| 1 | Surface excavation n. exc(not exceeding) 30 cm deep and averaging 15 cm deep and getting out in hard dense soil |
| 2 | Rough excavation not exceeding1.5 m deep and getting out in any type of soilcomplete all as specified and as directed. |
| 3 | M&L for Excavation in trenches n.exc. 1.5 wide and n.exc. 1.5 m deep and getting out in any type of soil |
| 4 | Excavation in trenches not exc 1.5 M deep and 1.5 M width and getting out in soft or loose soil for foundation of poles (or) cable laying. |
| 5 | All as per item No-4 but additional 1.5m or part thereof in depth beyond the first 1.5 m all as directed. |
| 6 | Returning filling in hard/dense soil including spreading levelling watering and well ramming in layers n. exc 25cm thick complete all as specified and directed |
| 7 | Excavation in post hole in hard/dense soil (or similar holes) each n. exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering, and removing surplus soil to a distance n. exc 50m and making good surface complete all as specified and directed |
| 8 | Removing excavated spoil to a distance not exc 50 mtr and deposited where directed at a level n.exc 1.5 mtr from the starting point complete all as specified and directed |
| 9 | M & L for hardcore of gauge n exc 63 mm deposited spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface of broken stone or boulders |
| 10 | M&L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in surface channel or drain or benching in manhole including necessary formwork complete all as specified and directed |
| 11 | M&L for 75mm thick PCC 1:3:6 type C1 (Using 20mm graded stone aggregate) as in plinth protection/path laid in panels, finish the top surfaces even and smooth complete including filling the joints with mastic compound all as specified and directed |
| 12 | M&L for cement concrete type C1 1:3:6 (20mm aggregate) in foundations, filling and mass concrete |
| 13 | M&L Cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundations or mass concrete complete all as specified and as directed |
| 14 | M&L for Precast cement concrete (PCC) type C21:3:6 using 40mm graded aggregate stone for making foundation of Pole/stay assembly complete all as specified and as directed |
| 15 | M&L for PCC 1:2:4 type B2 as in surface channel and drain & benching of manhole and finishing even and smooth without using extra cement complete all as specified and as directed |
| 16 | M&L for cement concrete 1:3:6 type C2 (Using 40mm graded stone agrregate) as in foundation of posts, railing and similar work complete all as specified and directed |
| 17 | M&L for PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in coping including necessary form work complete all as specified |
| 18 | M&L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in coping including necessary formwork complete all as specified and as directed |
| 19 | M&L precast cement concrete block masonry exc. 10 cm width with solid blockC1 (1:3:6) (using 20 mm graded stone aggregate) and settingin cement mortar (1:6) all as specified. |
| 20 | M&L precast cement concrete block masonry exc 10 cm width with solid block PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) and settingin cement mortar 1:4 all as specified |
| 21 | M&L for providing precast reinforced cement concrete cover slabs for drain in RCC (1:2:4) B-1, using 20mm graded aggregate setin cement mortar 1:4 complete all as specified and as directed. |
| 22 | M&L for Providing precast cement concrete solid building blocks or slabs Type B1 1:2:4 (20 mm graded aggregate) 10cm thick (with plain or interlocking joints as directed) setting in mortar, complete, in walls complete all as specified and as directed |
| 23 | Forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitered/stoppedends etc complete all as specified and directed |
| 24 | M & L Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface with or without reinforcement all as specified and as directed by Engineer-in- Charge. |
| 25 | Supply only liquid water proofing compound |
| 26 | M&L for 18-20mm thick granite stone (of any type ) work (table rubbed and polished) as in counter wash basin, cooking platform, window cill/jambs, steps,pillers, etc in CM (1:4) incl pointing in white cement (1:2) using marble dust with admixture of cement and pigment to match with shade of granite incl 15mm thick CM (1:4) bedding & pointed in white/coloured cement to match coloured tiles including grinding and rounding ( chamfering) to exposed edge of granite slab with mirror polishing complete all as specified and as directed. (Note : Colour of granite shall be as approved by Engr-In-Charge) |
| 27 | Taking down Chowkatsexc 1.5 Sqm but n. exc 4 Sqm each with shutters (Without taking off shutters from the frame) complete all as specified and directed |
| 28 | M&L for mild steel work as posts and struts in fencing including cutting tops as required drilling holes, notching for wires etc and similar works conforming to Fe-290 Gde E-165 complete all as specified and as directed |
