| 1 | Deploying the following manpower for routine maintenance & repairing of raw/effluent water pump sets, submersible p/sets, Water Cooler with RO Water Purifier & other Electrical installation, attending day to day complaints on all days i/c preventive maintenance as per schedule & terms & conditions and inventory attached.(a) Wireman cum operator Grade II - 2 Nos. daily in General shift (9:00 AM to 5:00 PM) or as and when required.(b) Khallasi - 1 No. daily in General shift (9:00 AM to 5:00 PM) or as and when required. |
| 2 | Supplying and replacement of following sizes of PVC insulated and PVC sheathed/XLPE aluminium conductor armoured power cable of 1.1 KV grade conforming to IS:7098 (Part-I) connection & testing i/c rebate for dismantle material etc. as required. |
| 3 | 4Cx25 Sq.mm |
| 4 | 2Cx16 Sq. mm |
| 5 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe/DWC Pipe as required. |
| 6 | Upto 35 sq. mm |
| 7 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonary open ductas required. |
| 8 | Upto 35 sq. mm |
| 9 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 10 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (upto 750 mm.) or as directed by Engineer-in-charge including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required.40 mm dia (OD-40 mm & ID-32 mm nominal) |
| 11 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.a)3 x 2.5 sq. mm |
| 12 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 13 | 4Cx25 sq.mm. |
| 14 | 2Cx16 sq.mm. |
| 15 | Lifting out ofsubmersible pump set of capacity 2 H.P to 7.5 H.P. from the existing borewell along with existing pipe GI pipe and dismantling of cable upto reqd. depth etc. complete as reqd. |
| 16 | Lowering,testing & commissioning of submersible pump set of capacity 2 H.P. to 7.5 H.P. in the borewellalongwith GI pipe & submersible cable , connectionetc. complete as reqd. |
| 17 | Repairing & rewinding of following rating(Motor & Pump) i/c remetalling of impeller,bush,neck ring,SS shaft including cartagedismantling & reassembling ,painting after repair,nuts,bolts,strainers,testing etc. complete as reqd i/c rebate for dismantle material. |
| 18 | 15 HP sewage submersible pump set(3 Phase) |
| 19 | 7.5 HPsewage submersible pump set (3 Phase) |
| 20 | 1.5 HP 12 stage openwell(single phase) |
| 21 | 3 HP 23 to 30 stage submersible pump set (3 phase) |
| 22 | 4 HP 30 stage submersible pump set (3 phase) |
| 23 | 5 HP 30 stage submersible pump set (3 phase) |
| 24 | 6 HP 32 stage submersible pump set (3 phase) |
| 25 | 2 HP mono block pump set (single phase) |
| 26 | Supplying/Replacement of following size of double flanged GI pipe marked \"B\" class duly threaded & welded with necessary pipe fitting bends, elbow etc completed as reqd. i/c rebate for dismantle material. |
| 27 | 50 mm dia |
| 28 | 40 mm dia |
| 29 | Supply & replacement of DOL starter suitable for pumps 5 HP to 7.5 HP with suitable relay range, single phase preventor, contactor, MCB and all required accessories to be mounted on existing outdoor feeder pillar making connections, testing,commissioning, replacing old starter i/c rebate for dismantle material etc. complete as required. |
| 30 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door |
| 31 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm. |
| 32 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 33 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 34 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A |
| 35 | Wiring for light/ power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 36 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm) |
| 37 | 6 Module (200mmX75mm) |
| 38 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 39 | 5/6 A switch |
| 40 | 15/16 A switch |
| 41 | 3 pin 5/6 A socket outlet |
| 42 | 6 pin 15/16 A socket outlet |
| 43 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 44 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 45 | Single pole |
| 46 | Double pole |
| 47 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light (System lumen efficacy ≥105 <120 lm/Watt) of following body materialand construction as per IS : 10322 withdriver (Replaceable)as per the requirement with Driver efficiency >85% ,Operating voltage AC140-270 Volt,freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20,CRI>80, Flicker free, (flickershould be below 5 %), life time (LED,Driver & electrical circuitary),ofminimum 50000BurningHourswith,70%ofinitial Lumenmaintained tilllife ends, CCT3000°K/ 4000°K / 5700°K/6500°K(AsperANSIBin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BISstandard andtrade markcertificate(T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. completeinallrespecti/c external connectionswith1.5sqmmFRLS/HFFR,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy≥105 <120lm/Watt output . LM79 & LM80 Test report andalltestingrequiredforLED fixtures as per BISshall be submitted.Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) 18- 22 Watt |
| 48 | Supply, replacement, testing & commissioning of LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt), powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as perrequirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Rate including rebate for dismantled material a) 70 watt |
| 49 | Providing and fixing following capacity TP & N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses i/c drilling holes in cubicle panel, making connection etc as reqd. |
| 50 | 32 A TP &N |
| 51 | 63 A TP &N |
| 52 | 200 A TP &N |
| 53 | Supplying and replacement of exide IMT 1500 12 W 150 Ah tubular Battery i/c buy back value for old battery |
| 54 | Comprehensive maintenance contract of 1400 VA inverter without battery |
| 55 | Rewinding copper winding & repairing of 1200/1400 rpm ceiling fan of different maketesting etc. as reqd. |
| 56 | Routine preventive, breakdown and comprehensive maintenance of Air conditioners (Split Type) upto 1.5 TON capacity & Water Coolers i/c attending & removal complaints, cleaning of Filters & grills of AC, cleaning of Water Tank. |
| 57 | Comprehensive maintenance contract of RO/ Water purifier cooling with capacity 50 Ltr. Installed in DDA office |
| 58 | Comprehensive maintenance contract of Water cooler |
| 59 | Comprehensive maintenance contract of Air conditioners split type 1.5 Ton for 1 season |