| 1 | Design, Supplying, Installation, Testing & Commissioning of 13 passenger (884kg) capacity passenger Machine room less (MRL) lift with regenerative drive as per CPWD General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having provision for barrier free access as per Harmonised Guidelines & Standards for Universal Accessibility in India - 2021 of MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and as under including all other equipment and accessories complete as required:-1) Capacity of the lift:- 13 Passenger2) Type:- Machine Room Less3) Load:- 884 Kg4) Speed:- 1.5 M/s5) Travel:- Upto 35 Meters (Approx)6) No. of Floors:- G+97) Stops & Openings:- 10 stops (G,1,2,3,4,5,6,7,8,9)8) Controller: A.C. variable voltage & variable frequency9) The Lift shall be provided with automatic rescue device with dry maintenance free batteries as required.10) Operation: Microprocessor based single automatic push button/simplex selective collective/duplex collective selective with/without attendant to be provided.11) The lift shall be provided with full Door Infrared door curtain12) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system13) Types of Doors:- Centre Opening sliding doors made of stainless steel 304 scratch proof of 1.5mm thickness honeycomb/moon rock/Hariline finish. Lift car shall have minimum entrance of 900mm. Lift car door shall have a fire resistance rating of 2 hr. to be provided14) Landing doors & Door frame- Power operated-Centre opening sliding doors & Door frame shall be stainless steel 304 scratch proof of 1.5mm thickness, Honeycomb/Moon Rock/Hairline finish. Landing doors shall have a fire resistance of 2 hr. to be provided15) Lift car ceiling:- It shall have LED-Lights and decorative ceiling fans and shall be of stainless steel 304 scartch proof of 1.5mm thickness. Flooring:- 20mm granite flooring. Handrails not less that 600mm long at 900mm above floor level to be 3 sides in the car and mirror on the backside.16) Lift shall have all the features as per accessible India Norms updated till date and shall be Installed in compliance with the norms.17) Lift shall have Braille system push butthons of minimun dimensions of 20mm with height of the letter size 15mm including all facilities for physically challenged persons18) Lift shall have voice announcement system in the car to announce the position of the elevator in the Hoist way as car passes or Stops at floor served by the elevator, panel and signals, lift car, car safety devices as per Is: 14665 and as amended upto date. Note:- 1) Voice announcement shall be operative during operation of ARD also. 2) During ARD operation lights/emergency light and fan shall be in working condition. If required separte inverter should be provided for which nothing extra shall be paid. In case of failure of failure of ARD or other electronic devices, a provision of manual rescue be provided without dependent on the batteries.19) Closed loop Control System, protection against power fluctuation, self diagnostic control, Overload detection and protection along with audio and Visual Indicator, Overspeed Governer, Dot Matrix LED D & P Indicators In Car & Landings, BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup , Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder, Lift shall have fireman switch at ground Floor Lift shall be provided with automatic shut off fan. 20) GI Boxes for control buttons shall be provided at Height of 800 to 1000mm from ground level in all landings21) Lift shall have call buttons at Height of 800 to 1000mm from ground level in all landing. 22) 2 No\"s car Operating panels shall be provided-one on Each side of the car door inside the lift at a height of between 900mm to 1100mm from floor level.23) An appropriate technological support be provided (Through emergency messaging) etc., to respond to the emergency requirements of person with hearing impairment or deafness. 24) Lift shall have 2 way 3 station inter communication system/Telephone sytem.25) All safety precautions, lift numbering, and emergency contact information shall be provided on a permanent, non-removable basis inside the lift car and outside, as directed by the Engineer-in-Charge. The materials used shall be durable, tamper-proof, and suitable for long-term usage.26) Minor building work related to lift installation shall be provided complete as per specifications.27)The OEM agency shall provide one year free comprehensive maintenance with the 12 monthly servicing and attend all types breakdowns without any additional cost. 28) The bidder is required to first dismantle the existing lift and thereafter install new supplied lift and other works as per the instructions of Engineer-In-chagre.29)The dismantling of the existing lift shall be carried out by the bidder, and the dismantled material will be taken by the bidder under the buy-back mode. No additional charges shall be paid for the dismantling of the existing lifts. |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group-C |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the 2 X 4 sq. mm + 1 X 4 sq. mm earth wire sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 4 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 5 | Supplying and fixing 12 way , Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 6 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 7 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of Double pole in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 8 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of Triple pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 9 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) body material 18- 22 watt and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OE warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) |
| 10 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. (Charcoal=96 kg, Salt=5 kg) |
| 11 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 12 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 13 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 14 | Dismantling granite work in walls, floors and roofs laid in cement mortar including stacking material within 50 metres lead., for thickness of tiles 10 mm to 25 mm. |
| 15 | Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : |
| 16 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead.Of area 3 sq. metres and below. |
| 17 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 18 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 19 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge. |
| 20 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 21 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) derived from natural sources. |
| 22 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 23 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite stone slab colour black, Cherry/Ruby red Area of slab upto 0.50 sqm |
| 24 | Supplying and applying of Nitocote wall guard (fosrac brand) for External walls where the dampness is observed and instructed by Dept. including all materials, labour incidental and operational charges complete etc., for 2 coats on old external walls after applying one priming coat of Nitoprime AW (fosrac brand). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes and filling of cracks with Nitoseal PU50 as per the direction of Engineer-in-Charge. Procedure to be followed: 1) Surface Preparation: Surface shall be prepared by mechanical grinding to remove all loose mortar, laitance, oil, grease, decayed matter and algae growth.2) Filling of Cracks: Identify cracks on the walls and then chasing them open in the form of “V” groove (Cutting of the crack shall be done of size 10 mm x 10 mm) and Fill the “V “groove with NITOSEAL PU50 properly.3) Priming coat: The prepared surface shall be applied one coat of acrylic primer, Nitoprime AW prior to the application of Nitocote wallgaurd, prime coat should be air cured for 6 hours. 4) Wall gaurd application: Nitocote wall gaurd (Fosroc brand) at a thickness of 110 microns DFT each coat, in two coats. Each coat must be air cured for 6 hours. (GST applied as per DSR-21) Note: The above work has to be done with the help of trained and skilled labour. |
| 25 | Supplying and applying of roofguard (fosrac brand), a single component acrylic polymer modified, elestomeric fiber reinforced waterproofing coating applied in three coats of thickness 1 mm DFT in three coats after applying one priming coat of Nitoproof WB primer (fosrac brand) on the roof, including all materials, labour incidental and operational charges complete etc., . The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes and filling of cracks with Nitoseal PU50 as per the direction of Engineer-in-Charge.,Procedure to be followed: 1) Surface Preparation: Surface shall be prepared by mechanical grinding to remove all loose mortar, laitance, oil, grease, decayed matter and algae growth.2) Filling of Cracks: Identify cracks on the walls and then chasing them open in the form of “V” groove (Cutting of the crack shall be done of size 10 mm x 10 mm) and Fill the “V “groove with NITOSEAL PU50 properly.3) Priming coat: The prepared surface shall be applied one coat of acrylic primer, Nitoproof WB primer prior to the application of Roofgaurd, prime coat should be air cured for 6 hours. 4) Roof gaurd application: Roofgaurd (Fosroc brand) at a thickness of 1 mm DFT in three coats. Each coat must be air cured for 6 hours. (GST applied as per DSR-21) Note: The above work has to be done with the help of trained and skilled labour. |
| 26 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 27 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work |
| 28 | Wall painting with acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats |
| 29 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. |
| 30 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron). |
| 31 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) |