| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.(Additional area of TRAI) a)Group C |
| 2 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.a)1 run of cable |
| 3 | b)2 run of cable |
| 4 | c)3 run of cable |
| 5 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a)3 x 1.5 sq. mm |
| 6 | b) 6 x1.5 Sqmm |
| 7 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (for lights, UPS) |
| 8 | b)4 x 1.5 sq. mm + 2 x1.5 sq. mm earth wire |
| 9 | c)2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 10 | d)4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire |
| 11 | Supplying and fixing of RJ45 female socket (LAN socket) i/c providing surface PVC box, face plate, interconnections, testing etc., as required. |
| 12 | Supplying and fixing following size/ modules, PVC box along with modular base & cover plate for modular switches in recess etc. as required.a) 12 Module |
| 13 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a)5/6 amps switch |
| 14 | b)3 pin 5/6 amp socket outlet |
| 15 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, inclduing providing and fixing 6 pin 5/6A & 15/16A modular socket outlet and 15/16A modular switch, connections etc.,as reqd |
| 16 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm |
| 17 | b)25 mm |
| 18 | Installation, testing and commissioning of pre-wired, LED light fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit up to 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 19 | Removing and re-fixing of existing ceiling fan including wiring the down rods of standard length (up to 30 cm) with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable including providing and fixing offan hook etc., as required. |
| 20 | Repairing & rewinding ofceiling fan including replacing of fan bearings, fan capacitor and general servicing, i/c Transporting to work shop and again bring back to O/o TRAI, re-fixing, testingetc., as required. |
| 21 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |