| 1 | Material and labour for servicing of flame proofEOT Crane capacity 2/3/5 ton by the following method as follows : (a) Replacement of gear oil in gear boxes .(b) Grease the whole crane(c) Before filling the gear boxes clean the gear box inside and outside by using diesel (d) Checking the wheel condition(e) If thruster breaks are used check the level of oil in it and if required to be refilled, refill the same (f) Check the working of the break if required to change then change the same(g) Checking the connection of motors (h) Checking the condition of motor if required to rewind, then rewind the same (j) Checking the condition of couplings if required to be change then change the same (k) Check the nuts & bolts fitted on the crane, if required to be change then change the same (l) Check the condition of the power cables fitted on the crane, if required to be change then change the same.(m) Check the break shoe fitted on the break of the crane, if required then change the same (n) Check the limit switch fitted on the crane , if required then replace the same .(o) Check the step down transformer, single phase preventer, terminal block, MCB, HRC and DBR, if required to be change then change the same. (p) If VED installed, check the same and if required then replace the same (q) Check the pendant, if element and push button required to be change then replace the same . Note :(for item No 01 to 03)(i) All unserviceable spare parts to be replaced shall be measured and paid separately under relevant item of Sch A. (ii) Cost of Grease shall be deemed included in unit quoted rate. Note: (iii) Maintenance and servicing of EOT crane to be carried out twice throughout the CA duration. Qty are considered accordingly. (iv) Load testing of flame proof EOT Crane comprising two number tests for each crane i.e. Capacity test and Brake Test by putting the requisite load, writingdate of test and next due date for testing on the crane with white synthetic enamel paint over a black strip of synthetic enamel paintcomplete all as directed. (v) Material and labour for Load testing shallbe arranged by the contractor at his own and the rate of this item include the cost thereof.(vi) Testing of particular crane shall be scheduled by Engineer-in-Charge.(vii) Load testing and caliberation of EOT crane carried out in the presence user rep & Engineer-in-Charge. |
| 2 | Description all as per item No 1 abovebut capacity of crane 10 ton complete all as directed |
| 3 | Description all as per item No 1 abovebut capacity of crane 20 ton complete all as directed |
| 4 | Supply & fix in repair FRLS, 4 core 6 sqmm PVC insulated PVC sheathed multistranded copper conductor cable on the existing conduit/carrier all as specified and directed by Engr-in-charge. |
| 5 | Supply & fix in repair FRLS, 4 core 4 sqmm PVC insulated PVC sheathed multistranded copper conductor cable all as specified and directed by Engr-in-charge. |
| 6 | Supply & fix in repair FRLS, 6 core 2.5 sqmm PVC insulated PVC sheathed multistranded copper conductor cable all as specified and directed by Engr-in-charge. |
| 7 | Supply & fix in repair/replacement FRLS, 12 core 1.5 sqmm PVC insulated PVC sheathed multistranded copper conductor cable |
| 8 | Material and labour for disconnecting electric connections of3 phase motor 0.5/0.75/1 HP capcity, 415 Volts AC supply of EOT crane,taking out from the crane, dismantling / opening of motor, cutting and taking out burnt winding wire, cleaning of slots by removing dust etc. andrewinding with super enamelled copper winding wire of existing gauge and class of insulations as per original manufacturers design including varnishing replacing insulation papers insulated sleeves etc. complete reassembling and reinstalling and testing on full load complete all as specified and directed. |
| 9 | Description all as per item No 8 here-in-before but Motor capacity of 1.5/2 HP complete all as directed |
| 10 | Description allas per item No 8 here-in-before but Motor capacity of 3 HP complete all as directed |
| 11 | Description allas per item No 8 here-in-before but Motor capacity of 5/7.5 HP complete all as directed |
| 12 | Description all as per item No 8 here-in-before but Motor capacity of 10 HP complete all as directed |
