. 206 / I.No. 31.09 |
| 68 | Structural Design Charges = 2 % of Cost of RCC work (Item No. 3, 4, 5 & 7) |
| 69 | SUBWORK 6 - ZINC ALUMINIUM TANK |
| 70 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum including removing excavated material up to 50m and lifts as below, stacking and spreading as directed, manual dewatering, preparing bed for foundation and excluding backfilling etc. complete. Lift 0.00 to 1.50 m MJP SSR 2023-24 / P.No. 37 / I.No. 1 |
| 71 | Excavation for foundation / pipe trenches in hard murum including removing excavated material up to 50m, stacking and spreading as directed, normal dewatering, preparing bed for foundation and excluding backfilling etc. complete. (Bd-A-2/259) Lift 0.00 to 1.50 m MJP SSR 2023-24 / P.No. 37 / I.No. 2 |
| 72 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry including removing excavated material up to 50m beyond area & lifts as below, stacking as directed. Lift 0.00 to 1.50 m |
| 73 | Providing dry trap / granite / quartzite / gneiss rubble stone soling in 15–20 cm layer including hand packing and compacting etc. complete. (Bd-A-12/264) Soiling MJP SSR 2023-24 / P.No. 40 / I.No. 18 |
| 74 | Providing and laying PCC M-15 for foundation / bedding including dewatering, formwork, compacting, finishing & curing etc. complete. PCC M-150 MJP SSR 2023-24 / Item No. 1.b / Pg. 47 |
| 75 | Providing and laying RCC M-300 in raft foundation including form work, compaction, curing etc. (Mix Design M-250/M-300) Excluding steel reinforcement Raft in RCC M-300 MJP SSR 2023-24 / P.No. 47 / I.No.2-d |
| 76 | Providing and fixing steel reinforcement for all RCC works including cutting, bending, binding, welding, supporting etc. complete including binding wire Steel MJP SSR 2023-24 / Item No. 8.b / Pg. 50 |
| 77 | Providing and doing structural steel work including fabrication, hoisting, fixing in position & painting complete. Structural Steel MJP SSR 2023-24 / Item No.4 / Pg. 45 |
| 78 | Providing and fixing corrugated G.I. sheet roofing 0.63 mm thick including fastening with screws & bolts complete. GI Sheet PWD SSR 2022-23 / Item No.38.08 / Pg. 233 |
| 79 | Filling in plinth / floors / trenches with contractor’s murum including watering & compaction etc. complete. (Bd-A-11/263) Filling MJP SSR 2023-24 / P.No. 41 / I.No. 17 |
| 80 | Supply & installation of prefabricated ground water storage bolted tank 6750 Ltr capacity including accessories, complete for drinking water. 6750 Ltr Zinc Tank MJP SSR 2023-24 / P.No. 41 / I.No. 17 |
| 81 | Structural Design Charges = 2% of Cost of RCC work (Item No. 3, 4, 5 & 7) |
| 82 | SUBWORK 7 - FILTER FEED TANK |
| 83 | Excavation for foundation/pipe trenches in earth, soils of all types including dewatering, stacking & excluding backfilling etc. complete. Lift 0.00 to 1.50m MJP SSR 2023-24 / P.No.37 / I.No.1 |
| 84 | Excavation in hard murum including removing excavated material upto 50m & excluding backfilling etc. complete. (Bd-A-2/259) Lift 0.00 to 1.50m MJP SSR 2023-24 / P.No.37 / I.No.2 |
| 85 | Excavation in soft rock including removing excavated material upto 50m & stacking as directed. Lift 0.00 to 1.50m |
| 86 | Lift 1.50 to 3.00m MJP SSR 2023-24 / P.No.37 / I.No.5 |
| 87 | Lift 1.50 to 3.00m MJP SSR 2023-24 / P.No.37 / I.No.5 |
| 88 | Dry rubble stone soling including hand packing & compacting etc. complete. (Bd-A-12/264) Soiling MJP SSR 2023-24 / P.No.40 / I.No.18 |
| 89 | Providing & laying PCC M-150 including dewatering, formwork, compaction & curing etc. complete. MJP SSR 2023-24 / Item No.1.b / Pg.47 |
| 90 | Providing & laying RCC M-300 in raft including formwork, compaction & curing etc. Excluding steel MJP SSR 2023-24 / P.No.47 / I.No.2-d |
| 91 | Providing & casting RCC M-30 Vertical Wall including formwork & curing etc. Excluding steel MJP SSR 2023-24 / P.No.48 / I.No.5-d |
| 92 | Providing & casting RCC M-30 Slab including formwork & curing etc. Excluding steel MJP SSR 2023-24 / P.No.48 / I.No.5-d |
| 93 | Providing & fixing steel reinforcement incl. cutting, bending, binding etc. complete incl. binding wire. Steel MJP SSR 2023-24 / Item No.8.b / Pg.50 |
| 94 | Filling in plinth/floors/trenches with contractor’s murum incl. watering & compaction etc. complete. (Bd-A-11/263) Filling MJP SSR 2023-24 / P.No.41 / I.No.17 |
| 95 | Providing & fixing SFRC Cover 90×60cm (20T capacity) incl. transport, loading, taxes etc. 6750 Ltr Zinc Tank MJP SSR 2023-24 / P.No.287 / I.No.17-d |
| 96 | Applying acrylic polymer waterproofing coating with glass mesh — 7 years guarantee Water Proofing PWD SSR 2022-23 / P.No.206 / I.No.31.09 |
| 97 | Structural Design Charges = 2% of RCC work (Item 3,4,5 & 7) |
| 98 | SUBWORK 9 - TREATED WATER TANK |
| 99 | Excavation for foundation/pipe trenches in earth, soils of all types including dewatering, stacking & excluding backfilling etc. complete.Lift 0.00 to 1.50mMJP SSR 2023-24 / P.No.37 / I.No.1 |
| 100 | Excavation in hard murum including removing excavated material upto 50m & excluding backfilling etc. complete. (Bd-A-2/259)Lift 0.00 to 1.50mMJP SSR 2023-24 / P.No.37 / I.No.2 |
| 101 | Excavation in soft rock including removing excavated material upto 50m & stacking as directed.Lift 0.00 to 1.50m |
| 102 | Lift 1.50 to 3.00m |
| 103 | Excavation in hard rock & concrete road by chiselling/line drilling including disposal beyond 50m excluding backfilling etc. complete. (Bd-A-6/259)Lift 1.50 to 3.00mMJP SSR 2023-24 / P.No.37 / I.No.5 |
| 104 | Providing dry trap/ granite/ quartzite/ gneiss rubble stone soling including packing & compacting. (Bd-A-12/264)SoilingMJP SSR 2023-24 / P.No.40 / I.No.18 |
| 105 | Providing & laying PCC M-15 for foundation & bedding including curing etc. complete.MJP SSR 2023-24 / Item No.1.b / Pg-47 |
| 106 | RCC work (Raft) M-300 including formwork, dewatering, curing etc. complete (Excluding steel).MJP SSR 2023-24 / P.No.47 / I.No.2-d |
| 107 | RCC work M-30 Vertical Wall incl. centering, steel props & finishing. (Excluding steel)MJP SSR 2023-24 / P.No.48 / I.No.5-d |
| 108 | RCC work M-30 Slab incl. centering, steel props & finishing. (Excluding steel)MJP SSR 2023-24 / P.No.48 / I.No.5-d |
| 109 | Providing & fixing steel reinforcement including cutting, bending & binding (incl. binding wire).MJP SSR 2023-24 / Item No.8.b / Pg-50 |
| 110 | Filling in plinth/trenches with contractor’s murum including watering & compaction. (Bd-A-11/263)MJP SSR 2023-24 / P.No.41 / I.No.17 |
| 111 | Providing & fixing SFRC cover 90×60 cm including all taxes, loading/unloading (20T capacity)MJP SSR 2023-24 / P.No.287 / I.No.17-d |
| 112 | Providing & applying waterproofing coating with fiberglass mesh (7-years guarantee)PWD SSR 2022-23 / P.No.206 / I.No.31.09 |
| 113 | Structural Design Charges = 2% of RCC Work (Item No.3,4,5&7) |
| 114 | SUBWORK 10 - SLUDGE DRYING BED |
| 115 | Excavation for foundation/pipe trenches in earth, soils of all types including dewatering, stacking & excluding backfilling etc. complete.Lift 0.00 to 1.50mMJP SSR 2023-24 / P.No.37 / I.No.1 |
| 116 | Excavation in hard murum including removing excavated material upto 50m & excluding backfilling etc. complete. (Bd-A-2/259)Lift 0.00 to 1.50mMJP SSR 2023-24 / P.No.37 / I.No.2 |
| 117 | Excavation in soft rock including removing excavated material upto 50m & stacking as directed.Lift 0.00 to 1.50m |
| 118 | Providing trap/granite/quartzite/gneiss rubble stone soling including packing & compacting etc. complete. (Bd-A-12/264)SoilingMJP SSR 2023-24 / P.No.40 / I.No.18 |
