| 1 | Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below.(ii) Amount of Schedule of credit shall be deducted offline |
| 2 | Dismantling structural steel work includingpurlins, tursses complete all as specified and directed. |
| 3 | Dismantling of asbestos cement (corrugated, semi corrugated etc.) sheets in roof coverings, including ridge complete all as specified and directed. |
| 4 | Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demolition) in any description and in any position not other wise specifically provided for complete all as specified and directed. |
| 5 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons, walls, etc, laid bedded and pointed in any mortar complete all as specified and directed. |
| 6 | Surface excavation not exceeding 30 cm deep and averaging 15cm and getting out complete all as specified and directed. |
| 7 | M&L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc.15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 8 | M&L forcement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as infoundation , filling, subbase and mass concrete complete all as specified and directed. |
| 9 | M&L for fly ash brick work with sub class B bricksstraight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed. |
| 10 | M&L for 15mm thick rendering in CM 1:4 faces of brick or concrete surfaces, finished fair, even and smooth without using any extra cement complete all as specified and directed. |
| 11 | M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm incl prep of new surface complete all as specified and directed. |
| 12 | Removing surplus soil obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting paint completeall asspecifiedand directed. |
| 13 | M&L for heavy duty flooring tiles , harsh weather & UV resistance, high abrasion resistance, MOH hardness >6 thickness of 10 mm thick , area of each tile not less than 0.09 sqm , anti slip type, laid in floors , steps, edges etc set and jointed in neat cement slurry and pointed in white or coloured cement to match tile with & including 15 mm thick rendering in CM 1:4 complete all as specified and directed |
| 14 | M&L for cement concrete type B-1, 1:2:4 using 20 mm graded stone aggregate as in bed blocks, copings, kneelers, apex stones, bed plates, lintels and the like etc complete all as specified and as directed. |
| 15 | S&Ffor steel work in tubular/angle trusses including special shaped washers, purlins, rafters, postsetc complete all as specified and directed. |
| 16 | S&F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheeting 0.50 mm thick of any colour having tensile strength of 550 Mpa (AZ-150) as in roof covering / cladding to wall, chajjas, etc. and fixed with self tapping screws complete all as specified and directed |
| 17 | S&F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheeting 0.50 mm thick of any colour having tensile strength of 550 Mpa (AZ-150) as in ridges, hips, valley gutters, drip, straight flashing etc. (length and gith as fixed) and fixed with self tapping screws complete all as specified and directed |
| 18 | S&F for mild stell work in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed |
| 19 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed |
| 20 | Cutting holes in brick walls not exc 1 brickwall in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required |
| 21 | M&L for preparation new steel & iron surfaces of any descriptionover 10cm in width or girth and applying twocoat of synthetic enamel paint over and including a coat of red oxide zinc chrome primercomplete all as specified . |
| 22 | M&L for 25mm thick PCC 1:2:4 type B-0 using 20 mm graded stone aggregate, as in levelling course , complete all as specified and as directed. |
| 23 | M&Lfor vitrified ceramic tile light shade 8-10 mm thick (square /rectangular) polished, area of each tile not exceeding 0.36 Sqm as in floors/skirting over and including 20mm thick screed bed in CM 1:6 etc and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles compeleteall as specified & directed. |
| 24 | M&L for galvanised cold rolled steel section frame work size 600x600 grid size 24x38x0.50 (composite thickness) Tee (bottom pre-coated ) and size 24x24x0.50m (composite thickness) thick wall angle , galvanised cold rolled steel section including suspenders as per (Gapsec) manufacturs insturction as in ceiling complete all as specified and directed. |
| 25 | M&L for asbestos free calcium silicate board of size600x600x6mm thick fixed to steel frame work as in ceiling, including applying two coats of oil bound distemper complete all as specified and directed. |
| 26 | M&L for fabricating and fixing powder coated (minimum 50 miciron ) aluminium sections of required size for doors, windows any type, frames and partitions including aluminium hinges of required size jointing cleats, screws salsh fasterners, plug for fixing with walls, column etc including taking down damage portion of damage door, windows complete all as specified and directed. Note :- Rates are inclusive of necessary new fitting for door/ window/partio i.e handle, tower bolt, butt hinges, beading etc complete |
| 27 | S&F for 4.8 mm thick sheet glass, ordinary quality fixed in aluminum doors/partions in square exc 0.5 sqm in each pane complete all as specified and directed. |
| 28 | S&F for 3mm thick aluminum composte panel (ACP), exterior grade, PE core, PVDF coated of approved shade complete all as specified and directed. |
| 29 | S&Fin repairs PVC(SWR) pipes 110mm dia, single socketed, in any length with rubber ring joints laid in trenches, floors or fixed in walls complete all as specified and directed. |
