| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. a) Group -C |
| 2 | Wiring for twin control light point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface /recessed medium class PVC conduit, 2 way piano type switch,phenolic laminated sheet, suitable size MS box and earthing thepoint with 1.5 sq.mm. FRLS PVC insulated copper conductorsingle core cable etc. as required. |
| 3 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 4 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVCinsulated copper conductor single core cable in surface/recessed medium class PVC conduit along with 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 5 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required .a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 6 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. |
| 7 | Supplying and fixing metal box of 180mm X 100mm X 60mmdeep (nominal size) on surface or in recess with suitable size ofphenolic laminated sheet cover in front including providing andfixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano typeswitch, connections, painting etc. as required. |
| 8 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 9 | Supplying of BLDCCeiling Fan 1200mm Sweep (Colour: White, Brown) similar to Crompton Model : Energion Riviera - ISI w/o remote(ISI Marked and BEE 5 Star Rated) power consumption with switch control with 5 years warranty including wiring the down rods of standard length (upto 60 cm) or its equivalent, etc., as required |
| 10 | Supplying and Fixing of Stepped Type Electronic FanRegulator equivalent to Pressfit Glory 5 Step Regulator (Board) Coad-546070 or its equivalent, etc., as required. |
| 11 | Supplying and Fixing of 450 mm Wall Fan Similar to Make Crompton, Model No. WM SSTORM 2 (Metal Blade)or its equivalent, etc., as required. |
| 12 | Supply of 450 mm exhaust Fan Heavy Duty single phase IP55 Similar to Crompton EXHD450-4-1) 450MM 1400 RPM S.Ph)or its equivalent, etc., as required. |
| 13 | Installation, testingand commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required. |
| 14 | Installation, testing and commissioning of ceiling fan, includingwiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cableetc. as required. |
| 15 | Installation of exhaust fan in the existing opening, includingmaking good the damage, connection, testing, commissioningetc. as required. a)Upto 450 mm sweep |
| 16 | Supplying of 28W LED Batten (T5) Light, CDL Similar to Crompton - Ecoglo LDLSRNX28-CDL/NW/WW, 28W or its equivalent, etc., as required. |
| 17 | Supplying of 10W Bulk Head Similar to Philips Vista Glow or its equivalent etc., as required. |
| 18 | Supplying of 100W Flood Light i/c Bracket for Hanging the light in ceiling Similar to Luker Alcor Flood Light or its equivalent etc., as required. |
| 19 | Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But withoutMCB/RCCB/Isolator) a)4 Way (4 + 12), Double Door |
| 20 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) Single Pole |
| 21 | Supplying and fixing following rating, four pole, 415 V, isolatorin the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 63 A |
| 22 | Earthing with copper earth plate 600 mm X 600 mm X 3 mmthick including accessories, and providing masonry enclosurewith cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 23 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I.pipe from earth electrode including connection with brass nut,bolt, spring, washer excavation and re-filling etc. as required. |
| 24 | EEI WORKSSupplying of followingsize XLPE insulated heavy duty armoured aluminium conductor UG cable of 1.1 KV grade conforming to IS 7098 (Part-I) and IS No:1554 (Part-I) 1988 as applicable Make: CCI/Glooster/ Havells/ Polycab/ Finolex etc as reqd.a) 50sq.mm x 3.5 Core |
| 25 | Supplying of followingsize XLPE insulated heavy duty armoured aluminium conductor UG cable of 1.1 KV grade conforming to IS 7098 (Part-I) and IS No:1554 (Part-I) 1988 as applicable Make: CCI/Glooster/ Havells/ Polycab/ Finolex etc as reqd.a) 35sq.mm x 3.5 Core |
| 26 | Supplying and layingof one number double walled corrugated high density Polythylene pipe having corrugation on the outer wall and plain surface inner wall confirming to IS 14930 Part -I & II complete with necessary HDPE fitting for protection of 1.1 KV grade following size on wall surface as required.a) 77 mm outer dia and 63 mm Inner dia (Clamping with MS Flat Clamp and Screw) |
| 27 | Supplying and layingof one number double walled corrugated high density Polythylene pipe having corrugation on the outer wall and plain surface inner wall confirming to IS 14930 Part -I & II complete with necessary HDPE fitting for protection of 1.1 KV gradedirectly in ground at the depth of 50 cm i/c excavationand refilling in thetrench etc as reqd.a) 50mm outer dia and 38 mm Inner dia |
| 28 | Providing, laying and fixing following dia G.I. pipe (mediumclass) in ground complete with G.I. fittings including trenching(75 cm deep)and re-filling etc as required a)80 mm dia |
| 29 | Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required a) Upto 35 sq. mm |
| 30 | Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required b) Above 35 sq. mm and upto 95 sq. mm |
| 31 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required. |
| 32 | Providing and laying earth connection from earth electrodewith 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earthelectrode including connection with copper thimble excavation and re-filling as required |
| 33 | Supplying, Installation, Testing and Commissioning of out door type water resistant floor mounted Cubical Panel Board of size 1.00 x 0.70 x 0.70 mtr non- extendable type LT 3 Phase 440 Volt 200 A with both side open including front double hang shutter with locking arrangements made with 2 mm thick CRCA Sheet, MS Angle, MS Flat etc.,different compartment to accommodate various sizes of switch gear, MCCB, Changeover, Cutout, energy meter etc, including Supplying and Fixing of following item including interconnection with suitable rating Cu. Strip/ Cable. The Panel shouldhave inner earthing 1 coat of primer and 2 coat of finishing water proof paint, fixing of danger plate and PCC work etc., as required.(i) MCCB 100A / 4 Pole 38 KA Breaking Capacity - 01 No.(ii) MCCB 63A/ 4 Pole 26 KA Breaking Capacity - 01 No.(iii) Cut outs 100A - 03 Nos.(iv) On-Load Changeover Switch 4 Pole Open Execution Type, 100A - 01 No.(v) Insulation with PCC Work. |
| 34 | Supplying and Fixing of CO2 Type Fire Extinguisher 2 Kg Capacity Consisting of Welded cylinder squeeze lever discharge valvefitted with pressure indicating gauge, internal discharge tube, discharge nozzle suspension bracket conforming to ISI: 15683 - 2006 duly charged with ISI marked with bracket and fixing suitable screw etc., as required. |
| 35 | Supplying and Fixing of ABC Store Pressured Type Fire extinguisher 2 Kg capacity consisting of welded Cylinder squeeze lever discharge valve fitted with pressure indicating gauge, internal discharge tube, discharge nozzle suspension bracket conforming to ISI: 15683 - 2006 duly charged with ISI marked with bracket and fixing suitable screw etc., as required. |
| 36 | Supplying and Fixing of Fire Bucket made out of 24 SWG MS Sheet Similar to IS: 2546 on the existing wall by wall mounting bracket. |