| 1 | Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc. but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and as directed. |
| 2 | Taking down cement or cement lime plaster from brick walls etc including raking out joints, hacking for key scrubbing down with water etc.all as specified |
| 3 | M&L for brick work with fly ash bricks (old size), straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified & directed by Engineer-in- charge. |
| 4 | All as per item 03 here in before but except bricks |
| 5 | M&L rendering 15mm thick on fair faces of brick work or concrete surfacesin CM 1:4 finished even & smooth without using extra cement all as specified. |
| 6 | Rendering 15mm thick on brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement all as specified. |
| 7 | Rendering 10mm thick on brick or concrete surface as in ceiling in cement mortar 1:3 finished even and smooth without using extra cement all as specified. |
| 8 | Demolition of Trellis work (Jafri)/ RCC Jallies, including taking as under of battens in trellis in one way complete all as specified & directed by Engineer-in- charge. |
| 9 | M&L25 mm thick precast cement concrete 1:2:4, type B-0, louvres and jalliesset in cement mortar 1:4 including all mould frame complete all as specified & directed by Engineer-in-charge |
| 10 | M&L applying two coat of cement base paint over one coat of primer on new plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer - in – Charge. |
| 11 | M&L applying two coat of Oil emulsion distemper over 1.5mm thick wall care putty on new plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer - in – Charge. |
| 12 | M&L for applying three coats of white washing on ceilingincluding preparation of newly plastered surfaces complete all as specified. |
| 13 | Taking down chowkats or frame with shutters (without taking off shutters from the frame) not exceeding 1.50 sqm each & removing to store all as specified and directed. |
| 14 | M&L for Granite (of any type) tiles 16mm to 18mm thick, machine-cut, fixed all around window openings (including sill, jambs and lintel), bedded and jointed with grey cement slurry and pointed with white cement mixed with approved pigment to match the shade of granite; including edge rounding/chamfering as required, and machine polishing to a smooth finish. Granite to be laid on a 15mm thick screed bed or bedding layer in cement mortar (1:6), complete all as specified. |
| 15 | Providing and fixing factory made uPVC white colour casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with mitlti chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling ol holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild sleel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) [and 6mm thick glazing with selected quality glass.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) |
| 16 | S&F 6mm thick Toughned glass as in hinged doors, partitions, automatic doors, windows and similar work including cutting to shape, drilling holes required. |
| 17 | Dismantling posts or struts (wood, steel or R.C.C.) any section embedded in concrete, brick work, masonry etc. including taking out embedded portion and making good disturbed ground complete all as specified and as directed. |
| 18 | Dismantling expanded metal, any thickness or mesh, fixed with steel or wood fillets, if any n.exc 4 Kg |
| 19 | M&L PCC in foundations, filling and mass-concrete type C2 (1:3:6) using 40 mm graded stone aggregate |
| 20 | M&L Mild steel work posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets, round bars with screwed ends etc. (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 21 | S&F Mild steel screw bolts (machine made) with hexagonal / square heads at one end & screwed the other/ screwed both ends, each screwed end to be fitted with washers & one hexagonal or square nut, n exc 5cm long dia of shank 5 to 10 mm |
| 22 | S&F chain link fencing of MS GI wire mesh of size 100 x 100mm, 3.2mm dia of GI wire mesh upto into mattresses or cages lapped wired incl.staple etc complete all as shown on drgs. |
| 23 | M&L Expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members |
| 24 | M&L Preparation of new steel and iron surface of any description over 10cm in width or girth and applying 2 coats of synthetic enamel paint over a coat of red oxide primer complete all as specified |
| 25 | M&L Painting of new steel surfaces of any description not otherwise described n.exc 10cm in width or girth including preparation of surfaces,priming with red oxide zinc chrome primer finished with two coats of synthetic enamelwhen unconnected with other painting or when painted in different tint completecomplete all as specified. |
| 26 | Demolitionof cement concrete ( un re-inforced) of any description in ground floor and pavings Nexc15 cm thickness (below or above GL) |
| 27 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), remving serviceable tiles to stores and and rubbish off the permises. |
| 28 | M&L 75 mm thickPCC 1:4:8 type D2 using 40 mm graded aggregate as in sub base all as specified. |
| 29 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; size and shape as per requirement at site complete all as specified and directed. |
| 30 | M&L 18-20mm thick machine cut kota stone slab (table rubbed and polished) as in flooring laid over and including 15 mm thick screed bed or bedding layer in CM (1:4), set and jointed with grey cement slurry mixed with pigment to match the shade of slab including cutting, rubbing, grinding and mirror polishing upto desired satisfaction of Engr In Charge complete all as specfied and directed. |
| 31 | M&L for coloured chequered cement concrete tiles 30cm x 30cm x 25mm thick glossy finish, set, jointed & pointed in neat cement slurry in in floors with grey cement & pigment over 15mm thick screed in CM (1:6) complete all as specified. |
| 32 | M&L Providing, cement concrete type B-1 20mm graded aggregates in roof kerbs or mud stops, rounded or chamfered on edges |
| 33 | M&L cement concrete type B-1, 1:2:4 using 20mm graded stone aggregate as in floors 25 mm thick for tilesall as specified.& directed by Engineer -in-charge.. |
| 34 | Repairing the existing rolling shutter of minimum size 3.00 Sqm or more (or as installed), which includes opening of the shutter, checking alignment, greasing/oiling of shaft and guide channels, tightening/adjusting the spring, and replacing worn-out or damaged parts such as ball bearings, MS side channels, locking pins, handle, lath strips or any other unserviceable components as required. After repair, refixing the shutter in proper working condition including preparation of old steel surface and applying one coat of metal primer and two coats of synthetic enamel paint, complete all as directed |
| 35 | Preparation of old steel surface of existing steel post (up to 15 m height) by scraping, wire-brushing and cleaning to remove rust, dust and loose paint, and applying one coat of metal primer followed by two coats of synthetic enamel paint of approved shade to achieve a smooth and durable finish, complete all as directed.” |
| 36 | Repairing the damaged steel ladder of the overhead water tank of approximately 14–15 m height, including cutting out broken/unserviceable portions of MS flats and round bars, straightening bent members, welding new MS flats/rungs/side supports as required, replacing corroded or missing parts, providing necessary MS brackets/cleats, grinding all welded joints, and refixing the ladder firmly in position for safe use. The work also includes preparation of the old steel surface and applying one coat of metal primer followed by two coats of synthetic enamel paint, including all necessary formwork, scaffolding, and safety arrangements, complete as directed.” |
| 37 | Preparation of the existing concrete surface of the overhead water tank of approximately 15–20 m height by cleaning, removing dust, loose paint, laitance, and other foreign matter through wire brushing, scraping, and washing. Apply one coat of suitable primer/sealer for concrete surfaces, followed by two or more coats of approved exterior emulsion paint applied in camouflage pattern as per approved design, ensuring uniform coverage and smooth, aesthetically accurate finish. The work shall include all necessary formwork, scaffolding, access arrangements, and safety measures required for execution at height, complete as directed.” |
| 38 | S&F in repair galvanised, 2-strand steel barbed wire, 2.24 mm dia with 2 mm dia barbs at 75 mm spacing, including straining and fixing to any type of standard rails, straining bolts, and securing/tying at crossings with galvanised MS wire, staples or steel pins complete as directed (each line wire to be measured). The work also includes removing and taking down the existing old/damaged barbed wire complete. |
| 39 | M&L applying one coat of cement base paint on old decorated plastered surfaces of walls including preparation of surfaces by washing, rubbing down and stopping of painted surfaces upto 15m height complete all as specified and directed by Engineer - in – Charge |
| 40 | M&L for preparation of old painted concrete surfaces of any description over 10 cm width or girth in road side kerbs, edges etc. and applying one coat of plastic emulsion paint all as specified and directed by Engineer - in - Charge . |
| 41 | M&L for preparation of old painted steel surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint all as specified and directed by Engineer - in - Charge . |
| 42 | M&L for preparation of old painted steel surfaces of any description n exc. 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint all as specified and directed by Engineer - in - Charge . |
| 43 | Preparing old white washed surfaces of wall (plastered or unplstered) for white washing and applying one coat of white wash upto 15m height complete all as specified. |
| 44 | Preparing old white washed surfaces of ceiling (plastered or unplstered) for white washing and applying one coat of white wash upto 15m height complete all as specified. |
| 45 | Dismantling plain, corrugated steel sheeting any guage, thickness including nanital or similar pattern roof covering complete all as specified and as directed by Engineer-in-charge. |
| 46 | S&F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specifiedand as directed by Engineer-in-Charge. |