| 30 | S&F PVC (SWR) 110mm bore,bends any radius complete all as specified and directed. |
| 31 | Demolition or breaking up of salt glazed ware, AC or reinforced concrete drain pipes, 150 mm dia jointed in cement mortarandtakingout of trenches, if required complete all as specified and directed. |
| 32 | S&F for 150mm dia (DWCPE Pipe) class SN-8 structural wall polyetylene (Pipe with online coupler and elastomeric rubber ring ) with hollow annular smooth outer surface and a smooth inner surface ( double wall plain ) for non pressure unerground drainage and sewage application Type B nomial size ( Dn /ID )made of polyethylene ( PE ) material confirming to ISI 6098 ( Part II : 2013 and to be transported handledinstalled and joied asper Annex A Of ISI 6098 ( part II :2013 complete all as specified and directed. |
| 33 | M&L for concrete bed to drain pipes 150 mm dia incl packing under, and haunching against the sides of pipes after they are laid and tested in 1:4:8 type D2 (using 40 mm graded stone aggregate)complete all as specified and directed. |
| 34 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathedFRLS cable 1100 volts grade, ISI-694 marked with valid CML No.in and including medium grade, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc,ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), with sheel metal ms flesh box, white cover plate with frame for fixing modular switches, sockets and fan regulators etc, including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core FRLScable as earth continuity conductor to common earth and connecting to earth dollycomplete all as specified and directed. |
| 35 | All as per item No 33.00 above, but for 3 pin 6 Amp socket outlet on independent board complete all as specified and directed. |
| 36 | All as per item No 33.00 above, one 3 pin socket outlet6 Amps on same boardall as specified and directed. |
| 37 | All as peritem No.33.00 above, but 3 pin socket outlet 16 amps on independent board elect wiring 2.5 sq mmcomplete all as specified and directed. |
| 38 | S&F modular switch, single pole, one way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. |
| 39 | S&F in repairs ceiling rose surface bakelite, three terminals, 240V, 50Hz, ISI marked completeall as specified and as directed. |
| 40 | S&Fmodular switch socket combination 6 pin 3 module, 16 amp,240 volt , ISI Marked AC complete all as specified and as directed. |
| 41 | S&Fmodular switch socket combination 6 pin, 3 module, 6 amp,240 volt ISI Marked AC complete all as specified and as directed. |
| 42 | S&Fmodular socket outlet, 2 module, multipurpose having provision for 2 & 3 pin, 6/16 Amp,240 volt ISI Marked AC complete all as specified and as directed. |
| 43 | S&F in repairLED tube light fitting, surface mounted lumanaires, 1 x 20 W, 240V, decorative ultra slim round /squar profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack with bipin holders, LED lamps, connector block, etc. complete with all accessories internally pre-wired and including connecting up with flexible copper conductor cable of suitable size complete all as specified and directed. |
| 44 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep minimum air delivery 210 CFM with service value 6.00 BEE. five star rated with brushless direct current motor (BLDC) all as specified and directed. |
| 45 | S&F sheet metal enclosurefor SPN DB ( single pole and neutral) single door type,surface mounted concealed inwall12 ways, 240 Volts, IP 43, ISI marked 200 amps bus bar dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed. Make:HPL Electric/ Havells/ Indoasian or any approved. NOTE:- MCB shall be measured and paid separately. |
| 46 | S&F in repairs MCB SP, 240 volts, 10 KA breaking capacity, \"C\" curve, of capacity 6 to 32 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed. |
| 47 | S & F in repairs MCB SPNsuitable for 240 volts, AC supply32 Amps, C Curve,with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. |
| 48 | M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section areaand drawing into rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 20mm external diameter and PVC insulated stranded copper conductor of 4.0 sqmm nominal cross section area as earth wire complete all as specified and directed. Note :(i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 4.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length. |
| 49 | M&L for earthing complete with galvanised steel earth plate electrode 600×600× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing testpoint all as specified or indicated including testing on completion complete all as specified and as directed. |
| 50 | S&F of LED 36 watt recess mountinglight fitting (2 x 2 luminaire),with white powder coated CRCA housing with high power LEDs and aluminium front frame with flat white high power transmission acrylic coverincluding connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make :- Bajaj cat part No. BZRSQL 36W LED GX WH or equivalent in Philips/ Crompton. |
| 51 | S&F for building security light fitting 35 Wattmade up of pressure die-cast alluminium housing with high efficient LED as lighting source and pc over having top opening separate driver compartment with IP-66 protection and impact resistance of IK07 including suitable galvanized iron pipe \"light grade\" brackets 1 mtr length bent to shape to obtain required shape including clamps, nuts/bolts/washers etc connecting with suitable copper wire of size 23/0.0076 complete including all accesories ( bracket, clamps for fitting on wall) complete all as specified and directed. |
| 52 | Deduct schedule of credit (calculation will be done off line)Rs. 12908.75 |