| 1 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes,etc n exc 10 Sqm on plan and n exc 1.5m in depth and getting out in hard/dense soil complete. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm in any type of soil complete all as specified and as directed |
| 3 | Removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point all as specified ans as directed |
| 4 | M&L for Plain Cement Concrete1:4:8 type D2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete all as specified and as directed |
| 5 | M&L for Reinforced cement concrete (Design Mix) inM-30 for foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified. |
| 6 | M&L for form work to sides of rough finished concrete foundations, foootings, bases of columns, raft and raft beams, sides and soffits if any of foundation and plinth beams and similar work vertical or to batter compelte all as specified and as directed. |
| 7 | M&L for Reinforced cement concrete (Design Mix) inM-30 for columns, pillars,piers,posts and struts,complete all as specified. |
| 8 | M&L for form work to sides of Pillars, posts, struts, piers,columns and sanctions complete all as specified and directed |
| 9 | M&L for Reinforced cement concrete(Design Mix) inM-30 for Beams, cantilevers, bressumers, lintels over 1.5m span, complete all as specified. |
| 10 | M&L for form work to sides and soffits of rough finished floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs,etc alos splays between floors, and beams,etc compelte all as specified and as directed. |
| 11 | M&L for Reinforced cement concrete (Design Mix)in M-30 in Slab supported on walls, beams and columns in floors, roofs, landings, balconies canopies, deck slabs and in shelves and the like complete all as specified. |
| 12 | M&L forform work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick(Horizontal or sloping) all as specified. |
| 13 | M&L for form work to edges of concrete flats, treads, breaks in floors, window cills,concrete railings,opeinings in concrete walls, floors and roofs n.exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and smimilar work all exceeeding 10cm wide and n.exc 20cm wide with rough finished surfaces. |
| 14 | M&L for Reinforced cement concrete(Design Mix) M-30 in Chajjas complete all as specified. |
| 15 | M&L for form work to chullah hoods, chajjas, troughs and similar items including edges,etc compelte all as specified and as directed |
| 16 | M&L for TMT bars 10mm dia and over as in reinforcement cut to length, bent to shape required including cranking hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing clips compelte all as specified and as directed |
| 17 | All as per item No 17 above but6 mm to 8mm dia. |
| 18 | M&L for TMT bars 5mm dia and over upto and incl 10mm dia in stirrups, spacers, and binders in reinforcement cut to length, bent to shape required including cranking hooking ends and binding with mild steel wire compelte all as specified and as directed. |
| 19 | M&L for 5mm thick cement plaster in cm (1:3) on top of roof slab with water proofing compound compelte all as specified and as directed |
| 20 | M & L for roof treatmentwith following specification completely, complete all as specified and as directed :-(i)Applying evenly a tack coat of bitumen primer @ 0.3 kg/ sqm.(ii) Laying a coat of hot bitumen 85x25 @ 1.2kg per sqm.(iii)Laying APP modified membrane weighting not less than 3 to 4 kg/sqm in 100 mm over laps both longitudinally and transversally and overlaps to be sealed by torch, membrane shall be taken upto the thickness of slab/front fascia.(iv) Cleaning the surfaces and finally painted at the top with a coat of bituminous aluminium paint @ 100gms/Sqm over bituminous coat all as specified and as directed |
| 21 | M & L for Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices,skirtings, drip moulds and similar work exc 15 cm but n exc 30 cm in width or girth; including cutting to edges, all mi- tres and stopped ends, etc. compelte all as specified and as directed |
| 22 | M & L for Plain cement concrete type B1 (Using 25mm graded stone aggregate as in coving complete all as specified and as directed |
| 23 | Material & Labour for Moorum/Red BajriFilling in floors or pavings, laid in layers n exc 15cm thick, spread, levelled and rammed including watering and compelte all as specified and as directed |
| 24 | M & L for hardcore of gauge not exceeding 63 mm of broken granite stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface compelte all as specified and as directed. |
| 25 | M&L precast cement concrete block masonry with PCC solid blocks in 1:3:6 type C1 using 20mm graded stone aggregates, exc. 10cm in width and set in CM 1:4 complete all as specified and directed. |
| 26 | M/L for precast cement concrete solid block masonary with solid blocks using PCC 1:3:6 type C1 using 20mm graded stone aggregate n.exc 10cm in width and setting in cement mortar (1:4)etc complete all as specified. |
| 27 | M&L for rendering 15mm thick on fair faces of brick/concrete surface in CM (1:6) finished even and smooth without using extra cement all as specified and as directed |
