Name of Work: “Replacement of Existing UPS System with Modular UPS System (with Lithium-ion Battery) for Server Room at IIM Indore\"
Sl. No.
Item Description
1
Supply, Installation, Testing and Commissioning ofModular UPS System Capacity: 3 × 3, 120 kVA, 3 Phase, 415 V, Transformer-free intelligent modular UPS with switches (bottom cable entry), including the following:Function Module: APM 0120 kMH16FY02Z18, 30 kVA Power Modules (with packaging material) — Qty: 3 Nos. Battery Circuit Breaker Enclosure (2 Wire) 630 Amp MCCB, 3 Pole, 600 V DC — Qty: 1 No.Function Module IRMS01T – Temperature Lamp Board (IRM-S01T), RDU-A-S01T — Qty: 1 No.IntelliSlot Unity Dual Protocol Communication Card for remote monitoring — Qty: 1 No.All necessary accessories, interconnections, cable terminations, and commissioning works complete in all respect.As per the direction of the Engineer-in-Charge.(1 set)
2
Supply, Installation, Testing, and Commissioning of Workstation (Core i5 or higher configuration) for centralized monitoring and control of Lithium-Ion Battery Systems (less than 10 racks).A common workstation shall be provided for all five (05) UPS systems for data acquisition, status display, and performance monitoring.The scope also includes providing and commissioning of Lithium-Ion Battery Backup System suitable for 120 kVA / 90 kW (0.8 PF) UPS system , configured as 11S4P for 4-hour backup duration, complete with battery racks (8S1P), connectors, interconnecting cables, safety protection, and accessories as required for proper operation.All work to be completed in accordance with manufacturer’s recommendation and Engineer-in-charge instructions, including complete testing, commissioning, and handover..As per the direction of the Engineer-in-Charge.(1 set)
3
Supply and laying of Nyvin Cable (Minimum 10 Mtr) suitable for DC interconnection between UPS system and Lithium-Ion Battery Bank, including all necessaryterminations, lugs, ferrules, cable dressing, and testing for continuity and insulation resistance, complete as required.Specification:Cable Type: Nyvin (Tinned Copper, Flexible)Voltage Grade: 1100VLength: Minimum 10 Meter as on required as per site conditions Application: UPS to Battery Interconnection Laying: In existing cable tray / conduit with proper support and dressing.As per the direction of the Engineer-in-Charge. (1 Nos)
4
Installation, Testing & Commissioning Charges for complete 120 kVA UPS system & Lithium-Ion as per Battery as per the direction of the Engineer-in-Charge.
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.