| 13 | Description allas per item No 8 here-in-before but Motor capacity of 20 HP complete all as directed |
| 14 | Supply & fix in repair/replacement limit switch for LT/CT motion suitable for 2 Ton/ 3 Ton/5 Ton/ capacity EOT cranecomplete all as specified and directed. |
| 15 | Supply & fix in repair/replacement limit switch for LT/CT motion suitable for 10 Ton capacity EOT crane complete all as specified and directed. |
| 16 | Supply & fix in repair/replacement limit switch for LT/CT motion suitable for 20 Ton capacity EOT crane complete all as specified and directed. |
| 17 | Supply & fix in repair/replacement hoist limit switch suitable for 5/10/20 Ton capacity EOT crane complete all as specified and directed. |
| 18 | Supply& fix in repair/replacement break liner pad of LT,CT and Main Hoist motion suitable for 2 to 20 Ton capacity EOT crane all as directed Engineer-in-charge. |
| 19 | filling of Gear oil ( ISI Marked ) of 80W-90 gradein gear boxes upto specified level under the relevent item of the schedule complete all as specified and directed. |
| 20 | Hydraulic oil (ISI Marked ) of approved grade for filling in the electrohydraulic thruster upto specified level complete all as specified and directed.. |
| 21 | Supply & fix in repair/replacement Transformer of capacity 250 VA having primary side 0-415 volt and secondary side 0-110 V AC complete all as specified and directed. |
| 22 | Supply & fix in repair/replacement Transformer of capacity 1500 VA having primary side 0-415 volt and secondary side 0-230 V AC complete all as specified and directed. |
| 23 | Supply & fix in repair/replacement , HRC fuse, round type, upto 16 Ampscomplete all as specified & directed by Engineer-in-charge. |
| 24 | Supply & fix in repair/replacement MNX 18 Amps, power contactor suitable for 3 phase, 415 volts, 50 Hz AC. complete all as specified and directed by Engineer-in-charge. |
| 25 | Supply & fix in repair/replacement MNX 25 Amps, power contactor suitable for 3 phase, 415 volts, 50 Hz AC. complete all as specified and directed by Engineer-in-charge. |
| 26 | Supply & fix in repair/replacement, Power contactor MNX 32A Coil Volt-240Vcomplete all as specified and directed by Engineer-in-charge. |
| 27 | Supply & fix in repair/replacement, push botton switch with (element and all connection) 220 Volts, suitablefor 2/3/5/10/20 ton crane capacity all as specified and directed by Engineer-in-charge |
| 28 | Supply and fix in replacement ofPush button station with 6/8 Way switches including emergency stop and mains ONwith suitable size of gland for cable entry/exit, hanging arrangements complete all as specified and directed by Engineer-in-charge. |
| 29 | Supply and fix in replacement of Flame proof push button station with 12 Way switches including emergency stop and mains ONwith suitable size of gland for cable entry/exit, hanging arrangements complete all as specified and directed by Engineer-in-charge. |
| 30 | Supply and fix in repair/replacement of roller bearing suitable for 2 Ton crane complete all as specified and directed by Engineer-in-charge, |
| 31 | Supply and fix in repair/replacement of roller bearing suitable for 3 Ton crane complete all as specified and directed by Engineer-in-charge |
| 32 | Supply and fix in repair/replacement of roller bearing suitable for 5 Ton crane complete all as specified and directed by Engineer-in-charge, Cranex |
| 33 | Supply and fix in repair/replacement of roller bearing suitable for 10 Ton crane complete all as specified and directed by Engineer-in-charge. |
| 34 | Supply and fix in repair/replacement of roller bearing suitable for 20 Ton crane complete all as specified and directed by Engineer-in-charge. |
| 35 | Supply and fix in repair/replacement of thrust bearing suitable for 2 Ton crane complete all as specified and directed by Engineer-in-charge, |
| 36 | Supply and fix in repair/replacement of thrust bearing suitable for 3 Ton crane complete all as specified and directed by Engineer-in-charge. |
| 37 | Supply and fix in repair/replacement of thrust bearing suitable for 5 Ton crane complete all as specified and directed by Engineer-in-charge. |