| 28 | M&L for externalrendering 15mm thick in CM 1:4 with on fair faces of brick work or concrete surfaces finished even and fair with water proofing compound (water proofing compound shall be used as per manufacturers instructions) complete all as specified and as directed.Note : WPC measured and paid separately. |
| 29 | M&L for rendering to ceiling in 5mm thick on fair faces concrete surface in CM (1:3) finished even and smooth without using extra cement complete all as specified and as directed. |
| 30 | Supply only water proofing compound confirming to IS-2645 1975 |
| 31 | M&L for providing PCC 1:4:8 type D2 (40mm graded stone aggregate) as sub base 100mm thick compelte all as specified and as directed |
| 32 | M&L for 25mm thick PCC(1:2:4) type B1 using 20mm graded stone aggregate as in flooring finished even and smooth using extra cement compelte all as specified and as directed. |
| 33 | Material and labour forceramic coloured tiles, Non skid,area of each tile exc 0.18sqm and not exc 0.38sqm (square / rectangle) 7 to 8mm thick mm thick, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick cement screed in CM 1:4 all as directed. |
| 34 | All as per item No 34 here in before, but on vertical surfaces including 10mm thick CM 1:3 as in baking coat of dado/skirting compelte all as specified and as directed |
| 35 | M&L for Non skid ceramic colured tiles each tile area (square/rectangle) exc 0.06Sqm but not exceeding 0.11Sqm tile thickness 7 to 8 mm, in floors etc set and joined in neat cement slurry and pointed in white or coloured cement to match incl screed bed or bedding layer with CM 1:4 15mm thickfor laying floor finishes all as specified . |
| 36 | M&L Glazed ceramic tiles coloured350x 250x 7 mm/ 450X 350X 7mm thickthick on vertical surfaces such as skirting, dado etc set and jointed in neat cement slurry and pointed in white or coloured cement to match.incl 10mm thick in CM 1:3as backing coat for fixingdadotiles all as specified. |
| 37 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and as directed |
| 38 | S&F Factory Made Solid panel PVC door shutter30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing |
| 39 | M & L for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Zsections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size,including necessary filling up the gaps at junctions, i.e. at top,bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions |
| 40 | M & L for Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions. |
| 41 | Supply & fix stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples compelte all as specified and as directed. |
| 42 | M & L for 4mm thick figured glass,pin head type and glazing with oil putty in squaresn exc 0.5sqm in each pane all as specified and as directed. |
| 43 | M & L 12 mm thick pre-laminated particle board, exterior grade, pre-laminated on one side with decorative choice lamination and other side white lamination fixed to Aluminium frameetc all as specified and directed. |
| 44 | S & F 200mm long aluminiumanodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed |
| 45 | M&L 100mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 46 | S & F Butt hinges,100mm size medium weight,cold rolled mild steel,and fixed completeall as specified and as directed |
| 47 | S&F aluminium handles, cast type, anodised 150mm long complete all as specified and as directed. |
| 48 | S&FVitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe)complete all as specified and directed. |
| 49 | Supply and fix low level PVC valveless, syphonic action type, flushing cistern, 10 litres capacity, white with inlet, ball valve, float and handle including brackets complete all as specified and as directed |
| 50 | S&FHealth faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 51 | S & F Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) |
| 52 | Supply and fix vitreous china wash basin, white, flat back size 550 x 400mm inluding cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe all as specified and as directed |
| 53 | Supply and fix PVC Connections 15mm size with PTMT nuts of length 750mm all as specified and as directed |
| 54 | S & F Bib taps, 15mm, fancy type, cast copper alloy with crutch or butterfly handle,screwed down,screwed for iron pipe or for brass ferrule all as specified and as directed |
| 55 | S & F Pillar taps, 15mm, fancy type, cast copper alloy with capsten heads,chromium plated,screwed down high pressure, screwed for iron pipe and fixed all as specified and as directed |
| 56 | S & F stop valve, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed but fancy type chromium plated, 15mm bore all as specified and as directed |
| 57 | S & F Brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges all as specified and as directed |
| 58 | M&Lfor 20 mm bore unplasticised PVC pipes of pressure rating 10 Kgf/Sqcm fixed complete to walls, ceilings or in floors etc any type of pipe all as specified and as directed. |
| 59 | M&Lfor 15 mm bore unplasticised PVC pipes of pressure rating 10 Kgf/Sqcm fixed complete to walls, ceilings or in floors etc any type of pipe all as specified and as directed. |
| 60 | S&F rotational moulded polyethylene water storage tank, ISI markedof capacity 1000 ltrs hoisted and fixed in position all as specified. |
| 61 | S & F20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed, minimum weight 142 gms, complete all as specified and directed |
| 62 | S&F 20mm dia nipple of PTMT, suitable for HDPE water tank, min weight 45 gms, complete all as specified and as directed. |
| 63 | S & F Harrison rails of anodised aluminium alloy fixing with brackets, stops,rollers etc all as specified and as directed |
| 64 | S & F 1400mm x 800mm x 6mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and as directed |
| 65 | M & L for PVC (SWR) gully traps 125 x 110 mm, settingand jointingwithsolvent cement including concrete pedestal etc complete |
| 66 | S & F 110mm bore,PVC (SWR) Tee any radius, fitted with oval access door all as specified and directed |
| 67 | S & F 110mm bore PVC (SWR) bends any radius compelte all as specified and as directed |
| 68 | S & F for PVC (SWR) bends 110mm any radius, with access door complete all as specified and as directed |
| 69 | S & F PVC (SWR) vent cowl of size 110mm bore dia complete all as specified and as directed |
| 70 | S & F for PVC (SWR) pipes 110mm single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and as directed |
| 71 | S & F 75mm bore PVC (SWR) pipes single socketed, in any length, fixed to walls/laid in floors compelte all as specified and as directed |
| 72 | M & L 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed |
| 73 | M & L for treating the backfill in contact with foundation at the rate of 7.5litre of emulsion per square metre of vertical surface (Area of the sub struture in contact with backfill to be measured) |
| 74 | M & L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface compelte all as specified and as directed |
| 75 | M & L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square meter of surface area compelte all as specified and as directed |
| 76 | M & L Treating the soil along with the external perimeter of building at the rate of 2.25litre of emulsion per metre of the perimeter wall complete all as specified and as directed |
| 77 | M&L for 75mm thick plain Cement concrete1:3:6 type C2 using 40mm graded stone aggregate as in plinth protection and finished even and smooth with using extra cement compelte all as specified and as directed. |
| 78 | M&L for oil bound distempering two coats over a coat of alkali resistant priming paint including preparation of new plastered or unplasteredsurfaces of wall complete all as specified and directed. |
| 79 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirtresistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaceswith putty complete all as directed. |
| 80 | M & L for three coats of white wash on ceiling surfaces including preparation complete all as specified and as directed |
| 81 | S& F in Chromium plated shower roses 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed. |
| 82 | M & L for forming 15mm thick crumble joint filled with bituminous filler in 150mm thickness R.C.C Slab and sealed with sealing compound including cleaning of concrete surfaces all as specified and as directed |
| 83 | M & L for Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed |
| 84 | Excavation in trenches not exceeding 1.50m deep and not exceeding 1.5m width in soft/loose soil for taking out/ laying of pipe line complete all as specified and as directed. |
| 85 | Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches/ walls complete including connections of bore size of pipe 25mm dia all as specified and directed. |
| 86 | Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches/ walls complete including connections of bore size of pipe 50mm dia all as specified and directed. |
| 87 | Supply and fix Gun metal globe valves with iron wheel head screwed both end for iron pipe of sizes 25mm bore complete all as specified and as directed. |
| 88 | Supply and Fix Gun metal globe valves with iron wheel head screwed both end for iron pipe of sizes 50mm bore complete all as specified and as directed. |
| 89 | Providing Precast cement concrete Type B1 1:2:4, (20mm graded stone aggregate) in cover slabs (for manholes) and other items and set in cement mortar 1:4 complete with joints to match all as specified. |
| 90 | Material and labour for Cement concrete 1:3:6 type C-2 (using 40mm grade stone aggregate) to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, for 110mm bore PVC (SWR) drain pipes all as specified |
| 91 | Material and labour for Plain Cement Concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in coping including necessary form work all as directed. |
| 92 | M&L for point wiring concealed with multi - stranded FRLS copper conductor 1.5 Sqmm size nominal area PVC insulated unsheathed cable 1100 volts grade conforming to IS:694 drawn in and including FRLS PVC rigid conduit withnew sunk in pressed steel terminal boxes of 1.6 mm thick size or plastic gang box as per site requirement and providing new 3mm thick plastic laminated sheet cover of required colour fixed with brass screws and cup washers including single core stranded copper conductor 1.5 Sqmm PVC insulated unsheathed FRLS cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same conduit all as specified and directed for one light/fan/exhaust fan/call bell point controlled by one switch. Note : Red/Blue/Yellow for phase, black for Neutral and Green for Earth. Make of Cable : Finolex/ Havell\"s /PolycabMake of Conduit : Precision/Polycab/Anchor |
| 93 | All as per item No. 92here in before but one three pin socket outlet 5 Amps, on independent Board complete all as specified and directed. |
| 94 | All as per item No. 92here in before but one three pin socket outlet 5 Amps on the same Board complete all as specified and directed.. |
| 95 | All as per item No. 92 here in before but one 3 pin socket outlet 15 amps independent with cable 2.5 Sqmm complete all as specified and directed.. |
| 96 | Supply and FixingSwitch flush type, 5 Amps, single pole, one way and connection complete all as specified and directed.Make : Anchor/Leader/CONA |
| 97 | Supply and FixingSwitch Socket combination, 2 in 1, 3 pin 5 & 15 Amps (6 pin) flush typeand connection complete all as specified and directed.Make : Anchor/Leader/CONA |
| 98 | Supply and Fixing Socket outlet, 3/2 pin 5Ampsflush type and connection complete all as specified and directed. Make : Anchor/Leader/CONA |
| 99 | Supply and FixingCeiling Rose Surface Poly carbonate type 65 x 50 mm three terminals and connection complete all as specified and directed. Make : Anchor/Leader/CONA |
| 100 | Supply & FixingRegulator, Electronic step type,suitable for Ceiling fan and connection complete all as specified and directed. Make : Anchor/Leader/CONA |
| 101 | S&F DP MCB 32 Amps 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 15 KA breaking capacity conforms to IS/IEC 60947-2 and terminal box suitable upto 35 sqmm cable complete all as specifed and directed. Make : L&T /Schneider/Seimens. |
| 102 | Supply and fixing LED tube light fitting 1X 20W decorative ultra slim linear LED with extruded aluminium environmental friendly energy efficient 230V,complete with all accessories internally prewired and including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 103 | Supply and fixing LED tube light fitting 1X10W decorative ultra slim linear LED with extruded aluminium environmental friendly energy efficient 230V,complete with all accessories internally prewired and including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified ans as directed. |
| 104 | S&F LED Light fitting 1 x 9 W/ 10 W bulkhead luminaire including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 105 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 245 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)complete all as specified and directed. |
| 106 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louverscomplete all as specified and directed. |
| 107 | S&F Sheet metal enclosure for DB\"s double glazed door IP-43 Single pole & neutral 240 V, 8 way with cable end box conforming to IS-8623-1 & 3, IEC 61439-1 &3 made in CRCA sheet steel, RAL 9003 powder coated ready to use DB\"s provided with 100 A insulated phase bus bar, neutral bar with shrouds, earth bar, sticking saddles, cement spill protector, colour coded interconnection wire set, cable ties, blanking plates and circuit identification label with provision for DP MCB as incomer and SP MCBs as outgoing complete all as specified and directed. Make : L&T /Schneider/Seimens. |
| 108 | S&F Sheet metal enclosure for DB\"s double glazed door IP-43 Vertical Triple pole & neutral 415 V, 4 way with cable end box conforming to IS-8623-1 & 3, IEC 61439-1 &3 made in CRCA sheet steel, RAL 9003 powder coated ready to use DB\"s provided with insulated vertical phase bus bar, neutral bar with shrouds, earth bar, sticking saddles, cement spill protector, colour coded interconnection wire set, cable ties, blanking plates and circuit identification label with provision for 3/4 pole MCCB as incomer and SP/TP MCBas outgoings complete all as specified and directed by Engr-in-Charge. Make : L&T /Schneider/Seimens. |
| 109 | S&F DP MCB 32 Amps 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 15 KA breaking capacity conforms to IS/IEC 60947-2 and terminal box suitable upto 35 sqmm cable complete all as specifed and directed. Make : L&T /Schneider/Seimens. |
| 110 | S&F singlepole MCB 6 to 16 Amps 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 15 KA breaking capacity conforms to IS/IEC 60947-2 and terminal box suitable upto 35 sqmm cable complete all as specifed and directed. Make : L&T /Schneider/Seimens. |
| 111 | Earthing complete with galvanised steel earth plate electrode 60x60cm x 6mm thick, buried directly in ground earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 15 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of boits, nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 112 | Supply, laying and testing service connection through cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core all as specified and directed. |
| 113 | M&L for cushioning for protection of cable using dry river sand, free from particles all as specified and directed complete all as specified and directed.. |
| 114 | M&L for Protection to cable with one layer of new bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks/fly ash bricks all as specified and directed. |