| Sl. No. | Item Description |
| 1 | Labour only for attending Emergency breakdowns of DG sets/AMF panels through skilled technician from reputed service centre of DG sets with necessary tool kits, checking Engine and alternator for defects, carryout necessary repairs works to rectify the defects without major overhauling/opening of Engine or Alternators, replace of external spare to repair/rectify the defects and testing DG set for its smooth functioning on full load all as specified and directed by Engr-in-charge. Note :1.Necessary spares required to rectify the defects shall be measured and paid separately under relavant items.2.The complaint shall be attended and rectifed within 24 hrs form time of reporting by Engr-in-Charge or his auth representative.3. Any Major defects shall be reported on Priority to Engr-in-charge to avoid undue delay in fuctioning of installation. |
| 2 | Visit of the OEM Engineers for the rectification of any fault pertaining to DG Sets of capacity 200 KVA to 320 KVA and connected accessories/ machineries i.e.. change of controller, sensor, thermostat, malfunction of harness wiring etc and making serviceable as per requirement complete all as specified and as directed. NOTE:Spare part shall be measured and paid separately . |
| 3 | Visit of the OEM Engineers for the rectification of any fault pertaining to DG Sets 63 KVA to 160 KVA and connected accessories/ machineries i.e.. change of controller, sensor, thermostat, malfunction of harness wiring etc and making serviceable as per requirement complete all as specified and as directed. NOTE:Spare part shall be measured and paid separately . |
| 4 | M&L formaintenance and servicing of DG set of capacity 320 KVA including alternator, electric panel board connection to DG set for routine checkof DG set for smooth functioning and carrying out maintanance of any capacity & make of DG Set, complete all as directed as specified by Engineer-in-Charge(a) Servicing/ repair of DG Set shall be carried out by authorised dealer/ agency of manufacturer.(b) Checking engine oil level and topping up as and when required . Note: (i) Note : Spare parts shall be measured and paid seperately. (ii) Checking and adjusting the belt for tension and replacement of belt. (iii) Checking of air filter element. (iv) Checking of exhaust system for leakage including rectification.(v) Draining of sediment from fuel filter and fuel tank(vi) Cleaning of air cleaner element(vii) Checking engine alternator coupling, mounting bolts and alignment(viii) Tighting all nuts, bolts, in altenator terminal block(ix) Checking of alternator carbon brush and connections in alternator(x) Checking and tighting of all connection in DC control wiring. |
| 5 | (a) Servicing of Engine |
| 6 | Re-greasing all grease point |
| 7 | Tighten the nuts, bolts of pipe lines of fuel oil, lubricating oil, water and check for leakages. Examine all main connecting rod connection. |
| 8 | Check water/coolant level in radiator and top up. |
| 9 | Check crank case oil level. |
| 10 | Clean lubrication oil filters. |
| 11 | Clean air filters. |
| 12 | Check that lubricating oil contains no water. Examine lubricating oil and renew if needed. |
| 13 | Check tappet clearance and all nuts for tightness. |
| 14 | Wash felt pads of fuel filter. |
| 15 | Drain air receiver. |
| 16 | Grease valve stems. |
| 17 | Check all wiring, battery water level, gravity of battery, inspect all brushes and brush holder, cleaning of surface of commuters. |
| 18 | (b) Servicing of alternators |
| 19 | Check temp rise of bearings. |
| 20 | Check brushes on exciter commuter and the alternator slip rings run without chattering or sparking. |
| 21 | Check if brushes freely slide in holder and whether brush springs are in order. |
| 22 | Check if oil rings are freely rotating in the bearings. |
| 23 | Check oil level in bearings. |
| 24 | Wipe clean the alternator and exciter. |
| 25 | Check all wiring and rectify and defect. |
| 26 | Surface and clean the commutater. |
| 27 | Take insulation and earth test on alternator and exciter and if defective investigate cause and remedy. |
| 28 | Check joints, clamping and bolting in all the wiring including control panels and rectify any defects. |
| 29 | Check greases in all roller and ball bearings and make up if inadequate. |
| 30 | Check the degree of wear of commuter brushes and renew if necessary. |
| 31 | Tighten all nuts in the rotors of alternative and exciter. |
| 32 | Check air gaps between starters and rotors and clean off any projections on the rotor. |
| 33 | All as per item No.4 above but 250 KVA, water Cooled make : Kirloskar/Cummins |
| 34 | All as per item No.4 above but 200 KVA and 160 KVA water Cooled Make: Cummins/Kirloskar |
| 35 | All as per item No.4 above but 100 KVA and 125 KVA water Cooled Make: Greavs cotton/cummins |
| 36 | All as per item No.4 above but62.5 KVA,Make: Cummins ,kiloskar & Mahindra and Mahindra |
| 37 | All as per item No.4 above but 35 KVA and 30 KVA and 40 KVA Make: Kirloskar and Mahindra |
| 38 | All as per item No.4 above but 10/15 KVA and 20 KVA Make:Cummins/greaves |
| 39 | Supply only Fuelfilter with ring including screen filter suitable for DG Sets of capacity 320 KVAMake: Cummins/Kirloskar |
| 40 | All as per item No.11 above but 250 KVA, water Cooled make : Kirloskar/Cummins |
| 41 | All as per item No.11 above but 200 KVA and 160 KVA water Cooled Make: Cummins/Kirloskar |
| 42 | All as per item No.11 above but 100 KVA and 125 KVA water Cooled Make: Greavs cotton/cummins |
| 43 | All as per item No.11 above but62.5 KVA,Make: Cummins ,kiloskar & Mahindra and Mahindra |
| 44 | All as per item No.11 above but 35 KVA and 30 KVA and 40 KVA Make: Kirloskar and Mahindra |
| 45 | All as per item No.11 above but 10/15 KVA and 20 KVA Make:Cummins/greaves |
| 46 | Supply only LubOilfilter suitable for DG Sets of capacity 320 KVA |
| 47 | All as per item No.12 above but 250 KVA, water Cooled make : Kirloskar/Cummins |
| 48 | All as per item No.12 above but 200 KVA and 160 KVA water Cooled Make: Cummins/Kirloskar |
| 49 | All as per item No.12 above but 100 KVA and 125 KVA water Cooled Make: Greavs cotton/cummins |
| 50 | All as per item No.12 above but62.5 KVA,Make: Cummins ,kiloskar & Mahindra and Mahindra |
| 51 | All as per item No.12 above but 35 KVA and 30 KVA and 40 KVA Make: Kirloskar and Mahindra |
| 52 | All as per item No.12 above but 10/15 KVA and 20 KVA Make:Cummins/greaves |
| 53 | Supply and fixing Air Filter element inner and outer suitable for existing type of DG set model of capacity 320 KVA |
| 54 | All as per item No.13 above but 250 KVA, water Cooled make : Kirloskar/Cummins |
| 55 | All as per item No.13 above but 200 KVA and 160 KVA water Cooled Make: Cummins/Kirloskar |
| 56 | All as per item No.13 above but 100 KVA and 125 KVA water Cooled Make: Greavs cotton/cummins |
| 57 | All as per item No.13 above but62.5 KVA,Make: Cummins ,kiloskar & Mahindra and Mahindra |
| 58 | All as per item No.13 above but 35 KVA and 30 KVA and 40 KVA Make: Kirloskar and Mahindra |
| 59 | All as per item No.13 above but 10/15 KVA and 20 KVA Make:Cummins/greaves |
| 60 | Supply only Coolentfilter suitable for DG Sets of capacity 320 KVA |
| 61 | All as per item No.14 above but 250 KVA, water Cooled make : Kirloskar/Cummins |
| 62 | All as per item No.14 above but 200 KVA and 160 KVA water Cooled Make: Cummins/Kirloskar |
| 63 | All as per item No.14 above but 100 KVA and 125 KVA water Cooled Make: Greavs cotton/cummins |
| 64 | All as per item No.14 above but62.5 KVA,Make: Cummins ,kiloskar & Mahindra and Mahindra |
| 65 | All as per item No.14 above but 35 KVA and 30 KVA and 40 KVA Make: Kirloskar and Mahindra |
| 66 | All as per item No.14 above but 10/15 KVA and 20 KVA Make:Cummins/greaves |
| 67 | Supply only superior grade engine oil 15W40 for DG set topping. Make: castrol /Turbo Max etc |
| 68 | Supply and topping coolent \"K\" Cool Super plus 50-50 Premix for radiator of water cooled engines of any make/capacity and as per manufacturers recommendation, complete all as specified & directed. |
| 69 | Supply and toppingdistilled water for battery or radiator of engine used with coolent \"K\" Cool Super plus 50-50 Premix all as specified and directed. |
| 70 | Supply only fuel water saperator suitable of any capacity DG Set of caapcity 320 KVA complete all as directed by Engr-in-Charge. |
| 71 | All as per item No.18 above but 250 KVA, water Cooled make : Kirloskar/Cummins |
| 72 | All as per item No.18 above but 200 KVA and 160 KVA water Cooled Make: Cummins/Kirloskar |
| 73 | All as per item No.18 above but 100 KVA and 125 KVA water Cooled Make: Greavs cotton/cummins |
| 74 | All as per item No.18 above but62.5 KVA,Make: Cummins ,kiloskar & Mahindra and Mahindra |
| 75 | All as per item No.18 above but 35 KVA and 30 KVA and 40 KVA Make: Kirloskar and Mahindra |
| 76 | All as per item No.18 above but 10/15 KVA and 20 KVA Make:Cummins/greaves |
| 77 | Oil Pressure gauge 0-10 bar suitable for 35/30/20/ 100/125/200 /KVA DG Set |
| 78 | Safety Control valve suitable for 20/30/35/62.5/100/125/160 KVA DG Set |
| 79 | Dismantling unserviceable battery charging dynamo from DG set of rating 1 x 12 / 2 x 12 Volts complete repairs and servicing including replacement of bushes, bearings, Carbon brushes, rectifires, rewinding of field magnet coil / rotor armeture coils and any other minor parts required all as directed and fixing on engine testing/commissioning complete for DG set having any capacity.Note :Replacement of rotor armeture coil, if reqd., shall be measured and paid seperately. |
| 80 | Dismantling self starter 12V/24 V of DG set for repairing the starter by replacing carbon brushes, brush holder, bearings, solenoid coil, replacement of burnt Armature, rewinding of Field Coils coils, replace of pinion gears etc, completer servicing and refixing after repair, testing/commissioning complete for DG Set any capacity. |
| 81 | S&F in repair solenoid coil suitable for DG set of capacity 20 to 62.5 KVA self starter, complete all as specified and directed. |
| 82 | S&F in repair solenoid coil suitable for DG set of capacity 100 to 200 KVA self starter, complete all as specified and directed. |
| 83 | S&F in repair solenoid coil suitable for DG set of capacity 250 to 320 KVA self starter, complete all as specified and directed. |
| 84 | S&F in repairarmeture coil complete with shaft suitable for DG set of capacity 20 to 62.5 KVA, complete all as specified and directed. |
| 85 | S&F in repairarmeture coil complete with shaft suitable for DG set of capacity 100 to 200 KVA, complete all as specified and directed. |
| 86 | S&F in repairarmeture coil complete with shaft suitable for DG set of capacity 250 to 320 KVA, complete all as specified and directed. |
| 87 | Removing existing defective wring of DG set panel, rewiring with mulitstrated single core PVC insulated copper conductor wire, 1.5 sqmm for AC/DC supply connections to all control system and devices and testing ofpanel after complete repair all as specified and directed. Note : Unserviceable spare like power contactor, auxilary contactor, Digital meters, relays, indication lamps, KWH meters, rotary selector switches etc shall be measured and paid separately under relavant items ,complete installation all as directed and specified. |
| 88 | S&F in replacement multifunction AMF panel control meter as per existing make provided in AMF panel board.As per existing make and model as per site requirement complete all as specified and directed. |
| 89 | S&F in replacement Battery With 180 AH , 12 Volts Suitable ForDG set With Electrodeincluding all accessories complete all Specified & Directed. |
| 90 | S&F in replacementBattery With 100 AH , 12 Volts Suitable For DG set With Electrodeincluding all accessories complete all Specified & Directed. |
| 91 | M&L for draining out coolent water from radiator, dismantling radiator, repair of radiator for leakage if any, cleaning the radiator set with dilute HCL, kerosin, fresh water and refixing the same with new rubber hose with clamps filling with coolent with distilled water and checking for its proper function on DG set all as directed and specified.Note : 1. Coolent and distilled water shall be measured and paid separately under relavant items.2. Brazing work shall deemed to be included in the quoted rate. |
| 92 | S&F in replacement battery lead length not less than 1.25 Mtr long and not more than 2.5 mtr as per connection requiremnt of each DG set, PVC insulated multistranded copper conductor 70 sqmm single core, duly fixed brass clamps, copper lugs for connections from DG battery to self starter on DG Sets of any capacity complete all as specified and directed. . |
| 93 | S & F in replacement emergency switch with assmbly including wiring, accessories complete make and model as per existing in the DG set all as specified and directed. |
| 94 | S&F in replacement rubber hose pipe set (Hose oil/Hose radiator/CR Hose/Makeup Hose) suitable for DG sets of capacity ranging from 20 KVA to 62.5 KVA, with GI clamps and Nut bolt, washers, as per existing make & model,complete all as specified and directed. |
| 95 | All as per item No. 36 here-in-above but suitable for100 KVA to 200 KVA capacity DG set |
| 96 | All as per item No. 36 here-in-above but suitable for250 KVA to 320 KVA capacity DG set |
| 97 | S&F in replacement flexible fuel pipeof minimum length 1 Mtr, complete set with banjo bolt and washer etccomplete all as specified and as directed. |
| 98 | S&F in replacement complete fan belts suitable for DG sets of capacity 320 KVA as per the existing sample and size complete all as directed by Engineer-in-charge. |
| 99 | S&F in replacement complete fan belts suitable for DG sets of capacity 250KVA as per the existing sample and size complete all as directed by Engineer-in-charge. |
| 100 | S&F in replacement complete fan belts suitable for DG sets of capacity 100 to 200 KVA as per the existing sample and size complete all as directed by Engineer-in-charge. |
| 101 | S&F in replacementcomplete fan belts suitable for DG sets of capacity 62 to 82.5 KVA as per the existing sample and size complete all as directed by Engineer-in-charge. |
| 102 | S&F in replacement complete fan belts suitable for DG sets of capacity 30 to 50 KVA as per the existing sample and size complete all as directed by Engineer-in-charge. |
| 103 | S&F in replacement Automatic Voltage Regulator with voltage / stability / pro adjustment for adjustment suitable for 250 to320 KVA DG Set as per site requirement specifications complete all as directed by Engineer-in-charge. |
| 104 | S&F in replacement Automatic Voltage Regulator with voltage / stability / pro adjustment for adjustment suitable for 20 to62.5 KVA DG Set as per site requirement specifications complete all as directed by Engineer-in-charge. |
| 105 | S&F in replacement Automatic Voltage Regulator with voltage / stability / pro adjustment for adjustment suitable for 100 to200 KVA DG Set as per site requirement specifications complete all as directed by Engineer-in-charge. |
| 106 | M&L for repairing the doors of sound proof enclosure of 20 to 62.5 KVA DG Set for proper closing and locking using new SS hinges/door handles / in built locks complete all as per existing all as specified and directed. |
| 107 | All as per item No 48 above but for DG set 100 -200 KVA DG set |
| 108 | All as per item No 48 above but for DG set 250 -320 KVA DG set |
| 109 | M & L in Repair/Servicing and calibration of FIP of following DG Sets including replacement of plunger, warn out gasket, sucction valve, discharge valve,manifold washer, etc all as required and testing after refixing on engine and setting the rated RPM all as directed by Engr-in-Charge.Note :- Repairing and caliberation shall be carried out by contractor workshop/ authorised dealer only. |
| 110 | DG Set of capacity - 100/125 /200 KVA |
| 111 | All as per Item No.51 but suitable for 250/320 KVA DG Set . |
| 112 | All as per Item No.51 but suitable for 62.5/35 KVA DG Set . |
| 113 | M&L in repair of turbo charger complete all as directed by Engr-in-Charge assembly for the following capacity of DG set :- |
| 114 | DG Set of capacity -35/30/20/40 KVA DG Set make: as per sample |
| 115 | All as per Item No.52but suitable for 125/100/62.5/160 KVA DG Set make As per sample |
| 116 | All as per Item No.52 but suitable for320/250/200KVA Make: as per sample |
| 117 | Supply & fix 3/4 pole power contactor MCE- 15 R (02 No and 02 NC), 100 Ampsof existing capacity suitable for any DG set , AC 415 Volts, 50 Hz for AMF panel including testing or as per existing make/type/rating/model for AMF panel boards etc and taking down old unserviceablecomplete all as directed by Engr-in-Charge Make: L&T/ Schinder/ ABB. |
| 118 | Supply and fix 3/4 pole power contactor MCX 43 (2NO and 2NC), 400 Amps of existing capacity suitable for any DG set ,AC 415 Volts, 50 Hz for AMF panel including testing or as per existing make/type/rating/model for AMF panel boards etc and taking down old unserviceable complete all as directed by Engr-in-Charge. Make: L&T/ Schinder/ ABB. |
| 119 | Supply & fix 3/4 pole power contactor MCX 32 (2NO and 2NC),160 Amps of existingcapacity suitable for any DG set ,AC 415 Volts, 50 Hz for AMF panel including testing or as per existing make/type/rating/model for AMF panel boards etcand taking down old unserviceable complete all as directed by Engr-in-Charge. Make: L&T/ Schinder/ ABB. |
| 120 | Supply & fix 3/4 pole power contactor MCE 15 N, 100 Amps of existing capacity suitable for anyDG set ,AC 415 Volts, 50 Hz for AMF panel including testing or as per existing make/type/rating/model for AMF panel boards etc and taking down old unserviceablecomplete all as directed by Engr-in-Charge. Make: L&T/ Schinder/ ABB. |
| 121 | Supply and fix 3 pole Mini power contactor type MCX 22 100 Ampsof AC1 of existing capacity suitable alongwith left and right auxiliary contact (1NO +1NC) for upto 20 to 320 KVA DG set ,AC 415 Volts, 50 Hz for AMF panel including testing or as per existing make/type/rating/model for AMF panel boards etc and taking down old unserviceable complete all as directed by Engr-in-Charge. Make: L&T/ Schinder/ ABB. |
| 122 | S&Fin replacement of 4 pole power contactor GMC-150/4 , 415 volt as per existing make and rating suitable for 63 to 320KVA DG set, complete all as specified & directed by Engineer-in-Charge.Make: L&T/ Schinder/ ABB. |
| 123 | S&Fin replacement of 4 pole power contactor GMC-300/4 , 415 volt as per existing make and rating suitable for 63 to 320KVA DG set, complete all as specified & directed by Engineer-in-Charge. Make: L&T/ Schinder/ ABB. |
| 124 | S&Fin replacement of 4 pole power contactor GMC-630/4 , 415 volt as per existing make and rating suitable for 63 to 320KVA DG set, complete all as specified & directed by Engineer-in-Charge. Make: L&T/ Schinder/ ABB. |
| 125 | S & F in replacement Procom DGC-6D controller for electronic control panel for DG set of 10 KVA to 320 KVA or existing make/type/rating/model for AMF panel boards etc complete all as directed by Engr-in-Charge. |
| 126 | S & F in replacement ET-8000 controller of electronic control panel for DG Set of 10 KVA to 320KVA of existing make/type/rating/model for AMF panel boards etc complete all as specified and directed. |
| 127 | M&L in replacement for electronic digital annunciator for DG Set AMF Panel as per existing make,model & capaicty etc complete as specified and directed |
| 128 | S & F in replacement of old unserviceable indicator lamp set RYB for phase indications suitable for panel to match with the existing one complete all as specified and directed by Engineer in charge. |
| 129 | S&F in replacement oil temperature gauge as per existing make suitable for any capacity of DG Set complete all as specified & directed by Engineer-in-Charge. |
| 130 | Supply and fixing in replacement water temperature gauge as per existing make suitable for any capacity of DG Set complete all as specified & directed by Engineer-in-Charge. |
| 131 | S&F in replacement Oil Pressure gauge suitable for existing make of any capacity DG set complete all as specified & directed by Engineer-in-Charge |
| 132 | S&F in replacement STOP EMERGENCY switch, suitable for any capacity of DG Set complete all as specified & directed by Engineer-in-Charge |
| 133 | M&L in replacement for digital/analog ammeter as per existing make,model & capcity etc complete all as directed by Engr-in-Charge. |
| 134 | M&L in replacement for digital/analog voltmeter as per existing make,model & capcity etc complete all as directed by Engr-in-Charge. |
| 135 | M&L in replacement for VAF/AAVF meter as per existing make, model & capacity etc complete all as directed by Engr-in-Charge. |
| 136 | M&L in replacement for engine starter relay of suitable capacity as required at site as per existing make,model & capcity etc complete as specified and directed |
| 137 | M & L in replacement for under voltage relay as per existing make,model & capcity etc complete all as directed by Engr-in-Charge. |
| 138 | M & L in replacement for over load relay as per existing complete all as directed by Engr-in-Charge make/model/capacity |
| 139 | M&L in replacementfor Earth fault realy as per existing capacitycomplete all as directed by Engr-in-Charge.Make : Teknika/L&T |
| 140 | M&L in replacement for Electronics type battery charger 24 volts,10 AH,input 220 Volts AC complete all as directed by Engr-in-Charge. |
| 141 | M&L in replacement for Electronics type battery charger 12 volts ,10 AH,input 220 Volts AC complete all as directed by Engr-in-Charge. |
| 142 | M&L in replacement ofPSO 500 controller of DG set AMF ofcapacity 20 KVA to100 KVA complete all accessories as per manufacturer complete all as directed by Engr-in-Charge. |
| 143 | M&L for openingAMF Panel of DG set, Cleaning of dust by using blower & cleaning agents. Checking/ Detecting faults, Removing Faults, Re-wiring of old unserviceable wiring & Testing of Control Wiring complete as reqd and closing of AMF Panel after replacement of unserviceable parts and testing on completion of job on existing load etc complete all as specified & directed by Engineer-in-Charge. |
| 144 | M&L in replacementformicroprocessor based power command control HMI 211 of DG set AMF of capacity 200 to 320 KVA complete including digitaly voltage regulation( fullwaverectified single phase(line to line) sensing,digital engine speedgoverning to provide isochrounous frequency regulation ,generator set monitoringmonitors status of all critical engineand alternator functions .start and stop control with operated 24 volts DC,generator setprotectioncomplete all as specified and directed by Engineer in charge |
| 145 | S & F in replacement of battery terminal clamps made up of brass heavy duty with nuts and bolts complete all as specified and directed by Engineer-in-Charge. |
| 146 | S & F in replacement of battery lead heavy duty of copper conductor standard red for positive and black for negative terminal with battery terminal of one end and battery lugs at other end upto 1.5 mtr long complete all as specified. |
| 147 | S&F PVC pipe of size 25 mm dia heavy duty for oil distibution including taking down old unserviceable complete all as directed by Engr-in-Charge. |
| 148 | M&L servicing/ cleaning of MS diesel tank of any capacity DG Set by draining out the diesel from tank, cleaning the tank with soap water/ suitable solution and painting the external surface with one coat of synthetic enamel paint of existing colour including replacement of drain valve, outlet pipe complete all as specified and as directed. |
| 149 | Supplying and fixing four pole `ON LOAD\" changeover in sheet metal enclosure with side operated handle suitable for415 volts ,50 HzAC supply including fixed to walls/ panels with suitable size clamps, nuts, bolts ,washers and connection & testing and taking down old one etc complete all as specified and directed of the following capacity |
| 150 | 125 Amps Make Havells Cat part No IHCNFE0125 or its equivalent as specified make. |
| 151 | 250 Amps Make Havells Cat part No IHCNFE0250 or its equivalent as specified make. |
| 152 | 400 Amps Make Havells Cat part No IHCNFE0400 or its equivalent as specified make. |
| 153 | Supply and fix in replacement ofnew water pump assembly for the DG sets of capacity 10 to 63 KVA incl testing complete as directed by Engr-in-charge |
| 154 | Supply and fix in replacement ofnew water pump assembly for the DG sets of capacity 100 to 200 KVA incl testing complete as directed by Engr-in-charge |
| 155 | Supply and fix in replacement ofnew water pump assembly for the DG sets of capacity 250/320 KVA incl testing complete as directed by Engr-in-charge |
| 156 | Supply only in replacement empty barrel heavy duty made of PVC of 220 Ltr capacity for collection of a FOL from AF refueling section and for distribution of FOL in the various location of upper and lower camp of AF Station Udhampur |
| 157 | Supply only in replacement empty barrel heavy duty made of PVC of 50 Ltr capacity for collection of a FOL from AF refueling section and for distribution of FOL in the various location of upper and lower camp of AF Station Udhampur |
| 158 | Supply only in replacement empty barrel heavy duty made of PVC of 30 Ltr capacity for collection of a FOL from AF refueling section and for distribution of FOL in the various location of upper and lower camp of AF Station Udhampur |
| 159 | S&F fan assembly of DG set capacity 62.5/100/125 KVA /250 make : as per sample |
| 160 | S&F inreplacementof self starter of capacity 24/12 volt suitable for DG sets of capacity 63 KVA to 160 KVAby taking out old burnt out copper winding wire and rewinding with supper enameled copper wire of same gauge with barnish complete including replacement of unserviceable pinion, bush, solenoid coil, carbon brushes and tension spring complete including commissioning and testing all as specified and as directed. |
| 161 | S&F as in replacement of self starter of capacity 12/24 volts model and make as per existing suitable for DG set of capacity 200 KVA to 320 KVA, 1500 RPM, 6 cylinder, water or air cooled type complete including taking out carefully old unserviceable self starter and necessary commissioning and testing as per manufacturer\"s recommendation all as specified and as directed.[Make: Lucas/ Bosch] |
| 162 | S&F as in replacement of self starter of capacity 12/24 volts model and make as per existing suitable for DG set of capacity 10 KVA to 40 KVA, 1500 RPM, 6 cylinder, water or air cooled type complete including taking out carefully old unserviceable self starter and necessary commissioning and testing as per manufacturer\"s recommendation all as specified and as directed.[Make: Lucas/ Bosch] |
| 163 | M & L in replacement Power command control GADC321 and M&Lformicroprocessor based power command control GADC 321 includingmode of Auto and manual,startbutton,MCB,GCB,stop button,rest button, digitaly voltage regulation( fullwaverectified single phase(line to line) sensing,digital engine speedgoverning to provide isochrounous frequency regulation ,generator set monitoringmonitors status of all critical engineand alternator functions .start and stop control with operated 12 volts DC,generator setprotectioncomplete all as specified and direc ted by Engineer in charge make : Cummins/Kirloskar /Greaves |
| 164 | M & L in replacement Power command control 1301/1302 and M&Lformicroprocessor based power command control 1301/1302 including digitaly voltage regulation( fullwaverectified single phase(line to line) sensing,digital engine speedgoverning to provide isochrounous frequency regulation ,generator set monitoringmonitors status of all critical engineand alternator functions .start and stop control with operated 24 volts DC,generator setprotectioncomplete all as specified and direc ted by Engineer in charge |
| 165 | M&L in replacement for Governor PCBcard of DG set of capacity 20 to 62.5 KVA DG Setincluding feature accutator,pick up the speed for stability, gain and speed with droop nad idle positionalong with all accessories complete. |
| 166 | M&L in replacement for Governor PCB card of DG set of capacity 100 to 200 KVA DG Setincluding feature accutator,pick up the speed for stability, gain and speed with droop nad idle positionalong with all accessories complete. |
| 167 | M&L in replacement for Governor PCBcard of DG set of capacity 250 to 320 KVA DG Setincluding feature accutator,pick up the speed for stability, gain and speed with droop nad idle positionalong with all accessories complete. |
| 168 | M & L in replacement Power command control GC1211 and M&Lformicroprocessor based power command control GC1112 includingmode of Auto and manual,startbutton,MCB,GCB,stop button,rest button, digitaly voltage regulation( fullwaverectified single phase(line to line) sensing,digital engine speedgoverning to provide isochrounous frequency regulation ,generator set monitoringmonitors status of all critical engineand alternator functions .start and stop control with operated 12 volts DC,generator setprotectioncomplete all as specified and direc ted by Engineer in charge make : Cummins/Kirloskar /Greaves |
| 169 | M&L disconnecting of200 KVA to 320 KVA DG Set for repair/replacement/overhauling including the following spare parts & electric connection with takingdown parts related to engine overhauling and carrying out tranportation from AF Stn Udhampur to civ market with authorised agency and back to AF Stn Udhampur for refixing after repair at its original location including testing and commissioning of DG Set, complete all as directed by Engr-in-Charge. Note:- (a)Any Minor repair shall deemed to be included in the quoted rate.(b) Any other T&P required i.e hydra ,crane etc for lifting of DG set to workshop and after repairing refixing at working site shall deemed to be included in the quoted rate. |
| 170 | M & L for pistan set 6 Nos Complete |
| 171 | M & L forLiner set 6 Nos Complete |
| 172 | M & L for Liner o Ringset 6 Nos Complete |
| 173 | M & L for Ringset 18 Nos Complete |
| 174 | M & L for Head Gasket6 Nos Complete |
| 175 | M & L for Vave set Inlet of Exhaust12 Nos Complete |
| 176 | M & L for Head valve seal 12 Nos Complete |
| 177 | M & L for Head valve set 12 Nos Complete |
| 178 | M & L for L/Lop Sensor1 set Complete |
| 179 | M & L for Headoil filter 2 Nos Complete |
| 180 | M & L for fan belt set3 Nos Complete |
| 181 | M & L for paking kit1Nos Complete |
| 182 | M & L for AirCleaner element 1 Nos Complete |
| 183 | M & L for hose clamp4 set Complete |
| 184 | M & L forwasher 1 setComplete |
| 185 | M & L for fuel pipe line 2 picComplete |
| 186 | M & L forHain oil seal set1 set Complete |
| 187 | M & L for timing cover oil seal 1 set Complete |
| 188 | M & L forCraine Granding1 set Complete |
| 189 | M & L for Temp Sensor1 set Complete. |
| 190 | Allas per item No 102 But DG Set of capacity 62.5 to 160 KVA |
| 191 | M&L for rewinding of rotor complete with supper enameled copper wire as per existing size for DG sets of capacity 200 KVA to 320 KVA for further separating armature from stator carefully cutting , cleaning the slots and checking for defective stampingsand replacing the same with the new stampings made out of silicon steel of same size and thickness duly applying the insulation and assembling the stampings inserting in position in the stator including applying start insulation and complete re-winding the stator winding with super enameled copper winding of same gauge and same number of turns as per existing, including replacement of carbon brushes, tapping the winding and bringing out the coil connections for 3 phase, 415 volts, 50 Hz AC including pre heating the winding proper insulation material, varnishing and drying the winding complete all as specified and directed. |
| 192 | All as per item No 104 hereinbefore but DG Set capacity 62.5 KVA to 160 KVA complete all as specified and directed. |
| 193 | All as per item No 104 hereinbefore but DG Set capacity 10 KVA to 40 KVA complete all as specified and directed. |
| 194 | M&L for rewinding of stator main complete with supper enameled copper wire as per existing size for DG sets of capacity 200 KVA to 320 KVA for further separating armature from stator carefully cutting , cleaning the slots and checking for defective stampingsand replacing the same with the new stampings made out of silicon steel of same size and thickness duly applying the insulation and assembling the stampings inserting in position in the stator including applying start insulation and complete re-winding the stator winding with super enameled copper winding of same gauge and same number of turns as per existing, including replacement of carbon brushes, tapping the winding and bringing out the coil connections for 3 phase, 415 volts, 50 Hz AC including pre heating the winding proper insulation material, varnishing and drying the winding complete all as specified and directed. |
| 195 | All as per item No 105 hereinbefore but DG Set capacity 62.5 KVA to 160 KVA complete all as specified and directed. |
| 196 | All as per item No 105 hereinbefore but DG Set capacity 10 KVA to 40 KVA complete all as specified and directed. |
| 197 | S&F in replacement feed pump assembely of DG Set of capacity 250 to 320 KVA as per existing make and model as per site requirement complete all as specified and directed. |
| 198 | All as per item No 106 hereinbefore but DG Set capacity 100 KVA to 200 KVA complete all as specified and directed. |
| 199 | All as per item No 106 hereinbefore but DG Set capacity 10 KVA to 62.5 KVA complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail