Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-Charge. |
| 2 | Material & labour for 25mm thick cement concrete type BO 1:2:4 using 12.5mm graded stone aggregate as in sub base floors complete all as specified and directed by Engr-in-Charge. |
| 3 | Material & labour for mat finish coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-Charge. |
| 4 | All as per item 3.00 above but on vertical surfaces such as in skirting and dados laid over and including 10 mm thick plaster in CM 1:4 complete all as specified and directed by Engr-in-Charge. |
| 5 | Material & labour for non skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-Charge. |
| 6 | Material & labour for glazed ceramic coloured tiles in vertical surfaces such as in skirting and dados 350x250x7mm/450x350x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10 mm thick plaster in CM 1:4 complete all as specified and directed by Engr-in-Charge. |
| 7 | Material & labour for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engr-in-Charge. |
| 8 | Supply & fix in repairs 25mm bore stainless steel heavy duty draphery rods (curtain rod) including all fittings and fixers cut to length and fix in position including decorative type fimals (bracket) colored finish of approved pattern complete all as specified and directed by Engineer-in-Charge. |
| 9 | Demolitionof reinforced cement concrete of any description and any position not otherwise specifically provided for complete all as specified and as directed byEngineer-in-Charge. |
| 10 | Removing building materials etc (other than spoil payable under item No 03028 to 03031 in Section 3 earthwork of SSR Part II) to a distance exceeding 1.0 Km but not exceeding 1.5 Km beyond the lead included in the rates, incluing loaing, unloaing and stacking at the destination complete all as specified and directed by Engineer-in-charge.(Note one metric tonne shall mean one load Refer preamble of SSR item No 21055) . |
| 11 | Taking down cement plaster on brick or stone walls or PCC block walling or RCC surface, ceiling including raking out joints hacking for key scrubbingdown with water etc complete all as specified and directed by Engineer-in-charge. |
| 12 | Material & labour for 5 mm thick rendering on repaired or fair faces of concrete surfaces on ceiling in CM 1:3 for fair finished surfaces complete all as specified and directed by Engr-in-Charge. |
| 13 | Material & labour for rendering 10mm thickon brick work, PCC block work, stone walls, concrete surface in cement mortar 1:6 finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 14 | Material & labour for rendering 15mm thick in CM 1:4 with water proofing compound @3% by wt of cement on repaired or fair faces of brick work or concrete work or PCC block walls or stone walls, finished even and fair complete all as specified and as directed byEngineer-in-Charge. Note : WPC will be measured and paid separately under respective item . |
| 15 | Supply only water proofing compound complete all as specified and directed by Engineer-in-charge. |
| 16 | Material & labour for preparing new plastered ceiling/soffits of chajjas surfaces and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge |
| 17 | Material & labour for preparing new plastered wall surfaces and applying two coats of distemper with distemper oil emulsion, white or tinted including one coat of 3 mm wall care putty by finishing the surfaces even and smoothcomplete all as specified and directed by Engineer-in-Charge. |
| 18 | Material & labour for preparation of plastered or unplastered new extrernal wall surfaces of walls and applying two coats of exterior emulsion paint over one coat of primer complete all as specified and as directed byEngineer-in-Charge. |
| 19 | Material & labour for preparation of old treated surfaces of wall including brooming down, scrapping down smoke soots etc. and appying one coat of white wash complete all as specified and directed by Engineer-in-charge.. |
| 20 | Material & labour for preparation of old treated surfaces on ceilingincluding brooming down, scrapping down smoke soots etc. and appying one coat of white wash complete all as specified and directed by Engineer-in-charge.. |
| 21 | Material & labour for preparation of old treated surfaces of wallsurfaces and applying one coat of distemper with distemper oil emulsion white or tinted complete all as specified and directed by Engr-in-Charge. |
| 22 | Material & labour for preparation of old treated surfaces on ceilingand applying one coat of distemper with distemper oil emulsion white or tinted complete all as specified and directed by Engr-in-Charge. |
| 23 | Material & labour for preparation of old treat wall surfaces including brooming down and applying one coats of exterior emulsion paint complete all as specified and directed by Engineer-in-Charge |
| 24 | Material & labour for preparation of old wooden painted surfaces of any description exc 10 cm width or girth and appying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge. |
| 25 | Material & labour for preparation of old steel painted surfaces of any description exc 10 cm width or girth and appying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge. |
| 26 | Material & & labour for complete removal of existing treatment on wall surfaces and applying two coats of distemper over a coat of wall care putty by finishing the surfaces even and smooth complete all as specified and directed by Engr-in-Charge. |
| 27 | Supply & fix in repairs vitreous china wash basin, angle back, size 550x400mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed by Engr-in-Charge. |
| 28 | Supply & fix in repairs for pillar taps of 15 mm bore, fancy type with capstan head, chromium plated, screwed down high pressure, with long screwed shanks and fly nuts, screwed for iron pipe & fixed complete all as specified and directed by Engineer-in-Charge. |
