| 1 | M&L for Laser alignment of alternator with engine of 1250 KVA DG set including replacement of rubber coupling complete all as specified and as directed by Engineer-in-charge.Make of DGSet: Perkins Model 4012-46TAG0A |
| 2 | S&F Drive end bearing of existing make and model as per site requirement for 1250 KVA DG set including main rotor dynamic balancing including taking down old unserviceable item complete all as specified and as directed by Engineer-in-charge.Make of DGSet: Perkins Model 4012-46TAG0A |
| 3 | S&F Non drive end bearing of existing make and model as per site requirementfor 1250 KVA DG set including main rotor dynamic balancing including taking down old unserviceable item complete all as specified and as directed by Engineer-in-charge.Make of DGSet: Perkins Model 4012-46TAG0A |
| 4 | S&F Exhaust Below of 475mm dia size as per existing make and model as per site requirementfor 1250 KVA DG set including necessary nuts, bolts and washers including taking down old unserviceable item complete all as specified and as directed by Engineer-in-charge.Make of DGSet: Perkins Model 4012-46TAG0A |
| 5 | Cleaning the radiator intercooler of1250KVA DG set(Perkins Model 4012-46TAG0A) by checking and removing the deposited dust, oil welt and carbon deposits etc. with wire brushes, cleaning agents etc. complete all as specified and as directed by Engineer-in-charge |
| 6 | Taking down unserviceable self-starter 24 volts for DG set (Perkins Model 4012-46TAG0A) from engine,dismantling and opening of stater and armature,replace the wornout carbon brush,pinion,ignition coil bearing,bushing, including servicing,varnishing of stater after repairingassembling,refixed to same position complete all as specified and directed. |
| 7 | S&F rotating rectifier diode set (forward - 3 Nos & reverse - 3 Nos) along with surge arrestors suitable for 1250 KVA Cummins DG set (Perkins Model 4012-46TAG0A), fixing and connecting in the circuit, starting and testing on load complete all as specified and as directed by Engineer-in-charge. |
| 8 | M&L for carrying out \"B\" check for 1250 KVA DG set [Make: Perkins, Model: 4012-46TAG0A] as per manufacturer\"s recommendation including replacement of necessary spares and filters such as Fuel filter-02 Nos , SLO Bypass filters-02 Nosand Lub oil filters-04 Nos complete including rectification of minor defects, cleaning of air filters/ crankcase breather/Baffeltype breather & coolant tank with air blower, replacement of Engine oil & coolant and tuning of engine all as specified and directed. Location: WB&RJ NSRY[Notes: (i) Supply only Engine oil & Coolant shall be measured and paid separately. (ii) Rate quoted shall include for all filters, topping up distilled water in batteries & minor accessories like nuts, bolts, \"O\" rings etc.] |
| 9 | Supply only Engine oil 15w 40type: API CG4 or for Perkins suitable DG as per requirement and manufacturer recommendation [Make: Servo/ Valvoline/ Castrol/Mobil/Greaves/Perkins] |
| 10 | Supply only premix coolant/ corrosion inhibitor suitable for 1250 KVADG set Make: Perkins, Model: 4012-46TAG0A as per manufacturer\"s recommendation. |
| 11 | S&F battery terminal, brass heavy duty (two nos) complete suitable for fixing on battery poles with nuts and bolts complete including disconnecting and taking down unserviceable battery terminal all as specified and directed. |
| 12 | S&F battery lead copper conductor single core 70sq.mm, 2 metre long (two nos) complete including soldering of copper lugs including disconnecting and taking down unserviceable battery lead complete all as specified and as directed by Engineer-in-charge. |
| 13 | M&L for removing oil/ grease deposits, oil/ paint/ corrosion flakes and cleaning the external surface of 1250 KVA DG set of Make: Perkins, Model: 4012-46TAG0A, along with acoustic enclosure using wire brushes, coarse cloth, cleaning agents etc. and applying two coats of heat retardant paint of approved tint by spray application complete including necessary T&P like spray gun, air compressor etc.complete all as specified and as directed by Engineer-in-charge. |
| 14 | M&L for replacement of turbo blower intake air filter set complete (Primary & Secondary filters) for1250KVADG set of of Make: Perkins, Model: 4012-46TAG0A complete all as per manufacturer\"s recommendation. |
| 15 | Draininng up the fuel tank/Diesel tank in a separate empty barrels, disconnecting the fuel lines from the fuel filters and taking out the fuel tank and clearing internally andremove the accumulated slludge/Sediments and arresting leakages, reconnecting back all the removed fuel lines and mounting the diesel tank its orginal position, supply and replacing the drain plug suitable and including painting of external surfaces by using synthetic enamel paint of two coats over one coat of red oxide primertesting complete for 1250KVAKVA DG Sets capacity Diesel Tanks of DG sets. |
| 16 | Disconnecting/ dismantling 3 phase, 440 volts, 50 cycles exhaust fan electrical motor mounted at top ofDG setfrom its location and shifting to work shop, opening the motor end cover, taking out rotor, taking out burnt stator winding, cleaning the stator and rewinding of motor with appropriate gauge, weight and turns of super enamelled copper winding wire using proper Garware insulating paper, insulating with Class I varnish, and oven drying for requisite insulation values, reassembling the motor completely and bringing back to its original location, greasing,fixing back in position, connecting back electrically and mechanically with proper alignment and testing complete all as specified and as directed for DG set of capacity 1250 KVA of Make: Perkins, Model: 4012-46TAG0A |
| 17 | Supply and connect and test lead acid battery heavy duty 12 volt 180 AH complete with initial charging complete all as specified.(Make : Exide/Amaron) |
| 18 | M&L for repair of DG Set 1250 KVA of Make: Perkins, Model: 4012-46TAG0A by dismantling the sub-assemblies such as fuel pump, fuel injection, governor, turbo-charger, radiator, oil cooler, engine heads, rocker arms, self starter, dynamo-engine wiring, terminal contacts and safety controls etc., including replacement of spare parts as required and re-assembling the sub-assemblies after carrying out necessary repairs including testing and commissioning complete all as directed by Engineer-in-Charge.Note : (a) Supply only spare parts required shall be measured and paid separately under relevant items of schedule \"A\"(b) Repairs and calibration of sub-assemblies shall be measured and paid seperately under relevant items of schedule \"A\". |
| 19 | M&L for repair & calibration of turbo charger as per calibration procedure and norms as per manufacturer\"s standard including replacement of turbo supply & discharge hoses and clamps and de-scaling of turbo charger complete all as specified and directed for the DG Set 1250 KVA of Make: Perkins, Model: 4012-46TAG0ANote : Spares will be measured and paid seperately under relevant schedule. |
| 20 | M&L for repair & calibration of PT fuel pump & injectors as per calibration procedure and norms as per manufacturer\"s including replacement of unserviceable \"O\" rings, plungers and cups etc., for the DG Set 1250 KVA of Make: Perkins, Model: 4012-46TAG0A |
| 21 | M&L for De-scaling of remote coil cooler/radiator by dismantling and cleaning the core pipes with cleaning chemicals (radi wash),components and arrest the leaking core by brazing/dummy with lead including cleaning of upper and lower tanks and replacing gaskets and required nuts, bolts, refixing the same including testing and painting complete all as specified and directed for the DG Set 1250 KVA of Make: Perkins, Model: 4012-46TAG0A |
| 22 | M&L for repair and reconditioning of water pump by complete dismantling and including replacement of unserviceable and wornout spares, fixing back in the engine and testing all as specified and as directed for the DG Set 1250 KVA of Make: Perkins, Model: 4012-46TAG0A |
| 23 | M & L for carrying out Servicing/Overhauling of complete engine including taking down of complete engine of DG set by opening of all heads, piston, rings, fuel injectors, walls and refixing the same after all rectification of engine including replalcement of minor spare parts and Laser alignment of alternator with engine to stop vibration , cleaning of air filter, taking down all oils & coolants and refilling of oils, Inspect for leaks, blockages, and excessive noise,and rectification of minor defects , cleaning of filters / breather , tuning of enginefor DG set of capaciity 1250 KVA. Make: Perkins, Model: 4012-46TAG0AMake of DG Set : Kirloskar or Cummins or Greaves.Notefor item No :- Air filter, Engine oil & Coolent Shall be measured and paid seperately under relevant items. |
| 24 | Supply only the following spare parts as required during repair of DG Set 1250 KVA of Make: Perkins, Model: 4012-46TAG0A |
| 25 | Cylinder liner with O rings |
| 26 | Piston |
| 27 | Keystone barrel ring |
| 28 | Twist taper ring |
| 29 | Coil spring loaded oil-control ring |
| 30 | Piston pin retainer |
| 31 | cylinder head gasket |
| 32 | cylinder head cover gasket |
| 33 | Injector bush |
| 34 | Ring set of piston |
| 35 | Seal ring |
| 36 | Exhaust manifolf gasket |
| 37 | Barrel & plunjer injector |
| 38 | Valve intake |
| 39 | Exhaust valve |
| 40 | Insert Exhaust |
| 41 | Insert intake |
| 42 | Screw adjusting |
| 43 | Nut |
| 44 | Checking of DG Set internal connections like battery connections, solenoid adjusting and PCBcontoller etc and tuning of DG Set of capacity 1250KVA when and as required basis complete all as directed. |
| 45 | S&F PCB Controller as per existing make and model as per site requirementfor 1250 DG set including making connections and tuning of DG Set including taking down old unserviceable item complete all as specified and as directed by Engineer-in-charge.Make of DGSet: Perkins Model 4012-46TAG0A |
| 46 | S&F in repairs fuel hose pipe/lube oil hose pipe of 10mm to 25mm dia (300psi) flexible type, heavy duty as per existing length for 1250KVA DG Set complte all as directed. |
| 47 | S&F in repairs water hose pipe/fuel hose pipe/lube oil hose pipe of 32mm to 50mm diac flexible type, heavy duty as per existing length for 1250KVA DG Set complte all as directed. |
| 48 | M&L Cotton waste for cleaning of DG sets all as specified and as directed by Engineer-in-charge. |
| 49 | Taking down old Silencer Exhaust pipe of any dia and length of existing make and model mouted at any height and ceaningwith cleaning agents, metal filling as per site requirementfor 1250 KVA DG sets installed at WB&RJ, refixing the same Silencer Exhaust pipe with necessary new nuts, bolts and washers including making good the disturbed surfaces complete all as specified and as directed by Engineer-in-charge.Make of DGSet: Cummins/Kirloskar/Perkins. |
| 50 | Taking down old exhaust fan motor and S&Fnew exhaust fan motor of existing make and model mouted at top of DG setas per site requirementfor 1250 KVA DG sets installed at haddo station with necessary new nuts, bolts and washersincluding making good the disturbed surfaces complete all as specified and as directed by Engineer-in-charge.Make of DGSet: Perkins Model 4012-46TAG0A |
| 51 | Taking down old charging alternator and S&Fnew charging alternator of existing make and model of DG setas per site requirementfor 1250 KVA DG sets installed at haddo station with necessary new nuts, bolts and washers and minor partscomplete all as specified and as directed by Engineer-in-charge.Make of DGSet: Perkins Model 4012-46TAG0A |
| 52 | Taking down old coolant level indicator and S&Fnew coolant level indicatorof existing make and model of DG setas per site requirementfor 1250 KVA DG sets installed at haddo station with necessary new nuts, bolts and washers and minor partscomplete all as specified and as directed by Engineer-in-charge.Make of DGSet: Perkins Model 4012-46TAG0A |
| 53 | Taking down old speed sensor and S&Fnewspeed sensorof existing make and model of DG setas per site requirementfor 1250 KVA DG sets installed at haddo station with necessary new nuts, bolts and washers and minor partscomplete all as specified and as directed by Engineer-in-charge.Make of DGSet: Perkins Model 4012-46TAG0A |
| 54 | Taking down old air pressure sensor and S&Fnew air pressure sensorof existing make and model of DG setas per site requirementfor 1250 KVA DG sets installed at haddo station with necessary new nuts, bolts and washers and minor partscomplete all as specified and as directed by Engineer-in-charge.Make of DGSet: Perkins Model 4012-46TAG0A |
| 55 | Taking down old oil pressure sensor and S&Fnew oil pressure sensorof existing make and model of DG setas per site requirementfor 1250 KVA DG sets installed at haddo station with necessary new nuts, bolts and washers and minor partscomplete all as specified and as directed by Engineer-in-charge.Make of DGSet: Perkins Model 4012-46TAG0A |
| 56 | Taking down old solenoid and S&Fnew solenoidof existing make and model of DG setas per site requirementfor 1250 KVA DG sets installed at haddo station with necessary new nuts, bolts and washers and minor partscomplete all as specified and as directed by Engineer-in-charge.Make of DGSet: Perkins Model 4012-46TAG0A |
| 57 | Taking down old relay stop solenoid and S&Fnew relay stop soleniod of existing make and model of DG setas per site requirementfor 1250 KVA DG sets installed at haddo station with necessary new nuts, bolts and washers and minor partscomplete all as specified and as directed by Engineer-in-charge.Make of DGSet: Perkins Model 4012-46TAG0A |
| 58 | Taking down old thermostat and S&Fnew thermostat of existing make and model of DG setas per site requirementfor 1250 KVA DG sets installed at haddo station with necessary new nuts, bolts and washers and minor partscomplete all as specified and as directed by Engineer-in-charge.Make of DGSet: Perkins Model 4012-46TAG0A |
| 59 | Taking down old fuel suction line and S&Fnew fuel suction line of existing make and model of DG setas per site requirementfor 1250 KVA DG sets installed at haddo station with necessary new nuts, bolts and washers and minor partscomplete all as specified and as directed by Engineer-in-charge.Make of DGSet: Perkins Model 4012-46TAG0A |
| 60 | Taking down old fuel return line flexible and S&Fnew fuel return line flexible of existing make and model of DG setas per site requirementfor 1250 KVA DG sets installed at haddo station with necessary new nuts, bolts and washers and minor partscomplete all as specified and as directed by Engineer-in-charge.Make of DGSet: Perkins Model 4012-46TAG0A |
| 61 | Taking down old AC motor for radiator fan and S&Fnew AC motor for radiator fan of existing make and model of DG setas per site requirementfor 1250 KVA DG sets installed at haddo station with necessary new nuts, bolts and washers and minor partscomplete all as specified and as directed by Engineer-in-charge.Make of DGSet: Perkins Model 4012-46TAG0A |
| 62 | Taking down old impeller for radiator and S&Fnew impeller for radiatorof existing make and model of DG setas per site requirementfor 1250 KVA DG sets installed at haddo station with necessary new nuts, bolts and washers and minor partscomplete all as specified and as directed by Engineer-in-charge.Make of DGSet: Perkins Model 4012-46TAG0A |
| 63 | Hiring of a Diesel Generator (DG) set of capacity 500 kVA (silent type, water/air cooled) on contract basis during faulty period of existing DG set, including installation, operation, and maintenance at site. The DG set should be in good working condition, comply with CPCB norms, and be provided with necessary accessories such as AMF panel, cables, earthing, and fuel tank complete all as specified and as directed. |