| 1 | Note :- (i) Work to be carried out on GL to 8th floor (incluing terrace of building) from ground level. (ii) Rate for Scaffolding and Safety System for labour are included in quoted raes by Contractor. (iii) Safety Net and Water Proofing covering materials shall be arrange by Contractor while working at Site and it will be deem fit in quoted rats by Contractor.Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of size n.exc 1.50 Sqm complete all as specified and directed. |
| 2 | Taking down chowkats with shutters (without taking off shutters from frames) area of openingexc 1.5 Sqm but n.exc 4 sqmeach complete all as specified and directed. |
| 3 | Dismantling wall & ceiling boards (fibre, insulation etc.) or insulation boards, slabs, blankets any thickness including cover fillets complete all as specified and directed. |
| 4 | Demolition of cement concrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed. |
| 5 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 6 | S&F 605mm x 605mm GI frame work for seamlesscelling snap grid frame work for false ceilling with all necessary angle & Tee arrangement with and incl fixing cleats screw etc complete all as specified and directed. |
| 7 | S&F hanger 6mm dia GI (upto 1200mm length) adjusting level fixed to roof by means of celling complete all as specified and directed. |
| 8 | S&F False celling 8mm thick(Non asbestos fibre cement building board) fixed in celling flat or sloping inserted inGI/aluminium frame work complete all as specified and directed. (Make-Armstrong,saint Gobain) |
| 9 | Dismantling wrought iron or mild steel work of any description not otherwise described complete all as specified and directed. |
| 10 | Demolition of brick/Stone masonary work built in Cement Mortar including in all quoins etc and precast concrete articles complete all as specified and directed. |
| 11 | S&F for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed. |
| 12 | M&L for fly ashBrickwork with subclass ‘B’ bricks, old size bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete as specified as directed. |
| 13 | M&L 15mm thick rendering in cement mortar (1:6) onbrick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 14 | M&L preparation of new plastered surfaces and applying two coats oil bound distemper over a coat ofalkaline resistent primer over and includinga coat of 3mm thick wall care putty to the surface complete all as specified and as directed |
| 15 | M&L preparation of old plastered surfaces by complete removal of existing treatment and applying two coats oil bound distemper over a coat ofalkaline resistent primersurface, complete all as specified and directed. |
| 16 | S&F Pressed Steel frames of size 105x60mm for doors with one or more rebates including filling of pressed steel frame, holdfast with PCC 1:3:6 type C1 (using 20mm graded aggregate stone aggregate) necessary fixing lugs, hinges, lock strike, plate etc complete all as specified and directed by Engr-in-Charge |
| 17 | S&F for Steel door including projecion type hinges, steel handle, complete with glazing bars, dovetailed or welded complete all as specified and as directed. |
| 18 | S&F for Steel windows or ventilators, fixed type, with glazing bars complete all as specified and as directed. |
| 19 | M&L for cement concrete type B0 1:2:4 (using 12.5mm graded aggregate) as in hold fast blocks including filling of pressed steel frame, coping, plinth course complete all as specified and as directed. |
| 20 | S&F for Roof trusses (framed), trussed purlins, ctane gantries, rails & fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of grade Fe 410-W (GdeE-250) quality-A complete all as specified and directed. |
| 21 | S&F of Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thickof any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 22 | S&F Pre-painted galvalume aluminum zinc coated GI based plain steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridge etc fixed with self tapping screwscomplete all as specified and directed. |
| 23 | M&L for Preparation of newly steel surface of any description over 10cm width or girth and applyin two coat of synthetic enamel paint over one coat of red oxide complete all as specified and directed. |
| 24 | M&L for Machine pressed precast concrete interlocking paver block any shape and size with gray cement no pigment conformed to IS 15658-2006 of 60 mm thickness M-35 grade complete all as specified and directed. |
| 25 | M&L for sand cushion filling for floor, foundation etc including watering and consolidation complete all as specified and directed. |
| 26 | M&L PCC (1:2:4) type B-1 using 20mm graded stone agregete as in sides of rounded or chamfered on edges of interlocking tilescomplete all as specified and directed. |
| 27 | M&L for Hardcore of broken stones or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 28 | M&L for PCC 100mm thick type D-2 1:4:8 (40mm graded agregade) as in sub base complete all as specified and directed. |
| 29 | M&L for 100mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) finishing smooth & even with using extra cement complete all as specified and directed. |
| 30 | M&L for Preparing newly plastered surfaces of wall and applying two coats of acrylic base exterior grade (100% Acrylic) over a coat of primer complete all as specified and as directed. |
| 31 | M&L for point wiring with ISI marked 1.5 sqmm PVC insulated, unsheathed, single core, multistranded copper conductor cable 1100 volts grade FRLS type drawn through and incl stove enamelled steel conduit of 25mm dia with all accessories incl PVC insulated, unsheathed, single core, multistranded copper conductor and shall be connected to common earth dolly complete from MCB DBall as specified and directed for one light point controlled by one switch. |
| 32 | All as per item No 1 above but with 2.5 sqmm controlled by flame proof switch socket and plug 16 amps. |
| 33 | S&F Switch flame proof rotary type with termination box in LM6, 6 Amp, single pole 250 volts, all as specified and directed. |
| 34 | S&F flame proof-weather proof switch socket and plug combined 16 Amp , 250 Volts (2P+Earth), allas specified and directed. |
| 35 | Supply and Fixing of Flameproof cum Waterproof LED Bulk Head light fitting of 30 W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen \"A\" clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size. |
| 36 | Supply, installing, testing and commissioning fire extinguisher dry chemical powder (ABC) type 6 Kg capacity ( IS 15683) with stand complete all as specified and directed. |
| 37 | Supply, installing, testing and commissioning fire extinguisher CO2 type 4.5 Kg capacity ( IS 15683) completewith standall as specified and directed. |
| 38 | Supply, installing, testing and commissioning fire extinguisher Mechanical foam type 9 Ltr capacity ( IS 15683) with stand complete all as specified and directed.Make for Item Nos 1, 2 & 3:MINIMAX, SAFEX, VIJAY, SAFEZONE, CEASE FIRE, MONARC ENGINEERINGS |
| 39 | Note : (a) Quoted rate shall be inclusive of material, all kind of labours, tools and plants scalfolding and working upto 25 mtrs height from ground level, (b)Adoptation of necessary safety arrangements like safety belts ropes, hel,ets, safety net, etc. which are required for safety of working at feight 25 mtrs ans all rates shall be mandatary and deemed to be inclusive on quoted rates.M&L taking down cement plaster on bricks or stone walls etc. including raking out joints, hacking for key, scrubing down with water, Rendering 10mm thick in cement mortar 1:4 complete all as specified etc. |
| 40 | M&L medium density company fitted decorative laminated on both side fiber board (HDMMR) 25mm thick, exterior grade for partition, plateform, completed all as specified and directed (Make-Action, tea, Century, mamiano) |
| 41 | M&F Mild steel wood screws brightfnished with slotted countersunkhead designation 12 to 14 (5.59 to 6.30mm nomial shank dia) exc 50 mm long |
| 42 | S&F framed brackets of angles or tees with web and flanes cut to shape, drilling and countersunk for screw including bending and welding angles as necessary guest plates riveting etcn exc 10kg each brackets conforming to Fe 290. Gde-E-165 (Brackets over 10 Kg each to be measured under Structural Steel |
| 43 | S&F continuous (piano) hings, mild steel bright finish or electrogalvanished(30mm) all as specified and directed By E-I-C |
| 44 | S&F aluminium handles, cast type, anodised all as specified and directed by E-I-C |
| 45 | S&F framed work as in doors or gates of angles or other section with gusset plates, rails, braces, etc (Fe 290 Gde, E-165) complete, drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with an including either hooks and hingers or steel hangiring door fitings (exclusive of steel sheeting or other covering running rails and guides) and hanging also fastening and fixing complete |
| 46 | S&F Ball catches with 8 mm dia steel ball and brass body and striking plate including letting in and fixed all as specified directed by E-I-C |
| 47 | S&F 09097 Mortice lock verticial type, size 25mm all as specified and directed by E-I-C |