| 1 | Taking down carefully old unserviceable existing copper/aluminium point wiring (light, fan, socket or power) complete including teak wood battens or from existing conduits with all fittings, such as switches, ceiling rose, pendants, sockets, lamp holder, fan regulators, sketch/brackets, light fittings (except tube light fitting) etc but excluding ceiling fan and removal of old material from site and making good disturbed surfaces of walls, floors ceiling etc to match with existing surfaces complete all as specified and directed. |
| 2 | M&L for point wiring for one light point/ceilingfan point controlled by one switch with 1.5 SqmmPVC insulated, sheathed multi strand copper conductor cable FR-LSH 1100 volts including PVC casing caping size 20/25mm including suitable size PVC box with cover plate for fixing switch/socket flush to surface for one light point, fan point , controlled by one switch on the same board with other switch or independent including PVC insulated sheathed 1.5 Sqmm multi stranded copper conductor cable FR-LSH 1100 volts connected to common earth dolly complete all as specified and directed.Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of Sch \"A\". |
| 3 | All as per srl item No. 13.00 (here-in-before) but for one 3 pin socket out let 5 Amp on same board. |
| 4 | All as per srl item No. 13.00 (here-in-before) but for one socket point outlet3 Pin, 5 Amp 230 Volt on independent board. |
| 5 | All as per srl item No. 13.00 (here-in-before)but for 15 Amp socket out let by using 2.5 Sqmm PVC insulated sheathed copper conductor cable FRLSH multi strand on independent boardincluding provn of2.5 Sqmm unsheathed, multi strandedcopper conductor cable FRLSH continues as earth wire connected to earth dolly etc complete all as specified and directed. |
| 6 | S& F piano switch flush type piano switch, 6 Amp 240 VoltAC,1 module(ISI Marked) one way etc complete all as specified and directed. |
| 7 | S&F socket outlet 3/5 Pin 6 Amp 230 volts AC flush type 2 in 1 complete all as specified. |
| 8 | S&F socket outlet flush type 3 pin 16 Amp, 230 volts ACcomplete all as specified and directed. |
| 9 | S&F switch socket combination 3 pin 6 Amp, flush type complete all as specified and directed. |
| 10 | S&Fstepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed. |
| 11 | S&FLamp holder of PVC / Polycarbonate, surface type for LED bulb complete all as specified and directed.. |
| 12 | S&F ceiling rose surface polycarbonate 65mm x 50mm,3 terminalswith back plate etc complete all as specified and directed. |
| 13 | S&Fin replacement ofLED batton fitting1 x18/20 Watt, 6000K, 4\" complete fitting incl taking down unsv fitting complete, connection with 2 core flexible cable 23/0.00076 from ceiling rose to tube fitting connection etc complete all as specified and directed. |
| 14 | S&F in replacement ofLED light fitting 9/10Watt ,6000Kindoor domestic mirror light luminarire with poly carbonate cover incl taking down unsv fitting complete, complete with all acessories and driver including connections with with twin core wire of suitable size all as specified. |
| 15 | S&F in replacement ofDecorative wall mounting fixture, in double plastic body &designer mesh in gold finish suitable for 9/10 W bulk head fittingcomplete all as specified and directed. |
| 16 | S&Fin replacement ofLED flameproof light1X16/20 Watt, 4\" long with die cast alluminium housing with heat resistance toughten glasswith LED tube lightfixture driver, holder, connector etc prewiredincluding connecting up with 3 corecopper cable in steel flexible pipe complete all as specified and directed. |
| 17 | S&F inreplacement ofaviation obstruction light die-cast aluminium alloy housing,red coloured polycarbonate dome and accessories complete all as specified and as directed. |
| 18 | S&F in renewal LED Ceiling light square recessed mounted LED flat panel complete 600mm x 600mm, 230 volts 35/36 Watt LED light fixing on Surface/ceiling and connecting with 3 corecopper conductor FR-LSH cable etc complete all as specified and directed. |
| 19 | Supply and fixing in replacement of U/S highmast flood light luminaire of HPSV/MH,with LED flood light fitting consist of PDC aluminium houseing in powder coated dia costing power coted in gray finish,high power LED with IP 66protection, fins are provided on housing ,heat resistant tempered glass for protectionwith 5 kv surge protection of 150 W LED as specified and directed. |
| 20 | S&F in replacement of HPSV/MH High bay light fitting with highbay luminare LED light fitting 200 watts, system wattage: 200 W, Lumen package : 24000 Lm, luminaire efficacy:> 120 Lm/W, four stage electrical protection : over/under voltage protection, short circuit and reverse polarity protection, Over temperature protection, Die-cast aluminium housing with dedicated optics for excellant beam distribution, Life: 50000 Hrs @L70, color temperature : 5700K + 300K, surge protection of internal 4kV and external 4kV complete all as specified and directed. Note:- Cost of neccessary tools and plants such as ladders, hydra for repair of high raised high bay / medium bay / low bay luminaires, suitable hanging items such as clamps/hooks/down rod etc should be deemed to be included in the unit rate quoted. |
| 21 | S&F in replacement of HPSV/MH High bay light fitting with highbay luminare LED light fitting 250 watts, system wattage: 200 W, Lumen package : 24000 Lm, luminaire efficacy:> 120 Lm/W, four stage electrical protection : over/under voltage protection, short circuit and reverse polarity protection, Over temperature protection, Die-cast aluminium housing with dedicated optics for excellant beam distribution, Life: 50000 Hrs @L70, color temperature : 5700K + 300K, surge protection of internal 4kV and external 4kV complete all as specified and directed.Note:- Cost of neccessary tools and plants such as ladders, hydra for repair of high raised high bay / medium bay / low bay luminaires, suitable hanging items such as clamps/hooks/down rod etc should be deemed to be included in the unit rate quoted. |
| 22 | S&F in replacement offlame proof switch rotary type with termination box in LM 6,16 Amp , Single pole ON-OFF, 240 Volt Complete all as specified and as directed. |
| 23 | S&Fin replacement of LED light fitting, 1X25 watt,5700 Kcomplete with tuff net glass protectionIP:66, fixed to walls incl taking down unsv fitting complete, with GI bracket made out of suitable size of light grade pipe 32 mm dia tubing upto 1.2 mtr length bent to shape with 02 sets of MS clamps made out of 25x3 mm MS flat iron with suitable bolt and nuts and testingetc complete all as specified and directed. |
| 24 | S&Fflame proof / weather proof Exhaust fan 12\" singlle phasewith louverscomplete all as specified and as directed. |
| 25 | S&Fin replacement of10Wflame proof / weather proof LED Bulkhead light fittingcomplete all as specified and as directed. |
| 26 | M&L for Sub main wiring with 2 runs of 4 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC casing caping with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof and one run of 4 Sqmmsingle core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cableas earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth conductor and one run of PVC casing capingshall be measured and paid as one unit length. |
| 27 | M&L for Sub main wiring with 4 runs of 6 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and PVC conduit of size 32mm ISI marked with all accessories fixed on wall/roof and one run of 6 Sqmmsingle core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cableas earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Four runs of 6 Sqmm cable, one run of 6 Sqmm earth conductor and one run of PVC conduit shall be measured and paid as one unit length. |
| 28 | M&L for Sub main wiring with 2 runs of 6 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and PVC conduit of size 25mm ISI marked with all accessories fixed on wall/roof and one run of 6 Sqmmsingle core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cableas earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 6 Sqmm cable, one run of 6 Sqmm earth conductor and one run of PVC conduit shall be measured and paid as one unit length. |
| 29 | S&F copper wire of size 2.5 Sqmm x 3 core PVC insulated unsheathed multistrand EC grade bright annealed copper industrial cable of 1100 volts as per IS: 694 complete all as specified and directed. |
| 30 | S&F copperwire of size 4 Sqmm x 3 core PVC insulated unsheathed multistrand EC grade bright annealed copper industrial cable of 1100 volts as per IS: 694 complete all as specified and directed. |
| 31 | S&F in replacement double doorVTPNDistribution boxsheet metal enclosuremade out of CRCA mild steel sheet concealed surface mounting , 8 way, 415 Volt,fitted with shrouded nutral , insulatedpin type copper bus bar , Dinrail , earthbar ofof 4 way ,complete with MCCB 160 Ampsas incoming complete all as specified and directed. |
| 32 | S&F sheet metal enclosure MCB distribution boardtriple pole & neutral 415 volts 4 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link,fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification. including taking down old complete all as specified and directed. |
| 33 | S&F sheet metal enclosure MCB distribution boardsingle pole & neutral 240 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link,fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification including taking down old complete all as specified and directed.ted. |
| 34 | S&F sheet metal enclosure MCB distribution boardsingle pole & neutral 240 volts 12 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link,fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification including taking down old complete all as specified and directed. |
| 35 | S&F in replacement of Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket, one single pole 20 Amps, 240V MCBcomplete all as specified and directed. |
| 36 | S&F in renewal Isolator TPN 100 Amps C curve MCB, 240 V repturing capacity 10 KA etc complete all as specified and directed. |
| 37 | S&F in renewal MCB TPN 63 Amps C curve MCB, 240 V repturing capacity 10 KA etc complete all as specified and directed. |
| 38 | S&F in renewal MCBSPN 63 ampC curve MCB, 240 V repturing capacity 10 KA etc complete all as specified and directed. |
| 39 | S&F in renewal MCBSPN 40 ampC curve MCB, 240 V repturing capacity 10 KA etc complete all as specified and directed. |
| 40 | S&F in renewal MCB 6 Amp to 32 Amp SPcapacities \"C\" series, 240 V,10KA rupturing capacaity complete all as specified and directed. |
| 41 | S&F blanking plate for empty space in DB boxescomplete all as specified and as directed. |
| 42 | Taking down serviceable/unserviceable Wall mountedfan 450mm sweep230 V, AC, single phase from qtrs, dismantling the wall mountedfan and taking out completerewindingthe same with super enameled copper winding wire of existing gauge & size including throughly cleaning all the components of fan, oiling varnishing the fan with and including replacement of rusted/unserviceable nuts, bolts, split pin, rubber reel, flexible twin core copper cable of size 23/.00076 approximate one metre long for each fan, machine screws and painting the fansetc, and refixingthe repaired fan to respective qtrs complete all as specified and as directed. |
| 43 | Taking down serviceable/unserviceable Air circulator wall mounted fan 650mm sweep230 V, AC, single phase from qtrs, dismantling the air circulatorwallmountedfan and taking out completerewindingthe same with super enameled copper winding wire of existing gauge & size including throughly cleaning all the components of fan, oiling varnishing the fan with and including replacement of rusted/unserviceable nuts, bolts, split pin, rubber reel, flexible twin core copper cable of size 23/.00076 approximate one metre long for each fan, machine screws and painting the fansetc, and refixingthe repaired fan to respective qtrs complete all as specified and as directed. |
| 44 | Taking down serviceable/unserviceable ceiling fan 1200mm/1400 mm sweep230 V, AC, single phase from qtrs, dismantling the ceiling fan and taking outand deposited at MES Store yardcomplete all as specified and as directed |
| 45 | Supply and fixingSingle phaseceiling fan1200 mm permanent magnet brushless DC Motor 230 v 50 Hz single phase 26-35 watt rated pf 0.98 360 rpm air delivery 220m3, 5 star with rated service value min 6m2/min/watt with 5 Year Warranty, no of blades three type of blade leaf min 1.05 mm thick aluminium sheet remote control radio frequency 5 speed +off timer option speed regulation class of insulation two nos bearings including connecting wire complete with all as required and directed. |
| 46 | S & F Exhaust fanheavy dutysize sweep 300 mm sweep,230 v, 50 Hz , completewith metalic louversincluding making holes and making good the disturbed surface and 3 core copper wire of size 0.50 sqmm for connectioncomplete all as specified and directed. |
| 47 | Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 core complete all as specified and directed.Note:-(i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 48 | Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core complete all as specified and directed.Note:-(i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 49 | Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core complete all as specified and directed.Note:-(i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 50 | Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core complete all as specified and directed.Note:-(i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 51 | Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core complete all as specified and directed.Note:-(i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 52 | Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core complete all as specified and directed.Note:-(i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 53 | Supply and install, testing and commissioning of LT panel board outdoor cubicle type floor mounted poly carbonatesheet, weather proof to accommodate the following controls:-(a) MCCB 400 Amp, 35 kA,4 Pole - 1 Nos.(I/C )(b)MCCB 100 Amp,16 kA,4 Pole - 6 Nos.(O/G ) (c)CTs 500/ 5 ma - 1 Set of 3(d) .Digital Panel Meters Class 1with 3 Phase Voltage, Current Frequency, PF, KW,KVA,KVAR and kWh - 1 No(e) Aluminium Busbar 500 Amp - 1 set of 4complete wiring of panel & Installation with PCCand Angle iron Standcomplete all as specified and directed. |
| 54 | M&L forreplacement of Test point terminal block made of Gun Metal or Phosphorous bronze size 75 x 75 x 25 mm drilled & screwed incl 3 Nos, 8mm dia, 25mm long Hexagonal head Screw complete all as specified and directed. |
| 55 | S&F in replacementof copper strip 20mm x 3.15mm with saddels and fixingscrews for roof conductors and down conductors above ground, earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/ pipe or fixed to poles or fixed to wall on insulators or any other indicated situation for loop earthing etc as required copper strip of size 32mm x 6mm complete all as specified and directed. |
| 56 | S&F in replacementofAluminium strip 25X3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed. |
| 57 | S&F in replacementofAir termination , single pointed aluminium rod 12 mm dia and 300 mm long complete all as specified and directed. |
| 58 | S&F in replacementofPCC pit cover in replacement of old unserviceablepit cover complete all as directed. |
| 59 | S&Fearthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burredin ground vertically earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick eachconnected to and including GI earth wire 4 mm dia by means of GI nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate upto 5 mtr and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 using 20mm stone aggregates for earthing pit, 10mm thick cast iron cover with angle iron frameand shown in electrical plate No 3 of SSR Part-I and testing on complete including dismantling old earthing all as specified and directed.Note: (i) Rate of excavation, earthwork, charcoal, PCC pit is covered under this item.(ii) The unit rate includes for protection pipe and GI wire 4mm from top of earth plate up to 7.5 meter above ground level. |
| 60 | M&L for Earthing complete with galvanized steel earth plate electrodes 600 mmx600 mm x 6 mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including galvanized GI strip 25X4mmby means of bolts, nuts, check nuts and washers of galvanized iron and steel including PCC pit in PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate, RCC framewith 40mm thick RCC cover reinforced with 8mm dia deformed barshandle. including excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 40 mm bore main board complete all as shown in electrical plate No 3connected to main control board all as specified and testingon completion including dismantling of old earth plate complete all as specified and directed. Note: (i) Rate of excavation, earthwork, charcoal, PCC pit is covered under this item.(ii) The unit rate includes for protection pipe and GI strip 25 x 4mm from top of earth plate up to 7.5 meter above ground level. |
| 61 | M & L for earthing complete with copper earth plate 60 cm X 60 cm X 3.15 mm thick buried directly (vertically) in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to copper strip 20 x 3 mm earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 40mm bore for protection of strip and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 5 complete including dismantling of old earth plate complete all as specified and directed. Note: (i) Excavation, earthwork, charcoal, PCC pit is covered under this item.(ii) Contractor shall be produced the result of earth below 1 Ohm othrewise earthing will not be acceptable. |
| 62 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for layingunderground cable in soft/losse soil complete all as specified and directed. |
| 63 | Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 64 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in any type of soil complete all as specified and directed. |
| 65 | Material and labour for dry tibba sand in trenches cushioning to under ground cable spreading, levelling hand punning complete all as specified and directed.Note- Punned down thickness will be measured for payment purpose |
| 66 | Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm, laid by dry and abutting each other with gap between adjacent slab not exedding 10 mm over under ground cable for protectioncomplete all as specified and directed. |
| 67 | Supply and laying/ fixing GI tube, light grade, 40mm dia for encasing cables for mechanical protection, laid under plinth/ floors/ path/ culverts or fixed on wall or concealed in wall/ floor or along poles or as street light polesor as mounting bracket, bent to shape with complete accessories such as bends/ sockets/ reducers/ saddles including necessary threading/ drilling works complete all as specified and as directed. |
| 68 | M&L for cutting of road / hardstanding upto a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable protection pipe line and finished surfaces by extracted material and provided with 150mm thick PCC (1:3:6) type C-2 as top layer to match the existing surfaces and remove surplus extracted material 50 m away complete all as specified and directed. |
| 69 | Disconnecting and Taking out of old LT armored PVC cables from trenches of any size/core/any voltage grade from trenches for replacement all as directed. |
| 70 | Supply and laying/ fixing GI tube, light grade, 80mm dia for encasing cables for mechanical protection, laid under plinth/ floors/ path/ culverts or fixed on wall or concealed in wall/ floor or along poles or as street light polesor as mounting bracket, bent to shape with complete accessories such as bends/ sockets/ reducers/ saddles including necessary threading/ drilling works complete all as specified and as directed. |
| 71 | Supply and laying/ fixing of GI tube, light grade, 50mm dia for encasing cables for mechanical protection, laid under plinth/ floors/ path/ culverts or fixed on wall or concealed in wall/ floor or along poles or as street light poles or as mounting bracket, bent to shape with complete accessories such as bends/ sockets/ reducers/ saddles including necessary threading/ drilling works complete all as specified and as directed. |