| 1 | Material and labour for Disconnecting the existing 100/80 mm GI/DI/CI pipe, suction and delivery of any type from supply line and fixing with new pipes given in schedule. The cost shall be included all fittings such as elbow, bend,union, socket, nipple fusion joint, nominal dia 80/100 mm as per IS 3589 (1981) thickness 6.0mm, joints complete for delivery end side including necessary nuts, bolts, reducer,tee,joints,union, welding works and rubber etc all as specified and directed. |
| 2 | Material and labour for Disconnecting the existing 200/150 mm GI/DI/CI pipe, suction and delivery of any type from supply line and fixing with new pipes given in schedule. The cost shall be included all fittings such as elbow, bend,union, socket, niple fusion joint, nominal dia 200/150 mm as per IS 3589 (1981) thickness 6.0mm, joints complete for delivery end side including necessary nuts, bolts, reducer,tee,joints,union, welding works and rubber etc all as specified and directed. |
| 3 | Material and labour for Disconnecting the existing 40/50 mm GI/DI/CI pipe, suction and delivery of any type from supply line and fixing with new pipes given in schedule. The cost shall be included all fittings such as elbow, bend,union, socket, nipple fusion joint, nominal dia 40/50 mm as per IS 3589 (1981) thickness 6.0mm, joints complete for delivery end side including necessary nuts, bolts, reducer,tee,joints,union, welding works and rubber etc all as specified and directed. |
| 4 | S&F for 150 mm bore ductile iron pipes with spigot and socket joint, centrifugally cast,inside surfaces with cement mortar lining,ISI marked, Class K7, in any length, laid in trenches/ on ground/ on supports with push on rubber gasket jointsof any description and type and making good disturbed surfaces all as specified and directed.Note: Ductile iron pipe fittings wherever required shall be measured and paid separately under relevant items of this Schedule. (For Near OHT Mandir to 200 SQN and 3001) |
| 5 | M & L for GI water tubing 80 mm bore medium grade ISI marked with all required fittings such as bends elbows, tees short pieces, connector check nuts & threading laid in trenches complete all as specified & directed. (Excavation shall be measured and paid seperately) Make : Jindal/TATA/Surya |
| 6 | All as per Srl No. 05 above here-in-before but of size 50 mm |
| 7 | All as per Srl No. 05 above here-in-before but of size 25 mm |
| 8 | All as per Srl No. 05 above here-in-before but of size 20 mm |
| 9 | All as per Srl No. 05 above here-in-before but of size 15 mm |
| 10 | Supply and fix in repair NRV (Non return valve) of size 150 mm bore type flanged and drilled ends complete, ISI marked, including jointing material such as rubber gasket, bolts, nuts, etc suitable for size 80mm all as specified and as directed by Eng-in-Charge Make: Kirloskar/ZOLOTO/L&T or Venus |
| 11 | Supply and fix in repair of sluice valve of size 150 mm dia PN 1.6 type flanged and drilled ends complete ,ISI marked, including jointing material such as rubber gasket, bolts, nuts, etc suitable for size 150 mm all as specified and as directed by Eng-in-charge Make: Kirloskar/ZOLOTO/L&T or Venus |
| 12 | Supply and fix in repair of NRV (non return valve of size 80mm bore type flanged and drilled ends complete, ISI marked, including jointing material such as rubber gasket, bolts, nuts, etc suitable for size 80 mm all as specified and as directed by Eng-in-Charge Make: Kirloskar/ZOLOTO/L&T or Venus |
| 13 | Supply and fixin repair of sluice valve, 80 mm PN 1.6 type flanged and drilled ends complete ,ISI marked, including jointing material such as rubber gasket, bolts, nuts, etc suitable for size 80 mm all as specified and as directed by Eng-in-charge. Make: Kirloskar/ZOLOTO/L&T or Venus |
| 14 | Supply and fixin repair of sluice valve, 50 mm PN 1.6 type flanged and drilled ends complete ,ISI marked, including jointing material such as rubber gasket, bolts, nuts, etc suitable for size 50 mm all as specified and as directed by Eng-in-charge. Make: Kirloskar/ZOLOTO/L&T or Venus |
| 15 | Supply and fixin repair of Gun-metal, globe or gate valves 25 mm dia with iron wheel head, screwed both ends for iron pipe and supply fixed new one all as specified and as directed. Make: Zoloto, Leader, GEM. |
| 16 | Supply and fixin repair of Gun-metal, globe or gate valves 20mm dia with iron wheel head, screwed both ends for iron pipe and supply fixed new one all as specified and as directed. Make: Zoloto, Leader, GEM. |
| 17 | Supply and fixin repair of bib tap, cast copper alloy chromium coated, screwed down, screwed for iron pipe or for brass ferrule and fixed size 15mm bore dia of pipe complete all as directed Make: Jaquar/Prayaag/Cello |
| 18 | S&F in repair of 80 mm bore Air release valve cast iron body,as per existing model/ type, conforming to relevant IS marked with rubber gaskets, MS nuts, bolts, washers, etc., as required and testing complete including taking down the existing unserviceablefoot valve of any description all as specified and as directed. Make: L&T/ Zoloto/ Kirloskar |
| 19 | M&L for brick masonary valve pit (type B) of size 1.2 x1.2x 1.2 mtr (internal of chember ) depth of chember to be reckoned from the top of PCC in foundation to top the MS cover as 1.5 mtr and including MS sheet cover fabricated from 3 mm thick MS sheet and frame of angle iron 40 mm x 40 mm 6 mm with fixing arrangement , hinges and locking arrangement and painting two coat of synethetic enamel paint over a coat of red oxide primer on MS cover and frame , inlcuding necessary excavation and earth work in any type of soil , returning , filling in approved soil disposal of surplus soil to a distance not exc.50 mtr , 150 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation , brick work in cement motor (1:6) 15 mm thick plastering in cement mortoar (1:4) (both internally and externally) 100 mm thick PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in flooring complete all as directed. |
| 20 | Taking up or down U/S GI tubing and connection 20mm size |
| 21 | Taking up or down U/S GI tubing and connection 25mm size |
| 22 | Taking up or down U/S GI tubing and connection 15mm size |
| 23 | Taking up or down U/S GI tubing and connection 50mm size |
| 24 | Taking up or down U/S GI tubing and connection 80mm size |
| 25 | Taking up or down U/S GI/DI/CI tubing/pvc and connection 150mm size |
| 26 | Material and labour for PCC 1:3:6, type C-1, using 20mm graded stone aggregate under pipe line as anchor blocks at the places where required and fair finishing to exposed surfaces without using extra cement including necessary form work or excavation, if required complete all as specified. |
| 27 | Supply and laying reinforced concrete pipe, class NP2 laid and jointed complete with collars size of pipe 250 mm dia all specified and as directed. Note: Excavation, returning filling in and removal of excavated material from site shall deemed to be included in the quoted rate. |
| 28 | S&F cast iron/DI fittings, like bends, tee, tail pieces collars etc, spigot socketed and flanged ends type etc confirming IS upto 150 mm bore pipes all as specified and as directed. |
| 29 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 200 mm dia suitable for 0.4 mpa working pressure. |
| 30 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying of CI/DI/GI steel water tubes etc, and getting out in any type of soil all as specified and directed. |
| 31 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cmall as specified and directed. |
| 32 | Removing excavated materrial/ surplus soil not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point. |
| 33 | Supply and install hi wall split units indoor/ outdoor complete with cordless remote control unit and with in built Heating and Cooling arrangement and Digital Inverter twin rotary type,3 Star rating of 1.5 TR capacitywithpowder coated MS bracketfor mounting of outdoor unit complete including taking down the existing AC any type, make and make good brick wall after taking down AC to match it with existing wall completeand deposit the Old ACin Ref Section of AGE (E/M) of GE AF Bhisiana complete all as sepcified and directed by the Engr-in charge. Make :- Llyod/Hitachi/Voltas |
| 34 | Material and Labour for sub main wiring with 2 runs of 4 Sqmm single core PVC insulated unsheathed FRLS cable 1100 Volts grade multistranded with copper conductor drawn through and including non metallic rigid PVC conduit ISI marked 25 mm dia including conduit accessories concealed/surface type on walls, roof,floors etc including one run of 4.0 Sqmm PVC copper conductor as earth continuity wire includingtaking downunserviceable sub main wiring including conduit from MCB SPN to AC box all as specified and directed. Note : 2 Runs of 4 sqmm cable 1 run of 4 sqmm cable and 1 run of PVC conduit shall be measured as one unit for the purpose of payment. |
| 35 | S&F in repairs metallic AC earth plug and socket with sheet metal enclosure with MCB SP 20Ato 32 A complete all as directed by Engr in charge. |
| 36 | Material and labour for point wiring complete with ISI marked1.5 SqmmPVC insulated multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc,concealed/surface type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etcincluding PVC gang boxes as required at site for concealed/surface conduit wiring and modular plates & covers as required at site for housing switches sockets, regulators etc. including providing of 1.5 Sqmm PVC insulated multistranded unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for and connecting up complete for Switch Socket outlet 2/3 pins 6 Ampson independent board |
| 37 | S&F in repairs switch socket outlet 3 pin,5 Amps 240 Volt complete all as directed.Make: cona/anchor/GM |
| 38 | Supply, installation, commis-sioning of Water cooler fully stainless steel, electric driven single phase having 150 Ltrs storage capacity and 150 ltrs per hr nominal cooling capacity complete including taking down the existing water cooler any type and make and deposit the same in Ref Section of AGE (E/M) of GE AF Bhisiana complete all as sepcified and directed by the Engr-in charge. |
| 39 | Supply, installation, commis-sioning of Water cooler fully stainless steel, electric driven single phase having 40 Ltrs storage capacity and 40 ltrs per hr nominal cooling capacity complete including taking down the existing water cooler any type and make and deposit the same in Ref Section of AGE (E/M) of GE AF Bhisiana complete all as sepcified and directed by the Engr-in charge |
| 40 | Supply, installation, commis-sioning of Water cooler fully stainless steel, electric driven single phase having 80 Ltrs storage capacity and 80 ltrs per hr nominal cooling capacity complete including taking down the existing water cooler any type and make and deposit the same in Ref Section of AGE (E/M) of GE AF Bhisiana complate all as sepcified and directed by the Engr-in charge |
| 41 | M&L forPVC connections 15mm size with PTMT of length 300mm from existing water pipe to water cooler inlet all as specified and directed. |
| 42 | Supply and fix voltage stabilizer for Automatic operation with digital display for IP & OP voltage, copper wound, single phase natually air cooled indoor type & designed for input variation between 130V to 270V with output valtage stabilized at 230V with accuracy if + 2.5% and of capacity 4 KVA, with low and high voltage cutoff protection, protect equipment from potentially danger voltage , built in thermal tempreture burnout with latest IC technology and assories completeincluding taking down the existing voltage stabilizer any type and make and deposit the same in Ref Section of AGE (E/M) of GE AF Bhisiana complete all as sepcified and directed by the Engr-in charge. |
| 43 | Supply and fix voltage stabilizer for Automatic operation with digital display for IP & OP voltage , copper wound, single phase natually air cooled indoor type & designed for input variation between 130V to 270V with output valtage stabilized at 230V with accuracy if + 2.5% and of capacity 5 KVA, with low and high voltage cutoff protection, protect equipment from potentially danger voltage , built in thermal tempreture burnout with latest IC technology and acessories completeincluding taking down the existing voltage stabilizer any type and make and deposit the same in Ref Section of AGE (E/M) of GE AF Bhisiana complete all as sepcified and directed by the Engr-in charge. |
| 44 | S&F voltage stabilizer for Automatic operation with digital display for IP & OP voltage , three phase , naturally oil cooled, indoor type & designed for input variation between 300V to 480 V with output voltage stabilized at 415V with accuracy +2.5 % and speed of correction 8 volts per second and of capacity 10 KVA complete including taking down the existing voltage stabilizer any type and make and deposit the same in Ref Section of AGE (E/M) of GE AF Bhisiana complete all as sepcified and directed by the Engr-in charge |