| 29 | Supply & fix waste pipe of 32mm dia PVC pipe for WHB with long screwed shanks and fly nut flange end beddedd in red lead cement and other end fixed complete all as specified and as directed byEngineer-in-Charge. |
| 30 | Supply & fix in repairs for bevelled edge mirror of size 600mm x 450mm selected quality glass mounted on6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws complete all as specified and directed by Engineer-in-charge. |
| 31 | Supply & fix in repairs aluminium anodised tubular towel rail 20mm dia D Type 60cm long between flanges complete all as specified and directed by Engineer-in-charge. |
| 32 | Supply & fix in repairs for Vitrious china squattin pan ,Orissa Paattern Size 580x440 mm white with integral foot rests ( Excluding flushing cistern and flush pipe) complete all as specified and directed by Engr-in-Charge. |
| 33 | Supply & fix in repairs vitreous china wash down water closet pan (pedestal pattern) white (excluding, flushing cistern and flush pipe) complete connected to p trap complete all as specified and directed by Engineer-in-Charge. |
| 34 | Supply & fix in repairs jet spray to EWC with PVC nozzle, PVC fish plates and PVC fish plates and PVC flexible pipe etc complete all as specified and as directed byEngineer-in-Charge. |
| 35 | Supply & fix in repairs for grating square 150mmx150mm size of stainless steel complete all as specified and directed by Engineer-in-charge. |
| 36 | Supply & fix in repairs PVC low level valveless, syphonic action type flushing cistern, low level, white, with inlet, ball valve, flaot and handle including brackets of 10 Ltr capacity complete all as specified and directed by Engineer-in-Charge |
| 37 | Taking up on down steel tubing and connection incl cleaning for refining complete all as specified and directed by Engineer-in-Charge of the following bore of pipe |
| 38 | 15mm bore |
| 39 | 20mm bore |
| 40 | Supply & fix CPVC pipes ISI marked, IS-15778 with all fittings for hot and cold water, fixed with solvent cementcomplete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge of following sizes: (SDR-13.5) |
| 41 | 15mm bore |
| 42 | 20mm bore |
| 43 | Supply & fix in repairs for bib taps, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for size15mm bore complete all as specified and directed by Engineer-in-charge.. |
| 44 | Supply & fix in repairs stop valve 15mm dia cast chromium plated screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-charge.. |
| 45 | Supply & fix in repairs for brass CP mixer for mixing hot and cold water screweddown for iron pipe and fixed for size 15 mm bore complete all as specified and directed by Engineer-in-charge.. |
| 46 | Supply & fix in repairs for shower rose for 15 mm dia, 125mm long, cast chromium plated screwed down high pressure with long shank screwed end for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-charge.. |
| 47 | Supply & fix PVC connection 450mm long with check nut for wash hand basin etc complete all as specified and directed by Engineer-in-charge.. |
| 48 | Supply & fix in repairs hand health faucet spray to EWC with PVC nozzle, and PVC flexible pipe etccomplete all as specified and directed by Engineer-in-charge.. |
| 49 | Supply & fix in repairs bathroom cabinet PVC frame box type with mirror in front of size 350x450mm with 6 m thick glass fixed to wall with screws complete all as specified and directed by Engineer-in-charge.. |
| 50 | Supply & fix in repair bib cock with wall flange, cast copper alloy, fancy type chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm dia of pipe complete all as specified and directed by Engineer-in-charge. Jaquar ( Cat No-QQT-7037) or equlvalent(KOHLER/GROHE/CERA/JOHNSON/HINDWARE/JAINKO). |
| 51 | Supply & fix in repairs Angular stop cock with adjustable wall flange, cast coper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions, and fixed for bore 15mm bore of pipe complete all as specified and directed by Engineer-in-charge. Jaquar ( Cat No-QQT-7053) or equlvalent(KOHLER/GROHE/CERA/JOHNSON/HINDWARE/JAINKO). |
| 52 | Supply & fix in repairs chromium plated mixing valve, wall mixer 3 in 1 system with provision for both telephone shower and overhead shower complete with wall flange with 115mm long bend pipe including three joints to steel pipe or unions complete all as specified and directed by Engineer-in-charge. Jaquar ( Cat No-QQT-7281) or equlvalent(KOHLER/GROHE/CERA/JOHNSON/HINDWARE/JAINKO). |
| 53 | Supply & fix in repairs chromium plated mixing valve (central hole basin mixer) with small spout without popup waste system with 450mm long braided hoses including three joints to steel pipe or unions complete all as specified and directed by Engineer-in-charge.Jaquar ( Cat No-QQT-7167) or equlvalent(KOHLER/GROHE/CERA/JOHNSON/HINDWARE/JAINKO). |
| 54 | Supply & fix in repairs chromium plated telephone shower with 1.5m long flexible tube & swill wall hook including fixed to steel pipes or union complete all as specified and directed by Engineer-in-charge. Jaquar ( Cat No-HSH-5537H)or equlvalent(KOHLER/GROHE/CERA/JOHNSON/HINDWARE/JAINKO). |
| 55 | Supply & fix in repairs chromium plated metropole flush valve dual flow concealed type woth control cock operation plate 40 mm size including fixed to steel pipes or union complete all as specified and directed by Engineer-in-charge.Jaquar ( Cat No-FLV-1089Q) or equlvalent(KOHLER/GROHE/CERA/JOHNSON/HINDWARE/JAINKO). |
| 56 | Supply & fix in repairs of vitreous China wash basin including pedastal, white, flat back, size 630mm x 450mm including chromium plated waste coupling, plug and chain, necessary brackets complete all as specified and directed by Engineer-in-charge.Jaquar ( Cat No-1008 & 1108) or equlvalent(KOHLER/GROHE/CERA/JOHNSON/HINDWARE/JAINKO). |
