| 1 | LT Panel - Design, manufacture, supply, installation, testing and commissioning of LT PCC panel at North Site as per TSS01 of tender specifications. |
| 2 | PCC-1 in AC Plant Room at Purnima. |
| 3 | PCC-2 (MP-1)in HPPD Bldg. |
| 4 | Outdoor Feeder Pillar Panels. |
| 5 | PCC-5 at HIRUP Bldg. |
| 6 | PCC-6 at CED Bldg. |
| 7 | PCC-7 at Society R-5 shed. |
| 8 | LT Panel - Design, manufacture, supply, installation, testing and commissioning of LT PCC panel at South Site as per TSS01 of tender specifications. |
| 9 | PCC-8 at S-70 Shed. |
| 10 | PCC-9 at S-63 Shed. |
| 11 | PCC-10 ( MP1.0) at UCUF Bldg. |
| 12 | PCC-11 (MP1.1)in Assembly Area at UCUF Bldg. |
| 13 | PCC-12(MP1.2)in Experimental Area at UCUF Bldg. |
| 14 | PCC-13 (MP1.3) in Simulation Area at UCUF Bldg. |
| 15 | LT power cable - Supply, installation, testing and commissioning of following 1.1 KV,Al conductor, XLPE insulated, PVC sheathedFRLS cables as per TSS03 of tender specifications. |
| 16 | 3.5C x 400 sq. mm Al conductor cable (Underground laying). |
| 17 | 3.5C x 300 sq. mm Al conductor cable (Underground laying). |
| 18 | 3.5C x 185 sq. mm Alconductor cable (Underground laying) |
| 19 | 3.5C x 70 sq. mm Alconductor cable (Surface laying). |
| 20 | End termination of cables -End termination of following copper/Al conductor, XLPE insulated, PVC sheathed cables with copper lugs, single compression type brass glands, earthing etc as per TSS04tender specifications. |
| 21 | 3.5C x 400 sq. mm Al conductor cable. |
| 22 | 3.5C x 300 sq. mm Al conductor cable. |
| 23 | 3.5C x 240 sq. mm Al conductor cable. |
| 24 | 3.5C x 185 sq. mm Al conductor cable. |
| 25 | 3.5C x 120 sq. mm Al conductor cable. |
| 26 | 3.5C x 95 sq. mm Al conductor cable. |
| 27 | 3.5C x 70 sq. mm Al conductor cable. |
| 28 | 3.5C x 50 sq. mm Al conductor cable. |
| 29 | 4C x 25 sq. mm Al conductor cable. |
| 30 | End termination of others power cables - End termination of following copper/Al conductor, XLPE insulated, PVC sheathed cables with copper lugs, single compression type brass glands, earthing etc as per TSS05tender specifications. |
| 31 | 3.5C x 500 and above sq. mm Al conductor cable |
| 32 | 4C x 10 sq. mm copper conductor cable |
| 33 | G I Cable trays - Supply and installation ofperforated cable tray of following sizes with cover as per TSS06tender specifications. |
| 34 | 150 mm x 75 mm Sizeperforated type. |
| 35 | 300 mm x 100 mm Sizeperforated type. |
| 36 | Cable marker - Supply and installation of oval shaped GI cable marker as per TSS07 of tender specifications. |
| 37 | M S Box - Supply & installation of MS boxes fabricated out of MS sheets as per TSS08 of tender specification. |
| 38 | M S item - Supply & installation of MS items fabricated out of MS angles/channels as per TSS09 of tender specification. |
| 39 | Earthing stations - Supply, installation, testing and commissioning of earthing station consisting of 600 x 600 x 3.15 mm thick tinned copper earth plate, GI pipe, funnel, masonary chamber etcas per tender TSS10of tender specifications. |
| 40 | Earthing Conductor - Supply and installation ofbare copper earth strip/wire of following sizes to be installed in trenches, under ground, wall, RCC, slab, above false ceiling, trenches etc. as per TSS11 of tender specifications. |
| 41 | 50x5 mm copperstrip. |
| 42 | 25x3 mm copperstrip. |
| 43 | 8 SWGsize Copper wire. |
| 44 | Removalof cables - Removal of cables of following sizes from cables tray, trenches, walls etc.as perTSS12 of tender specifications. |
| 45 | Removal of cable 4Cx10/16/25 sq.mm |
| 46 | Removal of cable 3.5Cx35/50 /70 sq.mm |
| 47 | Removal of cable 3.5Cx95/120/150 sq.mm |
| 48 | Removal of cable 3.5Cx185/240 sq.mm |
| 49 | Removal of cable 3.5Cx300/400 sq.mm |
| 50 | Removal, Dismantling and shifting of PCC Panels and other equipmentsas per TSS 13 of tender specifications |
| 51 | MCCB box/ SFU/ DBs/control panels etc |
| 52 | Old PCC LT Panels upto 10 feeders |
| 53 | Old PCC LT Panels upto 20 feeders |
| 54 | Outdoor Feeder Pillar Panels(2 m x 2 m x 0.75 m size). |
| 55 | Installation, testing and commissioning of cables - Installation, testing and commissioning of cables of following sizes from cables tray, trenches, walletcas perTSS14 of tender specifications. |
| 56 | Only installation of cable 4Cx10/16/25 sq.mm. |
| 57 | Only installation of cable 3.5Cx35/50/70 sq.mm. |
| 58 | Only installation of cable 3.5C x 95/120/150 sq.mm. |
| 59 | Only installation of cable 3.5Cx185/240 sq.mm. |
| 60 | Only installation of cable3.5Cx300/400 sq.mm. |
| 61 | Installation of metering box and other equipments - Installation of metering box and other equipments as perTSS15 of tender specifications. |
| 62 | Excavationas per as perTSS14 of tender specifications. |
| 63 | Soft soil/Murum |
| 64 | Hard rock/PCC |
| 65 | Plain cement concrete (PCC) - Casting of plain cement concrete (PCC 1:2:4) with supply of cement, metal, sand etc as reqd at site and as directed by EICas perTSS15 oftender specifications. Necessary frame and shuttering required is to be arranged by the contractor. |
| 66 | RCC Hume pipe - Supply and installation of 150mm dia. size RCC Hume Pipe to be laid in groundas per TSS16 oftender specifications. |
| 67 | Electric Mat - SITC of Insulating mat as per TSS17 of tender specifications. |
| 68 | Distribution Boards - Supply, installation, testing and commissioning of 8 way VTPN DBas per tender specification. |