| 29 | S&F framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works conforming to Fe-290, Gde-E-165 all as specified and as directed |
| 30 | S&F mild steel screw bolt (Machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, dia of shank 11 to 15 mm and length of bolt exc 5 cm but n. exc 10 cm complete all as specified and as directed |
| 31 | S&F mild steel round bars 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns, hooking ends and binding with MS post of grade Fe-410-W (Gde E-250) quality-A or Fe-290 (Gde-E-165) complete all as specified and directed |
| 32 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia for securing with clips quality conforming to deformed or twisted bars complete all as specified and as directed |
| 33 | S&F compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc built up from two or more beam or channel sections or angles with plates including all lattice bars, stiffeners, gusset plates conforming to Fe-410-W (Gde-E-250) quality-A complete all as specified and directed |
| 34 | S&F mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment (Fe-410W, Gde-E-250 Quality-A) complete all as specified and as directed |
| 35 | S&F Galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc as directed |
| 36 | S&F GI frame work for UPVC false ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flange of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm c/c intermediate channel 0.90mm thick having two equal flanges of 15mm each and web of 45mmsuspended from soffit at approx 900mm c/c with GI cleats and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thick having kurled wrb of 50mm and flanged of 26mm each with lips of 10.5mm fixed to be intermediate channel with connecting across the intermediate channel at 457mm c/c including hangers 6mm dia GI adjusting level fixed to roof slabs by makes of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed. |
| 37 | M&L for seamless false ceiling made out of 12mm thick of gypsum board 600mmx600mm fixed to the ceiling section with 25mm long self grilling and tapping screws having philips head with under head cutter at 200mm centre to centre, including finishing the joints of face board with specially formulated joining compound and 48mm wide fibre tape to provide seam less finish and including GI channels 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm c/c incl Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long incl thin layer of PoP with gysum binder,sanding the surface till smooth surface is obtained and finally applying two coats of acrylic emulsion over a coat of primer complete all as specified |
| 38 | M&L for 75mm thick PCC 1:4:8 type D2 (Using 40 mm graded stone aggregate) as in path laid in panels, finish the top surfaces even and smooth completeall as specified and directed |
| 39 | M&L for 100 mm thick PCC 1:4:8 type D2 using 40 mm graded stone as Sub Base complete all as specified and as directed |
| 40 | M&L for 100 mm thick PCC 1:3:6 type C2 (Using 40mm graded stone aggregate) as in sub base, finish the top surfaces even and fair complete all as specified and directed |
| 41 | M & L PCC 1:2:4 type B 0 (using 12.5 mm graded stone aggregate) 25 mm thick as in levelling course, sub-floors and paving etc complete all as specified. |
| 42 | M&L glazed ceramic coloured tiles as in vertical surfaces of size 300 x 450 x 7 mm thick set and jointed in neat cement slurry and pointed in coloured cement to matchincl 10 mm thick backing coat in CM (1:3) as specified |
| 43 | M&L for Non Skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exc 0.18 Sqm but n. exc 0.38 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:4 complete all as specified and directed |
| 44 | M&L chequered Cement concretetiles30 cmx30cmx 25 mm thick set, jointedand pointed neat cement slurry in floorwith grey cement and pigments , incl CM (1: 4) 20 mm thick screed bedall as specified and directed by Engr-in-Charge. |
| 45 | M&L Chequered cement concrete tiles (glossy finish) 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry with grey cement and pigments in floors,over and Including 20mm thick screed bed in CM 1:6 etc all as specified and as directed. |
| 46 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removingrubbish off the premises complete all as specified and directed |
| 47 | M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand Complete all as specified and directed |
| 48 | M&L for 10mm thick plaster in CM (1:4) on fair faces of concrete/PCC block surfacesof walls finished even and fair(without using extra cement)all as specified. |
| 49 | M&L for 15mm thick plaster in CM 1:4 on fair face of brick walls or concrete surface including mixing of liquid water proofing compound @ 200ml per 50 Kg cement bag, finished the surface smooth and even without using extra cement complete all as specified. (Note: Water proofing compound shall be measured and paid separately) |
| 50 | M&L for 10mm thick plaster in CM (1:6) on fair faces of concrete/PCC block surfacesof walls finished even and smooth (without using extra cement)all as specified. |
| 51 | Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed |
| 52 | M&L for preparation on newly plastered wall surface and applying two coats of cement base paint complete all as specified and as directed. |
| 53 | M&L for applying two coats of oil bound distemper of approved tint over a coat of average 1mm thick wall care putty on ceiling after complete removal of existing treatment complete all as specified and directed |
| 54 | M&L for applying two coats of oil bound distemper over a coat of average 1mm thick wall care putty to make the surface smooth after complete removal of existing treatment complete all as specified and directed |
| 55 | M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of average 2 mm thick wall care putty to make the surface smooth complete all as specified and directed |
| 56 | M&L for preparing newly plastered wall surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and directed |
| 57 | M&L for complete removal of existing treatment on plastered wall surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and directed |
| 58 | M&L forapplying two coat of synthetic enamel paint over a coat of red oxide primer includingpreparation of new steel surfaces of any description over 10cm width or girth not otherwise described complete all as specified and directed |
| 59 | M&L forapplying two coat of synthetic enamel paint over a coat of red oxide primer includingpreparation of new steel surfaces of any description over n.exc 10cm width or girth not otherwise described complete all as specified and directed |
| 60 | Taking up or down 20mm dia steel tubing connection, including cleaning for refixing or removal to store complete all as specified and as directed |
| 61 | Taking up or down 25mm dia steel tubing connection, including cleaning for refixing or removal to store complete all as specified and as directed |
| 62 | S& F for 20mm bore unplasticised PVC pipe of pressure ratings 10kgf/Sqcn including all fittings fixed complete to walls, ceiling or in floor etccomplete all as specified and as directed |
| 63 | S& F for 25mm bore unplasticised PVC pipe of pressure ratings 10kgf/Sqcn including all fittings fixed complete to walls, ceiling or in floor etc complete all as specified and as directed |
| 64 | Dismantling PVC water tanks exc 1000 Ltr but n. exc 2000 Ltr capacity and removing to store complete all as specified |
| 65 | S&F double layer rotational moulded PVC water storage tank cylinderical, vertical with closed top hoisted and fixed in position tank capacity 2000 Ltr with and including PTMT float valve 20mm dia and making connection for inlet and outletcomplete all as specified and directed |
| 66 | S&F for providing25mm dia Gun Metal, globe or gate valves with iron wheel head, screwed both ends for iron pipes complete all as specified and as directed |
| 67 | S&F for providing20mm dia Gun Metal, globe or gate valves with iron wheel head, screwed both ends for iron pipes complete all as specified and as directed |
| 68 | S& F for 20 mm dia Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed complete all as specified. |
| 69 | M&L for concrete bed in PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in bed with thickness of bed below the barrel of pipe as 100mm and width of bed as 460mm to sewage pipes of 160mm internal dia including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed |
| 70 | Demolition of precast cement concrete block walling built in CM or cement lime Mortar complete all as specified and as directed |
| 71 | Demolition of cement concrete un-reinforced in any position and paving not exc 15cm thick above or below ground level complete all as specified and as directed. |
| 72 | Demolition of Reinforced manhole, Drain over cover slabs in similar works etc complete all as specified |
| 73 | Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed |
| 74 | Dismantling of wallandceilingboards(fibre, pulp, insulation etc) or insulationboards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed |
| 75 | Supply and fix mild steel galvanised PVC coated chain link fencing 3.15mm nominal dia of GI wire, 1.4mm thick PVC coating and average area of aperture 25 sqcm with weight of chain link not less than 3.60 Kg/Sqm complete all as specified and directed |
| 76 | Supply and fixing of UPVC/ fibre false ceiling of panel (not less than 1mm thickness) sizes of 340mm x 2700mm/ 300mm x 2500mm, durable and resistant to moisture, water and borer-fungus-termite attack. Panels to be installed with GI/ Aluminium sections of suitable guuage & size according to site conditons. Panels fixed using with suitable trims for edges profiles and for connecting profiles. Panels must be maintenance free, rust proof and are 100% water proof complete all as specified and sample kept in the office of the Engr-in-Charge.Note:- i) Colour and pattern of false ceiling boards to be approved by GE.ii) GI frame work of false ceiling will be measured and paid separately. |
| 77 | S&F HDF wooden laminated flooring of approved make,color and shade,minimum thickness 5mm having wear resistance with tongue and groove interlocking system. Flooring to be laid over2mm thick foam underlay/moisture barrier sheeton existing level,dry and smooth subfloor. The work includes proper aligment,cutting,edge trimming,and locking of planks,leaving 8-10mm expansion gaps along walls and fixed objects, and covering the same with matching skirting/edge beading of approved make complete all as as per manufacturers specifications and directed by Engr-in-Charge |
| 78 | S & F Aluminium composite panel sheet of 3.0mm thick with skin thickness of 0.25mm of aluminium on both sides, sandwiched by 2.5mm polythelene core with PVDF coating of 30.0 micron with expansion fastener, having panels not exc 1200 x 1200mm with necessary silicon fitting, in approved pattern as in column, beam, wall etc. complete all as specified and as directed. Note:- Necessary MS scaffolding required for work shall be deemed to be included in the quoted rate. |
| 79 | S&F UD PVC drainage pipes (SJ Type) S165/SN8/SDR34 160mm dia in any length with rubber ring joints laid in trenches all as specified and directed. |
| 80 | M&L for steel tubular swaged poles 410 SP-31 (9.0 metres long) conforming to IS:2713 (Part-I) 1980, welded with mild steel base plate of size 300x300x6mm thick, finial taper plug, bolts, nuts and washers including two coats of aluminium paint over a coat of red oxide primer including taking down old unserviceable pole of any type complete all as specified and directed. Make : Kalinga Tubes/The National Tubes CO/India tube & CO/ Utkarsh |
| 81 | Supply, laying, testing and commissioning of underground LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of cross section 2 core x 16 sqmm (laid in terenches,ducts,pole,wall etc.) all as specified and directed. |
| 82 | M & L point wiring complete with 1100 volts grade, 1.5 sq.mm (nominal area), single core, FRLSH PVCinsulated ,unsheathed, multi stranded copper conductor cable drawn through and including medium grade, rigid , non-metallic PVC concealed/ on surface conduit of size not less than 20 mm dia, with all necessary fittings, concealedin walls/ floor or surface on wall/ roof duly earthed with one run of single core cable of same size but green incolour as continuous earthing wire and connecting to common earth duly including suitable size of factory made fabricated MS sheet modular terminal box, flush mounting in the wall for mounting switches/switch socket combinations/ fan regulators etc., covered with suitable size of modular cover plates complete in making good the existing surface with existing colour coding as required at site complete all as specified for the following :-Make of wire : V-Marc/Polycab/ Gloster/ Anchor/ Havells/ Finolex and Make of PVC Conduit or Casing & caping : Modi/ Precision/ Supreme/ Finolex/ Polycab.Note :- The unit rate quoted shall deemed to include the cost of following :-(a) GI metal flush box of minimum thickness of 1.6mm and modular cover plate with frame of any module complete.(b) Proper colour coding is to be followed as per IS specification.(c) Wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement.(d) Cutting chases in wall/floor /beam/ceiling to be concealed conduit and making good the disturbed surfaces. |
| 83 | All as per item Sl No 82 above but for One light/fan point controlled by one modular switch 5 Amps one way complete all as specified and directed. |
| 84 | All as per item Sl No 82 above but for two light point controlled by one switch 5 Amps one way complete all as specified and directed. |
| 85 | All as per item Sl No 82 above but for one bell point controlled by one modular bell push switch 5 Amps one way complete all as specified and directed. |
| 86 | All as per item Srl No.82 above but point wiring with 4.0 sqmm PVC FRLSH insulated multistranded copper conductor suitable for one 3 pin 16 Amps socket out let and one run of 4.0 sqmm cable for earth in green colour on independent board complete all as specified and directed. |
| 87 | All as per item Sl No 82 above but,point wiring for 3 pin switch socket outlet , 5 Amps on same board complete all as specified and directed. |
| 88 | All as per item sl No 82 above but,point wiring for 3 pin switch socket outlet , 5 Amps on independent board complete all as specified and directed. |
| 89 | S & Ffor switchmodulartype, 6 Amps1 module, 230 volts AC circuit complete all as specified anddirected. |
| 90 | S & F for switchmodulartype, 16 Amps 1 module, 230 volts AC circuit complete all as specified anddirected. Make : Roma (Anchor)/ Legrand/ Havells |
| 91 | S & Ffor socket outlet modular type 1 way 6 Amps, 3 pin, flush type 230 volts AC circuit complete all as specified anddirected. |
| 92 | S & F modular bell push 5 Amps 1 modular 230v, 50Hz AC complete all as specified and directed. Make : Roma (Anchor)/ Legrand/ Havells |
| 93 | S & F Socketoutlet 2 in 1 modular type,3 pin, 6 and 16 Amp , universal complete all as specified and directed.Roma (Anchor)/ Legrand/ Havells |
| 94 | S & F stepped type modular fan regulator, 2 modular type complete all as specified and directed. |
| 95 | M&L for Submain wiring complete with two runs (1P+1N) of4.0 sq mm single core 1100 V grade with stranded copper conductor cableusing proper colour coding Phase Red /Yellow /Blue, Neutral- black and earth- green in and incl rigid PVC concealed/surface conduit(ISI marked) incl all specials/ accessories etc and provision of PVC insulated FRLSHcopper conductor single core cable of same size but green incolour as continuous earthing wire all as directed. |
| 96 | M&L for street light mounting bracket made up of 40 mm dia galvanised steel tubing, medium grade, 1.20 metres long, bent to shape with inner angle not less than 120°, with and including necessary fixing clamps fabricated out of angle iron/flat iron of suitable size, bolts, nuts and washers as required and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. |
| 97 | S & F street light of cap 60 watt, aerodynamically designed for all weather conditions with excellent thermal management, made with pressure die cast housing with toughened glass and high power LED\"s with secondary optics and IP66 protection. Efficacy > 110/120 LPW, along with 10KV SPD all as specified and directed. CG model No TRP-409-60-57-SL-GL-NSG or equivalent to Havells |
| 98 | S & F PVC Insulated and PVC Round Sheathed 3 core 1.0 sqmm Bright Annealed Bare Copper Conductor Heavy Duty Flexible Cables for Voltage Grade 1100 Volts for connection of lights from junction box complete all as psecified and directed. |
| 99 | Supply & fix Cable Junction Box of size 155 x 210 x 92, IP 66 (Grey) with integrated membranes / metric knockouts for cable entry of size upto 25 sqmm twin core with earth, Lighting Outgoing cable: 3C x 1.5/ 2.5 Sq.mm cable, Degree of protection: IP66, Lighting MCB Rating: 10A,SP, B-Curve, current carrying capacity: 40A, Material: PC-GFS (polycarbonate) , Weatherproof, resistant to weather influences all as specified and directed. Make : Hensel model No DK 1616 Gor equivalent. |
| 100 | Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipeof size 50 mm (OD) x 38 mm (ID) along with connected accessories like couplers.bends,end caps etc. for LT cable protection all as specified and directed. |
| 101 | Taking down old timer panel and supply and fixing of out door type Street light timer Panel /Distribution Boards with pole, panel etc as directed alongwith 65A 3 pole/230 Voltscontactor and Digital 24 hrs/ Analog Time Switch, 63 A MCB, Manual and Auto Mode Toggle switch cable connectors, cable gland etc including suitable fixing arrangement with existing pole/ panel all as specified and directed. Make: Cat No. TL065AB0 of indoasian Time lite or equivalent in L&T / Havells |
| 102 | Earthing complete with galvanisedearth plate electrode 60 cm x 60cmx 6.15 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI earth wire 4 MM Dia as earthling lead by means boltsand nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel with wire mesh,.CI cover with frame etc including necessary excavation in any type of strata , returning, fillingremoval of soil outside MD land ,filling ofcharcoal andsalt complete all as shown in electrical plate No.3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mmc/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II.2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. |
| 103 | S & FModular Ac Box With 20A DP MCB \"C\" Type, Metal Enclosure & Unbreakable Heavy Duty With ISI Plug Top, 240 volts AC supply for air conditioner, flush mounting in the wall complete all as specified and directed. Make:- Anchor (Roma) model no 98492 or equivalent in L&T / Havells |
| 104 | S & Fandtesting Tube light fittings aluminium housing, Diffuser slim Integrated design LED 21 watts 4 feet, IP-20 including all accessories and fixing arrangements for fixing the light fitting complete all as specified anddirected. Make: Philips Cat Part No : BN021C LED22S or equivalent to CG/ Havells/ Luker |
| 105 | S & F andtesting Mirrior light fitting of cap 20 watt with all fixing arrangements all as specified and directed. Make-Havells cat no LHLDESAARANC020or equivalent to Philips/ CG |
| 106 | S & F Decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 base. Make-Havells model No LHFOAJE1TZ1I060 or equivalent in CG/ C&S |
| 107 | S & F of LED slim panel lighting fixture of 15 Watt recessmounted220V, 50Hzwith finished in premium white powder coating ,environmental friendly energy efficient fitting recessmounted round/squarein shape(Warm white/ white colour as per requirement of site complete) of light as required at site) complete all as specified and directed. Make - Luker Cat Part No : LNPR15 or equivalent make inCG/ Philips/ Havells. |
| 108 | All as per item sl No 101 above but,12 watt |
| 109 | All as per item sl No 101 above but,9 watt |
| 110 | S & F of 18 watts surface mounted LED light fitting , white/yellow colour as reuired as sitewith slim high perfomanance surfaced mounted LED light fittings, round/square shape as required at site made from die-cast aluminium and CRCA covering, powder coated in white colour complete all as specified and directed. MAKE: Luker model no -LNPSRR18N or equivalent make of Havells/ CG/ Philips |