| 57 | Supply & fix in repairs chromium plated toilet paper holder complete all as specified and directed by Engineer-in-charge.Jaquar ( Cat No-AQN-7751) or equlvalent(KOHLER/GROHE/CERA/JOHNSON/HINDWARE/JAINKO). |
| 58 | Supply & fix in repair 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium road and high density plastic ball screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-charge.. |
| 59 | Dismantling of cast iron, PVCor reinforced concrete pipes jointed in cement mortar and taking out of trenches, if required complete all as specified and directed by Engineer-in-Charge of following sizes:- |
| 60 | 100/110mm bore |
| 61 | 75mm bore |
| 62 | Supply & fix PVC ultra drain,SelFit pipes, single socketed, ISI marked, IS-13592 type \"B\" in any length, jointed with solvent cement fixed in walls and floors complete all as specified and directed by Engineer-in-Charge of following sizes:- |
| 63 | 110mm bore |
| 64 | 75mm bore |
| 65 | Supply & fix PVC junction single \"Tee\" equal with door opening, ISI marked, IS-14735, jointed with solvent cement complete all as specified and directed by Engineer-in-Charge of following sizes:- |
| 66 | 110mm bore |
| 67 | 75mm bore |
| 68 | Supply & fix PVC sockets equal, ISI marked, IS-14735, jointed with solvent cement complete all as specified and directed by Engineer-in-Charge of following sizes:- |
| 69 | 110mm bore |
| 70 | 75mm bore |
| 71 | Supply & fix PVC bend equal of any radius with door, ISI marked, IS-14735, jointed with solvent cement for 75mm size pipes complete all as specified and directed by Engineer-in-charge.. |
| 72 | Supply & fix PVC bend equal of any radius without door, ISI marked, IS-14735, jointed with solvent cement for 110mm size pipes complete all as specified and directed by Engineer-in-charge.. |
| 73 | Supply & fix in repair stainless steel sink with drainage board, made out of 1 mm thick sheet for kitchen or laboratory with plug washer waste pipe cast iron cantilever brckets connecting union overall size 915mm x 460 mm with bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed by Engineer-in-charge.. |
| 74 | Supply & fix in repairs stainless steel plate rack made out of 1mm thick stainless steel sheet, overall minimum size 60cm x 90cm and for 6 plates as approved by GE complete all as specified and directed by Engineer-in-charge.. |
| 75 | Disconnecting existing water tanks, setting aside (or lowering if required) for repairs, cleaning etc capacity of tank exc 500 and n.exc 1000 ltr complete all as specified and directed by Engineer-in-charge.. |
| 76 | Supply & fix in repair PVC tank cover for the tank sizes of 500/750/1000 ltrs including all fittings complete all as specified and directed by Engineer-in-Charge. |
| 77 | Supply & fix in repair rotational moulded polythene white water storage tank tripple layared (cylindrical , vertical with closed top , ISI marked , ) hoisted and fixed in position all as specd in SSR Part 1 of capacity 500 ltrs including taking down existing tank also including provision of 20 mm bore ball valves , high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum wt 455 gms) complete all as specified and directed by Engineer-in-charge.. |
| 78 | Supply & fix in repair rotational moulded polythene white water storage tank tripple layared (cylindrical , vertical with closed top , ISI marked , ) hoisted and fixed in position all as specd in SSR Part 1 of capacity 750 ltrs including taking down existing tank also including provision of 20 mm bore ball valves , high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum wt 455 gms) complete all as specified and directed by Engineer-in-charge.. |
| 79 | Cleaning & removing all scale and dirt etc from PVC water tank and from mouths of circulating pipes etc of capacity exc. 250 liters and n.exc. 500 ltrs including disconnecting and refixing all parts required to bedisconnected for cleaning of the tanks complete all as specified and directed by Engineer-in-charge.. |
| 80 | Cleaning & removing all scale and dirt etc from PVC water tank and from mouths of circulating pipes etc of capacity exc. 500 liters and n.exc. 1000 ltrs including disconnecting and refixing all parts required to bedisconnected for cleaning of the tanks complete all as specified and directed by Engineer-in-charge.. |
| 81 | Taking down chowkhat or frames with shutter (without taking off shutters from the frames)n exc 1.5 sqm complete all as specified and directed by Engineer-in-charge.. |
| 82 | Taking down chowkhat or frames with shutter (without taking off shutters from the frames) exc 1.5 sqm but n.exc 4.00 sqm complete all as specified and directed by Engineer-in-charge.. |
| 83 | Taking down shutters of any description exc 1.0 sqm but n.exc 2.00 sqm complete all as specified and directed by Engineer-in-charge. |
| 84 | Taking down and refixing in same opening after any type of alteration of shutters of any description of exc 1.0 Sqm but not exc 2.0 Sqm each complete all as specified and directed by Engineer-in-charge. |
| 85 | Supply & fix pressedsteel frames of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock stricke plate etc complete all as specified and directed by Engineer-in-charge.. |
| 86 | Supply & fix pressedsteel frames of size 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock stricke plate etc complete all as specified and directed by Engineer-in-charge.. |
| 87 | Material & labour for providing cement concrete type B-0, 1:2:4 (using 12.5mm graded stone aggregate) as in roof kerbs, mud stops, filling in frames and the like rounded or or chamfered on edges complete all as specified and directed by Engineer-in-charge.. |
| 88 | Supply & fix 35mm thick 2nd class hard wood factory made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc, with sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/ Gauge etc. Size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24(a) complete all as specified and directed by Engineer-in-charge.. |
