| 1 | Demolition of brickwork/PCC block or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed. |
| 2 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar, including removal of entire debris as ordered outside MoD land complete all as directed. |
| 3 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exceeding 15 cm thick (above or below ground level) and removal of entire debris as ordered outside MoD land complete all as directed. |
| 4 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to faciliate demolition) including removal of entire debris as ordered outside MoD land complete all as specified and as directed. |
| 5 | Demolition and breaking up drain pipes (Salt glazed stone ware, AC or Reinforced concrete) of 150 mm internal dia set in cement mortar including bedding and haunching complete all as specified and as directed |
| 6 | All same as per serial item No. 5 here-in-above, but 200 mm bore. |
| 7 | All same as per serial item No. 5 here-in-above, but 300 mm bore. |
| 8 | Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and as directed. |
| 9 | Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in hard/ dense soil complete all as specified and as directed. |
| 10 | All as per item No. 9 here-in-above but exc 1.5 m and not exc 3.0 m in depth -do- |
| 11 | Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed. |
| 12 | Removing excavated soil to a distance not exceeding 50 mtsand depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed. |
| 13 | M&L for PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 14 | M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, roof kerbs, mud stops, coved fillets and the like including weathering, slightly rounded, chamfered angle and throating as directed including useand waste of form work (straightor curved) all exposed surface of concrete finished fair complete all as specified & as directed. |
| 15 | M&L for factory madepre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified & as directed. |
| 16 | M&L for precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including placing in position and set in CM (1:4) complete all as specified & as directed.Note :- Reinforcement shall be measured and paid for separately under respective item of this Schedule. |
| 17 | Supply only Integral Water Proofing Compound (ISI Marked). |
| 18 | M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed. |
| 19 | M&L for 75 mm thick plain cement conctere 1:3:6,type C1 (using 20 mm graded crushedstone aggregate) as in plinth protection, hard standing, etc, finished the surface even and smooth without using extra cement, complete all as specified & as directed.Note : Plinth protection shall be of width as directed and shall belaid with an outward slope of 1:40 in alternative bays not exceeding 2.5 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic filling comprising 1 part of heated bitumen Blown grade any penetration and 3 parts of sand (all by weight). Quoted rate of this item shall deemed to include this provision. |
| 20 | M&L for 75mm thick PCC 1:3:6, type C2 (using 40 mm gradedcrushed stone aggregate) as in sub-floors, sub-bases, floors and pavings, etc finished fair and even complete all as specified & as directed. |
| 21 | M&L for factory made M-35 grade, 60 mm thick machine pressed, rubber moulded precast cement concrete interlocking paver blocks of shape and size as directed with grey cement and pigment confirming to IS: 15658-2006 (ISI marked), laid over and including 50 mm thick compacted sand cushion complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of 50 mm thick compacted sand cushioning. (ii) Shape of paver blocks shall be as approved by the GE. |
| 22 | M&L for machine pressed coloured chequered cement concrete tiles of size 295x295x25 mm thick with grey cement and pigments, set and jointed in neat cement slurry in floors and pointed with coloured cement to match the shade of tiles and laying over & including 15 mm thick screed bed in CM 1:6 complete all as specified.Notes: (i) Quoted rate shall deemed to be inclusive of cement screed. (ii) Colour of tiles shall be got approved from GE before incorporation in the work. |
| 23 | M&L for Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surface of walls mixed with WPC mixed @ minimum 2% by weight of cement or as per manufacturer\"s instructions and finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid for separately as \"Supply only\". |
| 24 | S&F in repairs 100 mm bore Cast Iron, sand cast, soil, waste & vent pipe (ISI marked), in any length with or without ears, fixed with cement joints, laid in trenches or floors, complete all as specified and as directed. |
| 25 | S&F in repairs 100 mm bore Cast Iron, sand cast, soil, waste and vent pipes (ISI marked) in any length with or without ears, fixed with cement joints, fixed to walls, complete all as specified and as directed. |
| 26 | S&F in repairs 75 mm bore Cast Iron, sand cast, soil, waste & vent pipe (ISI marked), in any length with or without ears, fixed with cement joints, laid in trenches or floors, complete all as specified and as directed. |
| 27 | S&F in repairs 75 mm bore Cast Iron, sand cast, soil, waste and vent pipes (ISI marked) in any length with or without ears, fixed with cement joints, fixed to walls, complete all as specified and as directed. |
| 28 | S&F in repair 100mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval acess door complete all as specified and as directed. |
| 29 | S&F in repair 75mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval acess door complete all as specified and as directed. |
| 30 | S&F in repair 100mm bore cast iron branch piece, \"Y\", \"T\", single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval acess door complete all as specified and as directed. |
| 31 | S&F in repair 75mm bore cast iron branch piece, \"Y\", \"T\", single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval acess door complete all as specified and as directed. |
| 32 | S&F in repair 100mm bore Cast Iron vent cowl complete all as specified & as directed. |
| 33 | S&F in repair 75mm bore Cast Iron vent cowl complete all as specified & as directed. |
| 34 | S&F in repairs 75mm bore PVC (SWR) pipes single socketed in any length with rubber rings joints/ solvent cement joints, laid in trenches or in floors, complete all as specifed & as directed. |
| 35 | S&F in repairs 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls, complete all as specified & as directed. |
| 36 | S&F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber rings joints/ solvent cement joints, laid in trenches or in floors, complete all as specifed & as directed. |
| 37 | S&F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls, complete all as specified & as directed. |
| 38 | S&Fin repair 75mmbore PVC (SWR) bends any radius with access door including jointing the same with solvent cement complete all as specified & as directed. |
| 39 | S&F in repair 110mm bore PVC (SWR) bends any radius with access door including jointing the same with solvent cement complete all as specified & as directed. |
| 40 | S&F in repair 75mm bore PVC (SWR)junction single (single T) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed. |
| 41 | S&F in repair 110mm bore PVC (SWR) junction single (single T) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed. |
| 42 | S&F in repair 75mm bore PVC (SWR) branch piece (Single Y) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed. |
| 43 | S&F in repair 110mm bore PVC (SWR) branch piece (Single Y) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed. |
| 44 | S&F in repair PVC (SWR) Vent cowl 75mm bore size fixed complete all as directed. |
| 45 | S&F in repair PVC (SWR) Vent cowl 110mm bore size fixed complete all as directed. |
| 46 | S&F in repair PVC (SWR) gully trap 125/110 mm including jonting with solvent cement complete all as specified & as directed. |
| 47 | M&L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate in bedding to drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore drain pipe complete all as specified and as directed.Note : Drain pipe shall be measured and paid for separately. |
| 48 | All as per serial item No. 47 here-in-above, but for 200mm bore pipe -do- |
| 49 | All as per serial item No. 47 here-in-above, but for 300 mm bore pipe -do- |
| 50 | Material & Labour for providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths full round PE DWC (Double Wall Corrugated) Pipe of SN8 grade of 150mm ID as per IS-16098 (Part-2) amended upto date in trenches, fixed and joined with integral socket or coupler and EPDM sealing ring (depending on pipe ends) as per manufacturer’s instructions including testing complete as per Technical Specifications, complete all as specified and as directed.Make: Finolex / Supreme / SFMC / Sintex / Reliance Industries / Astral / Lauritz Knudsen Electrical & Automation (Formerly L&T). |
| 51 | All as per serial item No. 50 here-in-above, but 200mm ID pipe -do- |
| 52 | M&L for Reinforced concrete pipe 150 mm bore, Class NP2 with collars, laid to slope in trenches & jointed in cement mortar (1:1) and tested on completion, complete all as specified and as directed. |
| 53 | M&L for Reinforced concrete pipe 200 mm bore, Class NP2 with collars, laid to slope in trenches & jointed in cement mortar (1:1) and tested on completion, complete all as specified and as directed. |
| 54 | M&L for Reinforced concrete pipe 300 mm bore, Class NP2 with collars, laid to slope in trenches & jointed in cement mortar (1:1) and tested on completion, complete all as specified and as directed. |
| 55 | M&L for cutting into existing manholes/Septic tank for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), reforming benching as required and finishing surface even & smooth for 150mm bore pipe complete all as specified and as directed. |
| 56 | All as per serial item No.55 here-in-above, but for 200 mm bore pipe -do- |
| 57 | All as per serial item No. 55 here-in-above, but for 300 mm bore pipe -do- |
| 58 | Supply and laying of instant ready mix premixed bituminous material for repairing depression on pot holes, material consisting of modified all-weather bitumen paste in liquid asphalt with chemicals, anti-stripping agents, graded aggregates & additives / granular material 5-20mm crushed stone aggregate with 5.5% of bitumen, in 25 Kg bag, laid as per manufacturer’s instructions including preparation of surfaces, complete all as specified & as directed. Make: ‘ShaliPatch’ of STP Ltd or equivalent as approved by GE.Note : The unit of measurement and payment purpose is ‘Per Bag’ of 25 Kg ready mix material. |
| 59 | Cutting and cleaning of vegetation, tree, grass and fencing above ground level for sewage line inspection & line cleaning including removal of entire debris/ vegetation outside MoD land complete all as directed. |
| 60 | Cutting & dismantling of existing road with soling, WBM & premix carpet of any description for removing / laying UG Cables/ pipe line/ sewage lines/ drain etc, and removal of entire debris as ordered outside MoD land complete all as specified & as directed. |
| 61 | M&L for Soling (or sub base) 150mm thick (spread thickness) in one layer with broken boulders or quarried stone (Granite, Trap, Basalt), interstices filled of grading 1 (90 to 45 mm size), surface formed, rolled and consolidated with Hand roller complete all as specified and as directed. |