| 1 | Subwork-I Shed Item no.1 Clearing grass and removal of rubbish up to a distance of 50 metres outside the periphery of the area |
| 2 | Item No.2 Excavationfor foundation/pipe trenches in hard murum including removing theexcavatedmaterialuptoadistanceof50M and liftsasbelow, stackingandspreadingasdirectedbyEngineer-in-charge, normaldewatering, preparing the bed for foundation and excluding backfilling, etc.complete.(Bd-A-2/259. |
| 3 | Item No.3:-Providing dry trap/granite/quartzite/gneiss,rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting etc.complete(Bd-A-12/264) |
| 4 | Item No.4:- Providing and laying in situ cement Concrete and M-15 / laying in of trap/ granite / quartzite gneiss metal for foundation bedding including bailing out water, form work, compaction, curing, etc. complete. |
| 5 | Item No.5:-Providing and fixing in position steel reinforcement bar of various diameters for RCC piles, caps, footings, foundations,slabs, beams, columns, canopies, staircases, newels, chajjas, lintels,pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack weldingand supporting as required, etc. complete(including17/306)cost. |
| 6 | Item No.6:-Providing and laying in situ Cement Concrete of trap/ granite / quartzite /gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Concrete M-25 for Footing |
| 7 | Item No.7:-Providing and casting in situ Cement Concrete of trap/ granite / quartzite /gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineerin-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or reinforcement) Concrete M-25 For Column |
| 8 | Item No.8:-Refilling the trenches with available excavatedstuffwithsoftmaterial firstover pipelineand thenhardmaterial in15cm layers with all leads and lifts including consolidation,surcharging,etc.complete |
| 9 | Item No.9:- Providing and fixing in position steel reinforcementbar of various diameters for RCC piles, caps, footings, foundations,slabs, beams, columns, canopies, staircases, newels, chajjas, lintels,pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack weldingand supporting as required, etc. complete(including17/306)cost. |
| 10 | Item No.10:-Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement |
| 11 | Item No.11 :-Filling in plinth and floors / trenches with contractor\"s murum for bedding in 15 cm to 20 cm layers including watering and compaction, etc. complete.Bd-A-11/263) |
| 12 | Item No.12:-Provide first class burnt Brick masonry with conventional/1.S. type brick in cement mortar 1:6 in plinth including bailing out water manually, Striking joints on unexposed faces, pointing with cement mortar 1:3 on exposed face and watering etc. Complete. |
| 13 | Item No.13:-Providing internal cement plaster of 20 mm. Thick in single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface in all positions Including scaffolding and curing etc. Complete. |
| 14 | Item No.15:-Providing and applying plastic emulsion paint of approved quality,colourandshadeto newsurface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete |
| 15 | Item No.16:-Providing structural steel work in rolled sections like joists, channels, angles, tees, etc. as per detailed designs and drawings including fixing in position without connecting plates, braces, etc and one coat of anticorrosive paint and over it two coats of oil painting, of approved quality and shade, etc. complete (Bd-C-2/275) |
| 16 | Item No.17:- Providingand fixingcolour coatedZincalume( R ) AZ150 (min 150 gms/sq.mt. total oneachside profiledsheetsforroofing.Thefeedmaterialismanufacturedoutof nominal0.45mmBaseMetalThickness(BMT)(0.5mmTCT),Hi-strengthsteelwith min.550MPayieldstrength, metallic hot dip coated with Aluminium-Zinc alloy (55%aluminium43.4%zinc1.6%silicon)withCOLORBOND(R)steelqualitysuper durablepolyesterpaintcoat (withinorganic pigment). The paint shall have a total coating thickness of nominal35um,comprisingofnominal25umexteriorcoatontopsurfaceandnominal10umreversecoatonbacksurface.Profilesheetshallhavenom.950-1050mmeffectivecoverwidthandnominal25-30mmdeepribswithsubtlesquareflutinginthefivepanatnominal180-250mmcenter-to-center. Theend rib shall be designed for anti-capillary groove. and return leg. The feedmaterialshouldhave coilmanufacturers product detailsmarkeda regular interval. Including fastenerswithmin. fastenedwithmin. 25umZinc-Tinalloycoated,Hexhead, self drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) |
| 17 | Item No.18:-Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/One Running Metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/One Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/One Running Metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating without box |
| 18 | Item No.19:-Providing and fixing M.S. grill 24 Kilogram/ One Square Metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc |
| 19 | Item No.20:-Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle sectionfitted with sliding bolts and handles for both sides, deep M.S. channel section of depthand thickness not less than 65 mm and 3.15 mm respectively with hold fastarrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape withsquare bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet notless than 0.9 mm thickness and of any size at top and safety devices includingmechanical gear operation arrangement consisting of worm gear wheels and worms ofhigh grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S.62481979) (Without mechanical gear) |
| 20 | Item No.21:-Providing and fixing board displaying information, such as \"Name of work, Tender cost, Name of Contractor,Work completion and liability period etc\", having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation,refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge. |
| 21 | Sub Work-II Electric Work:- Item No:-1 Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 22 | Item No:-2 Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 23 | Item No 3:-Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 24 | Item No.4:- Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 25 | Item No 5:-Supplying, erecting & marking DPMCB 6 A to 32 A B- series (for lighting) in provided distribution board as per specification no. SW-SWR/MCB |
| 26 | Item No.6:-Supplying, erecting & marking SPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 27 | Item No 7:-Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification No. SW-SWR/MCB |
| 28 | Item No 8:-Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification No. SW-SWR/MCB |
| 29 | Item No 9:-Supplying and erecting regular/ standard model ceiling fan of 1400mm. Sweep complete erected in position as per specification no. FG-FN/CF. |
| 30 | Item No.10:-Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation |
| 31 | Item No.12:-Supplying and erecting anodized aluminium light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs at L70B50 including driver with end caps on provided PVC Block/wooded board with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 32 | Item No.13:-Supplying, erecting & terminating XPLE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Please Enable Macros to View BoQ information |