| 1 | SAFE LOADING CARRIAGE & UNLOADING OF FOLLOWING MATERIALS FROM CENTRE STORE, LAKHIMPUR TO DIFFERENT WORK SITES AND ITS STACKING DISTANCE APPROX (55-100) KMS |
| 2 | LINE MATERIAL |
| 3 | PCC POLE |
| 4 | STP POLE 11 MTR. LONG |
| 5 | T/F16/25/63 KVA |
| 6 | T/F100/250 KVA |
| 7 | T/F/400/630 KVA |
| 8 | ACSR RABIT/DOG/RACOON/WEASEL/CONDUCTOR |
| 9 | ABC (3X120/95/70/25/16) SQMM |
| 10 | 11KV XLPE CABLE (3X35/70/120/185/240) |
| 11 | 11 KV PILFER RESISTANT MATRIAL CUBICAL |
| 12 | 11KV POLE MOUNTED CT/PT |
| 13 | DP BOX 1 PHASE / 3 PHASE |
| 14 | FABRICATION, ERECTION OF SUB-STATION TYPE DOUBLE POLE ON 8.5 MTR LONG PCC/11MTR LONG ST POLE ALONG WITH FIXING OF NECESSARY HARDWARE OF DOUBLE POLE ALONG WITH NECESSARY PIN INSULATOR AS PER RESSPO SPECIFICATION COMPLETE IN ALL RESPECT. |
| 15 | DRAGGING OF ST/PCC POLE TO PIT SITE DIGGING OF PIT ERECTION AND GROUTING (AS PER RESSPO NORMS) INCLUDING PROVIDING ALL DECENTRALISED MATERIAL REQUIRED FOR COMPLETION OF WORK . WORK IS TO BE CARRIED OUT AS PER RESSPO SPECIFICATION COMPLETE IN ALL RESPECT. |
| 16 | FABRICATION, ERECTION, T-OFF POLE SINGLE SECTION POLE ALONG WITH T-OFF CHANNEL CLAMP DISC FITTING & PIN ACCESSORIES, GROUNTING IN 1:4:8 CEMENT , BRICK BALLAST AND RIVER SAND AS PER RESSPO SPECIFIATION |
| 17 | GROUTING OF PCC/ST POLE WITH CEMENT, BRICKS BALLAT AND RIVER SAND RATIO 1:4:8 |
| 18 | PROVIDING NUT BOLTS WASHERS OF DIFFERENT SIZES |
| 19 | ORDINARY EARTHING BY MS EARTH ROD 2500MM LONG AS PER RESSPO SCHEDULE. ONLY GI WIRE & EARTH ROD SHALL BE SUPPLIED BY THE DEPARTMENT |
| 20 | FABRICATION ERECTGION T-OFF POLE SINGLE SECTION POLE ALONGWITH T-OFF CHANNEL,CLAMP ,DISK FITTING AND PIN ACCESSORIES |
| 21 | GROUTING AND NUZZLING OF STAY SET COMPLETE INCLUDING ITS GROUTING BY CIVIL MATERIAL (CEMENT, BRICK BALLAST AND RIVER SAND ) ONLY STAY WIRE SHALL BE SUPPLIED BY THE DEPARTMENT |
| 22 | LAYING AND SAGGING OF 3 PHASE 3 WIRE 11KV LINE ON ACSR WEASE/RABBIT/RACCOON/DOG CONDUCTOR AS PER RESSPO SPECIFICATION AND DIRECTION OF E/I |
| 23 | PROVIDING AND FIXING OF GUARDING ANGLE ON EXISTING 11KV SUPPORT WITH CLAMP AND NUT BOLTS |
| 24 | CRADLE GUARDING IF HT LINE BY GI WIRE SHALL BE SUPPLIED BY THE DEPARTMENT |
| 25 | ERECTION & COMMISIONING OF AB CABLE (3X120/95/70/25/16SQ.MM) |
| 26 | LAYING OF CABLE 11KV XLPE CABLE (3X35/70/120/185/240) SQMM IN PAKKA ROAD BY BORING METHOD LAYING CABLE AS PER RESSPO SPECIFICATION & DIRECTION OF E/I |
| 27 | LAYING OF CABLE 11KV THROUGH PIPING |
| 28 | HOISTING OF 11KV XLPE CABLE WILL BE PASSED THROUGH MS PIPE OF REQUIRED SIZE DULY CLAMPED WITH POLE AT THE BOTTOM MIDDLE AND TOP OF THE POLE |
| 29 | SUPPLY AND FIXING OF 11KV CABLE JOINING KIT O/D AND I/D |
| 30 | INSTALLATION OF 11 KV CT/PT ON DOUBLE POLLE CONNECT WITH METERING UNIT ALONG WITH PROVIDING AND FIXING OF ALL REQUIRED ACCESSORIES SUCH AS S/S BASE, MS FLAT, CLAMPS NUT AND BOLTS JUMPERING AND COMMISIONING |
| 31 | CONSTRUCTION OF BRICK MASONRY PLINTH SUITABLE FOR INSTALLATION OF 11KV PILFER METERING CUBICAL ALONG WITH PLASTERING. |
| 32 | DRAGGING OF 11KV PILFER METERING CUBICAL INSIDE THE METERING ROOM, ITS INSTALLATION AND COMMISIONING. |
| 33 | FIXING OF 1 PHASE / 3 PHASE DISTRIBUTION BOX/ KIOSK ON THE LT POLES INCLUDING ALL CLAMPS AND METERIAL REQUIRED FOR MOUNTING CONNECTIONS AND SEALING. |
| 34 | HIGH PRESSURE TESTING OF 11 KV(3X35/70/12/185/240)XLPE ALONG WITH ARRANGEMENT OF HIGH PRESSURE EQUIPMENT. |
| 35 | PROVIDING OF HOLDING CLAMP FOR TOP DROPPER T/F |
| 36 | PROVIDING OF HOLDING CLAMP FOR PCC/STP POLES |
| 37 | PROVIDING OF F CLAMP FOR PCC /STP POLES |
| 38 | DRILLING CUTTING AND MAKING OF HOLE. |
| 39 | CUTTING AND CHOPPING OF TREE BRANCHES FOR CLEARENCE OF HT/LT LINE AFTER CLEARANCE LINE THROUGHOUT PIECES OF TREE BRANCHES OF SITE AS AND WHEN REQUIRED FOR COMPLETION OF WORK. |
| 40 | SAFE INSTALLATION & ENERGISATION OF 16/25/63 KVA T/F ON DOUBLE POLE BY PROVIDING AND FIXING OF L PIECE LUGS MAKING HT/LT CONNECTION AND ITS COMMISIONING ONLY TRANSFORMER SHALL BE SUPPLIED BY THE DEPARMENT. |
| 41 | SAFE INSTALLATION & ENERGISATION OF 100/250/400/630 KVA T/F ON PLINTH BY PROVIDING AND FIXING OF L PIECE LUGS MAKING HT/LT CONNECTION AND ITS COMMISIONING ONLY TRANSFORMER SHALL BE SUPPLIED BY THE DEPARMENT. |
| 42 | FIXING OF WELL TYPE EARTHING 01 NO NUTRAL BODY AND 01 NO BODY COMPLETE IN ALL RESPECT AS PER RESSPO SPECIFICATION. |
| 43 | CONSTRUCTION OF PLINTH 2 METER X 2 METER X 1.5 METER FOR 100/250/400/630 KVA. TRANSFORMER PLINTH WALL SHALL BE BRICK/ STONE MASONRY OF 230 MM THICK, OUTSIDE OF THE WALL TO BE PLASTERED WITH 18 MM THICK CEMENT MORTAR (1:3), INSIDE OF THE PLINTH SHALL BE FILLED WITH BORROWEDSAND DULY COMPACTED R.C.C. TOP SLAB (1:2:4) SHALL BE 75 MM THICK (CONSTRUCTION OF PLINTH SHOULD COMPLY WITH RESSPO NORMS) |
| 44 | PROPER WIRE MESH FENCING OF TRANSFORMER ALONGSIDE THE PLINTH. THE HEIGHT OF THE FENCE SHOULD BE 7 FEETS ABOVE FROM GROUND, PROVIDING FABRICATION AND FIXING THE MAIN GATE IN FRONT OF THE PLINTH WITH PROVISION FOR LOCKING SYSTEM. PAINTING OF ENTIRE METAL WORKS/ MAIN GATE WITH WIRE MESH WITH BUS GREEN SUPER ENAMELED PAINT IN TWO COATS ON THE PRIMER COAT OF RED OXIDE. COMPLETE IN ALL RESPECT |
| 45 | GST EXTRA Please Enable Macros to View BoQ information |