| 89 | Supply & fix 35mm thick 2nd class hard wood factory made plain framed, paneled shutters (any number of panels), with lock rail and panel of 9mm BWP commercial ply or 12mm veveered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (part-I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer-in-charge.. |
| 90 | Supply & fix solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification complete all as specified and directed by Engineer-in-charge.. |
| 91 | Supply & fix factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification complete all as specified and directed by Engineer-in-charge.. |
| 92 | Supply & fix butt hinges 100mm size, medium weight, cold rolled mild steel complete all as specified and directed by Engineer-in-charge.. |
| 93 | Material & labour for prelaminated particle board 19mm thick interior grade prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work fixed for cuboards/shelfs etc complete all as specified and directed by Engineer-in-charge.. |
| 94 | Supply & fix continuous (piano) hinges of brass,40mm width, bright finish or electro galvanised complete all as specified and directed by Engineer-in-charge. |
| 95 | Supply & fix 100mm stainless steel handles complete all as specified and directed by Engineer-in-charge.. |
| 96 | Supply & fix magnatic catcher of size 20mm x 50mm suitable for cup board/kitchen cabinet shutter complete all as specified and directed by Engineer-in-charge. |
| 97 | Material & labour for preparing new or previously untreatedsteel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide or zinc chrome primer on steel surfaces complete all as specified and directed by Engineer-in-charge.. |
| 98 | Material & labour for preparing new or previously untreated surfaces wood and wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer on wooden surface complete all as specified and directed by Engineer-in-charge.. |
| 99 | Supply & fix stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed wih SS wire staples complete all as specified and directed by Engineer-in-charge.. |
| 100 | Supply & fix 300mm length of bolt aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cost aluminium alloy complete all as specified and directed by Engineer-in-charge.. |
| 101 | Supply & fix 150mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer-in-charge. |
| 102 | Supply & fix 100mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer-in-charge.. |
| 103 | Supply & fix aluminium, anodised barrel tower bolt of extruded section and fixed 150mm of size complete all as specified and directed by Engineer-in-charge. |
| 104 | Supply & fix aluminium, anodised 100mm size of hasp and staple, safety type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed by Engineer-in-charge.. |
| 105 | Supply & fix floor door stopper of brass body and tongue with hard drawn steel spring, overall length of cover plate 150mm and fixed complete all as specified and directed by Engineer-in-charge.. |
| 106 | Supply & fix mild steel 300mm long ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-charge.. |
| 107 | Material & labour for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed by Engineer-in-Charge. |
| 108 | Supply & fix door strip (snake guard strip) minimum 18 mm wide aluminium body and nylon brushes minimum 22 mm wide alongwith screws for fixing complete all as specified and directed by Engineer-in-Charge. |
| 109 | Taking down aluminium door/window shutter carefully from frames for servicing/including easing adjusting replacement of damaged rubber bearing tighteneing of joints etc complete and make it in functional state complete all as specified and directed by Engineer-in-Charge. |
| 110 | Material & labour for aluminium window with double side hungshutter forglazing and gauging and frame with one or more rebatesanodised aluminium section including section for fixing of aluminium grills with suitable fixtures, jointing cleats for fixing clips, rubber packing, anodised aluminium snap beading screws, anodised aluminiumbeading screws, type B20 100mm long suitable handle and anodised aluminum fittings such asstay, hinges glazing with 5 mm thick tinted sheet glass and gauging with aluminium wire cloth of size 0.45mm dia of wire and 1.40mm aperture as per drg No. CEAA/TD/133 sheet No. 1/2 and 2/2 dated 13.12.02 except fixed glazing (FG) complete all as specified and directed by Engineer-in-charge.(Tint of glass shall be approved by GE) Note :- Aluminium grill fixed under aboveitem shall be measured and paid separately .. |
| 111 | Supply , fabrication & fix anodised (15 micron) aluminium sliding windows/ ventilators aluminium sections as in frames , sliding/ fixed shutters etc. With one or more rebates incl. Jointing cleats & locking arrangements complete all as specified & as per manufacturer\"s instruction complete all as specified and directed by Engineer-in-charge. Note- Quoted rate shalldeemed to be included for supply of aluminium sections, fabricate & fixing in position of window frames & shutters, locking arrangements .. |
| 112 | Supply & fix rubber beading for fixing of glass ofitem No 101 below complete all as specified and directed by Engineer-in-charge.. |
| 113 | Supply & fixsheet glass 5.00 mm thickselected quality and glazing with rubber bearing in squares n exc 0.50 Sqm in each pane. for fixing in aluminium sliding windows complete all as specified and directed by Engineer-in-Charge.Note- Rubber beading shall be measured & paid seperately |
| 114 | Supply & fix in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-charge. |
| 115 | Supply only aluminium anodised grill of approved shape with opening in grill 66mm x 80mm (diagonally) or nearest to + 5mmmade out of standard aluminium moulded section of size 6mm x 7mm complete all as specified and directed by Engineer-in-charge.. |
| 116 | Hacking out old broken glass (any thickness, size, quality or description) from wooden /steel frames or stone , concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed by Engineer-in-charge. |
| 117 | Material & labour for 4.00 mm thick sheet glass ordinary quality andglazing with oil putty in square n exc 0.50 Sqm in each pane complete all as specified and directed by Engineer-in-charge.. |
| 118 | Dismantling of wrought ironor mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-charge.. |
| 119 | Material & labour for framed work as in grills, guard bars, doors or gates of angle, duct frame or other section with gusset plates rails brases etc completed drilled for fixing of steel sheeting or other covering Doorsetc to be prepared for hanging or sliding with and including either hook and hinges or steel hanging and door fitting (exclusive of steel sheeting or other covering) and hanging also fasteningand fixed confirming to Fe 410W or (Gde E-250 Quality) complete all as specified and directed by Engineer-in-charge.. |
| 120 | Dismantling of wall and ceiling boards (fibre, pulb, insulation etc or insulation boards /slabs / blankets any thickness including cover fillets complete all as specified and directed by Engineer-in-charge. |
| 121 | Material & labour for 12 mm thick peformated particle board / tiles for insulation and accoustic purpose 60x60 cm in size fixed with nails to timber frame work or with staples on snap grid complete all as specified and directed by Engineer-in-charge. |
| 122 | Demolitionof cement concrete (unreinforced) of any description and any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-charge. . |
| 123 | Material & labour for special treatment to sunken portion with (a) Clean the sunken portion of toilet/Bath/WC/Kitchen throughlyto remove laitance, dirt, dust, etc.(b) Form angle fillet of size 40 mm x 40 mm along the junction of wall and floor using polymer modified mortar (c)Sanitary pipes entering through walls and floor shall be sealed withand the gaps to be grouted with non-shrink cementitous grout Bathseal Grout\" or eqvt. Nahani traps, etc to be fitted securely and the gaps around it to be grouted in the same manner.(d) Apply one coat of a Bitumen-modified polymer coating on all angle fillets by brush and cover it with 100 mm open woven mesh when it isstill wet. Apply second coat of the same coating on the angle fillets and allow it to dry completely.(e) In the remaining area, in dry sustrate condition brush apply first coat of the same coating and further apply second coat when first coat is dry. Extend the coating upto 150 mm above the FFL. Above FFL,another cementitious waterproof coating \"Dr Fixit Pidifin 2 K\"or eqvt can be further applied right upto 2.1 mm to waterproof the shower area also, it is a bathroom or bath cubicles of a sanitary annex and apply second coat after 6-8 hours and allow to dry completely.. |
| 124 | (f) After 2 to 3 days, sunken portion must be overlaid with a 50 mm avg thick concrete screed M 15 type B0 mixed with intergral WPC (Liquid) laid to slope 1:60 towards outer face of wall. Provide 40 mm under dia UPVC pipe at the lowest point with 300 mm projection beyond the outer face of the wall. Then fill up the sunken portion with lean concrete 1:5:10 type E2.(g) After completing plumbing work in the toilet/WC/Bath/Kitchen floor, tiling work (floor and dado) can be carried out using suitable Tile Adhesives and ready |
| 125 | Removing of old water proofing treatment including screed bed and cleaning the surface of slab with wire brushes removing dust, foreign materials including flushing at junction of wall and removing the rubbish off the premises to a distance exc. 500m complete all as specified and directed by Engineer-in-charge.. |
| 126 | Material & labour for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in roof kerbs/coping/ bed block / depression complete all as specified and directed by Engineer-in-charge. |
| 127 | Material & labour for 15mm thick rendering in cement mortar 1: 4 on faces of brick work or concrete surfaces with WPC, finished even and smooth without using extra cement as in roof complete all as specified and directed by Engineer-in-charge.Note:- WPC shall be measured and paid separately. |
| 128 | Material & labour for water proofing treatment onroofand preparing the surfaces to receive WPT treatment , applying cold bituminous primer@ 0.30 ltr / Sqm conforming to IS 3384 applied on plastered surfaces including side walls , followed by a layers of APP based polymeric membrane reinforced with polyster non woven fabric (weighing 3.5 Kg/Sqm(minimum) and 3 mm thick) with mineral finish laid on primed surface by torch application with side overlap 100 mm and ends over laps 150 mm , joints sealed properly as per manufacturers instructions complete all as specified and directed by Engineer-in-charge.. |
| 129 | Material & labour for 75 mm thick cement concrete type C-2 (1:3:6) using 40 mm graded stone aggregate as in sub base under interlocking tiles complete all as specified and directed by Engineer-in-charge.. |
| 130 | Material & labour for 25 mm thick sand filling under floor including consolidationcomplete all as specified and directed by Engineer-in-charge.. |
| 131 | Material & labour for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade complete all as specified and directed by Engineer-in-charge.. |
| 132 | Dismanteling ofplain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer-in-charge. |
| 133 | Material & labour for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge. |
| 134 | Material & labour for rolled sections as in framing for cladding, glazing, roofing and the like fixed with angle cleats and connecting plates, etc complete all as specified and directed by Engineer-in-charge. |
| 135 | Material & labour for machine cut kota stone slabflooring 20-25mm thick overcement screed base laid and jointed with grey cement slurrymixed with pigment to match theshade of the slab including rubbing and mirror polishing completecomplete all as specified and directed by Engineer-in-Charge. |
| 136 | Material & labour forkota stone slab 20-25mm thick in riser of steps, skiting, dado and pillar laid over cement screed and jointed with grey cement slurrymixed with pigment to match theshade of the slab including rubbing and mirror polishing completecomplete all as specified and directed by Engineer-in-Charge. |
| 137 | Supply & fix in repair plastic water closet seat cover white or black colour closed pattern with flat bottom including taking down old seat cover complete all as specified and directed by Engineer-in-Charge. |
| 138 | Pulling down the existing U/S wires of any type from concealedwiring carefully of aluminium/copper point wiring (light, fan, bell, socket, power point etc.) with or without conduit, along with all connected accessories such as ceiling rose, switches, sockets, switch boards, fan regulator etc complete all as specified and as directed by the Engr-in-Charge |
| 139 | Pulling outsub main wiring only any size of aluminium conductor cable PVC insulated with or without condiut complete all as specified and as directed by the Engr-in-Charge |
| 140 | Material & labour for point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade ISI marked drawn through and including PVC CASING & CAPPING INCLUDING accessories etc including fixed to wall/ceiling including provision of 1.5 sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed as earth wire continuity with PVC surface box complete all as specified and directed by Engineer-in-Charge for:- |
| 141 | One light point controlled by one, one way switch single pole piano type. |
| 142 | One Fan point controlled by one, one way switch single pole piano type. |
| 143 | One 3 pin 5 Amp socket outlet on the same board. |
| 144 | One 3 pin 5 Amps socket out let on independent board. |
| 145 | One bell point controlled by one bell push on independent board. |
| 146 | All as per item No.127 here-in-before but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket out let on independent board complete all as specified and directed by Engineer-in-Charge. |
| 147 | Material & labour for point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade ISI marked drawn through existing conduit including provn of 1.5 sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed as earth wire continuity with new plastic laminated white coloured top sheet cover 3.0 mm thick on existing sunken box complete all as specified and directed by Engineer-in-Charge for:- |
| 148 | One light point controlled by one, one way switch single pole piano type. |
| 149 | One Fan point controlled by one, one way switch single pole piano type. |
| 150 | One 3 pin 5 Amp socket outlet on the same board. |
| 151 | One 3 pin 5 Amps socket out let on independent board. |
| 152 | One bell point controlled by one bell push. |
| 153 | All as per item No.130 here-in-before but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket out let on independent board complete all as specified and directed by Engineer-in-Charge. |
| 154 | Material & labour for sub main wiring with two runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm single core, copper conductor drawn through and including PVC casing capingISI marked with accessories and 4 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engr-in-Charge.(Note: Two runs of conductor with one run of earth wire and PVC casing capping will be measured & paid as one unit) |
| 155 | Material & labour for sub main wiring with two runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 6 Sqmm single core, copper conductor drawn through and including PVC casing capingISI marked with accessories and 6 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engr-in-Charge.(Note: Two runs of conductor with one run of earth wire and PVC casing capping will be measured & paid as one unit) |
| 156 | Material & labour for sub main wiring with four runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm single core, copper conductor in existing conduit and 4 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engr-in-Charge.(Note: Four runs of conductor with two run of earth wire and PVC casing capping will be measured & paid as one unit) |
| 157 | Supply & fix in replacement energy saving, evironment friendly, long life, corrosion resistent, impact proof, Mini LED building securitylight made up of pressure die cast housing with prismatic polycarbonate diffuser and individual LEDs with secondary optics and IP 65 protection with LED 20 W light source including material and labour for suitable bracket made of 20 mm dia light grade GI pipe & MS clamps complete with nuts and bolts and washers complete all as specified and directed by Engineer-in-Charge. |
| 158 | Supply and fixingin repairs wall mounted decorative ultra slimLED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack instant start with uniform light distribution 10 W 2 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting etc complete all as specified and directed by Engr-in-Charge |
| 159 | Supply and fixingin repairs wall mounted decorative ultra slimLED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack instant start with uniform light distribution 18/20 W 4 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting etc complete all as specified and directed by Engr-in-Charge |
| 160 | Supply & fixing in replacement of LED Lamp, 7 W ,Type of cap B22, wideoperating range 140V -280V, Input current 08mA- 30mA, lumen 180-300, UV and IR free light, color temperature 6500K, cool day light, up to 80 % energy saving over GLS complete all as specified and directed by Engineer-in-charge. |
| 161 | Supply & fix in replacement double doorSheet metal enclosures factory made DBsprotection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 triple pole and neutral 4 ways with 200 Amp rated bus bar 415 volts powder coated complete all as specified and directed by Engr-in-Charge. |
| 162 | Supply & fix in replacement double doorSheet metal enclosures factory made DBsprotection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 single pole and neutral 12 ways with 200 Amp rated bus bar 415 volts powder coated complete all as specified and directed by Engr-in-Charge. |
| 163 | Supply & fix in replacement double doorSheet metal enclosures factory made DBsprotection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 single pole and neutral 8 ways with 200 Amp rated bus bar 415 volts powder coated complete all as specified and directed by Engr-in-Charge. |
| 164 | Supply & fix in replacement double doorSheet metal enclosures factory made DBsprotection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 single pole and neutral 4 ways 415 volts powder coated complete all as specified and directed by Engr-in-Charge. |
| 165 | Supply & fix in replacement of isolators/MCBs, etc. In distribution board of the following rating and capacities complete all as specified and directed by Engineer-in-Charge of following:- |
| 166 | MCB TPN 415 volts 63 Amps Capacity, 10 KA |
| 167 | MCB SPN of 240 volts 20/32/40 Amps Capacity, \"C\" series, 10 KA |
| 168 | MCBSP of 240 volts 5-40 Amps Capacity, \"C\" series, 10 KA |
| 169 | Supply & fix in replacementcapacitor of capacity 2.5 mfd (PVC Body) suitable for ceiling/exhaust fans/wall mounted fans of any description,any sweep complete all as specified and directed by Engineer-in-charge. |
| 170 | Taking down and refixing ceiling fans/exhaust fan of any sweep any size from site for repair complete all as specified and directed by Engineer-in-charge. |
| 171 | Material & labour for taking out & removing old burnt-out windings of ceiling fans of any description and rewinding of fan motor with appropriate size super enameled copper wire as approved by Eng-in-charge including insulating material such as illuminous paper,Letherized paper,cotton tape,glass sleeving,insulating varnish ,Bearing ,Bushes,capacitor etc.and transportation to site after testing at workshop,connecting and testing on full load to the entire satisfaction of Eng-in-charge,including painting of fans of any description(ceiling fan/exhaust fan/wall mounte fan/pedestal fan) with applying one coat of synthetic enamel paint(white/Grey) by spray machine including preparation of exisiting decorated surfaces of fans complete all as specified and directed by Engineer-in-charge. |
| 172 | Material & labour for servicing of 1200/1400MM ceilingfan by dismantling carefully and taking out unserviceable parts, dust & grease, cleaning of internal parts with kerosene oil, washing, checking of alignment of shaft, oiling and re-greasing of bearing/bushes including replacing of unserviceable part like bearing ,gun metal bush, capacitor,Rubber reel of suitable capacity and re-assembling the same and complete all as specified and directed by Engineer-in-charge. |
| 173 | All asper item No 146 but rewinding of metal exhaust fans from 250mm to 450 mm sweep size complete all as specified and directed by Engineer-in-charge. |
| 174 | Supply & fix in replacement of PVCbody exhaust fan, AC single phase 230/240V of size 250 mm sweep with louvers including making hole of suitable size/ alteration to the existing hole to fix the Exhaust fan complete all as specified and directed by Engineer-in-charge.(Note: Old unserviceable Exhaust Fan will be deposited in MES store yard). |
| 175 | Supply & fix in replacement of PVCbody exhaust fan, AC single phase 230/240V of size 300 mm sweep with louvers including making hole of suitable size/ alteration to the existing hole to fix the Exhaust fan complete all as specified and directed by Engineer-in-charge.(Note: Old unserviceable Exhaust Fan will be deposited in MES store yard). . |
| 176 | Supply & fix in replacement of metal body exhaust fan, AC single phase 230/240V of size 300 mm sweep with louvers including making hole of suitable size/ alteration to the existing hole to fix the Exhaust fan complete all as specified and directed by Engineer-in-charge.(Note: Old unserviceable Exhaust Fan will be deposited in MES store yard). . |
| 177 | Supply & fix in replacement, switch piano type, 5 Amp. SP, one way complete all as specified and directed by Engineer-in-charge. |
| 178 | Supply & fixin replacement socket outlet 3 pin, 5A, flush complete all as specified and directed by Engineer-in-charge. |
| 179 | Supply & fix in replacement switch socket combination, 2 in 1, 5 Amp, flush type complete all as specified and directed by Engineer-in-charge.. |
| 180 | Supply & fixin replacement switch socket combination 2 in 1, 5/16A 5 in 1 Amp flush type universal complete all as specified and directed by Engr-in-Charge. . |
| 181 | Supply & fix in replacement switch bell push, flush type, 5 Amp complete all as specified and directed by Engr-in-Charge. |
| 182 | Supply & fix in replacement bell, AC, 230 V, SP, ding dong type complete all as specified and directed by Engr-in-Charge. |
| 183 | Supply & fixin replacement stepped type electronicfan regulatorflush type on the existing phenolic laminated etc as reqd single pole 240 volts grade 350 watts heavy duty ISI marked complete all as specified and directed by Engr-in-Charge. |
| 184 | Supply & fixin replacement lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engr-in-Charge. |
| 185 | Supply & fix in replacement of ceiling rose 3 phase, PVC/ Polycarbonate body complete all as specified and directed by Engr-in-Charge. |
| 186 | Supply & fix modular plastic surface box of module 1/2 flush ISI marked complete all as specified and directed by Engineer-in-Charge. |