| 38 | Supply and fix in repair/replacement of thrustbearing suitable for 10 Ton crane complete all as specified and directed by Engineer-in-charge. |
| 39 | Supply and fix in repair/replacement of thrustbearing suitable for20 ton crane complete all as specified and directed by Engineer-in-charge. |
| 40 | Supply and fix in repair/replacement of wheelbearing suitable for2 ton crane complete all as specified and directed by Engineer-in-charge. |
| 41 | Supply and fix in repair/replacement of wheelbearing suitable for 3 ton crane complete all as specified and directed by Engineer-in-charge. |
| 42 | Supply and fix in repair/replacement of wheel bearing suitable for 5 ton crane complete all as specified and directed by Engineer-in-charge. |
| 43 | Supply and fix in repair/replacement of wheel bearing suitable for10 ton crane complete all as specified and directed by Engineer-in-charge. |
| 44 | Supply and fix in repair/replacement of wheel bearing suitable for20 ton crane complete all as specified and directed by Engineer-in-charge. |
| 45 | Supply and fix in repair/replacement of gear boxbearing suiable for2/3 ton crane complete all as specified and directed by Engineer-in-charge. |
| 46 | Supply and fix in repair/replacement of gear box bearing suitable for5 ton crane complete all as specified and directed by Engineer-in-charge |
| 47 | Supply and fix in repair/replacement of gear box bearing suitable for10 ton crane complete all as specified and directed by Engineer-in-charge. |
| 48 | Supply and fix in repair/replacement of gear box bearing suitable for20 ton crane complete all as specified and directed by Engineer-in-charge. |
| 49 | Supply and fix in repair/replacement of steel wirerope suitable for EOT crane of capacity 2/3/5/10/20 ton with all connected fitments and includinggreasing and testing all as specified and directed by Engr-in-charge. |
| 50 | Supply and fix in repair/replacement of EOT crane wheel suitable for 2 to 20 ton crane complete all as specified and directed by Engineer-in-charge |
| 51 | Supply and fix in repair/replacement ofcable carrier trolley for2/3/5/10/20 ton crane complete all as specified and directed by Engineer-in-charge |
| 52 | Supply and fix in repair/replacement of crane hoist brakesuitable for2 to 20 ton crane complete all as specified and directed by Engineer-in-charge |
| 53 | Supply and fix in repair/replacement of hydraulicThruster Motorsuitable for2/3 ton crane complete all as specified and directed by Engineer-in-charge |
| 54 | Supply and fix in repair/replacement of hydraulic ThrusterMotor suitable for5/10 ton crane complete all as specified and directed by Engineer-in-charge |
| 55 | Supply and fix in repair/replacement of hydraulic Thruster Motorsuitable for20 ton crane complete all as specified and directed by Engineer-in-charge |
| 56 | Supply and fix in repair/replacement of rubber buffer suitable for2/3/5/10/20 ton crane complete all as specified and directed by Engineer-in-charge |
| 57 | Supply and fix in repair/replacement of Gear wheel suitable for 2/3 ton crane complete all as specified and directed by Engineer-in-charge |
| 58 | Supply and fix in repair/replacement of Gear wheel suitable for 5 ton crane complete all as specified and directed by Engineer-in-charge |
| 59 | Supply and fix in repair/replacement of Gear wheel suitable for 10 ton crane complete all as specified and directed by Engineer-in-charge |
| 60 | Supply and fix in repair/replacement of Gear wheel suitable for 20 ton crane complete all as specified and directed by Engineer-in-charge |
| 61 | Supply and fix in repair/replacement of Oil sealsuitable for 2/3/5/10/20 ton crane complete all as specified and directed by Engineer-in-charge |
| 62 | Supply and fix in repair/replacement of gasket suitable for 2/3/5/10/20 toncomplete all as specified and directed by Engineer-in-charge |
| 63 | Supply and fix in repair/replacement of Variable frequency drive suitable for2/3ton crane complete all as specified and directed by Engineer-in-charge |
| 64 | Supply and fix in repair/replacement of Variable frequency drive suitable for5ton crane complete all as specified and directed by Engineer-in-charge |
| 65 | Supply and fix in repair/replacement of Variable frequency drive suitable for10 ton crane complete all as specified and directed by Engineer-in-charge |
| 66 | Supply and fix in repair/replacement of Variable frequency drive suitable for20ton crane complete all as specified and directed by Engineer-in-charge |
| 67 | Supply & fix in repair/replacement MCB 6-32 Amps ,SP, suitable for 240 V, 10 KA,\"C\", 50 Hz, AC.all as directed by Engineer-in-charge |
| 68 | Supply & fix in repair/replacement MCB SPN 40 to 63 Amps, suitable for 240 V, 10 KA,\"C\", 50 Hz, AC.all as directed by Engineer-in-charge. |
| 69 | Supply & fix in repair/replacement MCB SPN 32 Amps, suitable for 240 V, 10 KA,\"C\", 50 Hz, AC.all as directed by Engineer-in-charge. |
| 70 | Supply & fix in repair/replacement MCB TPN/FP 16 to 32 Amps, suitable for 415 V, 10 KA,\"C\", 50 Hz, AC all as directed by Engineer-in-charge |
| 71 | Supply & fix in repair/replacement, MCB TPN 40 to 100 Amp 415 V,10 KA,\"C\", 50 Hz, ACcomplete all as specified and directed by Engineer-in-charge. |
| 72 | S&F in repair, MCCB TPN 25 to 100 Amps 16 KA complete all as specified and directed by Engineer-in-charge. |
| 73 | S&F in repair, MCCB TPN 125 Amps 36 KA complete all as specified and directed by Engineer-in-charge. |
| 74 | Supplying & laying jointing and testing LTXLPEinsulatedgalvanized steel wirearmorued electric cable 1100volt grade heavy duty ISI marked with aluminium conductorof cross sectional area 10 Sqmm 4 Core with the wall/ beam/ pipe/passing through pipes or laid under floor/ducts of through walls etc complete all as specified and directed by Engineer-in-charge. |
| 75 | Supplying & laying jointing and testing LTXLPEinsulatedgalvanized steel wirearmoured electric cable 1100volt grade heavy duty ISI marked with aluminium conductorof cross sectional area 16 Sqmm 4 Core with the wall/ beam/ pipe/passing through pipes or laid under floor/ducts of through walls etc complete all as specified and directed by Engineer-in-charge. |
| 76 | Supplying & laying jointing and testing LTXLPEinsulatedgalvanized steel wirearmoured electric cable 1100volt grade heavy duty ISI marked with aluminium conductorof cross sectional area 25 Sqmm 4 Core with the wall/ beam/ pipe/passing through pipes or laid under floor/ducts of through walls etc complete all as specified and directed by Engineer-in-charge. |
| 77 | S&F in repair, indicator lampLED type complete all as specified and directed by Engineer-in-charge. |
| 78 | Repair to Gear box of 2/3 Ton (LT /CT/Hoist ) by replacement of any acessories like shaft,oil seal, pinion or any other connected items refixing and checking testing complete all as specified and directed by Engineer-in-charge. |
| 79 | Repair to Gear box of 5 Ton (LT /CT/Hoist ) by replacement of any acessories like shaft,oil seal, pinion or any other connected items refixing and checking testing complete all as specified and directed by Engineer-in-charge. |
| 80 | Repair to Gear box of 10 Ton (LT /CT/Hoist ) by replacement of any acessories like shaft,oil seal, pinion or any other connected items refixing and checking testing complete all as specified and directed by Engineer-in-charge. |
| 81 | Repair to Gear box of 20 Ton (LT /CT/Hoist ) by replacement of any acessories like shaft,oil seal, pinion or any other connected items refixing and checking testing complete all as specified and directed by Engineer-in-charge. |
| 82 | Material and labour for cleaning and preparation of steel surfaces of existing dull painting of flame proof EOT crane indoor/ outdoor type with complete assembliesetc. and applying two coats of synthetic enamel paint (Heat/fire resistant type) according to IS colour code by spray machine including writing MES/SM No in capital letters of suitable size on body for capacity 2/3 ton complete all as specified and directed .Note :- (i) Cost of paint shall be deemed included in unit quoted rate.(ii) Flame proof EOT crane are fixed at different locations and at a height approx 20 feet. Painting thereof shall be carried out after getting the permission of authorities. Tenderer shall keep this aspect while quoting the rates. |
| 83 | Descriptionall as per item No 82abovebut capacity of 5/10 ton complete all as directed |
| 84 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 |