| 1 | Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concretebut excluding ashlar facings, dressed stonework and precast concrete articles complete all as specifed and as directed by Engineer in Charge. |
| 2 | Demolition Concrete of any description and in any position not otherwise specifically provided for complete all as specifed and as directed by Engineer in Charge. |
| 3 | Material & Labour for Excavating over areas, n exc 1.5m deep and getting out in any type of soil complete all as specifed and as directed by Engineer in Charge. |
| 4 | Material & Labour for Excavation in trenches not exc. 1.5 m wide and notexceeding 1.5m depth for foundation of poles/laying of cables/stay/strut etc not exceeding 10 Sq m on planand getting out in soft/loose soil complete all as specifed and as directed by Engineer in Charge. |
| 5 | Material & Labour for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified & directed by Engr-in-Charge. |
| 6 | Material & Labour for Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified & directed by Engr-in-Charge. |
| 7 | Material & Labour forPCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) in mass concrete and foundation complete all as specifed and as directed by Engineer in Charge. |
| 8 | Material & Labour for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finished surface of concrete complete all as specifed and as directed by Engineer in Charge. |
| 9 | Material & Labour for Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specifed and as directed by Engineer in Charge. |
| 10 | Material & Labour forformworktoedges of concrete flats, treads, breaks in floors, window cills, concrete raillings , opening in concrete walls, floors and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, hozontal or sloping and similar work exc 5cm but n exc 10cm etc.for fair finished surface complete all as specified and directed by Engineer in Charge. |
| 11 | Material & Labour for Reinforced cement concrete Type B1 1:2:4 (20 mm graded aggregate) (nominal mix) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concreteetc complete all as specified and directed by Engineer-in-Charge. |
| 12 | Material & Labour for Reinforced cement concrete Type B1 1:2:4 (20 mm graded aggregate) (nominal mix) inColumns,pillars,piers,posts and struts etc complete all as specified and directed by Engineer-in-Charge. |
| 13 | Material & Labour for Reinforced cement concrete Type B1 1:2:4 (20 mm graded aggregate) (nominal mix) inBeams, cantilevers, bressummers, lintels over 1.5m span, chajjaetc complete all as specified and directed by Engineer-in-Charge. |
| 14 | Material & Labour for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge. |
| 15 | Material & Labour for Mild steel TMTbars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and directed by Engineer-in-Charge. |
| 16 | Supply & Fix mild steel work such as in angle iron, flat iron fillets etc for horn, fixing of barbed wire to RCC post, securing wire mesh etc. including all necessary cuttings, drilling, bolting or riveting etc and including 10mm MS bars as in tie bars fixed to fencing posts including necessary welding where required, as per site requirement and other similar works complete, conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer in Charge. |
| 17 | Material & Labour for 0.63mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed by Engineer in Charge. |
| 18 | Material & Labour for Writing letters or figures (Block. Roman, Italic or Indian) exc. 30 cm but not exc 60 cm high on gate board etc complete all as specified and directed by Engineer-in-Charge. |
| 19 | Material & Labour for Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed by Engineer-in-Charge. (Each line wire to be measured) |
| 20 | Material & Labour for painting to new or previously untreated steel surfaces of any description over 10 cm in width or girth with two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete all as specified and directed by Engineer-in-Charge. |
| 21 | Providing & fixing concertina coil fencing with punched tape concertina coil 600 mm dia having 50 nos turns and approximate weight 8.00 Kg ( + 5%) and coil be streached to cover a distance 6.0 RM per coil and fixed in \"Y\" shaped angle iron over wall of height upto 3.00 m complete all as specified & directed by Engr-in-Charge. |
| 22 | Material & Labour for Brickwork with fly ash modular bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge. |
| 23 | Material & Labour for rendering 15mm thick on cement mortar 1:4finished fair faces of brick/concrete surfaces complete all as specified & directed by Engineer-in-Charge. |
| 24 | Material & Labour for rendering 15mm thick on cement mortar 1:4finished surface other than fair face of brick-work or on one side of lathing complete all as specified & directed by Engineer-in-Charge. |
| 25 | Material & Labour for preparation of new plastered surfaces and applying two coats ofcement base paint of approved shade on walls all as specified & directed by Engineer-in-Charge. |
| 26 | Supply & Fix PVC (SWR) pipe 110 mm bore, single socketed, inany length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge. |
| 27 | Material & Labour for expansion Joint using 20mm tkick Premoulded bituminous joint filler in wall complete all as specified and directed by Engineer in Charge. |
| 28 | Material & Labour for providing and fixing stainless steel (Grade 304) gates, railing made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed by Engineer in Charge. |
| 29 | Supply & Fix granite18-20mm thick of any type (table rubbed and polished) in steps, jambs pillars, window cill, cooking platform and like in cement mortar 1:4 including pointing in white cement complete all as specified and ditected by Engineer in Charge. |
| 30 | Material & Labour for Mirror polishing on marble/ granite/Kota stone/ stone work where ever required to give high gloss finish complete all as specified and ditected by Engineer in Charge. |
| 31 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core complete all as specified and directed by Engineer-in-charge. |
| 32 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and directed by Engineer-in-charge. |
| 33 | Material & Labour for providing river sand as in sand cushioning to under ground cable including punning down of sand in layers complete all as specified and directed by Engineer-in-charge. |
| 34 | Supplying and laying reinforced precast concrete cable cover LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and as directed by Engineer in Charge. |
| 35 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-charge. |
| 36 | Supply and fix steel tubular swaged poles type 410 SP-22 (8.5 meter long) complete with CI base plate and finial including foundation and coping complete all as specified and directed by Engineer-in-charge. |
| 37 | Material & Labour for PCC (1:4:8) type D2 with 40 mm gradded stone aggregate for foundation of poles/stay assemblyor mass filling complete all as specified and directed by Engineer-in-charge. |
| 38 | Material & Labour for PCC (1:3:6) type C2 with 40 mm gradded stone aggregate for foundation of poles/stay assemblyor mass filling complete all as specified and directed by Engineer-in-charge. |
| 39 | Material & Labour for PCC (1:2:4) type B2 with 40 mm gradded stone aggregate for copping ofpolesor mass filling complete all as specified and directed by Engineer-in-charge. |
| 40 | Supply & Fix in replacement street light GI pipe bracket 40 mm dia 1.50 metre length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc complete all as specified and directed by Engineer in Charge. |
| 41 | Supply, installing, testing and commissioning factory madeLT feeder pillar box Outdoor type platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA MS sheet with frontopeningtype with double door shutter and locking arrangement (including provn oflock with 2 keys), powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surfacewith TPN aluminium bus bar of rating not less than 200Amps including 1 No MCB SPN 06 Amps on suitable foundation complete all as specified and directed by Engineer-in-Charge. |
| 42 | Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engineer-in-charge. |
| 43 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 2 core complete all as specified and directed by Engineer-in-charge. |
| 44 | Supply & Fix MCB DB SPN 4 Way factory made IP 43 protection class metal double doorwith 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed by Engineer-in-charge. |
| 45 | Supply & Fix MCBs240/415 Volts 10 KA finger proof terminal, B curve bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB. (DB will be measured and paid separately under respective items of sch A):- |
| 46 | MCB SPN 40 Amps |
| 47 | MCB SP 6 to 32 Amps |
| 48 | Material & Labour for submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked25mm dia as per IS specification fixed concealedin wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly complete all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site by Engineer in Charge. Note: Two runs of 4 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathedcopper conductor as earth wire, conduitand conduit accessories will be measured as one length. |
| 49 | Supply, Installation and Commissioning of LED Name board of \"PM SHRI KENDRIYA VIDYALAYA NO 3 AFS, BHISIANA BATHINDA \"with selected monogram of ACP sheet for board and background colour as selected and LED acrylic letters in white colour of 1.5 watt & LED driver of Hilite or equivalent make and size of board 20`x 5`incuding Material and labour for supports frame / clamp and back plate fabricated from MS square pipe of size 75x75mm for standing of board for leg purpose including nuts , bolts washers, welding bending cold or hot drilling holes for bolt in any shape of size as indicated or directed and inclusive of one primer coat , one under coat and one finishing ofcoat of paint complete all as specified and directed. Including cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in coping etc complete including point wiring with 1.5 sqmm FR PVC insulatedcable multistranded coppper conductor drawnthrough & including ISI marked PVC conduits including 5 Amp switch & socket, box mudular type all as specified and allas directed by Engineer in Charge. |