| 1 | (a) Wall panel/ cladding: M&L for pre fabricated wall paneling made of stainless steel 304grade with 50 to 60mm thick puff insulation with pressure injected of rigid polyurethane foam minimum density 40 kg/cum, sandwiched between inner and outer (front side) stainless steel sheeting having 1.20mm thickness and 0.80mm pre-painted GI on back side. The wall panels to be fixed with C channels/ U channels thread rod and other accessories required for proper fixing with metal grid frame work sufficient enough to withstand the entire wall panelling work, incl making/ cutting necessary opening if any required as per site conditions for fixing switch boards/ gas pipe line/ electrification works and equipment etc.(b) Joints: The individual wall panel shall use the tongue and groove/ suitable technology for minimum number joining two panels with of junctions. No welding shall be allowed, the gaps between wall panels to be filled with metallic epoxy filer and sanded fush giving seamless appearance and finished to fine grain surface to the entire wall paneling. The angular comers to be made with 130o - 140o angular modular element. |
| 2 | (c) Anti Bacterial Paint: The stainless steel wall paneling to be painted with dry film thickness of minimum 300 microns over primer. The paint to be anti-bacterial, anti-microbial & anti-fungal, resistant to UV lights, disinfactants, steams, fumigation agents etc painting to be applied by approved, applicator with air-less spray gun. Color and tint of paint shall be as approved the painting protection and prevention of the growth of mould bacteria and yeasts for 5 years to be given by the manufacturer. The wall panels shall be CE/ UL/ ETL/ FDA/ ISO 13485 certified/ listed. Test report from for stainless steel & properties of paint will be submitted by the contractor at the time of pre-dispatch inspection/ supply, complete all as specified and directed.Note: Wall paneling to be provided flushed with storage cabinet/ space side and size of grid for wall paneling will be fixed accordingly. |
| 3 | M&L for point wiring 1.5 Sqmm (nominal cross sectional area) with colour coding multistranded copper conductor cable, PVC insulated (FRLS-H) and unsheathed cable and including drawn through existing conduit of casing capping with all fittings and accessories, terminated to existing sunken box/ PVC box with PVC top sheet and providing new laminated sheet as per site requirement of suitable size for housing/mounting the switches/ sockets including 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable earth wire connected to common earth dolly for one light/ fanpoint control by one, one way switch, complete all as specified and as directed. |
| 4 | All as per Srl item No 2.00 above but one 3 pin socket oulet 5 amps, onsame board with other switches, complete all as specified and as directed. |
| 5 | All as per Srl item No 2.00 above but one 3 pin socket oulet 5 amps, onindependent board, complete all as specified and as directed. |
| 6 | All as per Srl item No 2.00 above but for one 3 pin 15 Amps power point on independent board with 2.5 Sqmm complete all as specified and directed |
| 7 | All as per Srl item No 2.00 above but for one 3 pin 15 Amps power point on independent board with 4.0 Sqmm complete all as specified and directed |
| 8 | All as per Srl item No 2.00 above butin PVC Casing-N-Capping 25 x32 mm complete all as specified and directed. |
| 9 | All as per Srl item No 7.00 above but for one Bell/ Buzzer point controlled by one push switch on independent board, complete all as specified and directed. |
| 10 | All as per Srl item No 7.00 above but one 3 pin socket oulet 5 amps, onsame board with other switches, complete all as specified and directed.. |
| 11 | All as per Srl item No 7.00 above but one 3 pin socket oulet 5 amps, on independent board, complete all as specified and directed. |
| 12 | All as per Srl item No 7.00 above but for one 3 pin 15 Amps power point on independent board with 2.5 Sqmm, complete all as specified and directed |
| 13 | All as per Srl item No 7.00 above but for one 3 pin 15 Amps power point on independent board with 4.0 Sqmm complete all as specified and directed |
| 14 | S&F switch piano flush single pole, one way 5 Amp ( ISI marked),complete all as specified and directed. |
| 15 | S&F switch piano flush single pole, one way 15 Amp ( ISI marked)complete all as specified and directed. |
| 16 | S&F socket (ISI Marked) 2 in 1, 3 pin 5/6 amps flush type complete all as specified and directed. |
| 17 | S&F socket 2 in 1, 5 pin 5 and 15 amps (ISI marked) flush type universal complete all as specified and directed. |
| 18 | S&F ceiling rose, 3 phase, PVC polycarbonate, insulated body (ISI Marked) complete all as specified and directed. |
| 19 | M&L for lamp holder (Angle) PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 20 | S&F LED 14 watt complete all as specified and directed. |
| 21 | S&F LED inverter batten with fixture, 1x 20 watt, (4 Feet) wall mounted, with PC housing and diffuser, IP20 complete including electrical connection with copper cable from ceiling rose to fittings and including taking down existing fittings complete all as specified and directed. |
| 22 | S&F LED inverter batten with fixture, 1x 10 watt, (2 Feet) wall mounted, with PC housing and diffuser, IP20 complete including electrical connection with copper cable from ceiling rose to fittings and including taking down existing fittings complete all as specified and directed. |
| 23 | S&F in replacement 36/40W LED (Size 2\"x2\") square shapedRecess mounting type luminaries having white polycarbonate body & Alumium heat shink with PMMA diffuser, 5700K, IP54including connecting three core copper cable up to ceiling rose complete all as specified and directed. |
| 24 | M&L for submain wiring with 2X6.0Sqmm+1X6.0Sqmm Earth Wire single core PVC insulated FRLS-H PVC sheathed cooper cableconnecting to common earth dolly in and including heavy duty PVC Concealed Conduit as per site requirement and direction by EIC, with all accessories complete all as specified and directed. Note: Three runs of copper wire for phase, neutral, earth & one run PVC conduit/ casing shall be measured one unit length, complete all as specified and directed. |
| 25 | All as per Srl item No 23.00 above but 2 run of single core 4 Sqmm FR PVC insulated unsheathed multistranded copper conductor cable and one run of 4.0 Sqmm FR PVC insulated unsheathed multistranded copper conductor earth wire, complete all as specified and directed. |
| 26 | S&F sheet metal enclosure MCB DB 12 way,SPN, IP-54, double door, suitable for 240 V fixed flushed on walls including cutting Knitch and making good disturbed surfaces complete all as specified and directed. |
| 27 | S&F sheet metal enclosure MCB DB 8 way, SPN, IP-54, double door, suitable for 240 V fixed flushed on walls including cutting Knitch and making good disturbed surfaces, complete all as specified and directed. |
| 28 | S&F MCB SP (single pole) 06 to 32 Amps, \"B\" Curve with 10 kA for inductive load connected through cable lugs of suitable size complete all as specified and directed. |
| 29 | S&F MCB SPN/ DP (single pole and neutral) 32/40 Amps \"B\" Curve with 10 kA for inductive load connected through cable lugs of suitable size, complete all as specified and directed. |
| 30 | S&F MCB SPN/ DP (single pole & neutral) 240 volt 63 amps \"B\" Curve with 10 kA for inductive loadconnected through cable lugs of suitable size, complete all as specified and directed. |
| 31 | S&F in repair Surge protection device (SPD) voltage protection level up upto 1.3 kV, suitable for protection of all terminal equipments both common & differential mode protection complete all as specified and directed. |
| 32 | S&FMCB protected socket 15/20 Amp including 25 Amp MCB suitable for domestic and commercial use geyserwith PVC box, sheet steel enclosure (ISI marked) flush type complete all as specified and directed. |
| 33 | S&F in repair PVC conduit of 25mm dia, complete all as specified and directed. |
| 34 | S&F in repair PVC casing capping of 25mm (1\") width, complete all as specified and directed. |
| 35 | S&F in repair Single core PVC Insulator with copper stranded Conductor Cable 1100V grade ISI size 4.0 Sqmm complete all as specified and directed. |
| 36 | S&F in repair single core PVC Insulator with copper stranded Conductor Cable 1100V grade ISIsize 6.0 Sqmm complete all as specified and directed. |
| 37 | Taking down carefully (Medical related lights and others) by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc etc to be measured separately , removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc, (To be measured only when found serviceable in all respects complete for reuse), complete all as specified and directed. |