| 1 | Taking / liftingout defective submersible pumps set of capacity 35/30 HP from bore well complete with column pipe steel rope, submersible cable and accessories etc and relowering and commissioning the same after repairing works and testing complete all as specified and directed. |
| 2 | Dismantling , taking out complete burnt winding wire of submersible motor of capacity 35/30HP, and winding with PVC insulated copper wire of existing gauge as per motor capacity using new insulation material such as insulating paper sleeves etc.Including cleaning of statorslots replacement of defective parts and testing complete, replacement of submersible cable as required length complete all as specified and directed. |
| 3 | S&F in repair Motor bush of gun metal upper and lower for 35/30HP capacity (Set of two) complete all as specified and directed. |
| 4 | S&F in repair Rotor bearings sleeve upper and lower for 35/30HP capacity, (set of two) complete all as specified and directed. |
| 5 | S&F in repair Coupling arrangement with key for motor for 35/30HP capacity complete all as specified and directed. |
| 6 | S&F in repair Sand guard for submersible pump set for 35/30 HP capacity complete all as specified and directed. |
| 7 | S&F in repair Thrust bearing assembly for submersible pump set motor for the capacity 35/30 HP complete all as specified and directed. |
| 8 | S&F of Epoxy type cable jointing kit with all the jointing material, ferrule, for 1100 volts flat submersible copper conductor cable 16/10 Sqmm 3 core complete all as specified and directed. |
| 9 | S&F of Rubber gasket (packing) suitable for 80 to 150 mm dia flange complete all as specified and directed. |
| 10 | S&F Of MS Nut bolts with spring washers of any sizes complete all as specified and directed. |
| 11 | S&Fof Steel wire rope stranded 12 mm dia for hanging of submersible pump set complete all as specified and directed. |
| 12 | S&F of Electric cable for submersible pump set, flat 16 Sqmm 3 core stranded copper conductor PVC sheathed cable all as specified and directed. |
| 13 | All as per item No 12.00 above But of 25 Sqmm,3core complete all as specified and directed. |
| 14 | Dismantling submersible pump, straightening & polishing of pump shaft, making threading and key way, turning surfacing polishing to impellers, CI bowl complete including replacement of worn out parts as per requirement and all as directed of rating 45/40/30/20 HP 3 Phase complete all as specified and directed. |
| 15 | S&F of impeller with key and distance bushes for 35/30 HP capacity pump complete all as specified and directed. |
| 16 | S&F of Pump shaft of stainless steel suitable for 35/30 HP capacity pump complete all as specified and directed. |
| 17 | S&F of NRV for 35/30 HP capacity pump complete all as specified and directed. |
| 18 | S&F of Bearing bush for submersible pump for35/30 HP capacity complete all as specified and directed. |
| 19 | S&F of Bowl assembly for submersible pump set for the capacity 45/40/30/20 HP complete all as specified and directed. |
| 20 | S&F of Distance sleevesfor submersible pump for 35/30 HPcapacity complete all as specified and directed. |
| 21 | Repair/maint of LT panel /Starter of any size/type, checking and tightening of all incoming and outgoing connections by replacing alluminium lugs, pieces of burnt wires as required to make the starter /panel functional complete all as specified and directed. |
| 22 | S&F in repair Bus Bar of 100 A and 415 V 4 Nos and joining all incoming and outgoing connectiom by suitable Lugs complete all as specified and directed. |
| 23 | S&F in repair MCCB TP, 415V, 100 Amps with breaking capacity 16 KA complete all as specified and directed. |
| 24 | S&F in repair MCCB TP, 415V, 125 Amps with breaking capacity 16 KA complete all as specified and directed. |
| 25 | S&F in repair MCCB TP, 415V, 200 Amps with breaking capacity 36 KA complete all as specified and directed. |
| 26 | S&F in repair MCB32 Amps, TPN, 415 volts,\"C\" Curve AC 10 KA complete all as specified and directed. |
| 27 | S&F of in repair Power contactor TP as per existing type & make fitted at sitefor starter suitable for 35/30 HP submersible pump set complete all as specified and directed. |
| 28 | S&F in repair Over load relay for starter suitable for 35/30 HP submersible pump set complete all as specified and directed. |
| 29 | S&F in repair Timersuitable for star delta starter for 35/30 HP submersible pump set complete all as specified and directed. |
| 30 | S&F in repairfully automatic star delta starter for submerssible pump set including connecting all incoming and outgoing copper wire complete all as specified and directed. |
| 31 | S&F in replacementfully automatic star delta starter for submerssible pump set including connecting all incoming and outgoing copper wire complete all as specified and directed. |
| 32 | S&F in replacement change over switch on load type in open execution front handle operated415V with rating of125 Amps 4 pole 415 volt complete all as specified and directed. |
| 33 | S&F in replacement change over switch on load type in open execution front handle operated415V with rating of63 Amps 4 pole 415 volt complete all as specified and directed. |
| 34 | M&L for Pressure gauge size 100 mm dia round, range 0-10 Kg/cm2 complete with connecting pipe & air cock for 15 mm dia GI pipe complete all as specified and directed. |
| 35 | M&L for carrying out drinking water test as per IS 10500-2012 (72 parameters) viz, coliform, E coli aluminium (as Al), arsenic (as As), Boron (as B), Cadmium (as Cd), calcium (as Ca),chloride (as Cl), total Chromium (as Cr), colour Copper (as Cu), Cyanide (as CN) detergents,Flurides (as F), Iron (as Fe),Lead (as Pb),Deg c,phenolic compounds, residual free chlorine, selenium (as Se), solid dissolved (TDS), Sulphate (as SO4), taste, Total Alkalinity,Total Hardness (asCaCo3), Turbidity, Zinc (as Zn), ammonia as total ammonia N, Barium (as Ba),chloamines (as Cl2), silver as(Ag), sulphide (as H2S), molybdenum (as Mo), Nickel (as Ni), Trihalomethanes as (Bromoform, dibron, oehloromethane, bromodichloromethane, chloroform, mineral oil, polychlorinated biphenyl (PCB), polynuclear aromatic hydrocarbons (PAH) Total pesticides residues,radioactivity test (alpha & beta radiation) at an NABL accredited lab and submission of tests reports in 10 days time from date of collection of sample.Note :- Rate quoted by the bidder shall be deemed to included collection and transportation of samples in the manner prescribed by the lab supervisused by Engg-In-Charge. 2. Lab will be approved by from the GE prior to collection of samples.3. location and time of collection will be decided by Engg-In-Charge. |
| 36 | M&L for Earthing with GI plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main controlboard and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including taking down old unserviceable and making test point and all connections complete all as specified and directed. |
| 37 | Supplyonly MS column pipe of size 100 mmin standard length of 3.0 mtr, heavy duty duly threaded at ends with provision of MS flange duly drilled and welded complete all as specified and directed. |
| 38 | Supply onlyMS column pipe heavy Duty of size 150 mmin standard length of 3.0 mtr, heavy duty duly threaded at ends with provision of MS flange duly drilled and welded complete all as specified and directed. |
| 39 | Supply and fixing in replacement phase sequencer cum pump protection system 415/440volts, 50 Hz, internal working voltage 12/14 volt, suitable for 35/30 HP with MNX 100 comtactor capacity load for auto change of phase sequence if incommimg phase sequence changes, single phasing prevention system and adjustable low and high voltage protection system to protect the machinery, mounting on bracket made out 40x3 mm angle iron frame, all control wirings, cable connections complete all as specified and directed. |
| 40 | S& F (in Replacemnt) Electronic microprocessor based digital & wire less type water level indicator with alarm at time offull level/Low level in tank including all eqpts accomodated in GI sheet box or completely enclosed complete including testing & Commissioning complete all as specified and directed. |
| 41 | M&L for design, manufacture, supply, install and commission in replacement LED display boards of following sizes havingcompact design,and maintenance friendly.The base of the board made of ACP (Aluminium composite Panel) 3mm thick and back side of board covered with GI sheet 24 SWG, the letters and borders made of acrylic sheet 3mm thick of colour as approved by GE/Engr-in-charge.LED module should as per requirement of letter space,the display language may be English/ Hindi (Alpha Numeric), its visibility should be suitable for Day & Night (Out door application) and should be visible upto 25Mtr. (Minimum), the text effect should be static, the LEDsuitable for power supply 230 Volts/ 50Hz, AC, with switch ON and OFF the power supply to the display board.The board shall be suitably braced on back side with angle iron 40 mm x 40 mm x 3 mmand making good of disturbed surfaces as per original complete all as specified and directed. (a) Rectangular board having max 40 letters or characters in English language letter or character size, height not exceeding 255 mm and back depth Max 45 mm of suitable width & one logo of dia not exceeding 450 mm and back depth 80 mm. |
| 42 | M&L for framed work such as grills,gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors, ladders, framed balusters, walk ways, railings, framework of Ladder in Over Head Tankand similar work con-forming to Fe 290. Gde-E-165 all the articles shall be painted withtwo coat of food grain synthetic enamel paint over and including a coat of red oxideprimerafter preparation of steel surfaces complete all as specified and directed.Note :- Necessary safety tools and measure should be the whole responsiblity of contractor andnecessary supervisor for safty measure during the height work shall be included in quoted rates. |
| 43 | Supply installation, commissioning & testing (in replacement ) of LT Panel, 415 volts, TPN AC, 50Hz wall / floor mounted indoor type cubical made out of 2mm thick CRCA sheet weather, dust & vermin proof with rubber gasket with high class powder coating internally & externally fixing in position by provision of nut and bolts & addition/alteration required for fixing existing cables and connecting the all incoming/outgoing cables by suitable size of aluminium lugs stands nuts, bolts & washers including to accommodate properly following control switches:- (a) Aluminium bus bar TPN 200 Amps ratingmade of high conductivity aluminium strip of suitable length with sleeves.- 01 Set(b) Changover switch 200 Amp, 4 pole, open excution, front handle operated type - 01 No (c) MCCB TP with neutral link200 Amps, 35 CA , 415 volts, AC– 02 No (For incoming)(d) MCCB TP with neutral link100 Amps, 25 CA , 415 volts, AC– 01 No (For out going)(e) MCB TPN 32 Amps, 10 KA – 04 Nos (For out going) (f) MCB SPN 16 Amps, 10 KA – 02 Nos(For out going) (g) Ammeter Digital and programable type three phase 96 mm x 96 mm size with inbuilt selector switch with necessary CTs– 01 No(h) Voltmeter Digital and programable type three phase 96 mm x 96 mm size with inbuilt selector switch– 01 No(j) Indicator lamp LED RYB phases in different colours – 01 Set |
| 44 | M&L for boardmade out of 3mm thick thick plain white acrylic sheet of size 900mm x 600mm with painting of details of certail detailwith suitable paint as directed including suitable arrangement for fixing on wall with bracket/Aluminium Bidding etc. Note :All Details to be painted on Acrylic sheet complete all as specified and directed. |
| 45 | Supply & fixing in replacement of LED Post Top Lantern 45 watt warm whitemade in die cast aluminium housingand spun aluminium top reflector with decorative clear oval acrylic diffuser and IP-65 protectionCCT 6500K complete all as specified and directed. |
| 46 | M&L for repair/maint of monoblock pump set of 1/1.5 HP capacity by means of dismantling from foundation derusting of shaft filling of gland packing replacement of seal bearing etc necessary repair in foundation to make rigid the system and arrest the vibration complete all as specified and directed. |
| 47 | Dismantling the motor, taking out the burnt copper winding wire ofmotor 1/1.5 HP and Rewinding of motor with existing copper wire of existing gauge as per motor capacity using new insulation material such as insulating paper sleeves etc. bakinmg complete with super enamelled insulating varnishincluding cleaning of statorslotsand testing complete all as specified and directed. |
| 48 | M&L for liftingout submersible pumps set from bore well complete with column pipe steel rope, submersible cable includingcommissioning testingthe same after developing the bore well complete all as specified and directed. |
| 49 | Transportation charges for Air compressor/pump sets including all connected tools and materials To & From as per site position/requirement complete all as specified and directed. |
| 50 | Development of bore well by Air compressor capable to work at pressure range approx 300 to 500 PSI and capacityapprox1000 cfm continously for 48 hours to clean the slots of the pipe and to explore the possiblity of recouping of well with natural water table complete all as specified and directed. |
| 51 | Development of bore well by over pumpingfor 48 hours to clean the slots of the pipe and to explore the possiblity of recouping of well with natural water table complete all as specified and directed. |
| 52 | M&L for testing of yield of well by means of \"V\" notch, necessary T&P and equipments all as specified. |
| 53 | M&L for cleaning of RCC over head reservoir 100000 gallons capacity at 40/60 feet stagingincluding removal of all deposited scales, dirtand settled sand particles from intake of circulating pipe, cleaning with brushing, sweeping and brooming of inner and outer wall of the tank and washing the complete with bleaching powder soluting and M&L for painting to rising main,delivery pipe, wash out and over flow pipes of 150mm bore existing water mains with two coats of synthetic anamal paints andalso re-writing date of cleaning and marking of rising & delivery mains etc. Note :- 1.The work shall be carried out through only by trained staff with hygiene and safety equipments.2.Responsibility for insurance and safety of team will solely rest with the contractor.3. Cost of temporary supports such as props, jacks, scaffolding etc as required at site is deemed to be included in unit rates quoted.4.Contractor shall be responsible for cleaning of Honey bee nest on overhead tank before tank cleaning. |
| 54 | All as per item No 53.00 above but 150000 gallons complete all as specified and directed. |
| 55 | All as per item No 53.00 above but 200000 gallons complete all as specified and directed. |
| 56 | Supply and fixing of2.5 sqmm 2 Core Copper Flexible Cablewith suitable clamps complete all as specified and directed. |
| 57 | Supply and fixing of Aviation Light with all necessary connection complete all as specified and directed. |
| 58 | Supply, installation, commissioning and testing in replacement ofsubmersible pump set of capacity 80 Cubic meter per hourat 86 Mtr head inside the bore well comprising of SS impellors in CI casing with stainless steel shaft, leaded bronze bearing / bushes stainless steel shaft, sleeve complete all as per IS 8034 of 1989 complete with submersible motor AC 3 phase, 50 Hz, 380 to 440 Volt of 30 HP stainless steel tubing as per IS. |