| 1 | Material and labour for point wiring for one light/fan/call bell point with 1.5 sqmmPVC insulated (FR-LSH) unsheathed copper multistranded conductor cable 1100 volts grade controlled by one way switch including 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper multistrand conductor cable 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC casing caping with all accessories and sunk cast pressed steel terminal box made out of MS sheet 1.25mm thick with 3mm thick hylum laminated/bakalite sheet cover for mounting switch, socket, fan regulator,etc after and including taking down of old existing point wiring including fixtures and fittings such as switch, ceiling rose, holders, socket, etc and making good the distrubed surfaces as per the existing complete all as specified and as directed by the Engr-in-Charge. Note: Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. |
| 2 | All as per item No 1 here-in-before but for 3 pin 6 Ampssocket out let on the same board with 1.5 sqmm cable complete all as specified and as directed by the Engr-in-Charge. |
| 3 | All as per item No 1 here-in-before but for 5 pin 6 Amps switch socket combination on the independent board with 1.5 sqmm cable complete all as specified and as directed by the Engr-in-Charge. |
| 4 | All as per item No 1 here-in-before but for one 5 pin 6/16 Amps switch socket combination on independent board with 2.5 Sqmm PVC insulated unsheathed copper cable multistrand conductor 1100 volts grade and 2.5 sqmmcopper conductor cable as earth continuity conductorcomplete all as specified and as directed by the Engr-in-Charge. |
| 5 | S&F as in repair Switch piano, flush type single pole, one way 6 Amp complete all as specified and as directed by the Engr-in-Charge. |
| 6 | S&F as in repair Socket outlet,3 pin 6 amp flush type complete all as specified and as directed by the Engr-in-Charge. |
| 7 | Supply and fix as in repair Switch socket combination 2in 1, 6 Amp flush type universal complete all as specified and as directed by the Engr-in-Charge. |
| 8 | Supply and fix as in repair Switch socket combination 2in 1, 3 pin, 6 and 16 Amp flush type universal complete all as specified and as directed by the Engr-in-Charge. |
| 9 | Supply and fix as in repair bell ding dong AC 230 volts, single polecomplete all as specified and as directed by the Engr-in-Charge. |
| 10 | Supply and fix as in repair Bell push, flush type, 5 amp complete all as specified and as directed by the Engr-in-Charge. |
| 11 | Supply and fix as in repair ceiling rose surface bakelite three terminal65 x 50mm complete all as specified and as directed by the Engr-in-Charge. |
| 12 | S&F as in repair batton/ Angle holder insulated body with back plate suitable to batton fiting complete all as specified and as directed by the Engr-in-Charge. |
| 13 | S & F as in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed by the Engr in-Charge. |
| 14 | .Supply and fixing as in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCBcomplete all as specified and as directed by the Engr-in-Charge. |
| 15 | Supply and fix as in repair PVC rectangular block with 3mm thick industrial plastic laminated sheet duly cut for fixing switch,socket, fan regulator etc of the following size complete all as specified and directed. |
| 16 | (a) Size 10cm x 10cm x 5cm. |
| 17 | (b) Size 25cm x 20 cm x 5 cm. |
| 18 | Supply and fixing as in repair LED light fittings 1x20 W ,220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by the Engr-in-Charge. |
| 19 | Supply and fixing as in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by the Engr-in-Charge. |
| 20 | Supply and fixing as in repair round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by the Engr-in-Charge. |
| 21 | Supply and fixing as in repair MCB DB TPN 4 ways double door with 200 Amps rated bus bar neutral link, earth bar and din rail,recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed by the Engr-in-rge. |
| 22 | Supply and fixing as in repair MCB DB SPN 12 ways double door with 200 Amps rated bus bar neutral link, earth bar and din rail,recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed by the Engr-in-Charge. |
| 23 | Supply and fixing as in repair MCB DB SPN 8 ways double door with 200 Amps rated bus bar neutral link, earth bar and din rail,recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed by the Engr-in-Charge. |
| 24 | Supply and fixing as in repair MCB DB SPN 4 ways double door, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed by the Engr-in-Charge. |
| 25 | Supply and fixing in repair MCB 40 - 63 Amps, TPN, 240 Volt \"C\" series, breaking capacity 10 KA complete all as specified and as directed by the Engr-in-Charge. |
| 26 | Supply and fixing in repair MCB 40 - 63 Amps, SPN, 240 Volt \"C\" series, breaking capacity 10 KA complete all as specified and as directed by the Engr-in-Charge. |
| 27 | Supply and fixing in repair MCB 06 - 32 Amps, SPN, 240 Volt \"C\" series, breaking capacity 10 KA complete all as specified and as directed by the Engr-in-Charge. |
| 28 | Supply and fixing as in repair MCB 6 to 32 Amps, single pole, 240 Volt \"C\" series, breaking capacity 10 KA complete all as specified and as directed by the Engr-in-Charge. |
| 29 | Supply and fix sub-main wiring for main DB\"s to Sub DB\"s with PVC insulated & unsheathed two run of 4 Sqmm single core multi stranded copper conductor cable (FRLS), 1100 Volt grade alongwith one run of4 Sqmm PVC insulated & unsheathed copper conductor cable (FRLS), 1100 Volt grade, connected to common earth dolly asearth continuity conductor, drawn through PVC casing caping and including taking down existing one complete all as specified and as directed by the Engr-in-Charge. Note : Three runs of 4 Sqmm cable shall measured as one length. |
| 30 | Taking down ceiling fan of any type, any make andany sweep from its position for repairing work, opening the body and blade, checking for repalcement of unserviceable spares, cleaning, overhauling & greasing, replacement of unserviceable spare by new one, re-assembling of all the components, testing and hanging it up in its original position, complete all as specified and as directed by the Engr-in-Charge.Note : New spare parts required for replacement shall be measured and paid seperately. |
| 31 | Supply only MS split pin size 2 \" x 1/8 \"forceiling fan of 1200/1400mm Sweep complete all as specified and as directed by the Engr-in-Charge. |
| 32 | Supply onlyHanging bolt with nut of size 3/8\" x 3 1/2 \"forceiling fan of 1200/1400mm Sweep complete all as specified and as directed by theEngr-in-Charge Make : TATA or equivalent as per tender documents. |
| 33 | Supply onlyRubber bush of size 1 1/2 \" dia x 1\" thickforceiling fan of 1200/1400mm Sweep complete all as specified and as directed by the Engr-in-Charge. |
| 34 | Supply onlyBall bearing of size 6201/6202/6203 forceiling fan of 1200/1400mm Sweep complete all as specified and as directed by the Engr-in-Charge. Make : TATA/SKF or equivalent as per tender documents. |
| 35 | Supply onlyGun Metal bushing for ceiling fan of 1200/1400mm Sweep complete all as specified and as directed by the Engr-in-Charge. Make : TATA/SKF or equivalent as per tender documents. |
| 36 | S&F forstandardbladefixingwithscrewssuitabletoceilingfan1200mm Sweep,after taking downoldexisting unserviceable, complete all as specified and as directed by the Engr-in-Charge. |
| 37 | S&F for down rod of 1.5\" height fabricated out of MS pipe 12 mm dia heavy duty painted with brown paint suitable to ceiling fan of any description make brand and model after taking down old existing unserviceable down rod complete all as specified and as directed by the Engr-in-Charge. |
| 38 | S&F hanging hook \"S\" type suitable for ceiling fan of any capacityincluding taking down old unserviceable ones, complete all as specified and as directed by the Engr-in-Charge. |
| 39 | Supply and fixing as in repair2.5 mfd capacitor complete all as specified and as directed by the Engr-in-Charge. |
| 40 | Supply and fixing as in repair3.5 mfd capacitor complete all as specified and as directed by the Engr-in-Charge. |
| 41 | Taking down exhaust fan of any type, any make andany sweep from its position for repairing work, opening the body and blade, checking for repalcement of unserviceable spares, cleaning, overhauling & greasing, replacement of unserviceable spare by new one, re-assembling of all the components, testing and hanging it up in its original position, complete all as specified and as directed by the Engr-in-Charge. Note : New spare parts required for replacement shall be measured and paid seperately. |
| 42 | Supply only Ball bearing 2001/ 2002/ 2003for exhaust fanscomplete all as specified and as directed by the Engr-in-Charge. Make : TATA/SKF or equivalent as per tender documents. |
| 43 | Supply only Metal bush bearingfor exhaust fanscomplete all as specified and as directed by the Engr-in-Charge. Make : TATA/SKF or equivalent as per tender documents. |
| 44 | Supply and fixing asin repair M.S. galvanised louvers suitable for exhust fan of size 300mm to 450mm sweepcomplete all as specified and as directed by the Engr-in-Charge. |
| 45 | Material and labour for painting of ceiling fan of size 1200mm/ 1400mm sweep with down rodby spray painting with two coats of synthetic enamel paintafter preparation old painted surface by scraping/ removing old paint by emery paper including writing of MES No complete all as specified and as directed by the Engr-in-Charge. |
| 46 | Taking down wall mounted Geyser of Capacity 25/50 ltrs by disconnection electric supply, water connectionsfrom single/Married/OTM Accns messes, billets, cafeteria etc., and dismantling the Geyser, descaling of silt deposited /cleaning of inner tank ofgeyser 25/50 Ltrs capacity including washing with clean water, checking the spare parts, re-assemblingand testing after fixing of new spare parts and refixing after repairs/maint work the same to its original place after necessary testing, complete all as specified and as directed by the Engr-in-Charge.Note:- Replacement of old spare parts are measured and paid separately under relevant items here-in-after as supply only rates and fixing charges for spare parts shall deemed to be inclusive in the quoted rates) |
| 47 | Supply only in repair for apparatus plate suitable for water storage heater of 25 / 50 ltrs capacity complete all as specified and as directed by the Engr-in-Charge. |
| 48 | Supply only in repair for heating elements of 1.5 KW 230 V suitable for water heater ofany type includingconnection with suitable cable complete all as specified and as directed by the Engr-in-Charge. |
| 49 | Supply only in repair for heating elements of 2 KW 230 V suitable for water heater ofany type includingconnection with suitable cable complete all as specified and as directed by the Engr-in-Charge. |
| 50 | Supply only in repair for thermostat switch of geyser 230 V, 30 degree to 90 degree centigradetemp range to be set at 70 degree to50 degreecenti grade suitable for water heater complete all as specified and as directed by the Engr-in-Charge. |
| 51 | Supply and fixing as in repairfor bottom cover,made out of MS sheet 16 guage, duly paintedwith two coats of white synthetic enamel paint both side over a coat of red oxide zinc chrome primer for 25/50 Ltr capacity geyser complete all as specified and as directed by the Engr-in-Charge. |
| 52 | Supply and fixing as in repair for top covermade out of MS sheet 16 guage, duly painted with two coats of white synthetic enamel paint both side over a coat of red oxide zinc chrome primer of 25/50 Ltr capacity geyser complete all as specified and as directed by the Engr-in-Charge. |
| 53 | Supply and fixing as in repair for 450mm long brass CP braided hoses with 2 nuts without nipple suitable for geysers complete all as specified and as directed by the Engr-in-Charge.Make : Jaguar Cat No 805B or equivalent as per tender documents. |
| 54 | Supply and fixing as in repair for PVC inlet connector pipe for geyser, heavy duty, with brass coupling both ends to fix inlet of geyser complete all as specified and as directed by the Engr-in-Charge..Make : Prayag/Polytuf or equivalent as per tender documents. |
| 55 | Material and labour for preparation of geysers outer body surfaces and painting one coat of synthetic enameled paint by spraying to geysers and writing MES No. on geyser in block letter not less than 5 mm wide and 25 mm high with black paint for 25 lit capacityof geysers complete all as specified and as directed by the Engr-in-Charge. |