Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Repair/servicing to complete DG set any make/model 380 KVA of any make water cooled diesel engine by taking out dismantling segregation of all parts and re-assembling after duly repair/replacement/ servicingof following new part fixing including all type machine work such as turning reaming etc washing cleaning, greasing, wires, gaskets, V belts, rubber hoses, cleaning of alternator by vacuum cleaner and greasing of bearing, replacement of engine oil, flexible coupling & all type nuts bolts washers & other minor parts as required at site and testing on completion at site. Note: Any other accesories found unserviceable that shall be replaced & paid under respective items of the Schedule complete all as specified and directed. |
| 2 | S&F in replacement of Lub oil filter element for 380 KVA DG set complete all as specified and directed. |
| 3 | S&F in replacement of Fuel filter elementfor 380 KVA DG set complete all as specified and directed. |
| 4 | S&F in replacement of dry type air cleanerfor 380 KVA DG set complete all as specified and directed. |
| 5 | S&F in replacement of V-belt of fan for 380 KVA DG set complete all as specified and directed. |
| 6 | S&F in replacement of bye pass filter for 380 KVA DG set complete all as specified and directed. |
| 7 | S&F in replacement of starting relay for 380 KVA DG set complete all as specified and directed. |
| 8 | S&F in replacement of Electronic governer Assy for 380 KVADG set complete all as specified and directed. |
| 9 | M&L for repalcement of complete wiring (copper multistrand cable) of DG set control panel any capacity as directed at site including thimble screw and sleaves etc complete all as specified and directed. |
| 10 | S&F for replacement of gauge lub oil pressure of DG set cap 380 KVA complete all as specified and directed. |
| 11 | S&F in replacement of hose pipe for of DG set cap 380 KVA complete all as specified and directed. |
| 12 | S&F in replacement of radiator hose pipe of DG set cap 380 KVA complete all as specified and directed. |
| 13 | Dismantling and taking out fuel injector pump assembly suitable for 380 KVA DG Set and complete overhauling of FIP including replacement of unserviceable parts like rebuild overhauling kit, rebuild seal kit, fuel injector \"O\" rings, OEM gaskets, spring gasket injector, valve bearing etc complete all as specified and directed. |
| 14 | S&F in replacement of Clamp hose radiator of 380 KVA DG set complete all as specified and directed. |
| 15 | S&F in replacement of water body assy of DG set 380 KVAcomplete all as specified and directed. |
| 16 | Taking out Turbocharger of DG set Cap 380 KVA and replacement of Compressor Housing, Compressor Wheels, Turbine housing, Turbine Wheel, Wastegate Acuator with clamps, setting, caleberation and testing complete all as specified and directed. |
| 17 | Dismantling and taking out self starter assembly suitable for 380 KVA DG Set and replacement of wornout spare parts like field coil, armature assembly, solenoid assembly, corbon brush, corbon brush assembly, clutch plate assembly and bushes including servising and refixing to engine complete all as specified and directed. |
| 18 | S&F in replacemnt of AVR (Automatic Voltage Regulator) for DG set of capacity 380 KVA complete all as specified and directed. |
| 19 | S&F in replacement of rectifier assy comprising of 230/24/12/V step down transformer heavy duty copper wound and 24/ 12 V DC full wave rectifier unit for DG set 380 KVA as site rquirement complete all as specified and directed. |
| 20 | Repair of PT (Pressure time) fuel pump by dismantling and segration all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring governer plug etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts, calibration for DG set of capacity 380 KVA & testing on completion complete all as specified and directed. |
| 21 | Repair/ servicing to radiator assy cleaning washing throughly, descaling and M&L for replacement of rubber size pad and MS Nut & bolts including brazing / repair of cooling tubes with dismantling and segregation upper and lower chamber (tank) including and reassembling incl nut, bolt, washer & spring any type of DG set capacity 380 KVA complete all as specified and directed. |
| 22 | S&F in microprocessor digital type DG set controller ofcapacity 380 KVA (Make of DG set Cummins & Greaves cotton) including connect all control wiring & programming all the parameter related to DG set at site complete all as specified and directed. |
| 23 | S&F in replacement battery terminal bolt type suitable for any type of battery complete all as specified and directed. |
| 24 | Disconnecting incoming / outgoing cable connection from alternator of 380 KVA DG set and taking out from DG set room checking carefully and transporting to auth workshop for repair and rewinding of alternator AC/ DC winding coils, dismantling into parts and cutting the burnt/ damage copper winding wire from alternator / stator cleaning slots and rewinding the stator/alternator with super enamelled copper winding wire of existing gauge & size and insulation paper etc complete varnishing of rewinded alternator replacement of carbon brush set bearing set etc complete and transporting the alternator to DG set room coupling with DG set and testing complete include water load test complete all as specified and directed.NOTE: All neccessary T&P for dismantling,transporting and installation cost shall be deemed included in quoted rate. |
| 25 | Repair/servicing to complete DG set any make/model 75 KVA water coolent diesel engine by taking out dismantling segreagation of all parts and reassembling after duly repair/replacement of following new part fixing including all type machine work such as turning reaming etc washing cleaning greasing , wires replacement of engine oil, gaskets, flexible coupling & all type nuts bolts washers & other minor parts as required at site and testing on completion at site. Note: Any other accesories found unserviceable that shall be replaced & paid under respective items of the Schedule complete all as specified and directed. |
| 26 | S&F in replacement of Lub oil filter element for 75 KVA DG set complete all as specified and directed. |
| 27 | S&F in replacement of Fuel filter elementfor 75 KVA DG set complete all as specified and directed. |
| 28 | S&F in replacement of dry type air cleanerfor 75 KVA DG set complete all as specified and directed. |
| 29 | S&F in replacement of V-belt of fan for75 kVA DG set complete all as specified and directed. |
| 30 | S&F in replacement of Electronic governer Assy for 75 KVA DG set complete all as specified and directed. |
| 31 | S&F in replacement of starting switch for 75 KVA DG set complete all as specified and directed. |
| 32 | M&L for replacement of complete wiring (copper multistrand cable) of DG set control panelof capacity 75 KVA including thimble screw and sleaves etc complete all as specified and directed. |
| 33 | S&F for replacement of gauge lub oil pressure of DG set cap 75 KVA complete all as specified and directed. |
| 34 | S&F in replacement of hose pipe for of DG set cap 75 KVA complete all as specified and directed. |
| 35 | S&F in replacement of radiator hose pipe of DG set cap 75 KVA complete all as specified and directed. |
| 36 | Dismantling and taking out fuel injector pump assembly suitable for 75 KVA DG Set and complete overhauling of FIP including replacement of unserviceable parts like rebuild overhauling kit, rebuild seal kit, fuel injector \"O\" rings, OEM gaskets, spring gasket injector, valve bearing etc complete all as specified and directed. |
| 37 | S&F in replacement of Clamps for hose rediator of DG set 75 kVA complete all as specified and directed. |
| 38 | S&F in replacement of water body of DG set 75 KVA complete all as specified and directed. |
| 39 | Taking out Turbocharger of DG set Cap 75 KVA and replacement of Compressor Housing,Compressor Wheels,Turbine housing,Turbine Wheel,Wastegate Acuator with clamps,setting, caleberation and testing complete all as specified and directed. |
| 40 | S& F in replacement Turbo charging assembly of DG set 75 KVA complete all as specified and directed. |
| 41 | S&F replacement of self starter 12/24 volt for Dg set 75 kVA complete all as specified and directed. |
| 42 | S&F in replacement of AVR (Automatic Voltage Regulator) for DG set of capacity 75 KVA complete all as specified and directed. |
| 43 | S&F in replacement of rectifier assy comprising of 230/24/12/V step down transformer heavy duty copper wound and 24/ 12 V DC full wave rectifier unit as per sample for DG set 75 kVA as site rquirement complete all as specified and directed. |
| 44 | Repair of PT (Pressure time) fuel pump by dismantling and segration all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring governer plug etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts, calibration for DG set of capacity 20 to 75 KVA & testing on completion complete all as specified and directed. |
| 45 | Repair/ servicingto radiator assy cleaning washing throughly, descaling and M&L for replacement of rubber size pad and MS Nut & bolts including brazing / repair of cooling tubes with dismantling and segregation upper and lower chamber (tank) including and reassembling complte incl nut, bolt, washer & spring any type of DG set capacity 20 to 75 kVA complete all as specified and directed. |
| 46 | Disconnecting, dismantling & repair to dynamo with segregation of all parts supply and fix in replacement of armature field, coil carbon bush and bearing etc reassembling of capacity 75 kVA DG Set complete & testing on completion complete all as specified and directed. |
| 47 | S&F in microprocessor digital type DG set controller of DG set of capacity 75 KVA (Make of DG set kirloskar & Greaves cotton) including connect all control wiring & programming all the parameter related to DG set at site complete all as specified and directed. |
| 48 | Disconnecting incoming / outgoing cable connection from alternator of 75 KVA DG set and taking out from DG set room checking carefully and transporting to auth workshop for repair and rewinding of alternator dismantling into parts and cutting the burnt/damage copper winding wire from alternator / stator cleaning slots and rewinding the stator/alternator with super enamelled copper winding wire of existing gauge & size and insulation paper etc complete varnishing of rewinded alternator replacement of carbon brush set bearing set etc complete and transporting the alternator to DG set room coupling with DG set and testing complete include water load test complete all as specified and directed.NOTE: All neccessary T&P for dismantling, transporting and installation cost shall be deemed included in quoted rate. |
| 49 | M&L for replacement of coolant for DG setMake Castral/ Bosch/ Gulf complete all as specified and directed. |
| 50 | M&L for replacement of Engine oil 15W40 (As per OEM recommendation) complete all as specified and directed. make : Make Castral/ Bosch/ Gulf |
| 51 | Supply and fix in replacement engine Hrs run meter digital type suitable to match with existing system of DG set complete all as specified and directed. |
| 52 | Repair/ overhauling of self starter 12/24 Volts of any make/capacity including replacement of minor items such as carbon bushes, nuts, bolts, etc as per site requirement complete all as specified and directed. Note: All additional spares as required for smooth functioning of DG set complete all as spdf & as dirceted. |
| 53 | S&F in replacement lead acid battery 12 volts 180 AH heavy duty maint free complete including initial charging complete all as specified and directed. |
| 54 | Supply & pouring distilled water for maint of batteries complete all as specified and directed. |
| 55 | Repair/ maintenance/ servicing & replacement of spare parts of (RECD) Retrofit Emission Control Device fixed with 380 KVA DG set including all kind of repairs, rectification of damages, cleaning of complete RECD assembly & replacement of defective spare parts. The parameters & activities to be measured/ checks during service are as follows; -Data Parameters(a) Exhaust pre back-pressure at load(b) Exhaust post back-pressure at load(c) Exhaust pre back-pressure with load(d) Exhaust pre back-pressure without load(e) Noise level at 1m distance from DG set Vibration leve(f) Load in amperes(g) Change relative to silences (please note CPCB procedure cannot be adhered onsite)(h) ISOXXXX limit(i) IOT installed |
| 56 | General Inspection Activity(a) Damage in any external/ internal seal (b) Check for type of fuel/ engine oil used in DG set(c) Status of foundation(d) Sturdiness of structure(e) Rust (any component)(f) Loosening of nuts & Bolts(g) Exhaust leakage at inlet coupler(h) Exhaust leakage at inlet cover plate(i) Exhaust leakage at outer coupler(j) Exhaust leakage at outer cover plate(k) External dents/ damages (any component) (l) Damage in cladding(m) Damage in Electrical components such as Panel, cable tray wire conduit, wires etc. |
| 57 | Automation check(a) ISS operation via Panel (Auto)(b) ISS operation via Panel (Manual)(c) ISS operation via Manual override(d) Zero error in sensors(e) Calibration Error(f) Data logging on server(g) Working of controller, Indicators, display etc(h) Damage Anomaly in any other componentsDOFF Inspection & cleaning (a) Dents/ Damage – OC (b) Cleaning – OC (c) Dents/ Damage – PRT (d) Cleaning – PRT (e) Damage in gaskets at inlet coupler (f) Damage in gaskets at inlet cover plate(g) Damage in gaskets at outlet coupler(h) Damage in gaskets at outlet cover plateNote:-(a) Replacement of any spare parts including transport & fixing charges included in the deemed rate.(b) Servicing & repair/ replacment as mentioned above must be carried out byn OEM only.(c) Test reports/ check results has to be submitted to Engr-In-Charge after every servicing. |
| 58 | All as per item no 55 above but for 75 KVA DG set complete all as specified and directed. |
| 59 | M&L for cleaning of RCC over head reservoir up to 100000 gallons capacity at 40/60 feet staging including removal of all deposited scales, dirt and settled sand particals from intake of circulating pipe, cleaning with brushing, sweeping and brooming of inner and outer wall of the tank and washing the complete with bleaching powder solution and M&L for painting to rising main, delivery pipe, wash out and over flow pipes of 150mm bore existing water mains with two coats of synthetic enamle paints and also re-writing date of cleaning and marking of rising & delivery mains etc.Note : 1. The work shall be carried out through only by trained staff with hygiene and safety equipments 2. Responsibility for insurance and safety of team will solely rest with the contractor.3. Cost of temporary supports such as props, jacks, scaffolding etc as required at site shall deemed to be included in quoted rate. |
| 60 | Taking / liftingout defective submersible pumps set from bore well complete with column pipe upto 150mm dia steel rope, submersible cable and accessories etc and relowering and commissioning the same after repairing works and testing complete of rating 20 to 40 HP 3 phase complete all as specified and directed. |
| 61 | Dismantling, taking out complete burnt winding wire of submersible motor including cleaning of statorslots replacement of defective parts and rewinding with existing type & gauge of copper winding wire pvc insulated as per motor capacity and using new insulation material such as insulating paper sleeves etc. replacement of submersible cable as required size/ length incl testing of rating 20 to 40 HP 3 phase complete all as specified and directed. Note : The cost of transportation from pump house/yard to workshop and workshop to pump house/yard shall deemed to be included in item rate quoted by contractor. |
| 62 | Dismantling submersible pump, straightening & polishing of pump shaft, making threading and key way, turning surfacing polishing to impellers, CI bowl complete including replacement of worn out parts as per requirement incl testing and of rating 20 to 40 HP 3 Phase complete all as specified and directed. Note : The cost of transportation from pump house/yard to workshop and workshop to pump house/yard shall deemed to be included in item rate quoted by contractor. |
| 63 | S&F in replacement of Motor bush of gun metal upper and lower for 20 to 40 HP capacity (Set of two) complete all as specified and directed. |
| 64 | S&F in replacement of Rotor bearings sleeve upper and lower for 20 to 40 HP capacity, (set of two) complete all as specified and directed. |
| 65 | S&F in replacement of coupling arrangement with key for motor for 20 to 40 HP capacity complete all as specified and directed. |
| 66 | S&F in replacement of Sand guard for submersible pump set for 20 to 40 HP capacity complete all as specified and directed. |
| 67 | S&F in replacement of Thrust bearing assembly for submersible pump set motor for the capacity 20 to 40 HP complete all as specified and directed. |
| 68 | S&F of Rubber gasket (packing) suitable for 80 to 150 mm dia flange complete all as specified and directed. |
| 69 | S&F in replacement of MS Nut bolts with spring washers of any sizes complete all as specified and directed. |
| 70 | S&F in replacement of Steel wire rope stranded 12 mm dia for hanging of submersible pump set complete all as specified and directed. |
| 71 | S&F in replacement of Electric cable for submersible pump set, flat 10 Sqmm 3 core stranded copper conductor PVC sheathed cable all as specified and directed.Make- Finolex/ Paragon/Havells |
| 72 | All as per item No 69.00 above but for 16 sqmm 3 core complete all as specified and directed. |
| 73 | S&F in replacement of impeller with key and distance bushes for 20 to 40 HP capacity pump complete all as specified and directed. |
| 74 | S&F in replacement of Pump shaft of stainless steel suitable for 20 to 40 HP capacity pump complete all as specified and directed. |
| 75 | S&F in replacement of NRV for 20 to 40 HP capacity pump complete all as specified and directed. |
| 76 | S&F in replacement of Bearing bush for submersible pump for 20 to 40 HP capacity complete all as specified and directed. |
| 77 | S&F in replacement of Bowl assembly for submersible pump set for the capacity 20 to 40 HP complete all as specified and directed. |
| 78 | S&F in replacement of Distance sleeves for submersible pump for 20 to 40 HP capacity complete all as specified and directed. |
| 79 | Disconnecting electrically, dismantling, taking out complete burnt winding wire of electric driven motor including cleaning of stator slots replacement of defective parts and rewinding with existing type & gauge of copper winding wire pvc insulated as per motor capacity and using new insulation material such as insulating paper sleeves etc.replacement of wires as required size/ length and refixing and connecting at site incl testing on completion of rating 20 HP phase complete all as specified and directed. Note : The cost of transportation from pump house/yard to workshop and workshop to pump house/yard shall deemed to be included in quoted rate. |
| 80 | Supply and lowering in replacementMS column pipe heavy duty of size 150 mmin standard length of 3.0 mtr, heavy duty duly threaded at ends with provision of MS flange duly drilled and welded incl gasket, nut, bolts and washers, complete all as specified and directed. |
| 81 | S&F in replacement of epoxy type cable jointing kit with all the jointing material, ferrule, for 1100 volts flat submersible copper conductor cable 16/10 Sqmm 3 core complete all as specified and directed.Make : M seal/Reychem/Birla 3 M |
| 82 | S&F in replacement of rubber mat 1x2 mtr 3 mm thick laid down in front of LT panel / bus bar ISI marked complete all as specified and directed. |
| 83 | Supply and fixing of in replacment CO2 fire extinguishers suitable for electrical fires, non toxic,leving no residue and will not harm machinary & electrical equipment complete with accessories of weight not less than 6 kg with suitable stand for ground complete all as specified and directed. |
| 84 | S&F in replacement of standard automatic star delta submersible pump starter (MUG 50 starter) suitable for three phase 415 volts 50 Hz submersible pump set of capacity 40 HP including dismantling/ taking down old unserviceable starter any type by disconnecting all electric connection and making all necessary connection with new including nuts, bolt, washer and copper thimble of size complete all as specified and directed |
| 85 | Supply, installation and testing digital type water level indicator of continuous wireless water level indiator with 7-segment LED display (56 mm height) to indicate water level of single/ multiple tanks (maximum 6 tanks) in percentage with 1% resolution, indicating flow status, audio/ visual alarm for full/ low/ overflow condition, display size not less then 426(H)x225(W)x95(D) complete all as specified and directed. |
| 86 | Supply , installation and testing digital top transmitter with upto 25 m height sensor & battery powered water level data transmitter with water level sensors to measure water level with 1-2% resolution and flow/ overflow status & transmit the data wirelessly to controller cum recever unit complete all as specified and directed. |
| 87 | Supply, installation and testing wireless data repeater for retransmitters/ other repeters to further extension of wireless operations all as specified and directed. Note - Any plumbing work, welding work, masonary work, drilling work & wiring work for fixing of item no 5 to 7 above are included in deemed rates complete all as specified and directed. |
| 88 | Supply and installation of GSM module, a communication interface gateway to communicate the data between web server and controller / level transmitters. UART protocol is used for communication between GSM and controller/ Repeater. The GSM unit will be equipped with SIM of cellular network provider for communication with server complete all as specified and directed. |
| 89 | Supply & providing web based remote Water level monitoring system by providing access to control/ information panel at Central server of minimum Tire-III level data centre in India. It will trigger SMS alerts for various events on crossing limits. The cost include only for access to server/ application and it does not include the cost of required hardware complete all as specified and directed. The cost of hardware will be charged seperately but the cost of running the services shall be deemed to included in quoted rate. |
| 90 | M&L for Yield testing of existing borewell of any size & capacity by removing the rising main pipe line connected with borewell, arranging \"V\" notch MS tank at site or leveling the ground & laying the PVC cover sheet over ground for pumping the water from borewel to pass water through the \"V\" fixed at end to note the level of water passing through the \"V notch & yield to be calculated & submitted to Engr-In-Charge complete all as specified and directed. |
| 91 | M&L for Electric logging of bore well perecise delineation of granular zones and also the quality of ground water including reports interpretation complete all as specified and directed. Note : (a) Electric logging shall be carried out by approved agency.(b) Unit rate quoted, developing and testing etc at side of work and renewal of the same on completion from the site including necessary supervison and rental charges of rig machine compressor and OP unit (any other T&P not specifically inventioned) and no extra payment shall be admissible on this account. |
| 92 | M&L for Developing the bore well with 600 PSI capacity air compressor as required until clear water is obtained including transportation, errection and dismantling of air compressor complete all as specified and directed. |
| 93 | Material & labour for Ductile iron fittings or special for flanged ends size up to 150 mm bore pipes conforming to IS : 1538, like bends (any radious and angle ) taper any type ( Straight, end increasing, decreasing or double socket etc) tail pieces single branches, Ý\" junction double branches,crosses (all flanged ends) complete all as specified & directed. |
| 94 | M&L in replacement to fixing ventuary/ orific arrangment made out of MS pipe 150 mm bore 7.0 mm thick 0.50 mtrs long (appx) including welding of flange at both end and five Nos socket of 20 mm bore with fixing of nipple and gate valve of size 20 mm bore and one No. reducer of size 50 x 20 mm complete all as specified and directed. |
| 95 | Excavation in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide in any type of soil for laying and taking out of GI/CI pipes complete all as specified and directed. |
| 96 | Returning filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 97 | Removing excavated soils to a distance not exceeding 50 m and depositing where directed at a level n. exc 1.5 mtr above the starting point complete all as specified and directed. |
| 98 | M&L for drilling hole at a depth up to 1.5 mtr below the normal ground level of suitable size to insert upto 150 mm dia pipe across the road in horizontal position complete all as specified and directed. |
| 99 | Disconnecting, dismantling and taking up or down for segregation of old/unserviceable/cracked GI tubing with fittings of size 15 mm bore including cleaning for refixing complete all as specified and directed. Note: Excavation and earth work shall be measured and paid separately under relevant items. |
| 100 | All as per item No 97.00 above but of size 20mm complete all as specified and directed. |
| 101 | All as per item No 97.00 above but of size 25mm complete all as specified and directed. |
| 102 | All as per item No 97.00 above but of size 40mm complete all as specified and directed. |
| 103 | All as per item No 97.00 above but of size 50mm complete all as specified and directed. |
| 104 | All as per item No 97.00 above but of size 80mm complete all as specified and directed. |
| 105 | Re-laying, jointing and testing old but serviceable GI tubing 15mm dia (obtained from srl item No-97) and connection in new or old portion incl new fittings such as bends, elbows, union, tees, reducers etc as required at site laid in trenches or on floor or wall complete and making good all disturbed surfaces of wall/ floor/ road/ path to match with existing specification complete all as specified and directed. |
| 106 | All as per item No 103.00 abovebut of size 20mm (obtained from srl item No-98) complete all as specified and directed. |
| 107 | All as per item No 103.00 abovebut of size 25mm (obtained from srl item No-99) complete all as specified and directed. |
| 108 | All as per item No 103.00 abovebut of size 40mm (obtained from srl item No-100) complete all as specified and directed. |
| 109 | All as per item No 103.00 abovebut of size 50mm (obtained from srl item No-101) complete all as specified and directed. |
| 110 | All as per item No 103.00 abovebut of size 80mm (obtained from srl item No-102) complete all as specified and directed. |
| 111 | Supply & Laying, jointing and leakage testing GI tubing medium grade 15mm bore with all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches/floor/walls and making good the disturbed surface to match with existing surface as (PCC work in 1:2:4 using 20 mm graded stone aggregate/ plastering in CM 1:4 and applying finishing coat of existing treatment) complete all as specified and as directed at site. Notes :(i) The laying and jointing of pipes are required to be carried out in short/ long streches catering to specific requirements of a purticular quarter or a group of blocks.(ii) Excavation & earth work shall be measured & paid seperately. |
| 112 | All as per item No 109.00 above but of size 20mm complete all as specified and directed. |
| 113 | All as per item No 109.00 above but of size 25mm complete all as specified and directed. |
| 114 | All as per item No 109.00 above but of size 40mm complete all as specified and directed. |
| 115 | All as per item No 109.00 above but of size 50mm complete all as specified and directed. |
| 116 | All as per item No 109.00 above but of size 80mm complete all as specified and directed. |
| 117 | Supply, Laying and testing in replacement old UNSV 3 layer PP-R polypropylene random copolymer concealed pipes SDR 7.4 (PN-16) & SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R Plain & brass threaded polypropylene random fitting of size 20mm complete all as specified and directed. Note:- Excavation and earth wrok shall be paid separately under relevant item of BOQ. |
| 118 | All as per item No 115.00 above but of size 25mm (outer diameter of pipe) complete all as specified and directed. |
| 119 | All as per item No 115.00 above but of size 32mm (outer diameter of pipe) complete all as specified and directed. |
| 120 | All as per item No 115.00 above but of size 40mm (outer diameter of pipe) complete all as specified and directed. |
| 121 | All as per item No 115.00 above but of size 50mm (outer diameter of pipe) complete all as specified and directed. |
| 122 | All as per item No 115.00 above but of size 63 mm (outer diameter of pipe) complete all as specified and directed. |
| 123 | All as per item No 115.00 above but of size 75 mm (outer diameter of pipe) complete all as specified and directed. |
| 124 | All as per item No 115.00 above but of size 90 mm (outer diameter of pipe) complete all as specified and directed.Note:- Item No 115 to 122 for PP-R pipes connecting fittings like PP-R (sockets, elbow, Tee sockets, reducer, unions and suitable tools & heater for joining the PPR sockets etc.. of both plain and brass threaded type shall be deemed to included in quoted rate. |
| 125 | Supply, installation, testing and commissioning and testing of power factor improvement panel of capacity 50 KVAR size of panel 900 mm x 600 mm x 200 mm, fully type test according to IEC 61921 including interconnection with LT panel with appropriate size of electric cable for Main panel,factory made, weather proof , dust and vermin proof (IP 65) suitable forHumidity: up to 95%,Average daily temperature: +35°C max,Ambient temperature: -5°C to 45°C, 1100 V/660 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 14 SWG MS sheet welded on 40 x 40 x 3 mm angle iron frame / base of appropriate size and having four Nos angle ironlegs made out of 40 x 40 x 6mm 60 cm long angle iron below frame with front door and back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:3:6 of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles , all as specified and directed by Engr-in-Charge and all other electric incoming and outgoing connections with PVC insulated multi stranded flexible copperNYVIN cable of suitable size and PVC flexible conduit medium quality as required of make (Havells/ schneider/ L&T/K), comprising following:- |
| 126 | (a) Insulated Bus bar of aluminium of 100 Amps capacity for three phase, fixed on insulators, Busbar should be PVC sleeved with Red, Yellow & Blue Colour, Bus bar support should be of SMC/DMC, Rated Impulse Withstand Voltage 8KV -01 Set(b) Incommer MCCB 100 Amp, three pole, short circuit breaking capacity 25 KA Icu at 415 V (KA rms) Ics =100% ,IEC 60947-2 Adjustable thermal and fixed magnetic setting ,frame LS type,Front Face,Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier.Make:- Schneider/ Siemens / ABB/L&T/Havells -1 No.(c) Capacitor 50 KVAR (03 X 12.5 KVAR + 01 X 7.5 KVAR + 01 X 3 KVAR + 01 X 2 KVAR), square type capacitor heavy duty rated, capacitor bankof rated 440 volt , 3 phase, Maximum over current: 1.8 In,Overpressure protection,Discharge resistance 50 V - 1 min, Capacitance Tolerance -5%, +10%,Maximum permissible over current(with thermal protection included)1.43 In ,Maximum permissible over voltage 1.1 x Un, 8 h every 24 h,of rated 440 volt with detuned Reactor of de-tuning factor (P) 7% and suitable output of 50 KVAR at 440 volt suitable output , Overheating protection by thermostatconfirming toIS-13340-1993/, 13341-1992 & IEC -60831-1+2. .Make:- Schneider/ Siemens / ABB/L&T/Havells(d) Intelligent Power factor controller relay 8 steps, seven segment LED Display, Augiliary power factor, Algotitham, Dual password protection 4 digit display, Alarm Indication on Display switching time programmable IS to 1809, 90V - 550V 50/60Hz 1A/5A with RS485 Make:- Schneider/ Siemens / ABB/L&T/Havells-01 No(e) SPMCB ,C-Curve, Control Circuit, .Make:- Schneider/ Siemens / ABB/L&T/Havells(f) CT 250/5A , 10 V.A,CL:1.0,Resin Cast ,CT Secondary wire Size should be 2.5 Sq mm.Make : Kalpa /AE/ L&T/Kappa -03 Nos |
| 127 | (g)Accessories for 50 KVAR capacitor Bank :-(i)Capacitor Duty Contactor (03 X 12.5 KVAR + 01 X 7.5 KVAR + 01 X 3 KVAR + 01 X 2 KVAR) 440 volt with damping resistors which limit inrush Current, 440 volt ,3ph,50 Hz, Coil-220 Vac, .Make:- Schneider/ Siemens / ABB/L&T/Havells(ii) MCB TPN 10 Amp, 10 KA, 240 Volt(iii) MCB TPN 16 to 25 Amp, 10 KA, 240 Volt(iv)Digital Voltmeter of size 96x96mm (0-500V) with built in selector switch.(v)Digital Ammeter of size 96x96mm (0-400A) with built in selector switch. (vi)Indication lamp 22.5mm dia LED type 240volts AC to show three phase availability-01Set.(h) Ventilating fans of required size to dissipiate the heat liberated by capacitor units complete with automatic switching ON and OFF of fans depending upon the temperature of the Panel. 230 V AC, 2650 rpm,160 Cu.m/h, Flying leads - 04 Nos (j) All accessories prewired with suitable size copper conductor cable insulated with fibre glass insulation to with stand high temperature, housed in cubical panel (CPRI approved) made out of 3.15 mm thick MS sheet factory made as per IEC 62208 duly powder coated front and rear door open able with locking arrangement complete with,IK 10 protection against mechanical Shocks as per IEC 62262 foundation as required or recommended by manufacturer. Make of APFC Panel Note: APFC Panel shall be manufacturedby original manufacturer like(Havells/ schneider/ L&T/K). The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf and the panels so manufactured will not be accepted. |
| 128 | Supply, installation, testing and commissioning and testing of power factor improvement panel of capacity 200 KVAR size of panel 1175 mm x 800 mm x 540 mm, fully type test according to IEC 61921 including interconnection with LT panel with appropriate size of electric cable for Main panel,factory made, weather proof , dust and vermin proof (IP 65) suitable forHumidity: up to 95%,Average daily temperature: +35°C max,Ambient temperature: -5°C to 45°C, 1100 V/660 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 14 SWG MS sheet welded on 40 x 40 x 3 mm angle iron frame / base of appropriate size and having four Nos angle ironlegs made out of 40 x 40 x 6mm 60 cm long angle iron below frame with front door and back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:3:6 of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles , all as specified and directed by Engr-in-Charge and all other electric incoming and outgoing connections with PVC insulated multi stranded flexible copperNYVIN cable of suitable size and PVC flexible conduit medium quality as required of make (Havells/ schneider/ L&T/K), comprising following:- |
| 129 | (a) Insulated Bus bar of aluminium of 400 Amps capacity for three phase, fixed on insulators, Busbar should be PVC sleeved with Red, Yellow & Blue Colour, Bus bar support should be of SMC/DMC, Rated Impulse Withstand Voltage 8KV -01 Set(b) Incommer MCCB 400 Amp, three pole, short circuit breaking capacity 35 KA Icu at 415 V (KA rms) Ics =100% ,IEC 60947-2 Adjustable thermal and fixed magnetic setting ,frame LS type,Front Face,Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier.Make:- Schneider/ Siemens / ABB/L&T/Havells -1 No.(c) Capacitor 200 KVAR (03 X 50 KVAR + 01 X 25 KVAR + 01 X 10 KVAR + 03 X 5 KVAR), square type capacitor heavy duty rated, capacitor bankof rated 440 volt , 3 phase, Maximum over current: 1.8 In,Overpressure protection,Discharge resistance 50 V - 1 min, Capacitance Tolerance -5%, +10%,Maximum permissible over current(with thermal protection included)1.43 In ,Maximum permissible over voltage 1.1 x Un, 8 h every 24 h,of rated 440 volt with detuned Reactor of de-tuning factor (P) 7% and suitable output of 200 KVAR at 440 volt suitable output , Overheating protection by thermostatconfirming toIS-13340-1993/, 13341-1992 & IEC -60831-1+2. Make:- Schneider/ Siemens / ABB/L&T/Havells(d) Intelligent Power factor controller relay 8 steps, seven segment LED Display, Augiliary power factor, Algotitham, Dual password protection 4 digit display, Alarm Indication on Display switching time programmable IS to 1809, 90V - 550V 50/60Hz 1A/5A with RS485 Make:- Schneider/ Siemens / ABB/L&T/Havells-01 No(e) SPMCB 6 to 32 amps, C-Curve, Control Circuit, Make:- Schneider/ Siemens / ABB/L&T/Havells(f) CT 250/5A , 10 V.A,CL:1.0,Resin Cast ,CT Secondary wire Size should be 2.5 Sq mm. Make : Kalpa /AE/ L&T/Kappa -03 Nos |
| 130 | (g)Accessories for 200 KVAR capacitor Bank :- (i)Capacitor Duty Contactor 200 KVAR (03 X 50 KVAR + 01 X 25 KVAR + 01 X 10 KVAR + 03 X 5 KVAR) 440 volt with damping resistors which limit inrush Current, 440 volt ,3ph,50 Hz, Coil-220 Vac, .Make:- Schneider/ Siemens / ABB/L&T/Havells (ii) MCB TPN 10 Amp, 10 KA, 240 Volt(iii) MCB TPN 16 to 25 Amp, 10 KA, 240 Volt(iv)Digital Voltmeter of size 96x96mm (0-500V) with built in selector switch.(v)Digital Ammeter of size 96x96mm (0-400A) with built in selector switch. (vi)Indication lamp 22.5mm dia LED type 240volts AC to show three phase availability-01Set.(h) Ventilating fans of required size to dissipiate the heat liberated by capacitor units complete with automatic switching ON and OFF of fans depending upon the temperature of the Panel. 230 V AC, 2650 rpm,160 Cu.m/h, Flying leads - 04 Nos (j) All accessories prewired with suitable size copper conductor cable insulated with fibre glass insulation to with stand high temperature, housed in cubical panel (CPRI approved) made out of 3.15 mm thick MS sheet factory made as per IEC 62208 duly powder coated front and rear door open able with locking arrangement complete with,IK 10 protection against mechanical Shocks as per IEC 62262 foundation as required or recommended by manufacturer. Make of APFC Panel Note: APFC Panel shall be manufacturedby original manufacturer like(Havells/ schneider/ L&T/K). The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf and the panels so manufactured will not be accepted. |
| 131 | Supply, install, testing and commissioning LT cubical Panel of outdoor type factory made dust/vermin proof made out of CRCA sheet 3.15 mm thick CPRI approved duly powder coated having opening and locking arrangementboth in front and rear side(independent door for each item on front side) mounted on 4 Nos angle iron 50x50x6 mm, 60 cm long embedded in PCC 1:3:6 type C2 with aluminium bus bar ofrating 1.5 times of incomer MCCB rated capacity, IP 65 protection, provision of holes at the bottom of panelto pass through cable with cable gland for incomming and outgoing cables with lugs and connections, sealed completely to avoid foreign particals entry into the panel,etc required nuts ,bolts and washer incl provision of lugs for cable terminationof 16 to 240 sqmm cable with MCCBs & control wiring with suitable size PVC copper conductor cable etc. Including provision of following accessories/eqpt incl cable gland etc and suitable for fixing of under mentioned items:- |
| 132 | Incoming(a) MCCB Adjustable thermal and fixed magnetic 4Pole 160 A 25 KA -No.01Make Havels Cat Part No - IHA13DB40160 or L&T/K Cat Part No - CM90642OOMO or Indoasian Cat Part No - 830295(b) Digital Voltmeter 0 to 500 Volt -01 No(c) Digital Ammeter 0 to 400 Amps with CTs and selector switch - 01 set(d) LED Phase Indication lamp (RYB) -01 Set(e) Cable gland double compression type weratherproof for 120 Sqmm 01 Nos Outgoing(a) MCCB Adjustable thermal and fixed magnetic 4Pole 63 A 25 KA -No.02 Make Havels Cat Part No - IHLASF0063 or L&T/K Cat Part No - CM91712OOJOOG or Indoasian Cat Part No - 830270(b) MCB TPN 10 to 32 amps - 4 Nos (01 No Spare)(c) Cable gland double compression type weatherproof for 95 Sqmm 3.5 core 01 Nos (d) Cable gland double compression type weatherproof for 70 Sqmm 3.5 core 01 Nos (e) Cable gland double compression type weatherproof for 50 Sqmm 3.5 core01 Nos(f) Cable gland double compression type weatherproof for 35 Sqmm 3.5 core 01 Nos (g) Cable gland double compression type weatherproof for 25 Sqmm 3.5 core 01 Nos (h) Cable gland double compression type weatherproof for 16 Sqmm 3.5 core 01 Nos |
| 133 | Supply, install, testing and commissioning LT cubical Panel of outdoor type factory made dust/vermin proof made out of CRCA sheet 3.15 mm thick CPRI approved duly powder coated having opening and locking arrangementboth in front and rear side(independent door for each item on front side) mounted on 4 Nos angle iron 50x50x6 mm, 60 cm long embedded in PCC 1:3:6 type C2 with aluminium bus bar ofrating 1.5 times of incomer MCCB rated capacity, IP 65 protection, provision of holes at the bottom of panelto pass through cable with cable gland for incomming and outgoing cables with lugs and connections, sealed completely to avoid foreign particals entry into the panel,etc required nuts ,bolts and washer incl provision of lugs for cable terminationof 16 to 240 sqmm cable with MCCBs & control wiring with suitable size PVC copper conductor cable etc. Including provision of following accessories/eqpt incl cable gland etc and suitable for fixing of under mentioned items:- |
| 134 | Incoming(a) MCCB Adjustable thermal and fixed magnetic 4Pole 63 A 25 KA -No.01Make Havels Cat Part No - IHLASF0063 or L&T/K Cat Part No - CM91712OOJOOG or Indoasian Cat Part No - 830270(b) Digital Voltmeter 0 to 500 Volt -01 No(c) Digital Ammeter 0 to 400 Amps with CTs and selector switch - 01 set(d) LED Phase Indication lamp (RYB) -01 Set(e) Cable gland double compression type weratherproof for 95 Sqmm 01 Nos Outgoing(a) MCCB Adjustable thermal and fixed magnetic 4Pole 63 A 25 KA -No.01Make Havels Cat Part No - IHLASF0063 or L&T/K Cat Part No - CM91712OOJOOG or Indoasian Cat Part No - 830270(b) MCB TPN 10 to 32 amps - 2 Nos (01 No Spare)(c) Cable gland double compression type weatherproof for 95 Sqmm 3.5 core 01 Nos (d) Cable gland double compression type weatherproof for 25 Sqmm 3.5 core 01 Nos (e) Cable gland double compression type weatherproof for 16 Sqmm 3.5 core 01 Nos |
| 135 | Supply, install, testing and commissioning LT cubical Panel of outdoor type factory made dust/vermin proof made out of CRCA sheet 3.15 mm thick CPRI approved duly powder coated having opening and locking arrangementboth in front and rear side(independent door for each item on front side) mounted on 4 Nos angle iron 50x50x6 mm, 60 cm long embedded in PCC 1:3:6 type C2 complete with aluminium bus bar ofrating 1.5 times of incomer MCCB rated capacity, IP 65 protection, provision of holes at the bottom of panelto pass through cable with cable gland for incomming and outgoing cables with lugs and connections, sealed completely to avoid foreign particals entry into the panel,etc required nuts ,bolts and washer incl provision of lugs for cable terminationof 16 to 240 sqmm cable in MCCBs 63 to 630 amps & control wiring with suitable size PVC copper conductor cable etc. Including provision of following accessories/eqpt incl cable gland etc and suitable for fixing of under mentioned items:- |
| 136 | Incoming(a) MCCB Adjustable thermal and fixed magnetic 4Pole 400 A 36 KA -No.01Make Havels Cat Part No -IHLLSEC40400 or L&T/K Cat Part No - CM98403OOROOG or Indoasian Cat Part No - 830396(b) Digital Voltmeter 0 to 500 Volt -01 No(c) Digital Ammeter 0 to 400 Amps with CTs and selector switch - 01 set(d) LED Phase Indication lamp (RYB) -01 Set(e) Cable Gland double compression type for 240 Sqmm 3.5 core 01 Nos Outgoing(a) MCCB Adjustable thermal and fixed magnetic 4Pole 160 A 25 KA -No.02(one spare) Make Havels Cat Part No - IHA13DB40160 or L&T/K Cat Part No - CM90642OOMO or Indoasian Cat Part No - 830295(b) MCCB Adjustable thermal and fixed magnetic 4Pole 100 A 25 KA -No.02 Make Havels Cat Part No - IHA13DB40100 or L&T/K Cat Part No - CM91712OOKOOG or Indoasian Cat Part No - 830272(c) MCCB Adjustable thermal and fixed magnetic 4Pole 63 A 25 KA -No.01. Make Havels Cat Part No - IHLASF0063 or L&T/K Cat Part No - CM91712OOJOOG or Indoasian Cat Part No - 830270(d) Cable Gland double compression type for 120 Sqmm 3.5 core02 Nos (e) Cable Gland double compression type for70 Sqmm 3.5 core 01 Nos (f) Cable Gland double compression type for50 Sqmm 3.5 core 01 Nos |
| 137 | Supply, install, testing and commissioning LT cubical Panel of outdoor type factory made dust/vermin proof made out of CRCA sheet 3.15 mm thick CPRI approved duly powder coated having opening and locking arrangementboth in front and rear side(independent door for each item on front side) mounted on 4 Nos angle iron 50x50x6 mm, 60 cm long embedded in PCC 1:3:6 type C2 complete with aluminium bus bar ofrating 1.5 times of incomer MCCB rated capacity, IP 65 protection, provision of holes at the bottom of panelto pass through cable with cable gland for incomming and outgoing cables with lugs and connections, sealed completely to avoid foreign particals entry into the panel,etc required nuts ,bolts and washer incl provision of lugs for cable terminationof 16 to 240 sqmm cable in MCCBs 63 to 630 amps & control wiring with suitable size PVC copper conductor cable etc. Including provision of following accessories/eqpt incl cable gland etc and suitable for fixing of under mentioned items:- |
| 138 | Incoming(a) MCCB Adjustable thermal and fixed magnetic 4Pole 200 A 25 KA -No.01Make Havels Cat Part No - IHLANDC40200 or L&T/K Cat Part No - CM90642OONO or Indoasian Cat Part No - 830296(b) Digital Voltmeter 0 to 500 Volt -01 No(c) Digital Ammeter 0 to 400 Amps with CTs and selector switch - 01 set(d) LED Phase Indication lamp (RYB) -01 Set(e) Cable Gland double compression type for 95 Sqmm 3.5 core 01 Nos Outgoing(a) MCCB Adjustable thermal and fixed magnetic 4Pole 100 A 25 KA -No.01 Make Havels Cat Part No - IHA13DB40100 or L&T/K Cat Part No - CM91712OOKOOG or Indoasian Cat Part No - 830272(b) MCCB Adjustable thermal and fixed magnetic 4Pole 63 A 25 KA -No.02. Make Havels Cat Part No - IHLASF0063 or L&T/K Cat Part No - CM91712OOJOOG or Indoasian Cat Part No - 830270(c) Cable Gland double compression type for70 Sqmm 3.5 core 01 Nos(d) Cable Gland double compression type for50 Sqmm 3.5 core 02 Nos |
| 139 | Supply andinstallation, connecting eclectically & commissioning in replacement of LT feeder pillar box outdoor type of suitable size,factory fabricated made out of MS sheet of thickness 3.15 mm front door openable with locking arrangement mounted on angle iron legs made out of angle iron of size 40x40x6mm, 1.5 mtr long, 1.0 mtr above ground level and 0.50 mtr embedded in PCC blocks of suitable size,duly painted with two coats of synthetic enamel paint over and including a coat of red oxidecomplete with 300 amps rated aluminium bus bar suitable for 3 phase 4wire supply system duly drilled holes and makingall cable connection with proper thimbles mounted on epoxy based post insulators and one MCCB 200 Amps 4 pole 415 Volt, 35/36 kA of make : Legrand/ Schneider/Havells/L&T complete all as required at site. |
| 140 | M&L for Earthing in replacement / renewal with galvanised steel earth plate electrode 600x600x6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised strip of size 32 x 6 mm earth continuity coductor by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR-I 2009, connected to main switch board all as specified. Necessary excavation, earthwork, PCC works and CI earth pit cover with watering pipe 20 mm dia GI Pipe medium grade, funnel with wire mesh and lugs, complete all as specified and directed. |
| 141 | Supply and Lay in replacement cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables(heavy duty) 1100V grade with stranded aluminium conductor of size 16 Sqmm 4 core complete all as specified and directed. |
| 142 | All as per item No. 131.00 above but of size 25 Sqmm 3.5 core complete all as specified and directed. |
| 143 | All as per item No. 131.00 above but of size 35 Sqmm 3.5 core complete all as specified and directed. |
| 144 | All as per item No. 131.00 above but of size 50 Sqmm 3.5 core complete all as specified and directed. |
| 145 | All as per item No. 131.00 above but of size 70 Sqmm 3.5 core complete all as specified and directed. |
| 146 | All as per item No. 131.00 above but of size 95 Sqmm 3.5 core complete all as specified and directed. |
| 147 | All as per item No. 131.00 above but of size 120 Sqmm 3.5 core complete all as specified and directed. |
| 148 | Supply and fixing of HDPE double wall corrugated (DWC) electric pipes of size 40 mm dia of 6 mtrs length each, manufactured using HDPE polymer having a smooth/plain internal surface & currugated external surface having with greater stiffness withstand soil movement & take higher loads (static & dynamic) incuding connecting rings made of HDPE DWC suitable for 40 mm pipes, to pass through LT cable complete all as specified and directed.Make Astral/SFMC/ KPT |
| 149 | All as per item No 138.00 above but of size 50 mm dia complete all as specified and directed. |
| 150 | All as per item No 138.00 above but of size 63 mm dia complete all as specified and directed. |
| 151 | Supply and laying RCC cable route indicator rectangular in shape providing cured shape on top, dimension not less then 250x150 mm at bottom below GL, 200x150 mm above GL & total height not less than 1250 mm fabricated in cement concrete (1:2:4) coloured yellow & mentioning cable size/ voltage & location in black colour, has to be engraved complete all as specified and directed. |
| 152 | S&F in repairMCCB4 pole 415V, Adjustable thermal and fixed magnetic type of capacity 63 Amps with breaking capacity 25 KA complete all as specified and directed. Make:- Havels Cat Part No - IHLASF0063 or L&T/K Cat Part No - CM91712OOJOOG or Indoasian Cat Part No - 830270 |
| 153 | S&F in repairMCCB4 pole 415V, Adjustable thermal and fixed magnetic type of capacity 100 Amps with breaking capacity 25 KA, complete all as specified and directed. Make:- Havels Cat Part No - IHA13DB40100 or L&T/K Cat Part No - CM91712OOKOOG or Indoasian Cat Part No - 830272 |
| 154 | S&F in repairMCCB4 pole 415V, Adjustable thermal and fixed magnetic type of capacity 125 Amps with breaking capacity 25 KA, complete all as specified and directed. Make:- Havels Cat Part No -IHA13DB40125 or L&T/K Cat Part No -CM90642OOLO or Indoasian Cat Part No - 830273 |
| 155 | S&F in repairMCCB4 pole 415V, Adjustable thermal and fixed magnetic type of capacity 160 Amps with breaking capacity 25 KA, complete all as specified and directed. Make:- Havels Cat Part No - IHA13DB40160 or L&T/K Cat Part No - CM90642OOMO or Indoasian Cat Part No - 830295 |
| 156 | S&F in repairMCCB4 pole 415V, Adjustable thermal and fixed magnetic type of capacity 200 Amps with breaking capacity 25 KA, complete all as specified and directed. Make :- Havells Cat Part No - IHLLSEB40200 orL&T/K Cat Part No -CM90642OONOor Indoasian Cat Part No -830296. |
| 157 | S&F in repairMCCB4 pole 415V, Adjustable thermal and fixed magnetic type of capacity 250 Amps with breaking capacity 36 KA, complete all as specified and directed. Make :- Havells Cat Part No -IHLLSEB40250 orL&T/K Cat Part No - CM92109OOP1OGor Indoasian Cat Part No -830336. |
| 158 | S&F in repairMCCB3 pole 415V, Adjustable thermal and fixed magnetic type of capacity 100 Amps with breaking capacity 25 KA,complete all as specified and directed. Make:- Havels Cat Part No - IHA13DB30100 or L&T/K Cat Part No - CM91612OOKOOG or Indoasian Cat Part No - 840038 |
| 159 | S&F in repairMCCB3 pole 415V, Adjustable thermal and fixed magnetic type of capacity 160 Amps with breaking capacity 25 KA, complete all as specified and directed. Make:- Havels Cat Part No - IHA13DB30160 or L&T/K Cat Part No - CM90642OOMO or Indoasian Cat Part No - 840100 |
| 160 | S&F in repairMCCB3 pole 415V, Adjustable thermal and fixed magnetic type of capacity 200 Amps with breaking capacity 25 KA, complete all as specified and directed. Make :- Havells Cat Part No -IHLLSEB30200 orL&T/K Cat Part No -CM90638OONOor Indoasian Cat Part No -840101. |
| 161 | S&F in repairMCCB3 pole 415V, Adjustable thermal and fixed magnetic type of capacity 250 Amps with breaking capacity 25 KA, complete all as specified and directed. Make : Havells Cat Part No - IHLLSEB30250 orL&T/K Cat Part No - CM90638OOPOor Indoasian Cat Part No -840102. |
| 162 | Supply and fixing in replacement MCB TPN 40 amps 415 V \"C\" curve with rupturing capacity 10 KA complete all as specified and directed. |
| 163 | Supply and fixing in replacement MCB TPN 63 amps 415 V \"C\" curve with rupturing capacity 10 KA complete all as specified and directed. |
| 164 | Supply and fixing in replacementMCB SPN 32-40 amps 230V \"C\" curve with rupturing capacity 10 KA complete all as specified and directed. |
| 165 | Supply and fixing in replacementMCB SPN 63 amps 230V \"C\" curve with rupturing capacity 10 KA complete all as specified and directed. |
| 166 | Supply and fixing in replacement MCB SP 6-16 amps 230V \"C\" curve with rupturing capacity 10 KA complete all as specified and directed. |
| 167 | Supply and fixing in replacement MCB SP 20-32 amps 230V \"C\" curve with rupturing capacity 10 KA complete all as specified and directed. |
| 168 | Supply and fixing in replacement MCB TP 40 amps 415 V \"C\" curve with rupturing capacity 10 KA complete all as specified and directed. |
| 169 | Supply and fixing in replacement MCB TP63 amps 415 V \"C\" curve with rupturing capacity 10 KA complete all as specified and directed. |
| 170 | Supply and fixing in replacement of off load change over switch in sheet metal enclosure 4 poles, 400 Amp rated, 440 volts, 50 Hzs, confirm to IEC 60947-3, IS/IEC 60947-3alongwith extendable handle with making all connection and fixing accessories on surface of wall/panel operating handle etc complete all as specified and directed. Make :- L&T / Havells/ Siemens |
| 171 | Supply and fixing in replacement of off load change over switch in sheet metal enclosure 4 poles, 200 Amp rated, 440 volts, 50 Hzs, confirm to IEC 60947-3, IS/IEC 60947-3alongwith extendable handle with making all connection and fixing accessories on surface of wall/panel operating handle etc complete all as specified and directed.Make :- L&T / Havells/ Siemens |
| 172 | Removal of unwanted vegetation/bushes/small plants shrubs around the water/electric supply installations/ inside the valve pit and surface excavation not exceeding 15 cm depth leveling the ground and removing the excavated material to a distance exceeding 50 M complete all as specified and directed.Note - (1) Tools including Cutting, Digging, grass/ bush cutting machine including fuel & oil has to be provided by contractor with machine operator & labour. |
| 173 | M&L for recharging to existed earthing in any type upto stranded value using required chemical such as Nacl/ MgSo4 / other approvad chemical incl reveting / welding/ boltingto earth lead incl testing etc by Tech rep with riveting bolting replacing to nut bolt and washer etcto GI earthing strip for making earth continuity from transformer / panels to earthing pit complete all as specified and directed.Note:- Contractor should be submit the bldg wise earthing test result of resistance value with user signature to departmentin duplicate will be submitted to engr-in-charge. |
| 174 | Attending complaints of STP at VRG line includingall type of repairs in Sewage Treatment Plant (STP) of capacity 100 cum/KLD including necessary repairing of pumps, motors, oiling,greasing, desludging etc and dozing of bleaching powder and running maintenance of horticulture pipe line within campus as per directions and satisfaction of Engineer-in-Charge and as working details are as under:- Note;- The contractor will attend all type of troubleshooting & break down within 24 hrs from the time of call. |
| 175 | M&L for testing of Sewage Treatment Plant treated water for BOD, COD, TSS and oil grease once in three months and submit report accordingly, test has to be carried out in NABL approved Lab complete all as specified and directed. Note :- test has to be carried out once in three months. |
| 176 | Comprehensive maintenance of Sewage Treatment Plant (STP) of capacity 100 cum/KLD including necessary minor repairing of pumps, motors, oiling, greasing, desludging etc and dozing of bleaching powder and running maintenance of horticulture pipe line within campus as per directions and satisfaction of Engineer-in-Charge and Following regular/ preventive maintenance to be carried out by the Contractor for smooth functioning of STP: (i) General maintenance of the system. (ii)Complete checking and running of the system.(iii) Checking and cleaning of feed pump and sewage pumps and blowers.(iv) Cleaning and backwash of sand filter.(v)Cleaning and backwash of carbon filter. (vi) Replacing of any spares required,(vii) Overhauling of motors and pumps. (viii)Addition/ replacement of FMR media if required.(ix) Checking of dosing chemicals and pumps.(x) Physical checking of running of plant.(xi) Supervising and guiding for desludging if required.(xii) Any other essential item or items not mentioned above to maintain functioning of STP.(xiii) Repair/ Maint of plant will be carried out by skilled/ trained personels only(xiv) Examine periodically all safty issues.(xv) The necessarry T & P/ safty equipments required shall be arranged by the Contractor and cost of the same shall be deemed to be included in the quoted rate. (xvi)All material of STP installation will be handed over to Contractor for safe custody at the time of commencement of CA and at the time of completion of the work Contractor will be handed over the same all material to department. (xvii)Rates are not including for manning in this item. |
| 177 | M&L for rewinding of Monoblock pump motor of capacity 5.5 KW/1500 RPM with PVC insulated copper wire of existing gauge as per motor capacity using new insulation material such as insulating paper sleeves etc.Including cleaning and replacement of defective parts and testing complete, replacement of cable as required length complete all as specified and directed. |
| 178 | Supply and fix in replacment of All-in-one solar lights of 20 watts Smart Integrated Solar Street Light with built in Mono Crystalline Panel, Lithium Ferro Phospate (LiFeP0 4) Battery, MPPT Charge Controller and PIR Sensor with Colour Temperature 6000-6500K. 2 days autonomy with dimming profile including earth/PCC work and suitable GI pole uptomtrs to fix thesolar lights complete all as specified and directed. Make:- Bajaj Cat No BSZSL 20W All-in-One Standard or Make Havells Cat No SOLAR AIO 20 W or Make Wipro Cat No -LR19-371-XXX-57-XX |
| 179 | All as per item No 168.00above complete all as specified and directed. Make:- Bajaj Cat No BSZSL 30W All-in-One Standard or Havells Cat No SOLAR AIO 30 W or Wipro Cat No -LR19-561-XXX-57-XX |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail