| 1 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc.,complete all as specified and as directed by the Engineer-in-Charge. |
| 2 | Material and labour for point wiring with 1.50 Sqmm single core PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling surfaces and including provision of 1.50 Sqmm single core PVC insulated, unsheathed cable FRLS-H, 1100 volt grade, ISI marked with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly(boxesshall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally) including provision of new covered plate over sunken box for housing themodular switches, modular socket outlets,modularfan regulators etc.for one light/fan/exhaust fan/bell point controlledby one way switch, complete all as specified and as directedby Engineer-in-Charge. Note :-a) All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately . |
| 3 | Supply and fixing of modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts, complete all as specified and as directedby Engineer-in-Charge. |
| 4 | Supply and fixing ceiling rose surface type 2/3 terminalpolycarbonate, isolated body, complete all as specified and as directed by the Engineer-in-Charge. |
| 5 | Supply and fixing in repairLED batten fitting 20 watt, 4 feet, polycarbonate housing with electronic drivercool/warm type, connecting with copper conductor flexible cablefrom ceiling rose to connector of the light, complete all as specified and as directed by the Engineer-in-Charge. Cat part No. LBLN-20-C-SQ of make Orient or equivalent in make given in Appx \"B\". |
| 6 | Supply and fixing in repair, LED surface mounted bulk head luminaries 8-10 watt with min 800 lumen, IP 65,PVC housing, surge protection including driver and LED lamp, etc. complete with all accessories, connecting with copper conductor flexible cable from ceiling rose to connector of the light, complete all as specified and as directed by the Engineer-in-Charge. Cat part No. LIBH-10-C-P of make Orient or equivalent in make given in Appx \"B\". |
| 7 | Supply and fixing in repair,LED Bldg Security Light Fittings of capacity 20-25 watt made up of die castaluminiumhousing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including electronic driver and making electrical connection, complete all as specified and as directed by the Engineer-in-Charge.Cat part No.ENDURASUNDOWNSL25WLED765PASYBOTGIHD of make Havells or equivalentin make given in Appx \"B\". |
| 8 | Supply and fixing in repair, service bracket of mild steel pipe 25 mm bore medium grade of length 0.70 mtr fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts and washer and suitable reducer for connecting fitting to GI pipe as required at site includingtwo coats ofsynthetic enamel paintoverone coat of red oxide primer on mild steel work, complete all as specified and as directed by the Engineer-in-Charge. |
| 9 | Supply and fixing MCB SP, 6-32 Amps, 240 volt,10 KA ,\"B\" curve as per site requirement including removing old unserviceable MCB , complete all as specified and as directed by the Engineer-in-Charge. Cat Part No 811008 of make Indo Asian or equivalentin make given in Appx \"B\". |
| 10 | Supply and fixing MCB SPN 32 Amps, 240 volt,10 KA ,\"B\" curve as per site requirement including removing old unserviceable MCB , complete all as specified and as directed by the Engineer-in-Charge. Cat Part No 811034 of make Indo Asian or equivalentin make given in Appx \"B\". |
| 11 | Supply and fixing in repairMCB three pole and neutral 415 Volts, 63-100 Amps, 16 KA, 50 Hz thermal adjustable type , complete all as specified and directed by the Eng-in-charge. Cat Part No 811220 of make Indo Asian or equivalentin make given in Appx \"B\". |
| 12 | Supply and fixing sheet metal enclosure Vertical triple pole & neutral(VTPN) IP-43 including MCCB 125 Amp, 16 KA, 415 volts, 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and includinglugs/thimbles duly crimped for connectionincluding making smooth the disturbed surface including removing old unserviceable enclosure, complete all as specified and as directed by the Engineer-in-charge. Cat part No.811888 of make Indo Asian or equivalentin make given in Appx \"B\". |
| 13 | Supply & fixing Polycarbonate thermoplastics Vertical TPN distribution board including MCCB 125 Amp, with breaking capacity 16 kA, in accordance with IEC 61439-3 which should be shock proof, Protection Class-I, earthed. IP65 in accordance with IEC 60529 (EN 60529), weather proof, flame retardent, Corrosion free, Acid & Chemical Resistant, Impact resistant, Ultra Violet resistance, made of halogen and silicon free recyclable material. The DB shall have high grade internally embedded gasket made of Polyurethane ( PUR ) with provision for cable entry through integrated flanges top. The entire system should have hinged door and it can be combination of transparent, complete all as specified and directed by Engineer-in-Charge. Cat Part No. FP VN 0400 of make Hensel or Legrand/ Schneider or equivalent make given in Appx \"B\". |
| 14 | Supply and fix sheet metal enclosure triple pole & neutral (TPN) IP-43 with including MCB 63 Amp,16 KA, 415 volts, 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and includinglugs/thimbles duly crimped for connection including making smooth the disturbed surface including removing old unserviceable enclosure, complete all as specified and as directed by the Engineer-in-charge. Cat part No.811840 of make Indo Asian or equivalentin make given in Appx \"B\". |
| 15 | Supply and fixing in repair Thermoplastics IP 65, MCB distribution board 2 ways in accordance with IEC 60670-24 which should be shock proof and double insulated. IP65 in accordance with IEC 60529 (EN 60529), weather proof, Corrosion free, Acid & Chemical Resistant, temperature resistance, Made of material Polycarbonate for Lid part andPS (polystyrene) for Base with transparent lid, sealable. halogen & Silicone free recyclable material, .The gasket material shall be Polyurethane, while the gasket shall be internally embedded.The enclosure is Consisting PE and N FIXCONNECT® terminal with provision for cable entry through top, bottom and sides. The impact strength of enclosure i.e. the Degree of Protection against Mechanical load shall be in accordance with IEC 62262 forIK 08 (5 Joule) And Enclosure should withstand Glow wire test at 750°C in accordance with IEC 60695-2-11 flame retardant, Self Extinguishing, UL subject 94,V-2. Color: Grey, RAL 7035.Suitable for indoor installation and outdoor installation, protected against weather influences, complete all as specified and directed by Engineer-in-Charge. Cat part No. KV7103 of Hensel or equivalent make given in Appx \"B\". |
| 16 | Supply, installing, test and commissioning factory made and tested CPRI approved, LT feeder Pillar box (KISOK), indoor type,wall mounted having suitable dimensionmade out of 2 mm thick CRCA sheet metal having independent compartment for insulated Aluminium bus bar, incoming feeder and each out going feeder suitable for Three phase meter and MCB TPN with acrylic doordust and vermin proof water proof, suitable for 3 phase 415 volts 50 Hz, AC supply, bus bar chamber with aluminium bus bar 200 Amps rating for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported epoxy insulator - 01 set, cable gland with independent plates at bottom for each outgoingand incoming cables in cable alley and complete board painted with powder coating in seimens grey colour front opening type with double door acrylic cover for meter compartment, includingtaking down and refixing of existing cable properly with lugs and thimbles. Rate including for removal and taking out existing VTPN board of any type and size, complete all as approved and comprising as under :-(a)Incoming MCCB 125 AMps, 4 Pole, 415 Volts 16 kA -01 Nos.(b)Outgoing MCB TPN 63 Amps, 415 volts, 10 kA B curve - 04 Nos.(c)Outgoing MCB SPN 10 Amps, 230 volts, 10 kA B curve - 02 Nos.(d)Digital multi meter - 01 Nos.(e)Phase indication lamp LED type with MCB SP backup - 01 Set (RYB)(f) Internal wiring with suitable copper cable with copper lugs complete.Note : Drawing of meter box panel must be approved by Engr-in-Charge. |
| 17 | Supply and fixing sheet metal MCB DB, SPN, 8 ways with 200 Amps rated bus bar single pole and neutral withdouble door IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure, complete all as specified and as directed by the Engineer-in-charge. Cat part No.811807 of make Indo Asian or equivalentin make given in Appx \"B\". |
| 18 | Supply and fixing sheet metal MCB DB, SPN, 12 ways with 200 Amps rated bus bar single pole and neutral withdouble door IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure, complete all as specified and as directed by the Engr-in-charge. Cat part No.811808 of make Indo Asian or equivalentin make given in Appx \"B\". |
| 19 | Supply and laying as in repair sub main wiring with two run of 2.5 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 2.5 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI markedmulti stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in and includingPVC conduit medium gradeISI marked of adequate size for housing the wires, complete all as specified and as directed by the Engineer-in-Charge.Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.(ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length. |
| 20 | Supply and laying as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI markedmulti stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in and includingPVC conduit medium gradeISI marked of adequate size for housing the wires, complete all as specified and as directed by the Engineer-in-Charge.Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.(ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length. |
