| 1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 2 | a) 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | b) 1:5:10 (1 cement : 5 fine sand derived from natural sources : 10 graded brick aggregate 40 mm nominal size derived from natural sources) |
| 4 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 5 | a) Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 6 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 7 | a) Cement mortar 1:3 (1 cement :3 coarse sand) |
| 8 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 9 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 10 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. |
| 11 | a) 12 mm cement plaster |
| 12 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 13 | a) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 14 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 15 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 16 | a) Two or more coats on old work. |
| 17 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with \"S\" or \"P\" trap including dismantling of old WC seat and \"S\" or \"P\" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. |
| 18 | a) Orissa pattern W.C Pan of size 580x440 mm |
| 19 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : |
| 20 | a) W.C. pan with ISI marked white solid plastic seat and lid |
| 21 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 22 | a) 10 litre capacity - White |
| 23 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 24 | Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer in-charge |
| 25 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 26 | a) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 27 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 28 | a) For thickness of tiles 10 mm to 25 mm |
| 29 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : |
| 30 | a) 75 to 80 mm dia pipe. |
| 31 | b) 100 mm dia pipe |
| 32 | Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. |
| 34 | a) 20 mm nominal outer dia .Pipes. |
| 35 | b) 25 mm nominal outer dia .Pipes. |
| 36 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 37 | a) 45 cm length |
| 38 | i) 15 mm nominal bore |
| 39 | Providing and fixing PTMT bib cock of approved quality and colour. |
| 40 | a) 15mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 41 | Providing and fixing PTMT stop cock of approved quality and colour. |
| 42 | a) 15 mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 43 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 44 | a) One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 45 | Providing and laying water proofing treatment in sunken portion of WCs, with slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm |
| 46 | Providing and fixing on uPVCwaste water sewer pipes, including jointing with seal ring of approved make, |
| 47 | i) 75 mm diameter |
| 48 | ii) 110 mm diameter |
| 49 | Providing and fixing uPVC moulded fittings/accessories for uPVC waste water pipes |
| 50 | a) Single tee with door |
| 51 | i) 75x75x75 mm |
| 52 | ii) 110x110x110 mm |
| 53 | b) Bend 87.5° |
| 54 | i) 75 mm bend |
| 55 | ii) 110 mm bend |
| 56 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 57 | Providing and fixing FTA/MTA for cpvc pipeline |
| 58 | a) 20 mm nominal bore. |
| 59 | Providing unskilled labour for miscellaneous works not covered in schedule items |
| 60 | Providing manual assistance for plumbing sewer, masonry & carpentry work which are not covered above and are not possibleto measure. |
| 61 | Providing and fixing 100 mm dia CP Jaalias per direction of Engineer-In- Charge. |
| 62 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 63 | Providing and fixing PVC trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : |
| 64 | a) 100 mm inlet and 75 mm outlet |
| 65 | Cutting of mosaic/CC flooring by hammer machine in Toilet blocks i/c cost of Labour, machine etc all complete as per direction of E-in-C |
| 66 | P/F CPVC gate valve25 mm nminal borein water supply line |
| 67 | Tracing out leakage in Toilet block at First Floor and S.F. ,in duct portion and its removalwith help of required scaffolding arrangement ,safety precautions etc all complete as per direction of Engineer in charge. |