| 119 | Providing & laying PCC M-15 for foundation & bedding incl. formwork etc. complete.MJP SSR 2023-24 / Item No.1.b / Pg-47 |
| 120 | RCC work (Raft) M-300 incl. formwork, curing etc. complete (excluding steel).MJP SSR 2023-24 / P.No.47 / I.No.2-d |
| 121 | Providing & fixing steel reinforcement incl cutting, bending & binding wire.MJP SSR 2023-24 / Item No.8.b / Pg-50 |
| 122 | Providing second-class Burnt Brick masonry in CM 1:4 incl. scaffolding etc.Brick workMJP SSR 2023-24 / Item No.8.b / Pg-50 |
| 123 | Providing internal cement plaster 12mm thick in CM 1:4 incl. curing & scaffolding.Internal PlasteringPWD SSR 2022-23 / I.No.32.04 / Pg-209 |
| 124 | Providing external sand-faced plaster 15mm + finish 6–8mm CM 1:4 incl. WPC & curing.External PlasteringPWD SSR 2022-23 / I.No.32.11 / Pg-209 |
| 125 | Providing & applying white-wash in 2 coats incl. surface preparation.PWD SSR 2022-23 / I.No.36.03 / Pg-227 |
| 126 | Providing & applying colour-wash in 1 coat incl. brushing and cleaning.PWD SSR 2022-23 / I.No.36.04 / Pg-227 |
| 127 | Providing structural steel sections incl. welding, bolting & painting.Structural SteelMJP SSR 2023-24 / Item No.4 / Pg-45 |
| 128 | Providing & fixing Corrugated GI Sheet 0.63mm for roofing incl. screws & bolts.PWD SSR 2022-23 / Item No.38.08 / Pg-233 |
| 129 | Filling in plinth/floor trenches with contractor’s murum incl. watering & compaction.MJP SSR 2023-24 / P.No.41 / I.No.17 |
| 130 | Structural Design Charges = 2% of RCC work (Item No. 3,4,5 & 6) |
| 131 | SUBWORK 11 - Control Panel cum Office Room with Toilet Block and Internal Electrical work |
| 132 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling etc. complete. Lift 0 to 1.5 m. (MJP SSR 2023-24 Item No. 1, Pg. 37) |
| 133 | Filling in plinth and floors / trenches with contractor\"s murum in 15 cm to 20 cm layers including watering and compaction etc. complete (Bd-A-11/263). Lift 0 to 1.5 m. (MJP SSR 2023-24 P.No.41 I.No.17) |
| 134 | Providing and laying in situ Cement Concrete M-15 (trap/granite/quartzite/gneiss metal) for foundation and bedding including dewatering, formwork, compaction, finishing & curing complete. (MJP SSR 2023-24 Item 1.b Pg.47) |
| 135 | Providing pre-constructional anti-termite treatment as per IS-6313 Part-II by treating the bottom and sides of excavation using 1% chlorpyriphos solution – including 10 yrs guarantee on bond paper. (PWD SSR 2023-24 Item 21.22 Pg.155) |
| 136 | Providing & laying in situ RCC M-200 for footing including formwork, compaction, finishing & curing complete excluding steel reinforcement – using approved cement. (MJP SSR 2023-24 Item 2.b Pg.47) |
| 137 | Providing & casting in situ RCC M-200 for beams & lintels including centering, formwork, compaction, finishing & curing complete excluding steel reinforcement. (MJP SSR 2023-24 Item No.4 Pg.50) |
| 138 | Providing & casting RCC M-200 for columns including centering, formwork, compaction, finishing & curing complete excluding reinforcement. (MJP SSR 2023-24 Item 3.b Pg.47) |
| 139 | Providing & casting RCC M-200 for slab including centering, formwork, compaction, finishing & curing complete excluding reinforcement. (MJP SSR 2023-24 Item 5.b Pg.48) |
| 140 | Providing & casting RCC M-200 for chhajja including centering, formwork, compaction, finishing & curing complete excluding reinforcement. (MJP SSR 2023-24 Item 6.b Pg.49) |
| 141 | Steel bar reinforcement including cutting, bending, hooking & binding wire complete. (MJP SSR 2023-24 Item 8.b Pg.50) |
| 142 | Second class Burnt Brick masonry in cement mortar 1:6 in foundation and plinth including joint raking and curing complete. (PWD SSR 2022-23 Item 27.15 Pg.197) |
| 143 | Second class Burnt Brick masonry in superstructure in CM 1:6 including raking out joints, scaffolding and curing etc. complete. (PWD SSR 2022-23 Item 27.05 Pg.197) |
| 144 | Internal cement plaster 12mm thick in single coat in CM 1:3 including scaffolding & curing complete. (PWD SSR 2022-23 Item 32.05 Pg.209) |
| 145 | Sand faced plaster externally in CM 1:4 including 15mm base coat with waterproofing & finishing by taking out grains complete. (PWD SSR 2022-23 Item 32.11 Pg.209) |
| 146 | White wash in two coats on old/new plastered or masonry surfaces including cleaning and scaffolding complete. (PWD SSR 2022-23 Item 36.03 Pg.227) |
| 147 | Colour wash one coat on new surface including scaffolding and cleaning. (PWD SSR 2022-23 Item 36.04 Pg.227) |
| 148 | Matt finish ceramic floor tiles 30cm×30cm laid on CM 1:4 including joint filling and curing complete. (PWD SSR 2022-23 Item 33.24 Pg.215) |
| 149 | Bamboo wood paneling in shutters 10mm thick complete with fixing accessories as per drawings. (PWD SSR 2022-23 Item 48.20 Pg.313) |
| 150 | Steel window with guard bars complete including glazing & oil painting. (PWD SSR 2022-23 Item 39.20 Pg.247) |
| 151 | 30mm Thick Both Side Pre-laminated PVC Door Shutter with MS frame and fixing hardware complete. (PWD SSR 2022-23 Item 39.47 Pg.255) |
| 152 | Ceramic wall tiles in dado/skirting 30×30cm with adhesive mortar and joint filling complete. (PWD SSR 2022-23 Item 33.25 Pg.215) |
| 153 | HDP Water tank 200–1000L including delivery, hoisting & fixing complete. (PWD SSR 2022-23 Item 42.53 Pg.280) |
| 154 | Orissa type white glazed WC with trap & necessary fittings complete. (PWD SSR 2022-23 Item 48.42 Pg.316) |
| 155 | White glazed Wash Hand Basin with brass fittings & connections complete. (PWD SSR 2022-23 Item 41.65 Pg.272) |
| 156 | Decorative pre-wired batten fitting for 4ft LED tube (without tube). (PWD Elec. SSR 2023-24 Item 2-1-1 Pg.15) |
| 157 | Ceiling fan of 1400mm sweep installed complete. (PWD Elec. SSR 2023-24 Item 2-9-3 Pg.25) |
| 158 | Modular switch 6A/10A with plate & wiring connection. (PWD Elec. SSR 2023-24 Item 2-6-1 Pg.23) |
| 159 | Earthing with GI plate 60×60×0.6cm complete including testing. (PWD Elec. SSR 2023-24 Item 9-1-3 Pg.140) |
| 160 | Structural Design Charges = 2% of RCC cost (Items 5–9, 11 & 12) |
| 161 | SUBWORK 12 - FILTER MEDIA |
| 162 | For ZA Tank |
| 163 | Stone Aggregate 10mm |
| 164 | Stone Aggregate 20mm |
| 165 | Stone Aggregate 40mm |
| 166 | For SDB |
| 167 | Stone Aggregate 10mm |
| 168 | Stone Aggregate 20mm |
| 169 | SUBWORK 13 - ALLIED WORK |
| 170 | Providing and fixing board displaying information, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangular shape of 1.20m x 0.90m size made out of 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border/messages/symbols etc. with approved colour shade paint complete, on M.S. angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mm x 35mm x 3mm duly painted including two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc. and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including excavation, refilling, transportation, and labour etc. complete. Spec. as directed by Engineer in ChargePWD/SSR 2022-23 / Item No. 6.36 / Page No. 60 |
| 171 | Material Testing such as Cement, Sand, Aggregate, steel, brick, paving block etc.As per Rate Analysis |
| 172 | Topographic Survey of land available at site for construction of FSTPAs per Quotation |
| 173 | Carryout Ficals Sample testAs per Quotation |
| 174 | Providing and erecting Y-type barbed wire fencing with seven rows of wire with 2.45 mm dia G.I. pipe (Rezan/concenti deleted 0.75 mm dia), hot dip coated hooks as per drawing, supported on M.S. angle 50 x 50 x 6 mm at 2.5m c/c including fixing and fastening with wire, painting M.S. angles with one coat of red lead primer and two coats of oil paint etc. complete.PWD SSR 2022-23 / P.No. 264 / I.No. 40.05 |
| 175 | Providing and fixing M.S. gate 2.5 m wide for compound with 40 mm dia G.I. pipe, approved grill work, RCC M-150 side pillars of 25cm x 40cm x 2.5m height, foundation, finishing, painting etc. complete.MJP SSR 2023-24 / I.No. 3 / P.No. 56 |
| 176 | Technology Provider Charges — process calculations with hydraulic design and drawings as per land availability and FSTP capacity.As per Market Rate |
| 177 | SUBWORK 14 - E & M WORK |
| 178 | Manual Screen — size 1 m length x 0.5 m width of SS 304 MOC and manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 Nos. 10 mm SS rod of total length 200 mm straight and 50 mm of 90° bend complete.As per Quotation |
| 179 | Sewage Pump – Supplying Non clog Submersible Pump suitable for sewage/Liquid waste application up to 10 m head |
| 180 | MDSP Pump (1W + 1S) |
| 181 | ZA Tank Feed Pump (1W + 1S) |
| 182 | Filter Feed Pump (1W + 0S) |
| 183 | Treated Water Pump (1W + 0S) |
| 184 | Multi Disc Screw Press 0.625 Cu.m/Hr inlet flow including automatic polymer dosing system.As per Quotation |
| 185 | Transportation & Erection Charges = 10% of Screw Press Machinery |
| 186 | Designing, Supplying, Installing, Commissioning & Testing of Power Analyzer with Modbus communication as per IEC 62053 including mounting arrangement.MJP Mech.CSR 2023-24 / I.No. 2.5 / P.No. 127 |
| 187 | Supplying & erecting DOL starter for 380-440 V, 3 Phase motor with no-volt coil, overload elements etc., complete. For motors >7.5 HP & upto 12.5 HP.MJP Mech.CSR 2023-24 / I.No. LG 3-1 / P.No. 39 |
| 188 | Supply, Install & Commission Electromagnetic Flow Meter (EMF) — 63 mm sizeAs per Quotation |
| 189 | 3 Core PVC insulated and sheathed copper conductor flat submersible cableMJP Mech.CSR 2023-24 / I.No. CB 1-6 / P.No. 48 |
| 190 | Aluminium 4-Core XLPE/PVC insulated & armoured cable — 1100V grade, including GI earth wire and fixing with clamps in wall/trench.MJP Mech.CSR 2023-24 / I.No. CB 6-2 / P.No. 51 |
| 191 | Copper conductor PVC insulated un-armoured control cable — 1.1kV grade installed on wall/panel in approved mannerMJP Mech.CSR 2023-24 / I.No. CB 8-2 / P.No. 53 |
| 192 | Pressure Sand Filter & Activated Carbon Filter of FRP / MSEP with MPV / 5-Valve system and piping etc. completeAs per Quotation |
| 193 | NaOCl Chlorination Pump — Diaphragm / Peristaltic / Solenoid type, 10 LPH with mixing tank, complete.As per Quotation |
| 194 | Providing & supplying ISI mark UPVC pipes including couplers & solvent cement joints — Working pressure 8 Kg/cm² |
| 195 | UPVC Pipe 63 mm dia |
| 196 | UPVC Pipe 75 mm dia |
| 197 | UPVC Pipe 90 mm dia |
| 198 | Providing double flange sluice valve confirming to IS-14846 including gear arrangement, SS spindle, inspection & loading/unloading etc.MJP SSR 2023-24 / I.No.2-a-iii / P.No. 145• 80 mm Dia |
| 199 | Providing & supplying ISI marked CI Double Flanged Reflux Valve including all taxes & transportMJP SSR 2023-24 / I.No 12-a-iii / P.No. 144• 80 mm Dia |
| 200 | Lowering, laying, jointing CI/DF valves including all labour, materials, testing etc.MJP SSR 2023-24 / Page 148 / Item No. 4• 80 mm Dia |
| 201 | Hydraulic testing of CI/DF valves including documentationMJP SSR 2023-24 / Page 148 / Item No. 4b• 80 mm Dia |
| 202 | Bio Media — Specially designed Filter Media including HDPE bags + coco husk + vermicompost media with worms as per designAs per Quotation |
| 203 | SUBWORK 14 - E & M WORK |
| 204 | Operation & Maintenance Charge for 1 Year Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail