| 1 | Taking down chowkats or frames with shutters (without taking of shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each, complete all as specified and directed. |
| 2 | Demolition of cement concrete(Un reinforced)in ground floor & pavings n.exc 15 cm thickness (below or above GL) and removing debries out side MOD land, complete all as specified and directed. |
| 3 | M& L for PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate in fdn filling and mass concrete, complete all as specified and directed. |
| 4 | M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified as directed. |
| 5 | M&L for PCC 1:2:4 type B-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concrete, complete all as directed. (Fixing pole), complete all as specified and directed. |
| 6 | M& L for 40mm thick PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in flooring in size of panel 1.20x 1.20 mtr with Aluminium dividing strips, 1.5mm thick and 38mm wide, complete all as specified and directed. Note: Aluminium dividing strips, paid seperately. |
| 7 | M&L for Aluminium dividing strips, 1.5mm thick and 38mm wide, complete all as specified and directed. |
| 8 | M& L for PCC 75mm thick type C-1 ,1:3:6 using 20mm graded stone aggregate as in plinth protection, complete all specifiedas directed. |
| 9 | S & F oflayer 200 mm dia(SWR) pipes single socketed, in any length with rubber ring joints fixed to walls, complete all as specified and directed. |
| 10 | S&F of PVC SWR (200) bends any radius, comlete all as specified and directed. |
| 11 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified and directed. |
| 12 | M&L for Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 13 | S&F for Rolled mild steel sections conforming to Gde Fe-290 (Gde-165-E) as in main and cross beams, hip and jack rafters; purlins, flate where connected to common rafters and running rails & guides for sliding doors, fixed with angle cleats or other connecting plates, complete all as specified and directed. |
| 14 | M&L for preparation of new untreated steel surface of anydescriptionexc 10cm width or girth applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed. |
| 15 | Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165, complete all as specified and directed. |
| 16 | M&L for Anti-termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors etc,complete all as specified and directed. |
| 17 | S&F of stainless steel curtain rod side brackets decorative type of approved quality, complete all as specified and directed. |
| 18 | S&F in repair 25 mm dia decorative typestainless steel and decorative type and cap/finial etc & all other connected works, complete all as specified and directed. |
| 19 | Dismantling of stone slabs and tiles of any description or thickness in floors aprons etc including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 20 | M & L for Granite18- 20 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of graniteflooringincluding 20 mm thick screed bedding in cement mortar 1: 6 and all other similar works, complete all as specified and directed. |
| 21 | Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and rubbish off the primises, complete all as specified and directed. |
| 22 | M&L for double chargedVitrified Ceramic colouredtilesof size of tiles exc0.42 Sqm But Not Exc .1.0 Sqm in each tiles(square/ rectagular) polished,in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade tiles including 15mmthick screed bed layer in CM (1:6), complete all as specified and directed. |
| 23 | M&L forNon Skid ceramic coloured tiles 7 to 8 mm thickjoint free (square/ rectagular) area of each tile exceeding 0.06 sq m but not exceeding 0.11 sqm ,in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe shade of tile and laid over and inclduing 15mm thick screed bed layer in CM (1:6), complete all as specified and directed. |
| 24 | M&L for Glazed ceramic tiles in vertical surface 600x 300x7 mmthick joint lesstiles set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe shade tile over and inclduing 10mm thick rendering in CM (1:4) complete etc. (1st quality/Premium Quality), complete all as specified and directed. |
| 25 | S & F of factory made single extruded WPC (Wood Polymer Composite) solid door Frames/ Chowkhat comprising of 62 mm x 32 mm size applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum specification as per IS 15931: 2012 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast unserviceable fast/lugs/SS dash fasteners of required dia and length, complete all as specified and as directed by Engr-in-Charge. |
| 26 | S & F of factory made28-30 mm thick single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size,modulus of elasticity 850 N/mm” and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof specification as per IS 15931: 2012 and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and as directed by Engr-in-Charge. |
| 27 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed. |
| 28 | S & F of 110 mm dia(SWR) pipes single socketed, in any length with rubber ring joints fixed to walls, complete all as specified and directed. |
| 29 | S & F of 75 mm dia(SWR) pipes single socketed, in any length with rubber ring joints fixed to walls, complete all as specified and directed. |
| 30 | S&Fof PVC SWR (110) bends any radius, comlete all as specified and directed. |
| 31 | S&F of 75 mm PVC (SWR) junction single, (singl T)(equal or unequal), ordinary or inverted (spigot or socket type) or with paralle oval access doorsbranches, complete all as specified and directed. |
| 32 | S& Fof 110 mm PVC (SWR)vent cowl, complete all as specified and directed. |
| 33 | M&L of 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement,complete all as specified and directed. |
| 34 | S&F of 300mm long Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed etc, complete all as specified and directed. |
| 35 | S&Fof 125mm size Butt hinges, extruded brass, with brass hinge pin, bright polished and fixed, type B-11 etc, complete all as specified and directed. |
| 36 | S&F of200mm long Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed etc, complete all as specified and directed. |
| 37 | S&F of 150mm long floor door stopper of ,brass body and tongue with hard drawn steel spring fixed in floor etc, complete all as specified and directed. |
| 38 | S&F of 150mm long Extruded brass handles, fabricated type polished etc, complete all as specified and directed. |
| 39 | Dismantling boarding, like wall paneling or false ceiling in any description, fixed in any position with nails, complete all as specified and directed. |
| 40 | M&L for preparing old wooden surfaces of any description not otherwise described over 10cm in width or girth and applyingone coat of synthetic enamel paint, complete all as specified and directed. |
| 41 | Taking down cement plaster on brick or stone walls, etc, incl raking out joints, hacking for key, scrubbing down with water, etc & prepare to receive new plaster, complete all as specified and directed. |
| 42 | M&L for 15mm thick rendering in CM 1:6 on fair faces of brick work, surfaces finished even and fair without using extra cement, complete all as specified and directed. |
| 43 | M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work, with mixing WPC @ 3% by wt of cement surfaces finished even and fair without using extra cement, complete all as specified and directed. |
| 44 | M&L for rendering 5mm thick in CM 1:3 finished even and smooth with out using extra cement in ceiling,complete all as specified and directed. |
| 45 | M&L for preparing new plaster surfaces of ceiling and applyingt three coats of white wash over coat of primer, complete all as specified and directed. |
| 46 | M&L for preparing decorated plastered or unplaster surfaces of walls, wall projection of face of chajja, projected face of roof slab and face and sides of sunshade etc. By brooming down or steel wire brushing, scrapping down smoke soot moulds, moss and effloroscent salr ane treating oil and greese spots and applying one cote of weather proof paint (exterior emulsion paint) in camouflage pattern using mechanical means (Two or more combination design, pattern and colour shall be as approved by GE or as per existing cover new plaster surfaces of walls, complete all as specified and directed. |
| 47 | M&L for preparation of new plaster surfaces of walls and applying two coats of oil bound distemper over one coat of primer including 1 mm thick wall care putty, complete all as specified and directed by Engr-in-Charge. |
| 48 | M&L for complete removing existing treatment of wall & ceiling surface and applying two coats of oil bound distemper overover one coat of primer over 1 mm thick wall care putty, complete all as specified and directed by Engr-in-Charge. |
| 49 | M&L for complete removing of existing treatment and applying two coat of weather proof paint (exterior emulsion paint)incamouflage pattern over one coat wall putty of minimum 1.5mm thickusing mechanical means (Two or more combination design, pattern and colour shall be as approved by GE or as per existing,complete all as specified and directed. |
| 50 | M&L for complete removal of existing treatmentof ceiling surfaces and applying two coat of white wash, complete all as specified and directed. |
| 51 | M&L for complete removing existing treatment of wall surfaces and applying two coats of oil bound distemper overover one coat of primer over 1 mm thick wall care putty, complete all as specified and directed by Engr-in-Charge. |
| 52 | S&F of Providing & fixing false ceiling at all heights with fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG (Glass Fibre W Reinforced Gypsum) false ceiling tiles of pe Size 595 x 595 mm of approved texture, 12 design and patterns having moisture mi content less than 2%, humidity resistance ed- of 99%, NRCO.50 to 0.75 as per IS:8225:1987, Non combustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter- locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200 mm and secondary intermediate cross-T of size 15 X 32 mmn of length 600 mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) te 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L -shape level adjuster of size 85x25x2mm Galvanised iron perimeter wall angle of size 24x 24x 0.40mm of length 3000 mm to be fixed on periphery wall partition with the help of plastic rawl plugs at 450 mm center to Center and 4Omm long dry wall wood screws, The work shall be Carriod out as per specifications, drawing and asper directions of the Engineer-in- Charge including removal of existing false ceiling. |
| 53 | Supply and fixing of Chequered cement concrete colouredtiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors laid over including 1:6 CM 20mm thick sand cushioning including filling of joints with sand, complete all as specified and directed. |
| 54 | S & F for powder coated aluminium sections for doors, windows, ventilators, door partition including fabrication of frame shutters and fixing with necessary lugs, cleats, rollers, handles, locking arrangement etc. including all accessories such as glazings clips, and rubber beadings for fixing glass panes in frame, complete all as specified and directed. Note : (i) Glass panes will be measured & paid separately . (ii)The quoted rate shall be inclusive of cost of rubber beading however it will be not be weighed and not paid separately.(iii) All other minor details including cost of locking arrangement shall be included in the quoted rate.(iv) Windows all around will be sealed with silicon sealant.Make : Hindalco/Indal (Indian Al Coy)/Jindal/Associated Profile & Aluminium Ltd/Ajit India. |
| 55 | S&F in repair for galvanised M S Wire cloth of 0.56 mm nominal dia of wire and average width of aparture 1.18 mm fixed with tinned tack for galvanized wire staple incl fixed in repair, complete all as specified & directed. |
| 56 | M&L for 5.0 mm thick sheet glass tinted colour frostedordinary quality and glazing with oil putty in square exc 0.5 sqm in each pane, complete all as specified & directed. |
| 57 | S & F in 10 mm thick toughened (tinted/plain) vaccum filled glass sound proof in double layer as in window/door, framing doors handle, suitable hinges, rubber beading, floor spring and all necessary fittings complete including dismantling of old glass any type, complete required as per site or directed by Engr-in-Charge all as specified and directed. |
| 58 | S & F of 18-19 mm thick HDHMR board prelaminated one side with decorative choice lamination exterior grade , fixed with screw /hinges with frame wk as in cupboard and kitchen cabinet shutters and all other similar wks completed.Make - Action tesla/grren ply/century ply or eqvt. |
| 59 | S&F of Cast brass handles, each 150mm long, complete all as specified and directed. |
| 60 | S&F ofCast brass handles, each 100mm long, complete all as specified and directed. |
| 61 | S & F of Cast brass butt hinges medium weight cold rolled 100 mm long, complete all as specified and directed. |
| 62 | S & F of Cast brass butt hinges medium weight cold rolled 75 mm long, complete all as specified and directed. |
| 63 | S & F of Magnet catcher for cupboard, complete all as specified and directed. |
| 64 | S&F in repair Aluminium die cast body Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg, complete all as specified and directed. |
| 65 | Demolition of Mud/mud puska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof), complete all as specified and directed. |
| 66 | M&L for cutting out cracks to v-section in existing roofs or terrace, cleaning grouting with cement and sand slurry 1:3, complete all as specified and directed. |
| 67 | M&L for cutting grooves in brick wall 75mm wide and 65mm deep & shaping horizontal face of groove with cement, complete all as specified and directed. |
| 68 | M&L forPCC 1:3:6 type B-1(using 20mm graded crushed stone aggregate) for providing cement concrete as levelling and roof kerbs or mud stops, including finishing the surface with grinder to receive the acrylic based water proofing material, rounded or chamfered on edges etc, complete all as specified and directed. |
| 69 | M&L for preparation of new surface andapplying a coat of hot blown bitumen of grade 85/25 conforming to IS 702 over primed surface of roof slab @ 1.20 Kg/Sqm, complete all as specified and directed. |
| 70 | M&L for APP basedpolymeric water proofing membrane minimum weight 3.5 Kg/ Sqm and minimum 3mm thick reinforced with polyster non wove fabrick (Weight not less than 150gms/Sqm or as per IS),laid over hot bitumen surface by torched application with the strict supervision of manufacturers technical supervisor. Membrane shall be laid with 100mm side/end lap on prepared surface as per manufacturer instruction work shall be carried out strictly with the technical tradesmen and supervision of technical staff of manufacturer, complete all as specified and directed. |
| 71 | M&L for Rendering or bedding layer15mm thick in cement mortar (1:3) cover concrete surfaces of roof, mixed with linesed oil @ 3% wt of cementinclduing finishing surfaces even and fair without using extra cement inclusive linesed oil, complete all as specified and directed. |
| 72 | M&L for 300mmX300mm, 9-10 mm thick size roof cool ceramic tile to reduce room temperature, slip risistance, white in colour, having properties like water absorption max 3.3%, breaking strength 1000N, moisture expansion maximum 3% scratch hardness 4 minimum, thermal shock reisistance 10 cycles, min impact resistance 0.55 minimum, tiles laid on cement mortar 1:6 and pointing in CM 1:3 over 15 mm screed bed, complete all as specified and directed. |
| 73 | Demolition of brickwork or stone boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed. |
| 74 | M&L for Brick work with sub class \"B\" old size built in CM 1 : 6, straight or curved on plan exc 6m mean radius on plan, complete all as specified and directed. |
| 75 | M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate in surface channel drains, complete all as specified and directed. |
| 76 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds etc., complete all as specified and directed. |
| 77 | M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping including weathening slightly rounded or chamfered angles and throating as directed and including necessary form work required, complete all as specified and directed. |
| 78 | Rending 10mm thick in CM 1:4 on concrete surfaces and finished even and smooth using extra cement complete with wpc (wpc measured and paid seperately), complete all as specified and directed. |
| 79 | M & L for precast RCC 1:2:4 type B1 using 20mm graded stone aggregate incover slabs including necessary form work etc for manholes covers set in CM 1:4 (reinforcement measured seperately), complete all as specified and directed. |
| 80 | S&F of Mild Steel TMT bars 10mm dia cut to length bent to shape required for handles of manhole cover slab, complete all as specified and directed. |
| 81 | Cutting into existing manholes for connecting new drains of 200 mm dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required, complete all as specified and directed. |
| 82 | Supply, install,fixing and commissioningcassete type air conditioner of capacity 1.5 TR,five star rated withinvertor type cordless remote control unit and in built air ioniser, plasma filter for better indoor air quality, star rated suitable for wall mounted, single phase, 230/250 volt AC including breaking necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing finishes after commissioning, making necessary connections unplasticised PVC pipes medium duty 20 mm dia for draining out condensed water all as required including necessary connection, complete all as specified and directed.Note :- (i) Quoted rates deem to be included cost ofdrain pipe, copper tubing and 2.5 sqmm multi standard copper cable (all 3 mtr length) , backet,wall mounted AC Stand, hole in brick wall etc.(ii) Air conditioner shall be of makeCarrier /Daikin / Blue star/ Voltas as approved by GE.(iii)Installation and commissioning to be done through OEM / itsauthorised service centre / dealer. |
| 83 | Supply and fixing of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity5 KVA, complete all as specified and directed. |
| 84 | Supply and fixing ofsubmain wiring with two single core6.0 sq mmPVC insulated FRLSH multistrand copper conductor cable drawing into and including rigid non metallic PVC conduit, medium gradeISI marked with all conduit fittings & fixing accessories and one single core 6.0 Sqmm FRLSH multistrand copper conductor cable as continuous earth wire complete. Note:-The rates for wiringinclude for Cutting chases for conduits and sinking\"s for boxes and making good to walls, floors etc. for concealed conduit wiring, complete all as specified and directed. |
| 85 | Supply and fixing of sheet metal enclosure single pole and neutral enclouser with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, complete all as specified and directed. |
| 86 | Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. |