| 187 | Supply & fix modular plastic surface box of module 3 flush ISI marked complete all as specified and directed by Engineer-in-Charge. |
| 188 | Supply & fix modular plastic surface box of module 4 flush ISI marked complete all as specified and directed by Engineer-in-Charge. |
| 189 | Supply & fix modular white cover plate with frame of module 1 flush ISI markedcomplete all as specified and directed by Engineer-in-Charge. |
| 190 | Supply & fix modular white cover plate with frame of module 2 flush ISI markedcomplete all as specified and directed by Engineer-in-Charge. |
| 191 | Supply & fix modular white cover plate with frame of module 3 flush ISI markedcomplete all as specified and directed by Engineer-in-Charge. |
| 192 | Supply & fix modular white cover plate with frame of module 4 flush ISI markedcomplete all as specified and directed by Engineer-in-Charge. |
| 193 | Supply & fix modular white cover plate with frame of module 6 flush ISI markedcomplete all as specified and directed by Engineer-in-Charge. |
| 194 | Supply & fix modular white cover plate with frame of module 8 flush ISI markedcomplete all as specified and directed by Engineer-in-Charge. |
| 195 | Supply & fix modular blank plate module 1 complete all as specified and directed by Engineer-in-Charge. |
| 196 | Supply & fix in replacement modular switch flush type SP one way, 6 Amp, 1 module ISI Mark complete all as specified and as directed by the Engr-in-Charge |
| 197 | Supply & fix in replacement modular socket outlet 3 pin,6 Amp, flush type 2 module, ISI markedcomplete all as specified and as directed by the Engr-in-Charge |
| 198 | Supply & fix in replacementmodularswicth, 16 Amp flush type 1 module complete all as specified and directed by Engr-in-Charge. |
| 199 | Supply & fix in replacementmodularsocket outlet, 3 pin, 6/16 Amp flush type 2 module complete all as specified and directed by Engr-in-Charge. |
| 200 | Supply & fix in replacementmodularbell push, flush type, 6 Amp,1 module complete all as specified and directed by Engr-in-Charge. |
| 201 | Supply & fixin replacement of ceiling fan regulator 120 Watt 2 module Modular type electronic step type 5 step 360 deg complete all as specified and directed by Engr-in-Charge. |
| 202 | Supply and repair hylum sheet 3mm thick as existed in the switch board making provision for fixing switches and socket complete all as specified and directed by Engr-in-Charge. |
| 203 | Material & labour for disconneting electrically and mechanically the existing geyser of any description,any capacity and make/type and in any position for repair/replacement/painting/cleaning etc including disconneting existing cold and hot water pipe connections, strip opening of geyser for descaling of tank element, thermostate,inlet/outlet water pipe connection etc using suitable chemical/wire brush,replacement of unserviceabe parts, re-assembling the same after,repair/descaling, fixing in position including, connecting inlet/outlet water pipe connection, electrical connections any testing of geyser complete all as specified and directed by Engineer-in-charge. |
| 204 | Supply & fix in replacement metal plug top 20Amps 3 pin complete all as specified and directed by Engineer-in-charge. . |
| 205 | Supply & fix in replacement 2.0 KW electric heating elementat site including rubber ring washers ISI marked complete all as specified and directed by Engineer-in-charge. |
| 206 | Supply & fix in replacement for PVC connection with brass nipple 15 mm x 450 mm long for geyser 25/50 ltrs capacity as per sample complete all as specified and directed by Engineer-in-charge. |
| 207 | Supply & fixing in repair ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 v, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct currect motor(BLDC) complete all as specified and directed by Engineer-in-charge.( Note: Old unserviceable elect meter will be deposited in MES store yard). |
| 208 | Supply &fixingin replacement tamper proof single phase AC KWH meter10-60 Amps with following features including sealing and sealing wire, class – 1 accuracy as per IS 13779, 240V, 50HZ LCD display, forward energy recording irrespective of current direction,LED indication for earth leakage, elegant polycarbonate enclosure high surge with stand up to 8 KV anti temper feature. measures & displays kWh complete all as specified and as directed byEngineer-in-Charge.( Note: Old unserviceable elect meter will be deposited in MES store yard). |
| 209 | Supply & fixing in replacement of water heater storage type 25 Ltr, Ratted wattage 2000W, voltage 230V AC, frequency 50Hz phase single auto cutoff, rust proof external body suitable for highrise building suitable for water pressure head upto 8 bars star rating (BEE) complete all as specified and directed by Engineer-in-Charge( Note: Old unserviceable water heater will be deposited in MES store yard). |
| 210 | Supply & fix in replacementmetal clad enclosure pole and neutral with a two pin and earth plug and socket complete 240 volt with one single pole MCB of 20 Amps complete all as specified and as directed byEngineer-in-Charge |
| 211 | Labour only for attending emergent complaints i.e no light ,earth leakage,short circuit,neutral break,mains/submain/internal circuit of existing system of main building/block,making continious electric supply including carrying out minor repairs etc as required to make the system in order/functional including replacing fuse wire,copper cable,copper thimbles,glands,earthing wire complete all as specified and directed by Engineer-in-Charge.Note:-1.Rate of Fuse wire,copper cable of size 1.5,2.5,4 Sqmm upto 3 RM,copper thimbles,glands,earthing wire are deemed to be considered in this item.2.Minimum One electrician to be present daily during the contract period,if found absent Rs-600 per day will be deducted daily. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail