| Sl. No. | Item Description |
| 1 | Surface excavation n. exc. (not exceeding 30 cm deep and avg 15 cm deep) and getting out in sof/loose soil complete all as specified and directed. |
| 2 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil, complete all as specified and as directed . |
| 3 | M&L for Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soils complete all as specified and directed. |
| 4 | M&L for Removal of excavated material soil to a distancenot exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 5 | Excavation over areas n. exc.1.5m deep and getting outin hard/dense soil complete all as specified and as directed. |
| 6 | Excavation over areas exc.1.5m deep and n.exc 3.00m deep and getting outin hard rock complete all as specified and as directed. |
| 7 | M&L for Plain cement concrete 1:4:8 type D-2 by using 40 mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified and as directed . |
| 8 | M&L for 40 mm thick cement concrete type B-0 1:2:4 (using 12.5 mm graded crushed stone aggregate) as in damp proof course to horizontal or vertical surfaces including nessary formwork (using WPC paid seperately in respective item) etc complete all as specified and as directed. |
| 9 | Use and waste Formwork to sides & soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors & beams, etc. Rough finished surfaces of concrete flat, complete all as specified and as directed. |
| 10 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) and similar works fair finished surfaces of concrete complete all as specified and as directed. |
| 11 | M&L for formwork to Edges of concrete flats, treads, breaks in floors.concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC band in walls, sloping and similar work for fair finished surfaces. Rough finished surfaces of concrete flat, complete all as specified and as directed. |
| 12 | Use and waste for formwork to faces of walls,retaining walls, abutments,parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified and as directed. |
| 13 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter of flate and fair finish surface complete all as directed. |
| 14 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions of square, rectangular or polygonal fair finished surfaces complete all as specified and as directed by Emgr-in-charge. |
| 15 | M&L for design mix RCC M-25 (using 20mm graded aggregate) as in footings, foundation beams, plinth beams, bases for columns etc complete all as specified and directed. |
| 16 | M&L for design mix RCC M-25 (using 20mm graded aggregate) as in column, pillars, piers, posts and strut etc, complete all as specified and as directed. |
| 17 | M&L for design mix RCC M-25 (using 20mm graded aggregate) as Beams, cantilevers, roof beam, floor beam, bressummers, lintels over 1.5m span, complete all as specified and as directed. |
| 18 | M&L for design mix RCC M-25 (using 20mm graded aggregate) as Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed. |
| 19 | M&L for design mix RCC M-25 (using 20mm graded aggregate) as walls, retaining walls, basement walls, ballast walls and the like, any thinkness , above top of footing, including attached pilasters and buttresses etc, complete all as specified and as directed. |
| 20 | S&F mild steel TMT bar10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed. |
| 21 | S&F mild steel TMT bar 5 dia and over upto and including 10 mm dia as in stirrups cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed. |
| 22 | S&F mild steel TMT bar6 to 8mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed. |
| 23 | M&L for 20mm dia MS rodas in steps/rungs etc complete including cutting,bending to shape asrequired.complete all as specified and directed. |
| 24 | M&L for ATT treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area, complete all as specified and directed. |
| 25 | M&L forATT treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface, complete all as specified and directed. |
| 26 | M&L forATT treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall, complete all as specified and directed. |
| 27 | M&L for carrying out water proofing treatment for roofs in the following stages - (i) Rendering 10mm thick in cement mortar (1:4), mixed with integral water proofing liquid all as per manufacturer\"s instructions over concrete surfaces finished even and smooth with out using extra cement. Note: (WPC shell be measured separately and paid for under respective item of schedule), (ii) Material and labour for UV stable single component fibre reinforced elastomeric liquid applied waterproofing membrane having solid content of 55% formulated wih PU hybrid polymers and reinforcing acrylic fibres and having sun reflectivity Index (SRI) of 106. The application of the material should be done in three coat (6 hr gap after each coat) on the substrate, applying first self priming coat at ratio of damp proof ultra and water 3:1 then 2 undiluted coat of damp proof ultra obtaining coverage @1 Itr/10 sqft in two coats (10-12 hrs gap between each coat. The vital physical and chemical parameters shall be as under. Min elongationat break of 350%, crack bridging ability of 2.5 mm @650 microns thickness, resists positive hydrostatic pressure of up to 10 bars. The material shall be appliied with brush or roller, complete in all respect as per the direction of Engr-in charge/consultant. Also, proper surface preparation along with covingat corners is must. Note: The work shall be executed by the authorized applicator of the manufacturer only. Note:- 1. The authorized applicator of manufacturer shall be approved by GE. 2. The color of final finish shall be decided by the GE |
| 28 | M&Lfor plain cement concrete 1:2:4, type B-0 (using 12.50mm graded crushed stone aggregate), as in roofpaddingover roof for making good depression / undulationand as in roof kerb to make the existing as filling in depression of roof slab, complete all as specified & directed. |
| 29 | Supply only integral water proofing compound (ISI marked). |
| 30 | Demolition of stone / boulder masonry walling, built in cement mortarincluding all quoins, arches, pillars etc and removal unserviceable materials, debris, rubbish to out side MD land complete all as specified and directed. |
| 31 | M&L for squared rubble walling, Jodhpur type, regular coursed well bonded ,bedded and solidly hearted built in cement mortar 1:6, complete all as specified and directed. |
| 32 | Extra over stone walling for hammer dressingto face stone & dressing of face beds & joints as specified of squared rubble walling Jodhpur type brought upto courses with maximum depression of face from straight edge held against the dressed surface n exc 20mm and dressing face beds and joints, complete all as specified and directed. |
| 33 | M&L for precast cement concrete solid building blocks type B1 1:2:4 (20mm graded stone aggregate) or slabs 10cm thick (with plain or interlocking joints as directed) setting in 1:4 cement mortar, complete, in walls all as directed. |
| 34 | M&L precast cement concrete block masonry using PCC 1:3:6, type C-1 solid blocks, exceeding 10 cm in width and setting in cement mortar 1:4, straight or curved on plan exceeding 6 m mean radius complete all as specified and directed. |
| 35 | M&L for 15 mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces, surfacesfinished even and smooth without using extra cement complete all as specified and directed.Note -Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures. |
| 36 | M&L for 15 mm thick rendering on other than fair faces of brick work or concrete surfaces,inCM (1:4)surface finished even and smooth without using extra cement complete all as specified and directed. Note -Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures. |
| 37 | M&L for 10 mm thick rendering on other than fair faces of brick work or concrete surfaces,inCM (1:4)surface finished even and smooth with WPC ( without using extra cement) etc, complete all as specified and directed. Note -(i) Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures.(ii) WPC shall be paid and measured sapartively. |
| 38 | M&L for 5 mm thick rendering in cement mortar 1:4 onconcrete ceiling surfaces / sunsheds / facia / RCC chajja, finished even and smooth without using extra cement, complete all as specified and directed.Note -Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures. |
| 39 | Taking down cement plaster any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified and as directed. |
| 40 | M&L for 15 mm thick rendering in CM 1:4 finished even and smooth without extra cement on stone wall surface, complete all as specified & directed. |
| 41 | M&L Rendering 10 mm thick CM (1:3) on concrete surfaces on ceiling / facia /RCC Chhaja etc all as directed & finished even & smooth, complete all as specified and directed. |
| 42 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed. |
| 43 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar |
| 44 | M&L keyed pointing in cement mortar (1:3) to squared rubble masonry coursedor un coursed complete all as specified & directed by Engineer-in-charge. |
| 45 | Earth filling under floors or in foundations including watering and consolidation, spreading and levelling in layers n.exc. 25cm thick and well ramming including watering as rerquired etc, complete all as specified and directed. |
| 46 | M&L for 100mm thick Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 47 | M&L Hardcore of gauge not exceeding 63 mm of brokenstone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, compacting with power roller, complete all as specified and as directed. |
| 48 | M&L for 100mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate), as in sub base of floor, complete all as specified and directed. |
| 49 | M&L for Cement concrete type B-1,1:2:4 (20mm graded stone aggregate) as sub base of flooring of 75 mm thick,complete all as specified and directed. |
| 50 | M&Lfor 25 mm thick cement concrete 1:2:4, type B-0 (using 12.50 mm graded crushed stone aggregate), as in base course, to receive floor finishes, complete all as specified & directed. |
| 51 | M&L for non-skid coloured ceramic tiles joint free 7 to 8mm thick (Square/Rectangular)area of each tiles exc 0.11 Sqm but n exc 0.18 Sqm in floors set and jointed in neat cement slurry and pointed incoloured cement to match including over 15 mm thick screed bed or bedding layers in CM (1:6) for laying in floors finishing ,complete all as specified and directed. |
| 52 | M&L forglazed colour ceramic tiles (premium quality) of size 250X350X7mm / 350X450X7 mm, as in vertical surface such as i.e. dado/skirtingetc, set and jointed in neat cement slurry and pointed in white or colouredcement to match the shade of tiles,over & including M&L 10mm thick backing coat in CM (1:4)complete all as specified and directed. |
| 53 | M&L for 15 to 18 mm thick udaipur green marble machine cut on cill, shelves, cooking plateform (table rubbed and polished) best quality as per sample, including &over 10 mm thick screeding in CM1:4 including rounding & double mouldlng with jointless finish of the edges, including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.providing suitabledia hole in the slab for the gas pipe, complete all as specified and as directed. |
| 54 | M&L for 18-20mm thick Black Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, slabs for oval type WHB, sink, cooking platforms and like including &over 15 mm thick screeding in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, providing suitabledia hole in the slab for the gas pipe / water supply pipes etc, complete all as specified and as directed. |
| 55 | M&L Machine cut kota stone slab flooring using 20 to 25mm thick slabs,as in shevles (single piece), shelf, cub board, almira, partation etc and other places, the size and design / pattern of slabs shall be as directed, including diagonals, inlays, borders, margins in two or more shades of slabs including rounding to edges of kota stone fixed with cement mortar 1:4 complete all as specified and as directed. |
| 56 | M&L of 18-20mm thick machine cut KOTA stone slab riser of step , skirting, dado etc(Single piece for steps), machine cut, laid over cementand jointed with grey cement slurry with pigment to match the shade of the slab, incl rubbing and Mirrorpolishing all as specified including backing coat of 10mm thick in CM (1:4) . |
| 57 | M&L for double charged vitrified ceramic tiles 9-10 mm thick light shed (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM (1:6) all as specified and as directed by Engr -in-charge. |
| 58 | Taking down chowkhats or framewith shutters (without taking of shutters from the frames) area not exc 1.5 Sqm each, complete all as directed. |
| 59 | Taking down chowkhats or framewith shutters (without taking of shutters from the frames) area exc 1.5 Sqm but not exceeding 4 Sqm each, complete all as directed. |
| 60 | Taking down steel windows and ventilators ( glazed / fly proof) of any description complete all as specified and as directed. |
| 61 | M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantFactory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.Note: (a)-For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.(b)- M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately. |
| 62 | S&F factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixingwith stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. |
| 63 | M&L for plain cement concrete 1:2:4 type B-1 by using 20 mm graded stone aggregate as in bed block for fixing of hold fast complete all as specified and as directed. |
| 64 | S&F of Box type steel ventilator with top hung shutter including hinges with steel handle, and steel peg stay, complete with glazing bars, complete all as specified and as directed. |
| 65 | All as per item No. 64.00 here-in-above,but without glazing |
| 66 | Supply andfabrication of Mild steel guard bars, grills, grating, and similar work and welded to window frames, door frames (made up of angle), balcony railing confirming to FE 290, gde E-165 etc , complete all as specified and directed.Note :- Guard bars shall be factory welded & given one shop coat of red oxide or zinc chromate primer. Cost of factory welding & Shop coat of primer is deemed to be included in quoted rates. |
| 67 | S&F galvanised mild steel wire cloth 0.56mmnominal dia of wire and average width ofaperature 1.18 mm, complete all as specified and as directed. |
| 68 | M&L for framed work as in doors or gates Fe 410-w A quality of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed. |
| 69 | S&F Anodised aluminium frame powder coated (Thickness of powder coating not less than 50 micron) for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete shall as specified. |
| 70 | S&F Anodised aluminium door/window/ventilators shutters powder coating of any colour (Thickness of powder coating not less than 50 micron) , aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and directed. |
| 71 | S&F pre powder coated aluminium decogrill all as per sample fixed to aluminium framework of windows & ventilators, complete all as specified and directed. |
| 72 | M&L for Pre powder coated aluminium push / pull type partly panelled and partly glazed door shutter (single leaf / double leaf) coating not less than 50 micron approved colours with frame having top rail of section 85.00mm x 44.45mm x 2.00mm, bottom rail of section 85.00mmx 44.45mmx 2.00mm thick, door verticals of section 85mm×44.45mm×2.00mm thick and lock rail of section 85.00 mm× 44.45mmx2.00mm thick with aluminium anodized frame of section 85mm x 44.45mmx2.0mm thick including necessary jointing cleats, glazing clips, rubber packing snap beading, screws, handle and locking arrangements etc, including 5mm thick ACP (Aluminium Composite Panel) sheet approved shade best quality on bottom panel and 5 mm thick float tinted glass on top panel includingbrass Mortice lock , Vertical type 1 No each door of size 100mm 4 levers complete all as specified and as directed. |
| 73 | S&F of Double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminum alloy sheet foundation box, main body with stainless steel cover governing pivot made of brass, other parts made of mild steel heavy duty & fixed complete all as specified and directed. |
| 74 | S&F in repairs mortice lock latch with two loovers (Vertical type) mild steel body 100mm long and fixedcomplete all as specified and directed. |
| 75 | M&L for fabrication of pressed steel cupboard shuttersusing 1.00 mm thick MS plain sheet & with frame 1.25 MM thick bent to shape incl two coats of syn enamel paint on int surfaces & two coats of hammer tone finish on external surfaces alongwith locking arrangement mortice lock handle etc complete all as specified and as directed. |
| 76 | S&F mortice lock from steel cupboard doors and fixing only of Brass body mortice lock of size 50 mm with a set of 2 keys, complete all as specified and as directed. |
| 77 | S&F in repairs Aluminium (Die cast) body Door closer hydraulically regulated, designation No 3 universal type,suitable for door shutters of 851 to1000 mm in width and of weight between 61 to 80 Kg complete all as specified and as directed. |
| 78 | S&F of Stainless steel butt hinges medium weight, cold rolled of size 100 mm size, complete all as specified and directed. |
| 79 | S&F 150mm long aluminium alloy anodised handle extruded section, complete all as specified and directed. |
| 80 | S&F 150 mm long aluminium anodised tower bolt, complete all as specified and directed. |
| 81 | S&F 200 mm long aluminium anodised tower bolt, complete all as specified and directed. |
| 82 | S&F Aluminium alloy, anodised, sliding door bolt 250mm sizewith hasp, staple (bolt type) and fixing clips of sheet,cast or extruded sections&fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed. |
| 83 | S&F of mild steel butt hinges medium weight, cold rolled of size 100 mm size, complete all as specified and directed. |
| 84 | S&F of 100mm size bright finished chromium plated steel handleof approved shape & design fixed with cadmium coated screws on the steel cupboard, kitchen cabint shutters etc, complete all as specified and directed. |
| 85 | S&F of aluminium alloy anodised sliding door bolt woth hasp and stalpe (bolt type and fixings clips of sheet cast or extruded sections and fixings bolts and sliding bolts of extruded sections and fixed 16mm dia and 300mm long complete all as specified and directed. |
| 86 | S&F 50 mm size best quality double/single door stopper of aluminium alloy body and tongue, anodised & hard rubber shoe all as per sample complete all as specified and directed. |
| 87 | M&L for 7.5cms thick machine cut Sand stone slabs in sunshades, chajjas, shelves, cills, landings, cover stones, templates, etc, n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4, complete all as specified and as directed. |
| 88 | M&L for laying 40-50 mm thick Machine cut sand stone slabs as in plinth protections laid over 20 mm thick cement sand screed in CM1:4 over 50 mm thick PCC all as specified and directed incl filling the joints of sand stone slabs with neat cement mixed with pigment to match the shade of slabs., complete all as specified and directed. |
| 89 | M&L for preparation of new plastered or unplastered surfaces of wall and applying with 1.5-2.0 mm thick wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound distemper (shade or tint as approved by GE) over & including one coat of primer on walls complete all as specified and as directedNote -i)- Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures.ii)- Paint shall be in one or more colours/ shades all as approved by GE. |
| 90 | M&L for complete removal of existing treatment and applying 2 mm thick wall care putty on wall surfaces including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound distemper paint onwall surfaces as per manufacturer’s instruction, complete all as specified and directed. Note -i)- Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures.ii)- Paint shall be in one or more colours/ shades all as approved by GE. |
| 91 | All as per item No. 89.00 here-in-above, but as on ceiling |
| 92 | M&L Figured glass 4.00 mm thick, pin head type and glazing with putty in square not exceeding 0.50 Sqm in each panecomplete all as specified and as directed. |
| 93 | S&F 5.5 mm thick tinted glass exc 0.5 sqm each pane complete fixed to aluminium frame work including rubber beading, complete all as specified and directed. |
| 94 | M&L Preparation of new plastered or un-plastered surfaces of walls and applying two coats of cement base paint over & including M&L single coat of chalk white complete all as specified and as directed. |
| 95 | M&L preparation of new or previously untreatedsteel surface of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over& including M&L singlecoat of red- oxide, zinc chrome primer complete all as specified and as directed. |
| 96 | M&L factory Made flush shutters, 35 mm thick solid core with block board core construction as per IS 2202(part-I, 1999), both side decorative type lamination. The stiles & rails shall be with out any joint and made with non- coniferous timber hard wood (Hillock/ Mirantee/ Bosum/ Benteak) with moisture content not less than 12% as per IS. The face panel comprising of ply wood or cross band and face veneers shall be glued by hot pressed process. The over all finished thickness of face panel shall not be less than 35mm while the thickness face veneer shall not be less than 0.6 mm complete all as specified and directed. |
| 97 | S&F of decorative type curtain rod stainless steel finish of pipe 22 to 25mm diawith best quality knob metal with double fitting type including stainless steel brackets fixed to walls complete with two nos decorative stainless steel knobs at each end, complete all as specified and as directed. |
| 98 | S&F 75mm long aluminium alloy anodised handle extruded section, complete all as specified and directed. |
| 99 | M&L for fabrication of powder coatedaluminium frame work as inframes for aluminium ventilators with louvers having 4 mm thick pin headed figured glassin small widths and having suitable mechanism for tilting etc including all the fittings for fixing in position completeall as per sample kept in GE Office complete all as directed |
| 100 | S&F Rotational moulded polythene water storage tanks of 1000 ltrs capacity, white three layered (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I with PTMT ball valve heigh pressure with epoxy coated aluminium rod and high density plastic ball suitable for 20mm bore pipe weight not less than 210gms including dismantling of old unservisiable PVC/RCC tank etc, complete all as specified and as directed. |
| 101 | S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe 20 mm bore and fixed, complete all as specified and directed. |
| 102 | Taking up or down 15mm bore steel tubing and connections including cleaning for refixing or credited to contractor complete all as specified and directed. |
| 103 | All as per item No 102.00 here-in-above,but size of pipe 20 mm bore, complete all as specified and directed. |
| 104 | Supply, laying, testing & commissioning of20 mm outer dia CPVC pipe,SDR-11, with all fitting (eblow, socket,tee with internal thread of brass) fixed to wall, ceiling or laid on floor / trenches, with CPVC solvent, complete all as specified and directed. |
| 105 | All as per item No. 104.00 here-in-above, but size 25 mm bore |
| 106 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing , etc. and making good, cutting exceeding 20cm girth, complete all as specified and directed. |
| 107 | Demolition of existing WC floor including PCC/ tile flooring ,traps attached to WC , lean concrete ,plaster and removing all debrises off the site completeall as directed. |
| 108 | M&L for rendering 15mm thick in cement mortar (1:4) on wall/floor surfaces of sunken floor finished even and smooth with using WPC as per manufacturing instruction including Cleaning the surfaces of sunken floor using wire brush , brooming down and washing down with water to remove dust etc. complete all as specified and directed . |
| 109 | Supply only integral water proofing compound. |
| 110 | M&L for laying a layer of 50 micron polythin film pasted with the help of suitable adhesive complete all as specified and as directed. |
| 111 | M&L for PCC (1:5:10) type E-2 with using (40 mm graded crushed stone aggregates) as in sunken floor work complete all as specified and as directed. |
| 112 | S&F of white vitreous china squatting pan \"Orissa pattern\" of size 580 mm X 440 mmwith integral foot rests and PVC \"P\" or \"S\" trap including provision of lime/ cement concrete bedding and making good surface of floor (as existing surfaces) etc,complete all as specified and as directed. |
| 113 | S&F Vitreous China wash down water closet pan (Pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including provision of lime concrete bedding white and making good floor including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device for pedestal pan complete all as specified and directed. |
| 114 | S&F of PVC valve less, syphonic action type, cistern, low level of 10 ltrs capacity, white with inlet, ball valve, float and handle including brackets,pipe of 32 mm dia and PVC connection 15mm size including cuttings of floor / wall and making good in CM (1:3) and fiishig the surfaces to match with existing complete all as specified and as directed. |
| 115 | S&F Vitreous china urinal half stall type with including providing & fixing of plugs bedding against wall in cement mortar 1:2 pointing around urinal back in cement mortar complete all as specified and as directed. |
| 116 | S&F in replacement of Wash Basins,Vitreous China pedestal Ivoery,flat back,size 550 x 400mmincluding brackets and cutting for and pinning in ends of brackets or erecting standincluduing swan neck Piller tap cast copper alloy chromium plated fancy type, with capstan heads,, screwed down high pressure, with or without lettered `Hot\" or `Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed including fixing and supply of Waste fittings, brass, chromium plated and waste pipe (32mm dia. flush pipe of polythylene of low or high density) etc, complete all as specified and as directed. |
| 117 | S&F 600 mm X 450 mm bevelled edge mirror of selected quality glass, 5-6 mm thick, with PVC frame , mounted on 6mm thick AC building board and fixed to wooden plug with CP brass screws and cup washers complete all as specified and as directed. |
| 118 | S&F of 15mm bore PVC connection for 450 mm long best quality with PTMT nuts at both ends with rubber washers, complete all as specified and as directed. |
| 119 | All as per item No. 118.00 here-in-above,but 600 mm long |
| 120 | S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and as directed. |
| 121 | S&F of 75 mm outlet dia. Of PVC (SWR) floor / nahani trap plain with grating including jointingto waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded stone aggregates etc, complete all as specified and directed. |
| 122 | S&F of 110 mm outlet dia. Of cast iron floor / nahani trap plain with grating including jointingto waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded stone aggregates etc, complete all as specified and directed. |
| 123 | M&L PVC (SWR) multifloor trap 75 mm dia with grating including jointing with solvent cement complete all as specified and directed. |
| 124 | Supply & laying 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laidin wall/ceiling/floor of suitable size including stack clamps of 50X3mm MS flat iron with bolts & nuts, complete all as specified and as directed . |
| 125 | Supply & laying 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laidin trenches of suitable size complete all as specified and as directed . |
| 126 | Supply & laying 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laidin trenches of suitable size complete all as specified and as directed . |
| 127 | S&F 110 mm bore (SWR)PVC bends any radiuscomplete all as specified and directed. |
| 128 | S&F 75 mm bore (SWR)PVC bends any radius with oval access door complete all as specified and as directed. |
| 129 | S&F of PVC (SWR), junction single, (Single T) equal or unequal 110 mm bore, complete all as specified and as directed. |
| 130 | S&F of 110 mm bore PVC (SWR) tee/branch pieceany radius compete all as specified and directed |
| 131 | S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with aluminium alloy brackets and gaurd and railing 60cm long complete all as specified and as directed. |
| 132 | M&L for Preparation ofnew plastered or unplastered surfaces of wall and applying three coats of white wash on wall surfaces complete all as specified and as directed. |
| 133 | All as per item No. 132.00 here-in-above, but as on ceiling |
| 134 | S&F SS peg set of five fixing with wall complete all as specified and directed. |
| 135 | S&F of brass chromium plated tubular towel rail 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 136 | S&F of CP bib taps 15mm dia, cast copper alloy fancy type, long body screwed for iron pipe or for brass ferrule , complete all as specified and directed. |
| 137 | S&F stop valve, 15 mm bore, cast copper alloy, chromium plated, fancy type with long shank and cup, screwed down, high pressure screwed both ends for iron pipes or for unions and fixed in pipe complete all as specified & directed. |
| 138 | S&F for Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified & directed. |
| 139 | S&F of two way angle cock chromium plated fancy type 15 mm bore /size complete all as specified & directed. |
| 140 | S&F Unplaticised PVC 40 mm bore pipes of pressure rating 10 Kg/CM2 fixed complete to wall ceilings or in floor etc including necessary specials. |
| 141 | S&F15mm bore stop valves/Angle valve, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixedcomplete all as specified & directed. |
| 142 | M&L 50 mm thick PCC 1 : 3 : 6, type C1, (by using 20mm graded stone aggregate) for plinth pretection finishing even and smooth without using extra cement, Including expansion joint every three metre and change in direction and joint to be filled with sealing compound Gde A complete all as specified and directed. |
| 143 | S&F of Shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour.(Minimum weight 40gms)complete all as specified and as directed. |
| 144 | S&F coloured toilet paper holder, vitreous China, box type complete all as specified and as directed. |
| 145 | M&L for 150mm thick PCC 1:2:4 type B-0 using 12.5mm graded stone aggregates as in platform for water tank on roof, finished the surface even and smooth with WPC complete all as specified and directed. |
| 146 | Supply & laying jointing and testing 150mm bore reinforced conctete pipes class NP-2 laid and jointed in cement mortor 1:1 complete with collars or socket/spigot type laid jointed and haunching at side in cement complete all as specified and directed. |
| 147 | Supply & laying jointing and testing 150mm dia Salt-glazed stoneware drainpipes laid in trenches and jointed complete all as specified and as directed. |
| 148 | M&L cement concrete bed to drain pipe including packing under and haunching against side of pipe after they are laid and tested in cement concrete 1:3:6 typeC-2 using 40 mm graded stone aggregate for 150 mm dia pipe complete all as specified and directed. |
| 149 | S&F of framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed. |
| 150 | M&L for 75mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate), as in sub base to floor, incl well compacting & laid to levels etc, complete all as specified and directed. |
| 151 | Supply and layingmachine pressed / factory made chamfered edge cement concrete rubberised interlocking paver block, 60mm thick with 6 mm thick top layersof anti abrasive material of M-35 grade with any colour, design & pattern, & size/ shape, as approved by GE as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thicknessmade by table vibratory method using PU mould, laid in required colour & pattern over and including M&L 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. |
| 152 | Supply and laying machine / factory made kerb stone of M-25 grade,at or near ground level, cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and directed. |
| 153 | M&L for Brickwork with fly ash old size burnt bricks, straight or curved on plan exc 6m mean radius, built in and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) in foundation, above plinth level upto two stories in all shapes and sizes all as specified and as directed by Engr-in-charge. |
| 154 | Supplu and fabrication of mild steel soft drawn binding or tying wire of 1.00 mm dia. Annealed complete all as specified and directed. |
| 155 | M&L for 75 mm dia. Cast iron (sand cast pipe) soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to wall etc, complete all as specified and as directed. |
| 156 | M&L for 100/110 mm dia. Cast iron (sand cast pipe) soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to wall etc, complete all as specified and as directed. |
| 157 | Demolition of cement concrete in ground floors and pavings n.exc 15 cm thinkness below or above ground level and removing debris out of MD land, complete all as directed. |
| 158 | Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed. |
| 159 | Taking down carefully UNSV main switch and DB\"s including MCBs of any size make, type and capacity and depositing at site as directed. |
| 160 | M&L for (concealed) point wiring complete with multistranded copper conductor 1.5 Sqmm PVC insulated unsheathed single core FRLSH cable 1100 volt grade, confirming IS 694 & colour code in conduit system of wiring,drawn through in and includingnon-metalicPVC concealed (including Cutting Chases and make good the distrubed surfaces as per existing finishes) conduit of size 20 mm or med grade as required as site, totally concealed in walls / and surface on floors / ceiling or fixed on surface of walls / columns / beam / tie beam etc by means of saddles and clips etc incl all conduit accessories / fittings / junction boxes / inspection covers etc of heavy grade, ISI marked and sunk terminal boxes of CI or 16 SWG pressed steel housing, totally concealed in walls with 3mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk / cup washers, for mounting of switches, sockets fan regulators etc incl 1.5 Sqmm FRLSH PVC insulated, unsheathed flexible multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end, suitable for One light/fan/bell point controlled by one, one wayswitch, complete all as specified and directed.Note:- The rates of chase cutting on wall done concealed conduit & making good good the distrubed surfaces as per existing finishes and steel terminal boxes are included in the unit rates |
| 161 | All as per Sr. item No. 160.00 here-in-above, but suitable forOne socket outlet 3 pin 5 amps on the same board controlled by one no 5 Amp switch. |
| 162 | All as per Sr. item No. 160.00 here-in-above, but suitable for One socket outlet 3 pin 5 amps on the independent board controlled by one no 5 Amp switch. |
| 163 | All as per Sr. item No. 160.00 here-in-above, but with using 2.5 Sq mm single core multistanded copper conductor cable (FRLSH)including 2.5 sq mm PVC insulated unsheathed stranded copper conductor(FRLSH) for common earth wire for 5 pin 15 Amp socket outlet on independent board . |
| 164 | M&L for modular point wiring complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FR-LSH cable (RYBN) 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm, single core,PVC insulated but unsheathed multi stranded copper conductor FR-LSH cable (Green) 1100 Volts grade as earth continuity wire connected to earth dollyand including modular sunken galvanized terminal boxes of same make of switch/ socket/ regulator withsleek and curvy cover plates, for mounting ofmodularswitches, sockets, fan regulators etc, complete all as specified abd as directed. |
| 165 | All as per Sr. item No. 164.00 here-in-above, but suitable for One socket outlet 3 pin 5 amps on the same board controlled by one no 5 Amp switch. |
| 166 | All as per Sr. item No. 164.00 here-in-above, but suitable for One socket outlet 3 pin 5 amps on the independent board controlled by one no 5 Amp switch. |
| 167 | All as per srl item no.164.00 here-in-before but with 2.5 sq mmFRLSH copper wire with 2.5 Sqmm FRLSH copper earth wire for indpendent 15 Amp point. |
| 168 | S&F Switch piano, flush type, single pole, one way,5/6 amps, 230 volts, complete all as specified and directed. |
| 169 | S&F Switch piano, flush type, single pole, one way,15/16 amps, 230 volts, complete all as specified and directed. |