| 21 | Supply and laying as in repair sub main wiring with four run of 10 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 10 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI markedmulti stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in and includingPVC conduit medium gradeISI marked of adequate size for housing the wires, complete all as specified and as directed by the Engineer-in-Charge.Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.(ii) Four runs of cable and one run of PVC conduit shall be measured and paid as one unit length. |
| 22 | Supply and fixing electronic meters temperproof LCD display with polycarbonate cover 230V, 10-60 amps, accuracy class-I 50 Hz, conforming to IS 13779, IP-54 with parameters to show data , time, current reading, load, PF, voltage and kWH, complete all as specified and directed by Engineer-in-Charge. Cat part No. ER300P of make L & T or equivalent make given in Appx \"B\". |
| 23 | Supply, Laying and testing in trenches or passing through pipe for cableXLPE insulated, armoured heavy duty electric cable with multistranded aluminium conductor 1100 volts grade 4 core of size 25 Sq.mm., complete all as specified and as directed by the Engineer-in-Charge. |
| 24 | Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc. and getting out for soft/loose soil, complete all as specified and directed by the Engineer-in-charge. |
| 25 | Supply and laying GI tubes light grade with connected fittings laid in trenches/wall/ pole for protection to UG cables of size 40 mm dia., complete all as specified and as directed by the Engineer-in-Charge. Make: Surya/Jindal/TATA |
| 26 | Material and labour for cushioning for protection of cable using dry river sand, free from particles, complete all as specified and directed by the Engineer-in-charge. |
| 27 | Material and labour for Protection to cable with one layer of new bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks, complete all as specified and directed by Engineer-in-charge. |
| 28 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm for soft/loose soil, complete all as specified and as directed by the Engineer-in-charge. |
| 29 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed by the Engineer-in-charge. |
| 30 | Material and labourt for PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in coping of road cutting / hard standing width not more than 0.30 m and depth 0.15m, complete all as specified and as directed by the Engineer-in-charge. |
| 31 | Material and labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5 mtr below the normal ground level connected to galvanised earthwire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron. Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to earthing test pointas directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/cboth ways with one handle for liftingmade out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing as in repair, complete all as directed by Engineer-in-Charge and earth testing on completion . |
| 32 | Material and labour for taking down existing light fitting of any type alongwith GI pipe/ pole of any dia / any size and supply and fixing of MS pipe (Hot dipped Galvanized) decorative pole in two sections i.e Top pipe not less than 70 mm outside dia x 1500 mm long and Bottom pipe not less than 110mm outside dia x 500 mm long, thickness of pipe not less than 3 mm with base plate 250 x 250 x 12mm thick having 14mm dia hole for fixing of foundation \"J\" bolts of size 12mm dia x 450 mm \"J\" including 115 x 200 mm long utility window in pole, including material & labour for fixing of suitable size nuts/bolts and washers including Tripple layer metallic PU paint (Etching, Epoxy & PU) having Embalishment aluminium castiing suitable for and alongwith 30/35 Watt Warm white LED post top lantern IP 65 environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs clear cover offers bright illumination including all fixing accessoreis including necessary excavation, removal and PCC 1:3:6 work as directed etc., complete all as specified and directed by the Engineer-in-charge. Cat Part No. HLPTP-95-2M-114/76-ACE-HDG of make Halonix or equivalent make given in Appx \"B\"Note :(i) Quoted rates shall be inclusive of excavation, taking down existing pole, all fixing acessories & PCC 1:3:6 for fixing of pole & post top lantern.(ii) Drawing of pole must get approved before installation..(iii) MS pipe of pole (Top & Bottom) should be ISI marked as per latest standard. |
| 33 | Note:-Amount of credit ofRs. 81,720.00for retrieved materials is mentioned in Schedule of Credit Page No…………………. of tender documents in pdf form which will be deducted offline while acceptance of tender. |