| 1 | Maintenance of Earth Pits located inside Township. The contractor shall replace the rusted nuts & bolts of the earth electrode, cleaning of EP surrounding area upto two feet distance, measuring of earth pit resistance using the earth megger, watering of earth pits and numbering on covers of earth pits using stencils and enamel paints as directed by the Engineer-in-charge. |
| 2 | Operation of Indoor Sub-station installed at Amaipakkam Township, on Two Shift basis including logging of various readings, attending to emergency breakdowns, minor maintenance works, maintenance of Power and Lighting Installation, maintenance of Energy Meter Distribution Board located in buildings inside Township and attending to fuse of calls as directed by Engineer-in-charge. The Sub-station includes HT and LT switchboards, Transformers, DG Set, feeder pillars, .. The contractor shall ensure presence of at least one electrician possessing valid \"B\" licence Holder/ITI/DEEE/ Experienced and one Manmazdoor in each shift. (1 Set = 1 Electrician + 1 Helper). Contractor has to pay minimum wages to the labour as per the latest CPWD wage sheet for Highly skilled worker & Semi skilled worker for Electrician and Manmazdoor respectively. Monthly labour payment receipt voucher has to be submitted by the contractor. |
| 3 | Earth work excavation in all types of soil to provide cable trenches for laying ofPower/ Telephonecables includingbackfillingof trenches to the original level and ramming and watering of earth forconsolidationof thesoil and disposing of the surplus earth within a lead of 15Mtrs. as directed by the Engineer-in-Charge. |
| 4 | Laying and installation ofLT armoured cables(required cable alone will be supplied free of cost by the Dept) in excavated trenches as detailed in scope of work for 1No.3/4CX10/16sqmm or 1No.10/20 pair telephone cable or Earth Conductor upto 95sqmm. |
| 5 | Laying and installation ofLT armoured cables(required cable alone will be supplied free of cost by the Dept) in excavated trenches as detailed in scope of work for 1No.3.5/4CX35/50/70 sqmm or 1No.50/100 pair telephone cable. |
| 6 | Laying and installation ofLT armoured cables(required cable alone will be supplied free of cost by the Dept) in excavated trenches as detailed in scope of work for 1No. 3.5CX120/185 sqmm armoured cable. |
| 7 | Laying and installation ofLT armoured cables(required cable alone will be supplied free of cost by the Dept) in excavated trenches as detailed in scope of work for 1No.3.5CX400 sqmm armoured cable. |
| 8 | Laying and installation ofLT armoured cables(required cable alone will be supplied free of cost by the Dept) in built-in-trenches on cable supports, on walls\ RCC masonry surface as detailed in scope of work. 1No.3/4CX10/16sqmm or 1No.10/20 pair telephone cable or Earth Conductor upto 95sqmm. |
| 9 | Laying and installation ofLT armoured cables(required cable alone will be supplied free of cost by the Dept) in built-in-trenches on cable supports, on walls\ RCC masonry surface as detailed in scope of work for 1No.3.5/4CX35/50/70 sqmm or 1No.50/100 pair telephone cable. |
| 10 | Laying and installation ofLT armoured cables(required cable alone will be supplied free of cost by the Dept) in built-in-trenches on cable supports, on walls\ RCC masonry surface as detailed in scope of work for 1No.3.5CX120/185 sqmm armoured cable. |
| 11 | Laying and installation ofLT armoured cables(required cable alone will be supplied free of cost by the Dept) in built-in-trenches on cable supports, on walls\ RCC masonry surface as detailed in scope of work for 1No.3.5CX400 sqmm armoured cable. |
| 12 | Cleaning of cable trench of following dimensions inside various buildings from dust, cobwebs, removal of debris if any etc. as directed by the Engineer-in-Charge. Upto and including 600 x 600 mm size |
| 13 | Retrieval and relaying of following size of armoured cables for rerouting/new cable laying in excavated trenches using the retrieved bricks in brick work/slab upto 950mm depth including the supply of river sand for 1No.3/4CX10/16sqmm or 1No.10/20 pair telephone cable or Earth Conductor upto 95sqmm. |
| 14 | Retrieval and relaying of following size of armoured cables for rerouting/new cable laying in excavated trenches using the retrieved bricks in brick work/slab upto 950mm depth including the supply of river sand for 1No.3.5/4CX35/50/70 sqmm or 1No.50/100 pair telephone cable. |
| 15 | Retrieval and relaying of following size of armoured cables for rerouting/new cable laying in excavated trenches using the retrieved bricks in brick work/slab upto 950mm depth including the supply of river sand for 1No.3.5CX120/185 sqmm armoured cable. |
| 16 | Retrieval and relaying of following size of armoured cables for rerouting/new cable laying in excavated trenches using the retrieved bricks in brick work/slab upto 950mm depth including the supply of river sand for 1No.3.5CX400 sqmm armoured cable. |
| 17 | Overhauling, replacement of both side bearings, application of varnish on winding, testing and installation as detailed in scope of work complete with supply of all the material necessary for completion of the work for Ceiling Fans /Wall mounting fans/ Exhaust fans of rating upto 200W (without painting) |
| 18 | Supply and replacement of one set of 6201 & 6202 sealed bearingsin ceiling fan. |
| 19 | Enamel Painting of PCC panels, DG & DG Control panel, Feeder pillers, DBs,Switch Boxes & Pull Boxes of different sizes with one coat of primer and one coat of paint of approved shade after derusting and cleaning as directed bythe Engineer-in-Charge, including supply of all the materials required for the works. |
| 20 | Supply and embedment ofupto 25/32 mm Heavy Duty PVC circularRigid conduit for Electrical Wiring, conforming to IS 9537-1983 amended and revised upto date including supply of couplers and PVC Conduit accessories for Electrical Wiring conforming to IS 3419-1976 amended and revised upto date as detailed in the specificationandfinishing, painting of the patches to match the walland as directed by Engineer-in-charge in RCC Roof slabs, Floors, Walls, Columns, Beams, Brick/Concrete Block Masonry,etc, including supply of required conduit& accessories, and all material for masonry & GI draw wire.(Note: Approved make by the department for PVC Conduits & Accessories: AVON PLAST ) |
| 21 | Removal of old pull boxes & Embedment of new GI Boxes, providing of Hylum covers and termination of wires in Boxes of size upto 12 Module. Required modular boxes only shall be supplied as free issue material by department. |
| 22 | Removal of old switch boxes & Embedment of new GI Boxes, assembling of switches & sockets and termination of wires in Boxes of size upto 12 Module. Required modular boxes only shall be supplied as free issue material by department. |
| 23 | Supply and installation of PVC casing capping and wiring as directed by Engineer-in charge. Required PVC wires for wiring only shall be provided by the department as free issue material. All other material for the completion of the work is in the scope of the contractor. |
| 24 | Cleaning of bushes, plants, garbage material etc. and making good in the surrounding area up to Two feet on all sides of Street Light poles/PTLs as directed by the Engineer-in-charge.. |
| 25 | Glanding & End termination of following armoured aluminium cables including supply of glands, cable termination accessories, and earthing of cable glands as detailed in the enclosed specification for 4 C x 10/16 sq.mm armoured aluminium cables . |
| 26 | Glanding & End termination of following armoured aluminium cables including supply of glands, cable termination accessories, and earthing of cable glands as detailed in the enclosed specification for 3.5 C x 35/70/120 sq.mm armoured aluminium cables. |
| 27 | Installation & Testing of Raychem LT Cable Joint Kits suitable for PVC/XLPE Aluminium armoured cables in following sizes for 3-1/2 C x 400 sq.mm |
| 28 | Installation & Testing of Raychem LT Cable Joint Kits suitable for PVC/XLPE Aluminium armoured cables in following sizes for 3-1/2 core cable more than 120 but up to 185 sq.mm |
| 29 | Installation & Testing of Raychem LT Cable Joint Kits suitable for PVC/XLPE Aluminium armoured cables in following sizes for 3-1/2 core cable more than 70sqmm but up to 120 sq.mm |
| 30 | Installation & Testing of Raychem LT Cable Joint Kits suitable for PVC/XLPE Aluminium armoured cables in following sizes for 4 C x 10/16 sq.mm |
| 31 | Supply and replacement of 50 W LED Fitting for direct replacement on street lighting poles including minor modifications/repairs and related wiring. |
| 32 | Supply, installation, wiring and testing of 35 Watts LED PTL light fittings for Area Lighting. |
| 33 | Supply & Installation of RCC Cable route markers as detailed in the drawing containing various alphanumerical text as directed by Engineer-in-charge |
| 34 | Supply, installation and modification of wiring for 18/20 W Four Feet LED Tube in Box type fittings as detailed in scope of work. |
| 35 | Supply and installation ofFour FeetBox typeFittingonly including wiring at height on open ceiling/brick or concrete walls etc.as detailed in scope of work. |
| 36 | Supply of reputed make 2.5 MFD Capacitor for direct replacement in ceiling fan. |
| 37 | Supply of reputed make PVC Angle Holder for direct replacement in light fitting. |
| 38 | Supply of 2KW Heating Coil for direct replacement in Geyser. |
| 39 | Maintenance of Tataplay DTH HD connections including top up of Annual Subscription for each client ID. |
| 40 | Supply and replacement of HD Set Top Boxes for the Tataplay HD connections. |
| 41 | Supply and replacement of Power Adaptor for Tataplay HD Set Top Boxes. |
| 42 | Supply and replacement of Remote Control for Tataplay HD Set Top Boxes. |
| 43 | Supply and replacement of Antenna for Tataplay HD Connections. |
| 44 | Supply and replacement of LNB for the Tataplay HD connections. |
| 45 | Supply and Installation of 10 A Crabtree Switches |
| 46 | Supply and Installation 16 A Crabtree Switches |
| 47 | Supply and Installation 10 A Crabtree 5 Pin Sockets |
| 48 | Supply and Installation 2 Modular Crabtree Cover |
| 49 | Supply and Installation 4 Modular Crabtree Cover |
| 50 | Supply and Installation 2 Modular Crabtree Fan Regulator |
| 51 | Supply and Installation 1 Modular Crabtree Dummy Plate |
| 52 | Supply and Installation 1 Modular Crabtree Indicator |
| 53 | Supply and Installation 10W LED Bulkhead light fittings |
| 54 | Supply and Installation 225 mm Exhaust Fan |
| 55 | Supply and Installation 9W LED Bulb B22 Cap White |
| 56 | Supply and Installation 4W LED Bulb E14 Cap, Warm White / White |
| 57 | Supply and Installation 9W LED Bulb E27 Cap, Warm White / White |