| 170 | S&F Socket, two-in-one, 3 /5 Pin, 5/6 Amp, flush type, 230 volts, complete all as specified and directed. |
| 171 | S&F Socket, two-in-one, 3/6 Pin, 6/16 Amp, flush type, 230 volts, complete all as specified and directed. |
| 172 | S&FModularswitch flush type single pole one way 6 Amp ISI Marked,1 module, complete all as specified and directed. |
| 173 | S&FModularswitch flush type single pole one way 16 Amp ISI Marked,1 module, complete all as specified and directed. |
| 174 | S&FModularsocket outlet 2 in 1, 5 pin, 5 and 16 amp flush type, 230 Volts ISI Marked,1 module, complete all as specified and directed. |
| 175 | S&FModularsocket outlet 2 in 1, 6 pin, 5 and 16 amp flush type, 230 Volts ISI Marked,1 module, complete all as specified and directed. |
| 176 | S&F of Lamp holder, metal cased, bakelite body, 230 volts, including 9 watt LED lamps (ISI Marked) etc, complete all as specified and directed. |
| 177 | S&F Ceiling rose, two to three terminals, bakelite body, 230 volts, complete all as specified and directed. |
| 178 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including AC decorative box type with driver, holder including,copper conductor cable of suitable size from ceiling rose complete complete, 4 ft long, complete all as specified and as directed. |
| 179 | S&F bldg security LEDLight Luminaire of 35 Watts having IP 65 protection fiting made out of pressure die cast Aluminium housing, operating Voltage 140-270 Volts with in built surge protectore, toughened glass with and including GI pipe 40 mm bracket of 1.5 m in length including drilling holes, nuts & bolts 2 coats of red oxide primer on GI pipe and fixing with wall security light on building wall connecting cable, complete all as specified and as directed. |
| 180 | S&F inLED COOL White light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by the Engineer-in-Charge. |
| 181 | Taking down and refixing / Hanging only ceiling / exhaust fan (M.D. supply) and connecting up including provision of cable from ceiling rose or connector to fan, complete all as specified and directed. |
| 182 | S&FMCB, C Curve type, 10 kA, 40 Amp to 63 Amp, SPN with over load and short circuit protection, complete all as directed and directed by the Engineer-in-Charge. |
| 183 | S&F MCB, B Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection, complete all as directed and directed by the Engineer-in-Charge. |
| 184 | Supply and fixing as MCB DB SPN (double door) 8 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wallall as specified and directed by the Engr-in-Charge. |
| 185 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete all as specified and directed by engr-in-charge. |
| 186 | M&L for earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than1.5m below ground level connected to and including GI earth lead wire 4 mm dia by meansof nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 mm dia with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GIprotection pipe, test point etc. complete all as specified and directed.Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead. |
| 187 | M&L in repairs sub main wiring with 4.00 Sq mm single core multistrandredcopper conductor PVC insulated (FRLS ) and unsheathedcable passing through in and includingPVCconduit medium gradecompleate with all acessories concealed in walland making good the distrurbed surfaceof wallincl 6 Sq mm single core copperconductor cable PVC insulated and unsheathed cable as earth wire etc. complete all as specified and directed.Note :- Two runs of cable 4 Sqmmand One run of 4 Sqmmand one run of conduitshall be measured as unit length. |
| 188 | Supply, laying testing, in trenches/on wall / in duct/ through protection pipe LT UG XLPE insulated,armoured, heavy duty electric cable, aluminium coductor, 1100 V grade,croos sectional area16 sqmm 2 core etc. complete all as specified and directed.Note : Earth work and brick work measured and paid separately |
| 189 | S&F of exhaust fan, steel body AC single phase, 230V of size 300mm sweep with blades, frame and louvers including all accessories etc, complete all as specified and as directed. |
| 190 | Supply, laying testing, in trenches/on wall / in duct/ through protection pipe LT UG XLPE insulated,armoured, heavy duty electric cable, aluminium coductor, 1100 V grade,croos sectional area25 sqmm 2 core etc. complete all as specified and directed. Note : Earth work and brick work measured and paid separately |
| 191 | Supplying and laying un-reinforced precast concrete cable cover, class LV, type 2, flat, size 300x180mm x40 mm, complete all as specified and as directed. |
| 192 | Supply and lay sand for sand cushioning for cable protection in trenches all as directed and specified in SSR Part - 1.Note:. for the purpose of payment punned thicknesswill be measured etc,complete all as specified and directed.. |
| 193 | Supply and fix GI tubing medium grade of 40 mm dia for cable protection etc, complete all as specified and directed. |
| 194 | Note:- (i)- Qty\"s have been clubbed from 3 Nos sanction Job\"s, whose details as per appx NOTE:- (i)-The contract sum shall be arrived at after duducting amount of schedule of \"Credit\" from the Total quoted amount |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail