| 1 | Taking down cement or cement lime plaster on walls/ concrete/roof slab any description including racking out joints hacking for key, scrubbing down with water etc. and removing rubbish complete all as specified and directed. |
| 2 | Providing and applying 10 mm thick ready mix cement plaster on fair faces of brick wall or concrete surface including finishing the surface fair and even complete all as specified and directed. |
| 3 | M&L for applying one coat of alkali resistant primer on plasteredsurfaces of wall over 1.5 mm thick wall care putty and applying two coat of oil bound distemper including preparation of new surfaces complete all as specified and directed. |
| 4 | Providing and applying 15 mm thick ready mix external sand faced cement plaster with neat cement rendering at all locations in two coats on masonry (except stone masonry) and concrete surfaces with and including mixing water proofing compound to the first coat of plaster as per manufacturers specification, racking out joints, hacking of concrete surface, finishing, curing, scaffolding etc complete all as specified & directed. |
| 5 | M&L for preparation of new surface of wall/chajja/ roof projection etc. and applying two coats of PU & Acrylic based Elostomeric coat in UV shade having OVOC over a coat of alkali resistant primer complete all as specified and directed. |
| 6 | Providing and applying 20 mm thick ready mix external sand faced cement plaster with neat cement rendering at all locations in two coats on masonry (except stone masonry) and concrete surfaces with and including mixing water proofing compound to the first coat of plaster as per manufacturers specification, racking out joints, hacking of concrete surface, finishing, curing, scaffolding etc complete all as specified & directed. |
| 7 | M&L for applying a coat of SmartCare Primero with dilution ratio of 1:1 with water maintain a coverage of 100 sq.ft/ltr cleaning off the dust, dirt etc. and filling cracks with smart crack filler mixed with cement in 1:3 on walls complete all as specified & directed. |
| 8 | M&L for preperation of new surface wall/ceilling by scrapping/ rubbing, applying two coat of advanced anti-algal weather proof 100% acrylic smooth emulsion with silicon additives, over a coat of fibre reinforced elastomeric liquid water proofing membrane (Asian paint damp proof + ultima suprema, exterior anti fungal paint or equivalent), including making proper surface by applying ready mix preparatory wall care putty wherever required complete all as manufacturers instructions and as directed. Note:- The application of paint shall be done by the authorized applicator of the company and also the dealer/company shall appoint a person to inspect and validate the application of emulsion in stage wise manner. |
| 9 | Chipping off existing loose, damaged concrete from RCC members of all affected RCC Columns, beams, slabs and chajjas on external and internal facades etc beyond main r/f.(if required in the opinion of the consultant), carefully with chisel and hammer including relieving structural members such as column, beam and slabs of their superimposed load partially or fully by provision of adjustable steel props, frames etc. Providing and applying \"Rusticide SS\" Rust passivator or equivalent as specified in the Brand names to existing r/f bars including wire brushing of r/f, cleaning, washing of concrete etc complete as directed. Providing and applying two coats of rust preventor slurry made out of \"Polyalk Fixoprime\" or equivalent as specified in the brand names and cement in proportion 1:1.5 to exising r/f bars as directed complete. Providing and applying bonding coat of slurry made out of \"Polyalk EP\" or equivalent as specified in the brand names and cement in proportion 1:1 to concrete and r/f substrates complete as directed. Providing and applying \"Polyalk EP\" or equivalent as specified in the brand names. Polymer modified cement mortar in required porportion (1:5:15) to RCC members including hand packing, curing and making the surface rough for plastering complete all as specified and directed. |
| 10 | M&L for rendering 5 mm thick on ceiling in cement mortar 1:3including finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 11 | M&L for applying 1.5 mm thick putty and applying two coat of oil bound distemper over a coat of alkali resistant primerincluding preparation of new surfaces complete all as specified and directed. |
| 12 | M&L for preperation of old surface wall/ceilling by scrapping/ rubbing, applying two coat of advanced anti-algal weather proof 100% acrylic smooth emulsion with silicon additives, over a coat of fibre reinforced elastomeric liquid water proofing membrane (Asian paint damp proof + ultima suprema, exterior anti fungal paint or equivalent), including making proper surface by applying ready mix preparatory wall care putty wherever required complete all as manufacturers instructions and as directed. Note:- The application of paint shall be done by the authorized applicator of the company and also the dealer/company shall appoint a person to inspect and validate the application of emulsion in stage wise manner. |
| 13 | Providing and laying Super fluid microconcrete-Roffe crete (or equivalent as specified in the list of brand names) for repairs in beam bottoms, columns, slabs etc. including mixing with 5 mm to 10 mm size aggregates, water proof plywood/steel plate shuttering, pouring, tamping, consolidating, curing etc complete as per manufacturer\"s specification and all as directed. |
| 14 | M&L for preparation of old surface of wall and applying one coat of oil bound distemper complete all as specified and directed. |
| 15 | M&L for preparation of old surface of ceiling and applying one coat of oil bound distemper complete all as specified and directed. |
| 16 | M&L complete removal of existing treatment of wall and applying 1.5 mm thick wall care putty incl preparation of old surfaces and applying two coats of oil bound distemper over one coat of alkali resistant primer complete all as specified and directed. |
| 17 | M&L for complete removal of existing treatment of ceiling and applying 1.5 mm thick putty and applying two coat of oil bound distemper including preparation of surfaces over one coat of alkali resistant primer complete all as specified and directed. |
| 18 | M&L for preparation of old painted surfaces of wood or wood based materials of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed. |
| 19 | M&L for preparation of old painted steel, surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed. |
| 20 | M&L for prepration of old surfaces of wall/ceiling/chajja and applying one coats of exterior emulsion paint, white or tinted complete all as specified and directed. |
| 21 | Dismantling floor, hearth or wall tiling including cement mortar bedding (including backing), removing tiles and rubbish off the premises complete all as specified and directed. |
| 22 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square or rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed. |
| 23 | M&L for glazed ceramic coloured tiles of size 450 x 350 x 7 mm thick in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing surface with & including rendering 10 mm thick in cement mortar 1:3 finished rough to fix tiles complete all as specified and directed. |
| 24 | M&L for light shade vitrified ceramic coloured tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed. |
| 25 | M&L for applying bitumen blown any grade, applied hot, one coat to concrete surfaces at the rate of 1.5 kg/Sqm complete all as specified and directed. |
| 26 | M&L for providing polythelene film , 50 micron thick, laid on a coat of bitumen primer @ 0.30 to 0.50 kg per sqm complete all as specified and directed. |
| 27 | M&L for plain cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in filling in sunken floor and the like including demolition of existing concrete complete all as specified and directed. |
| 28 | S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet,integral foot rest and providing lime concrete bedding and connecting to flusing cistern complete all as specified and directed. |
| 29 | S&F in repair plastic water closet sheet covers white closed pattern with flat bottom, with mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 30 | S&F in repair 10 ltr PVC valveless, syphonic action type, flushing cistern, low level, white, with intel, ball valve, float and handle including brackets complete all as specified and directed |
| 31 | S&F in repair PVC connection 450 mm long suitable for 15 mm GI pipe with two PTMT nuts & rubber washers complete all as specified and directed. |
| 32 | S&F in repair vitreous china wash hand basin, white,flat back 550 x 400 mm excluding tap but including brackets 2 numbers including cutting for and pinning in ends of brackets, 32 mm CP brass waste coupling with long screwed shanks and fly-nuts, flange end bedded in red lead cement complete all as specified and directed. |
| 33 | S&F in repair Viterous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed. |
| 34 | Cleaning and removing all scale and dirt, etc, with bleaching power, brushfrom mouths of circulating pipes etc capacityexc 250 and not exc 500 Ltr each including write date of cleaning and next due date complete all as specified and directed.Note :- Each tank will be cleaned after six months and will be measured seperately each time. |
| 35 | Cleaning and removing all scale and dirt, etc, with bleaching power, brushfrom mouths of circulating pipes etc capacityexc 500 and not exc 1000 Ltr each including write date of cleaning and next due date complete all as specified and directed.Note :- Each tank will be cleaned after six months and will be measured seperately each time. |
| 36 | S&F in repair CP wall mixer, for mixing hot and cold water fancy type cast copperalloy, with capstan heads, chromium plated, screwed down for 15 mm bore pipe, high pressure with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed. |
| 37 | S & F in repair stop valve/angle valve 15 mm nominal bore cast copper alloy, fancy type, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified and directed. |
| 38 | S&F in repair two way stop valve/angle valve 15 mm nominal bore cast copper alloy, fancy type, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified and directed. |
| 39 | S&F in repair long body bib taps, cast copper alloy, fancy type, chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule orto GI socket complete all as specified and directed. |
| 40 | S&F in repair pillar taps, long nose, cast copper alloy, with capston heads, fancytype, chromium plated, screwed down high pressure with or without lettered \"Hot\" or \"cold\" with long screwed shanks and flynuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed. |
| 41 | S&F in repair chromium plated health faucet, telephonic type with CP flexible arms and jet of approved make, suitable for 15 mm bore iron pipes or for unions and fixed complete all as specified and directed. Make:- Jaquar, Cat Part No. 573 or equivalent. |
| 42 | S&F in repair chromium plated brass shower roses 125mm dia with or without swival joints, including fixing to 15 mm dia pipe or union all as specified. |
| 43 | S&F in repair 20 mm dia brass chromium plated tubular towel rail, D type, 90 cm long between flanges fixed with rawl plug completeall as specified and directed. |
| 44 | S&F in repair toilet paper holder, CP box type fixed to wall with chromium plated brass screws and rawl plugs complete all as specified and directed. |
| 45 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends for concealed water tubing and making good, cutting not exceeding 10 cm girth as in brick wall,concrete block or slab complete all as specified and directed. |
| 46 | S&F in repair 32 mm bore low density polyethylene pipes(LDPE) of pressure rating 6 Kgf/cm2 fixed to WHB and sink complete all as specified and directed. |
| 47 | S&F in repair grating doom 100 mm dia of PTMT minimum weight not less than 25 grams complete all as specified and directed. |
| 48 | S&F in repair 600mm x 450 mm x 5.5 mm thick edge less mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and aluminium angle alround fixed to wooden plugs with chromium plated brass screws & washers complete all as specified and directed. |
| 49 | Demolition of cement concrete unreinforced in ground floors and pavings n.exc. 15 Cm thickness (below or above ground level) complete all as specified and directed. |
| 50 | M&L for chequered cement concrete tiles 200 x 200 x 25 mm thick set jointed and pointed in neat coment slurry in floors with grey cement and pigment with & including screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed. |
| 51 | M&L For Exterior/ parking floor tiles heavy duty for light traffic, non skid, anti scratch, heavy grip vitreous/ semi vitreous coloured, unique design tiles of size 300 x 300 x 8 to 10 mm thick each as in floor, steps, risers, landing, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed.Make:- Duracrete, Durato, RAK, Bell, H&R Johnson |
| 52 | Taking down existing roof treatment of any type with PCC padding, cleaning of roof top by brooming down with steel wire brush, scrapping down with steel scrapper and roughening surfaces of old roof and washing down with water to remove dust etc. complete all as directed.NOTE:- Debries shall be removed outside Defence land without any extra cost to the Govt. complete all as directed. |
| 53 | Filling and reinstating of separation cracks: Opening the separation cracks at the junction of RCC and masonry where ever directed and instructed into \"V\" Grooves 2 to 3\" from either side of the cracks by carefully marking areas to be opened up using a cutting machine and skillfully/carefully chiseling with a well sharpened chisel and hammer as directed including wire brushing and washing of concrete substrata and masonry walls with water jet to the surfaces thus prepared to the entire satisfaction of the consultant as instructed and directed. Moistening the cracks, provinding and applying priming/bonding coat of slurry made out of \"Polyalk EP\" and cement (or equivalent as specified in the list of brand names) in proporiton 1:1 to surfaces prepared as instructed and directed. Filling the cracks/grooves by providing and applying \"Polyalk EP\" Polymer modified cement mortar (or equivalent as specified in the list of brand names) in proporiton 1:5:15 (Polyalk EP: Cement: Graded Sand/Quartz Sand) on the prepared surfaces and finishing it in the level with the existing plaster including hand packing, curing and making the surface similar to the external plastering using wooden floats/punch etc. complete all as specified and directed. |
| 54 | M&L for PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in as in padding over roof for levelling/making proper slope mixed with liquid water proofing compound as per manufacture instructions including necessary form work complete all as specified and directed.NOTE:- Water proofing compound shall be measured and paid seperately |
| 55 | M&L for rendering/screeding 15 mm thick on roof slab in cement mortar 1:3 mixed with liquid WPC @ 200 ml per bag of cement finished fair and even complete all as specified and directed.Note:- WPC shall be measured and paid seperately |
| 56 | Supply only liquid water proofing compound |
| 57 | M&L for laying water proofing treatment using 4 mm thick APP modified membrane consisting five layers membrances with features as specified weighing not less than 3.50 kg per sqm reinforced with non woven polyester fiber @ 160 gm/Sqm laid over a coat of cold applied bituminous primer @ 0.40 kg/sqm by torching the membrance and sealing the over lap by 100 mm length side and 150 mm width side all as per manufacturer instructions including joints and changes in direction be curved with cement mortar 1:3 mixed with SBR latex @ 200 ml/bag of cement curved well before laying membrance and applying two finishing coats of solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm (each coat) complete all as specified and directedNote: (i) Irrespective of lap the net covered area will only be measured for payment. (ii) Rate is inclusive of APP membrane, SBR Latex, primer, aluminium paint etc. |
| 58 | Supplying and applying High build elastomeric waterproofing coating based on pure, hydrophobic polyurethane, cold applied of spray / brush applied, membrane with an elongation of 550% and tensile strength of 2.5 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm as per ASTM C1305, no leakage upto 7 bars of water pressure as per DIN 1048, shore A Hardness of min. 45 as per ASTM D 2240. The system includes final base preparation, water based primer and applying SmartCare PU Magnum or approved equivalent in two to three coats to achieve a min. thickness of 1.2 mm, etc. complete as per Manufacturere specifications and as directed. |
| 59 | Cutting down the plants/ trees of girth n.exc. 15 cm from roof tops/ sides of external walls of building, chajja, wall junctions & at junctions of rain water/ waste water pipes including taking out the roots entered into wall/ slab surfaces, making good surfaces with PCC 1:2:4 type B-0 or cement mortar (1:2) including repairing the GI/ CI/ PVC pipe joints which were affected due to cutting/ taking out process after applying suitable herbicide including making good the disturbed surfaces to match the adjoining surfaces complete with necessary scaffolding/ staging/ Jhula etc, with all necessary safety precautions complete all as directed and as specified. |
| 60 | S&F in repair Glass shelf with CP railing (22 x 6\") complete all as directedMake:- Nixo-Cat part no- ES01A/Hilife/Cera/Prayag |
| 61 | S&F in repair, Glass corner shelf with CP railing(12\" x 12\") complete all as directedMake-Nixo-Cat no-ES03A/Hilife/Cera/Prayag |
| 62 | Disconnecting existing water tank of capacity exc. 250 ltr but not exc. 500 ltr, setting aside (or lowering of required) for repairs to roofs etc. and hoisting if required reconnecting and refixing in position on roof complete all as specified and directed. |
| 63 | Disconnecting existing water tank of capacity exc. 500 ltr but not exc. 1000 ltr, setting aside (or lowering of required) for repairs to roofs etc. and hoisting if required reconnecting and refixing in position on roof complete all as specified and directed. |
| 64 | Dismantling water tank capacity exc. 500 ltr but n.exc. 1000 ltr complete all as specified and directed. |
| 65 | Dismantling water tank capacity exc. 250 ltr but n.exc. 500 ltr complete all as specified and directed. |
| 66 | S&F in position rotational moulded polyethylene water storage tanks 1000 lts capacity (cylinderical verticalwith closed top) hoisted and fixed in position all as specified in SSR Part I complete all as directed |
| 67 | S&F in position rotational moulded polyethylene water storage tanks 500 lts capacity (cylinderical verticalwith closed top) hoisted and fixed in position all as specified in SSR Part I complete all as directed |
| 68 | Taking up or down existing GI tubing and connections and refixing old steel tubing and connections in new or old position(walls, ceiling, floors, etc.) for 20 mm dia pipes with and including all new fittings including making good the disturbed surface complete all as specified and directed. |
| 69 | Taking up or down existing GI tubing and connections and refixing old steel tubing and connections in new or old position(walls, ceiling, floors, etc.) for 25 mm dia pipes with and including all new fittings including making good the disturbed surface complete all as specified and directed. |
| 70 | Supply, fixing, laying & testing CPVC pipes 20 mm outer dia SDR 11 including Plain CPVC SDR 11 fittings on walls/ceiling or laying in floorsincluding taking down existing pipe complete all as specified and directed. |
| 71 | Supply, fixing, laying & testing CPVC pipes 25 mm outer dia SDR 11 including Plain CPVC SDR 11 fittings on walls/ceiling or laying in floorsincluding taking down existing pipe complete all as specified and directed. |
| 72 | S&F in repair 20mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 73 | S&F in repair 25 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 74 | S&F in repair PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and fixed to walls complete all as specified and directed. |
| 75 | S&F in repair PVC (SWR) pipe 75 mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and laid in trenches or in floors complete all as specified and directed. |
| 76 | S&F PVC (SWR) bend 75 mm dia, any radius fixed to pipe complete all as required and as directed. |
| 77 | S&F PVC (SWR) bend 110 mm dia, any radius fixed to pipe complete all as required and as directed. |
| 78 | S&F in repair water tank covers of PVC suitable for 500/1000 Ltr tanks complete all as directed. |
| 79 | M&L for preparation of new or previously untreated steel surfaces exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed. |
| 80 | Taking down Chowkats or frames with shutter (without taking off shutters from the frame) n. exc. 1.50 sqm each complete all as specified and directed. |
| 81 | S&F solid PVC door frame of size 50mmx 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube and fixed with screws and rawl plugs complete all as specified and directed. |
| 82 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement complete all as specified and directed. |
| 83 | Taking down Chowkats or frames with shutter (without taking off shutters from the frame) exc. 1.50 sqm and n. exc. 4.00 sqm each complete all as specified and directed. |
| 84 | Taking down shutters of any descriptionexc 1 sqm & n. exc 2 sqmeach complete all as specified and directed |
| 85 | M&L for 2nd class hard wood plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed. |
| 86 | M&L for 35 mm thick, plain framed, panelled shutters (two panels), with lock rail and panels of 9 mm thick BWP commercial ply or 12 mm thick venered particle boardwith commercial veneering on both faces with rails and style of 2nd class hard wood. The size of rail and stile as per IS : 1003 (part I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 87 | M&L for 2nd class hard wood glazed and skeleton shutters 35 mm thick, factory made, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed. |
| 88 | S&F in repair aluminium anodised wire mesh of size 1.5 mm x 3 mm mesh, 20 Gauge thick in doors/window shutters complete all as specified and directed. |
| 89 | S&Faluminium anodised wire mesh of size 1.5 mm x 3 mm mesh, 20 Gauge thick in doors/window shutters complete all as specified and directed. |
| 90 | S&F aluminium anodised barrel tower bolt of extruded section 200 mm long and fixed complete all as specified and directed. |
| 91 | S&F 100 mm sizemild steel butt hinges, ISI marked, medium weight, cold rolled and fixed with screws/welded to frame complete all as specified and directed. |
| 92 | S&F extruded aluminium alloy handles, fabricated type, anodised 150 mm size completeall as specified and directed. |
| 93 | S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed allas specified and directed. |
| 94 | M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in hold fast etc. including necessary form work complete all as specified and directed. |
| 95 | M&L mild steel work as hold fasts and similar small articles conforming to Fe-290, Gde E-165 complete all as specified and directed. |
| 96 | M&L for preparation of new or previously untreated wooden surfaces exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed. |
| 97 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 98 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed. |
| 99 | S&F rolled mild steel in roof trusses(framed), trussed purlins, crane gantries, rails and fastenings, MS pipe for post and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe- 290(Gde E-165) complete all as specified and directed. |
| 100 | Dismantling of plain or corrugated steel sheeting, any gauge, thickess including Nainital or similar pattern roofs covering complete all as specified and directed. |
| 101 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 102 | S&F Pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, ridge, hip and vally gutters, fixed with self tapping screws as specified complete all as specified and directed. |
| 103 | M&L for 40 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in flooring finished rough to receive floor/screed complete all as specified and directed. |
| 104 | Demolition of un reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 105 | Removing building materials by truck or tractor with using of if necessary JCB machine and trolly load min 5.00 Cum each load including loading, unloading and stacking at the destination and depositing out side defence land complete all as specified and directed. |