| 1 | Supply & Fixing and testing of LT cable 1100 volts grade, XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty)ISI Marked with aluminium conductor suitable for earthed system of size 300 sq mm 3.5 core in trenches, on poles and in ducts complete all as specified and directed by Engr in charge. |
| 2 | -- do-- all as per ser item no 1 above but size 150 sq mm 3½ core |
| 3 | -- do-- all as per ser item no 1 above but size 120 sq mm 3½ core |
| 4 | -- do-- all as per ser item no 1 above but size 95 sq mm 3½ core |
| 5 | -- do-- all as per ser item no 1 above but size 70 sq mm 3½ core |
| 6 | -- do-- all as per ser item no 1 abovebut size 50 sq mm 3½ core |
| 7 | -- do-- all as per ser item no 1 above but size 16 sq mm 4 core |
| 8 | -- do-- all as per ser item no 1 above but size 10 sq mm 4 core |
| 9 | -- do-- all as per ser item no 1 above but size 10 sq mm 2 coreNote for Sr No 01 to 09 : Excavation & Earthwork, Protection pipe etc shall be measured and paid seprately under relevent items of this Schedule. |
| 10 | Excavation in trenches nexc 1.5 mtr in depth and not exceeding 1.5 Mtr wide for laying of cable/pipe etc and getting out in any type of soil complete all as specified nad directed. |
| 11 | ditto all as per ser Item No.10 above but exceeding 1.5 mtr & not exceeding 3 mtr in depth. |
| 12 | Returning filling in trenches excavated soil including spreading levelling watering and well ramming in layers n.exc 25 cm thick each layer as in soil complete all as specified nad directed.. |
| 13 | Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified nad directed. |
| 14 | Supply & laying of HDPEDWC pipe ISI mark of outer dia 110 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable icluding coupler and bends etc complete all as specified and directed by Engineer-in-ChargeMake :Supreme / Infra / Astral/Prince/jain irrigation |
| 15 | Supply & laying of HDPE DWC pipe ISI mark of outer dia 63 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable icluding coupler and bends etc complete all as specified and directed by Engineer-in-ChargeMake :Supreme / Infra / Astral/Prince/jain irrigation |
| 16 | M&L for GI Tubes,of size 40mm dia Medium grade, galvanised, with all fitting, laid in trenchesfor protection of cable in road /drain crossing complete all as specified and as directed. |
| 17 | M&L for GI Tubes,of size 50mm dia Mediumgrade, galvanised, with all fitting , laid in trenchesfor protection of cable in road /drain crossing complete all as specified and as directed. |
| 18 | M&L for GI Tubes,of size 80mm dia Medium grade, galvanised, with all fitting, laid in trenchesfor protection of cable in road / drain crossing complete all as specified and as directed. |
| 19 | M&L for road cutting upto 300mm deep and 200mm wide for crossing GI pipe line through road including making good the disturbed surface by filling mass concrete( 1:2:4) etc complete all as specified and directed by Engineer-in-Charge.Note : Rate of mass concrete will be included in quoted rate. |
| 20 | Demolation of u/s cement concrete in coppings etc complete all as specified and directed by Engineer-in-Charge. |
| 21 | M & L for PCC(1:2:4) type C-2 using 20mm grade stone aggregatesfor copingand similar work including necessary formwork all as specified and directed. |
| 22 | M & L for PCC(1:3:6) type C-2 using 40mm grade stone aggregates as foundation of pole and similar work all as specified and directed. |
| 23 | S&F PVC Junction box of size 250x200x100mm, IP 66 with hinged door including locking arrangment and MCB SP 6 Amp with necessary nut,bolt etc and including TPN aluminium bus bar mounted on insulators with suitable holes to provide incoming and outgoing LT cables and street light MCB complete all as specified and directed |
| 24 | Supply and fixing wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, Three core cable in surface/recessed as required 2x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire (From PVC Junction box to Security light) |
| 25 | Supply, installation, testing and commissioining factory made LT feeder pillar panel CPRI approved, size of panel as per CPRI Specification,double door floor mounted outdoor type,as per IP-65 grade,made out of CRCA sheet 3.15 mm thick of outer body of suitable size with Aluminium bus bar 500 Amps,4 strip,(3 phase & Neutral) complete drilled,insulated with colour coaded insulation tape,mounted on insulators etc with RYB indicater,internal wiring with suitable size of copper wire,panel should be dust proof,vermin proof,powder coated,locking should be screw type,mechanical type,inter locking,should have danger noticefor 415 volt,AC,mounted on 50 x50 x6 mm angle iron frame having minimum 2 feet ground clearanceduly embedded in and including PCC block(1:2:4) type B1 foundation for fixing of panel complete including ternination of all incoming and outgoing cables with suitable size thimbles/lugs andstainless steel glands Nuts & Bolts complete all as specifid and directed.(Main Panel)Note: All MCCB Shall be Thermal and Magnetic adjustable type as per IEC 6047-II ( old exchange main panel)(i) Incoming MCCB 4P, 315 Amp, 36 KA,thermal and magnetic adjustable -01 No ( Ics = 100% Icu)(ii)Outgoing -Al bus bar 100 Amps(iii) Outgoing MCCB 4P 160 Amp, 36 KA -02Nos ( Ics = 100% Icu)(iii) Outgoing MCCB 4P 200 Amp, 36 KA -01Nos ( Ics = 100% Icu)(iv) Digital voltmeter & Ammeter with necessary CTs(v) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of approriate size but not less than 2.5 sqmm(vi) Phase indicating LED lamps (R-Y-B) -01 set |
| 26 | Supply, installation, testing and commissioining factory made LT feeder pillar panel CPRI approved, size of panel as per CPRI Specification,double door floor mounted outdoor type, as per IP-65 grade, made out of CRCA sheet 3.15 mm thick of outer body of suitable size with Aluminium bus bar 1000 Amps,4 strip, (3 phase & Neutral) complete drilled,insulated with colour coaded insulation tape,mounted on insulators etc with RYB indicater,internal wiring with suitable size of copper wire, panel should be dust proof,vermin proof,powder coated,locking should be screw type,mechanical type,inter locking,should have danger noticefor 415 volt,AC,mounted on 50 x50 x6 mm angle iron frame having minimum 2 feet ground clearanceduly embedded in and including PCC block(1:2:4) type B1 foundation for fixing of panel complete including ternination of all incoming and outgoing cables with suitable size thimbles/lugs andstainless steel glands Nuts & Bolts complete all as specifid and directed.(Main Panel)Note: All MCCB Shall be Thermal and Magnetic adjustable type as per IEC 6047-II ( old exchange main panel)(i) Incoming MCCB 4P, 630 Amp, 50 KA,thermal and magnetic adjustable -01 No ( Ics = 100% Icu) (ii)Outgoing -Al bus bar 100 Amps (iii) Outgoing MCCB 4P 315 Amp, 36 KA -02Nos ( Ics = 100% Icu) (iii) Outgoing MCCB 4P 200 Amp, 36 KA -02Nos ( Ics = 100% Icu) (iv) Digital voltmeter & Ammeter with necessary CTs(v) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of approriate size but not less than 2.5 sqmm(vi) Phase indicating LED lamps (R-Y-B) -01 set(vii) Spare chamber for MCCBs - 01 Nos |
| 27 | M & L for fabrication of bus bar chamberof sizenot less than 600 x 600 x450 mm suitable for415 volts 3 phase 4 wire system , outdoor type, double door, with pedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti corrosive coating & finally epoxy polyster powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion ofsuitable cable glands for all incoming and out going cable including grouting of panel board60 cm above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge Incoming MCCB : 200 AMps ,4P,25 KA Busbar Capacity : 300 AMpsmounted on DMC/ porcelain insulator support with RYB indicatorOutgoing : one MCB/MCCB mounted chanel slotted500 mm long |
| 28 | M & L for fabrication of bus bar chamberof sizenot less than 600 x 600 x450 mm suitable for415 volts 3 phase 4 wire system , outdoor type, double door, with pedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti corrosive coating & finally epoxy polyster powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion ofsuitable cable glands for all incoming and out going cable including grouting of panel board60 cm above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge Incoming MCCB : 160 AMps ,4P,16 KA Busbar Capacity : 200 AMpsmounted on DMC/ porcelain insulator support with RYB indicator |
| 29 | Notes:- For Item No 24 to 291. The PanelShould be approved by CPRI.2. The rates Quoted shall include for excavatio & earth work, Plinth protection around the panel apprx 75cm and excavation & earthwork for angle iron frame for foundation of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 filling in foundation. The ground clearance of panel board shall be 0.40 M from GL to the bottom of panel board. |
| 30 | M&L for earthing complete with galvanized steel earth plate electrode of size 60cm X 60 cm X 6 mm buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5 m below the normal ground level connected to GI earth strip 32 X 6 mmas earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, protected by GI pipe light grade 40mm bore all as shown on electrical plate No 3 of SSR Part-I connected to earth test point electrode, PCC pit with RCC cover, funnel with wire mesh, watering pipe 20mm dia protection pipe etc and testing on completion complete all as specified and directed.Note No 1 :-The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B-1 cover 50 mm thick reinforced with 8 mm dia TMT bar @ 150 mm c/c both ways, funnel with watering pipe 20 mm dia medium grade, GI protection pipe light grade 40 mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (Notes) under sub-heading earthing, specified on SerialPage No 389 of SSR Part –I.Note No 2 :-Earthing strip and GI protection pipe beyond 7.5 m will be measured and paid separately if required(iii)PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself. |
| 31 | Supply and fix in replacement New generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07, with luminaries 100 watt, with inbuilt surge protection 10 KV including 50 mm dia size ofGI Bracket of length 1.2 Mtr, with Clamp, Nut, Bolt and washer, connection with 1.5 sqmm 3 runcopper wire from junction box to streeght light and4 sqmm 2 core aluminium servicecable pvc insulated 2.5 RM per fitting where over head line existingforconnection of street light to over head conductor complete all as specifiedand directed. Make : Havells cat part no ENDURAOMNIPLUSSL120WLED757SASYTOPC or equivalent as approved by GE. |
| 32 | M&L for earthing complete with galvanized steel earth plate electrode of size 60cm X 60 cm X 6 mm buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5 m below the normal ground level connected to GI earth strip 25 x4mmas earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, protected by GI pipe light grade 40mm bore all as shown on electrical plate No 3 of SSR Part-I connected to earth test point electrode, PCC pit with RCC cover, funnel with wire mesh, watering pipe 20mm dia protection pipe etc and testing on completion complete all as specified and directed.Note No 1 :-The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B-1 cover 50 mm thick reinforced with 8 mm dia TMT bar @ 150 mm c/c both ways, funnel with watering pipe 20 mm dia medium grade, GI protection pipe light grade 40 mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (Notes) under sub-heading earthing, specified on SerialPage No 389 of SSR Part –I.Note No 2 :-Earthing strip and GI protection pipe beyond 7.5 m will be measured and paid separately if required(iii)PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself. |
| 33 | Dismantling carefully the existingLT overhead line ACSR conductor with cross arm ofany size from its position by necessary disconnecting of conductor and removing complete all as specified and as directed |
| 34 | Dismantling stay assembly complete all as specified and directed |
| 35 | Dismantling of unserviceable existing cross arms made from channels, angles and unserviceable FI clamps, nuts, bolts etc from OH line and removing complete all as specified and as directed |
| 36 | S &F PCC Cable route Indicator with suitable reinforcement ofsize 50 x 10 x 10 cm with letter inscribed on both side as \"MES LTCABLE \" of specified front side not less than 30 mm as directed andcomplete using PCC 1: 2:4 B1 using 20 mm graded stone aggregate and including painting using cement based paint to thesatisfaction of engr in charge |
| 37 | Supply, erecting and fixing in replacement of true vertical position of steel tubular swaged pole, 9 mtr long complete with cast iron base plate, finial taper plug, bolt, nuts and screws as specified and of type 410 SP-31, conforming to relevant IS, including one primer coat of d oxide and two coats of aluminium paint and two coats of bituminous paint inside and outside of botton portion including writing of pole nos (Yellow circle and Number in black) and providing 3 Nos of radium with width 50 mm size band / strap with Red, Yellow, Green colour 300 mm apart from plinth block around the pole etc complete as all as specified and directed in Engr-in- Charge. |
| 38 | M & L for painting of Street light poles of any type (with hydrolic vehicle / ladder) including cross arms, channel, flat iron clamps etc 9/11 mtr longin two coats of aluminium paint and one coat of red oxide as primer including writing of pole nos (Yellow circle and Number in black) and providing 3 Nos of radium with width 50 mm size band / strap with Red, Yellow, Green colour 300 mm apart from plinth block around the pole etc complete as all as specified and directed in Engr-in- Charge.Note:- Hydrolic Vehicle / Ladder for painting is responsibility of contractor and rate of Hydrolic vehicle and ladder deemed to be included in quoted rate. |
| 39 | M & L forpainting of coping ofpoleincluding preparation of surface and one coat of primer and two coat of Apex (off white colour) complete all as specified and directed by engr in charge |
| 40 | Supply and fix of 40 Amp time light DB with TP 40 amps mcbat incomer with 40 Amp AC3 duty contractor along with design as per IEC 61439, material and CRCA sheet up to 1.2 mm with Asrtonomical time switch complete prewired IP 55 protection auto manual selector switch for auto manual selector switch for auto manual operation,power indicator and 2 Amp fuse for protection of time switch,input output terminal block of termination of input output cable with gland special provision of incorporation of under voltage over voltage relay for protection of incarporated contractor coil,including the cost of labour charges for erectingon pole /walls/panel including clamps,nut bolts to complete the job up to the entire satisfaction of Engr in charge of work .Make : Indoasian cat ref no TL040ASO and equivalent |