| 1 | Excavation in trenches not exc 1.5 m wide and n. exc 1.5 m depth or n. exc 10 Sqm on plan and n exc 1.5 m in depth for Laying pipes,in any type of soil & getting out, complete all as specified and directed. |
| 2 | Demolition of Concrete of any description and in any position not otherwise specially provided complete all as specified and directed. |
| 3 | Demolition of reinforced cement concrete in Roof, floors(other than ground floors), beams ,landings,chajjas and similar suspended workcomplete all as specified and directed. |
| 4 | S&F 100mm bore cast iron sand cast soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed. |
| 5 | S&F 75mm bore cast iron sand cast soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed. |
| 6 | S&F 100mm bore cast iron sand cast soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to walls complete all as specified and directed. |
| 7 | S&F 75mm bore cast iron sand cast soil, waste and vent pipes, in any length with or without ears, with cement joints,fixed to walls complete all as specified and directed. |
| 8 | S&F 100mm bore cast iron bends sand cast (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access door complete all as specified and directed. |
| 9 | S&F 75mm bore cast iron bends sand cast (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access door complete all as specified and directed. |
| 10 | Extra over 100 mm Bore of pipe cast iron pipes and fittings if lead joint is provided in lieu of cement joint complete all as specified and directed. |
| 11 | Extra over 75 mm Bore of pipe cast iron pipes and fittings if lead joint is provided in lieu of cement joint complete all as specified and directed. |
| 12 | S & F of 100 mm Bore of pipe SocketCast Ironvent pipes complete all as specified and as directed. |
| 13 | S & F of 75 mm Bore of pipe SocketCast Ironvent pipescomplete all as specified and directed. |
| 14 | S & F of 100 mm Bore of pipe Cast Iron Vent pipecowls complete all as specified and as directed. |
| 15 | S & F of 100 mm Bore of pipe cast iron pipes ,double Branch pieces, single (equal or unequal), ordinary or inverted(spigot or socket type)or with parrallel branches fitted with oval access door complete all as specified and directed. |
| 16 | S & F of 75 mm Bore of pipe cast iron pipes Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parrallel branches fitted with oval access door complete all as specified and directed. |
| 17 | M&L Precast cement concrete type C-1 (1:3:6) (20mm graded stone)block masonrywith solid blocks exc. 10 cm in width and setting in cementmortar1:6 complete all as specified and directed. |
| 18 | M&L Cement concrete (1:2:4) type B–0 (12.5 mm graded stone aggregate) filling of pressed steel frame and hold fast blocks etc complete all as specified and directed. |
| 19 | S & F framed work such as grills, grating, etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming toFe 290 – Gde – 165 complete all as specified and directed. |
| 20 | M&L rendering 10 mm thick on stone masonry surfaces or surface but other than fair face of brickwork in CM (1:6)finished even and smooth (without using extra cement) complete all as specified and directed. |
| 21 | S & F of 100 mm Bore of pipe reinforced concrete pipes, class NP2 , laid and jointed complete with collers complete all as specified and directed. |
| 22 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed. |
| 23 | Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 24 | Dismantling cast iron work of any description complete all as specified and directed. |
| 25 | S&F 100mm bore cast iron bends sand cast (any radius), diminishing pieces or tapers (larger bore measured) fitted complete all as specified and directed. |
| 26 | S&F 75mm bore cast iron bends sand cast (any radius), diminishing pieces or tapers (larger bore measured) fittedcomplete all as specified and directed. |
| 27 | S & F of 100 mm Bore of pipe castIron traps P or Sfittedcomplete all as specified and directed. |
| 28 | S & F of 75 mm Bore of pipe castIron traps P or Sfitted complete all as specified and directed. |
| 29 | S&F for 150x100 mm (Size of gully traps) Salt-glazed stone ware gully trarps, squre or round mouthered , type, setting and jointing to drains with cement mortar (1:1) complete all as specified and directed. |
| 30 | M & L for 100mm diameter of outlet cast iron floor trap,with grating including jointing to waste pipe fixed in cement concrete type B-1(1:2:4)fitted complete all as specified and directed. |
| 31 | M & L for 75mm diameter of outlet cast iron floor trap,with grating including jointing to waste pipe fixed in cement concrete type B-1(1:2:4)fitted complete all as specified and directed. |
| 32 | M & L Non - skid joint free Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile, exceeding 0.11 sqm but not exceeding 0.18 sqm, with15mm thickscreed bed or bedding layer of cement mortar (1:6), for laying floor finishes etc, set and jointed in neat cement slurry and pointed in whiteor coloured cement to matchcomplete all as specified and directed. |
| 33 | M & L for coloured Glazed ceramic tiles in vertical surfaces 350x250x7mm/ 450mm x 300mm,7 mm thickover and including 10 mm thick Backing coat in CM (1:3) on fair faces of brick work or concrete surfaces , set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed complete all as specified and directed. |
| 34 | M&L for preparing new plastered or unplastered surfaces of walls and applying three coat of whitewash on walls complete all as specified and directed. |
| 35 | S & F of 100 mm bore of reinforced concrete pipes Bends, laid and jointed completeall as specified and directed. |
| 36 | M & L for Demolition of unreinforcedcement Concrete in ground floors and pavings n exc 15 cm thickness( below or above ground level )complete all as specified. |
| 37 | M & L for 75mm thick PCC 1:3:6 type C2 using 40 mm graded aggregate as in sub bases,sub floors ,plinth protection etc,finished even and fair without using extra cement complete all as specified and directed. |
| 38 | S&F for 75mm bore PVC pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |