| 1 | Note:- (a) Debris obtained from any dismantling or demolition shall be removed beyond MOD land and rates shall be considered inclusive in respective items quoted rates.(b)Contractor shall be liable to taking down and refixing of IGL Gas pipe line and meters if required during execution of work through IGL representative.(c)Contractor shall be liable to repair of electric cable/OFC cable/pipe line, etc. (any description) if damaged during execution of work. (d)Work shall be executed in multistorey bldgs (i.e. upto G+8 incl Mumty). Rate of scoffolding/safety arrangements are included in item rates. No extra amount shall be paid. (e) As per requirement work may be excuted at any given site, within the AoR of AGE B/R-III (W) Delhi Cantt. |
| 2 | Dismantling wooden scantling work framed truss etc complete all as specified and directed. |
| 3 | Dismantling wrought iron or mild steel work of any description not otherwise provided for.complete all as specified and directed. |
| 4 | S&F mild steel rolled work as in roof trusses, (framed), trussed, purlin,crane tank stage gantries,rails and heavy bracket framing (Beam,angle,channel or flat section) including distance pieces,cleats etc,confirming to gradeFe 410 -W (GdeE- 250) quality-A, complete all as specified and directed. |
| 5 | S&F Mild steel screw bolts shank dia 10 to 12 mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long Fe-410- W(Gde-E-250) quality-B complete all as specified and directed. |
| 6 | S&F Mild steel hand rails, half round or other steel section or core for hand-rail straight portion. Drilled and countersunk for balusters, running bars, for doors, balusters nosing to steps including in concrete and screwing etc. wind ties for roof including securing bolts: posts and struts in fencing including cutting tops to shape as directed, drilling, holes notching for wire, etc: flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc, and similar work conforming to Fe-290 Gde E-165.complete all as specified and directed. |
| 7 | S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under \"Structural Steel\") complete all as specified and directed. |
| 8 | M&L for two coat of synthetic enamel painting on new steel surfaces over 10cms width or girthover and incld a coat of red oxide primer incld preparation of surface etc all as specified and directed. |
| 9 | Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 10 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, incl nainital or similar pattern roof covering.complete all as specified and directed. |
| 11 | S&F Pre-painted galvalume aluminium zinc coating 150 GSMGI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 12 | S&FPre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge,roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 13 | M&L Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3.complete all as specified and directed. |
| 14 | Dismantling of wall and ceiling boards (fibre, pulp, insulation. etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complte all as specified and directed. |
| 15 | Providing & fixing Anodised aluminium snap grid frame work for false ceiling Size of grid 605 x 605mm all as specified as per directions of the Engineer-in Charge. |
| 16 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. |
| 17 | M&L for exposed 8mm thick metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) complete all as specified and directed. |
| 18 | S&F plaster of paris Seamless calcium silicate ceiling 8mm thick made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish (Frame work for ceiling shall be measured and paid separately) complete all as specified and directed. |
| 19 | S& F Solid PVC Wall Lining Panellingconsisting of 5mm thick wood grain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed. |
| 20 | S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed. |
| 21 | Dismantling of brick tiles or terracing single layer on roof and removal of rubbish beyond MOD land complete all as specified and directed. |
| 22 | Demolition of mud phuska on roof slabs, any thickness including cleaning of roof surfaces and tarfelt and removing the debris outside the MOD landcomplete all as specified and directed. |
| 23 | Roughening surfaces of old concrete floors by picking, sweeping clean and washing down with waters to remove dusts etc. complete all as specified and directed. |
| 24 | M&L Brushing neat cement slurry with 3kg/sqm complete all as specified and directed. |
| 25 | M&L PCC 1:2:4 type B1 using 12.5 mm graded stone aggregate as in roof padding laid to required slope incl finishing the concrete surface fair and even without using extra cement complete all as specified and as directed. |
| 26 | M & L for 10 mm thick screed bed or bedding layer of mortar in cement mortar (1:4) for laying roof finish as padding finished with WPC 3% by weight of total cement, complete all as specified and directed NOTE :- Integral WPC shall be measured and paid separately. |
| 27 | Supply only integralwater proofing compound.complete all as specified and directed. |
| 28 | Material and Applying oil bound bitumen primer @ 0.40 Litre / Sqm manufactured by the same agency as that of APP with density of 0.87 to 0.89 Kg / Litre at 25 degree Celsius on the prepared dry roof surface.complete all as specified and directed. |
| 29 | M&L APP polymeric membrane min weighting 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric(wt not less than 150 gms/sqm laid on primed surfaces by torch application on method complete all as specified and directed. |
| 30 | M&L torching on joints (n exc 10cm) of old APP membrane sheet incl cleaning, brushing at joints and necessary repairs (incl suitable/items T&P/Gas cylinder) as required complete all as specified and directed. |
| 31 | Taking down cement/grit/roughcast plaster from stone/brick walls including racking out joints for keys and scrubbing down with water etc, complete all as specified and directed. |
| 32 | M&L for 15mm thick rendering of ready mix mortar of approved make on brick work or concrete surfaces on externalwalls, finish the surface even and smooth without using extra cement as whole or in patch etc complete all as specified and directed. |
| 33 | M&L for 10mm thick rendering of ready mix mortar of approved make on brick work or concrete surfaces on external wall/internal wall/ceiling, finish the surface even and smooth without using extra cement as whole or in patch etc complete all as specified and directed. |
| 34 | M&L for preparation of newly plastered surfaces of walls and applying two coat of oil bound distemper over and incld a coat of alkali primer (of approved quality and tint) on wall/celing including 1mm putty using painting roller, complete all as specified and directed. |
| 35 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 36 | Demolition of brick work or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings dressed stone work and Precast concrete articles,complete all as specified and directed. |
| 37 | M&L for Brick work with Sub class \"B\" old size burnt bricks straight or curved on plan exceeding 6m mean radius, built in Cement mortar 1:6 complete all as specified and directed. |
| 38 | Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner complete all as specified and directed. |