| 1 | Taking down carefully unserviceable street light fittings of any make and capacity from 9/11 mtr long poles and replaced with new fittings as per BOQ mentioned in schedule at the same/ other location, including rectification of connection wire and underground cable if any fault upto serviceable condition complete all as specified and directed by Engr in charge. Note:- Necessary T & P like ladder / Boom Vehicle, tools etc shall be deemed to be included in the quoted rate. |
| 2 | S&F in replacement of LED street light fitting 90-95 Watt, system efficiency not less than 100-120 lumen / watt, IP66 including 10KV SPD,consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality transmittance lens, epoxy powder coated die cast aluminium housing with weather proof gasket for lamp & driver compartment, heat resistant toughened glass fitted in cast aluminium housing with SS screws,fixed on existing bracket & connecting complete all as specified and as directed.Make:- Evereadycat No LEDSL0915-04-HE/Philips cat No BRP062LED92CWSLCA1S1PSU/Wipro cat No LR02-102-XXX-54-G2 |
| 3 | S&F in replacement of LED street light fitting 60-65 Watt, system efficiency not less than 100-120 lumen / watt, IP66 including 10KV SPD,consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality transmittance lens, epoxy powder coated die cast aluminium housing with weather proof gasket for lamp & driver compartment, heat resistance toughened glass fitted in cast aluminium housing with SS screws,fixed on existing bracket & connecting complete all as specified and as directed.Make:- Eveready cat No LEDSL06015-04HE/Philips cat No BRP062LED 65 CW SLA S1 PSU/Wipro cat No LR02-501-XXX-57-G3 |
| 4 | S&F in replacement of LED street light fitting 120-130 Watt, system efficiency not less than 100-120 lumen / watt, IP66 including 10KV SPD,consisting of high / low voltage cut off, maintenance free isolated electronic driver circuits, low THD, PMMA grade high quality transmittance lens, epoxy powder coated die cast aluminium housing with weather proof gasket for lamp & driver compartment, heat resistance toughened glass fitted in cast aluminium housing with SS screws,fixed on existing bracket & connecting complete all as specified and as directed.Make:- Eveready cat No LEDSL12015-04HE/Philips cat No BRP409LED 130 CW SLC FG PSU GRV2/Wipro cat No LR02-132-XXX-57-G3 |
| 5 | M&L for servicing / overhauling of high mast light assembly of any make model, capacity, height by greasing of wire rope, winch, motor with complete function, proper connection of light fittings in lantern carrage, cleaning ofHigh Mast panelincluding replacement unserviceable high mast fittings complete all as specified and as directed. |
| 6 | S&F in replacement of steel wire rope of high mast light from winch to topmade out of stainless steel grade AISI 316 suitable for taking min 750 kg loadas per existing rope size etc complete all as specified and as directed.Make:- USHA / Ashai / Bw ltd |
| 7 | S&F in replacement of weather proof, PVC insulated, PVC sheathed unarmoured flexiblecable, with multistranded copper conductor of size 4 Sqmm, 3 core, fixed from Junction box to high mast light fittings etc complete all as specified and as directed. |
| 8 | M&L for repairing of 1-1.5 HP capacity electric motorof high mast, AC 3 phase, dismantling the motor cutting and taking out the old winding wires, cleaning the slots, rewinding the motor with appropriate size of super insulated copper conductor winding wire of same gauge, and varnishing complete including replacing the worn out bearing, reassembling the motor fixing in same position and testing complete all as specified and directed by Engr In charge. |
| 9 | S&F in replacement Winch suitable for taking minimum 750 kg loaddouble drum, (Gear Ratio - 50 : 1) motor driven / manual driven, self lubricating etc complete all as specified and as directed. Make:- Ashai / BW ltd / Usha |
| 10 | Supply and fixing / drawPVC insulated and sheathedtrailing cable copper conductor cable of size 2.5 Sqmm 5 core, EPR PCP round cable 1100 volt grade including taking down old unserviceable one etc complete all as specified and as directed by Engineer-in-Charge. |
| 11 | S&Fin replacement double dome LED type aviation obstruction lightprovided on top of high mast. Led lamp 2 nos x 100 watt aviation obstruction light fitted in a weather- proof box on body unit of aluminium alloy including taking down old complete all as specified and as directed by Engr-in-charge. Note:- (i) Connection & erection of the same on high mast pole shall be deemed to be included in quoted rate. (ii) All extra fittings like clamps, nut, bolts, washers required to install the light shall deemed to be included in quoted rate. |
| 12 | S&F in replacement of LED flood light fitting 200 Watt, system efficiency not less than 100-120 lumen / watt, IP66 including 10KV SPD,consisting of high / low voltage cut off, maintenance free isolated electronic driver circuits, low THD, PMMA grade high quality transmittance lens, epoxy powder coated die cast aluminium housing with weather proof gasket for lamp & driver compartment, heat resistance toughened glass fitted in cast aluminium housing with SS screws,fixed on existing high mast & connecting complete all as specified and as directed.Make:- Eveready cat No LEDFL20015-03M/60M/Philips cat No BVP122 LED200 CW FLNB FG PSU A1/Havells cat No JETAVALOURFLS200WLED757MODSYMLTG |
| 13 | S&F in replacement of LED flood light fitting 150 Watt, system efficiency not less than 100-120 lumen / watt, IP66 including 10KV SPD,consisting of high / low voltage cut off, maintenance free isolated electronic driver circuits, low THD, PMMA grade high quality transmittance lens, epoxy powder coated die cast aluminium housing with weather proof gasket for lamp & driver compartment, heat resistance toughened glass fitted in cast aluminium housing with SS screws,fixed on existing high mast & connecting complete all as specified and as directed.Make:- Evereadycat No LEDFL15015-04/60M/Philips cat No BVP183 LED140 CW FG WB 150W PSU/HPL cat No HPLLEDFL15060F |
| 14 | Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles & stay etc complete all as specified and as directed by Engr-in-Charge. |
| 15 | Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid, tested complete all as specified and as directed by Engineer-in-Charge. |
| 16 | Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed by Engr-in-charge |
| 17 | M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm and punned thickness i.e. 18cm shall be measured for paid purpose) complete all as specified and as directed. |
| 18 | M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat complete all as specified and as directed. |
| 19 | M&L for augering of holes in true horizontal position under road /pavement by means of mechanical rig after doing ultrasound technique to prevent any damage to existing cables/pipe lines coming in route 1.5 Mtr deep and not exceeding 15 Mtrs long including laying HDPE/GI pipe upto150mm dia complete all as specified and as directed. |
| 20 | Taking out old unserviceable LT under ground cable any type from trenches, pipes & poles complete all as specified and as directed. |
| 21 | Supply and laying in replacementofXLPELT 1100 Volt grade, armoured underground cable of size 10 sqmm 2 core with stranded aluminium conductorin trenches /passing through pipes/ on poles etc complele all as specified and as directed. Note for srl item No. 21.00 to 27.00:- Excavation, earthwork and protection of cable shall be measured and paid seperately. |
| 22 | All as per srl item No 21 above but 16 Sqmm 2 core complele all as specified and as directed. |
| 23 | All as per srl item No 21 above but 16 Sqmm 4 core complele all as specified and as directed. |
| 24 | All as per srl item No 21 above but 25 Sqmm 4 core complele all as specified and as directed. |
| 25 | All as per srl item No 21 above but 70 Sqmm 3.5 core complele all as specified and as directed. |
| 26 | All as per srl item No 21 above but 120 Sqmm 3.5 core complele all as specified and as directed. |
| 27 | All as per srl item No 21 above but 50 Sqmm 3.5 core complele all as specified and as directed. |
| 28 | Supply & jointing heat shrinkable straight through joint suitable for LT 1100 Volt grade XLPE cable of size 150-70 Sq mm 3.5 core completewithtreating of cable to make ready for jointing complele all as specified and as directed. |
| 29 | Description all as per item No 28 but of size 35 -50 sqmm 3.5 core complele all as specified and as directed. |
| 30 | M&L for defect rectification LT cable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. including and additionalexcavation in normal alluvial strata required forexposing the cable fault, removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of size up to 240 Sq mm 3.5 core complele all as specified and as directed. Note:- The fault locating equipments shall be brought to site within the hours of instruction received from Engr-in-Charge. |
| 31 | S&F in replacement of GI tubing 50 mm bore, light grade laid in tenches for cable protection, under the road/path/along the polecomplete all as specified and as directed. |
| 32 | S&F in replacement of GI tubing 80 mm bore, light grade laid in tenches for cable protection, under the road/path/along the polecomplete all as specified and as directed. |
| 33 | M&L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundation/post holecomplete all as specified and as directed. |
| 34 | M&L for PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) formaking coping of LTpoles complete all as specified and as directed by Engr-in-Charge . |
| 35 | M&L for Junction box outdoor in replacement, 3 phase 415 Volts of size (350x250x150) mm made out of hot press moulded SMCfront openable hinged type including 4 Nos. Aluminium bus bars mounted on insulators heavy duty of rating 32 Amps with necessary fixing arrangements to pole with MS calmps, nuts, bolts etc of size (25 x 4) mm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. Make : Sintex/Hensel/L&T |
| 36 | S&F in replacement of analog type time switch 3P module, DIN 24 hours programmable every 30 minutes of current capacity 32 Amps with one change over including connecting to existing power contactor complete as specified and as directed. |
| 37 | M&L for scraping old paint from fire stand i.e. hut shape of size (1.2x1.2) mtr including GI pipe 32mm dia by using wire brush complete and applying two coats of synthetic enamel paint (Red colour) before applying a coat of primer and wirtten in white paint in english and hindi \"FIRE\" complete all as specified and as directed by Engr in charge. |
| 38 | S&F in replacement of fire beater of size 14 inch x 17 inch of red colour made up with MS of suitable gauge as per fire safety norms with 6 feet long bamboo handle complete all as specified and as directed. |
| 39 | S&F in replacement of fire bucket of capacity 10 Ltr of red colour made up with MS of suitable gauge as per fire safety norms with written by white colour \"FIRE\" on body complete all as specified and as directed. |
| 40 | S&F in replacement of fire hook made up with hardened carbon steel (Red colour) as per fire safety norms with 10 feet long bamboo handle red colour complete all as specified and as directed. |
| 41 | S&F 9 Kg ABC type fire extinguisher for electrical equipment (IS 15683:2006) and ISI marked duly filled by extingushing chemical agent alongwith hook for fixing complete all as specified and as directed by Engr In charge. |
| 42 | Supply and fixing in replacement of street light fitting bracket fabricated of 40 mm GI tubing duly bent to shape, 1.5 mtr long complete alongwithtwo Nos MS clamps (40x5) mm and nut, bolts & washers complete all as specified and as dircted by Engr-in-Charge. |
| 43 | Material and labour in replacement ofthree core 2.5 sqmm copper conductor cable for connecting up street/ secuirity light with pole junction box complete all as specified and as dircted. |
| 44 | Supply and fixing in replacement ofMCCB 63 A, 4 pole16 kA necessaryconectionincluding taking out old existing unserviceable MCCB from panels etc complete all as specified and as directed. Make:- Havells/HPL/L&T |
| 45 | S&F in replacement MCCB 400 Amps 4 pole 50 kA 415 Volts 50 Hz with thermaladjustable magnetic settings, Icu=Ics, necessaryconectionincluding taking out old existing unserviceable MCCB from panels etc complete all as specified and as directed. Make: Havells/HPL/L&T |
| 46 | S&F in replacement MCCB 160 Amps 4 pole 16 kA 415 Volts 50 Hz with thermaladjustable magnetic settings, Icu=Ics, necessaryconectionincluding taking out old existing unserviceable MCCB from panels etc complete all as specified and as directed. Make:- Havells/HPL/L&T |
| 47 | S&F in replacement MCCB 125 Amps 3 pole 16 kA 415 Volts 50 Hz with thermaladjustable magnetic settings, Icu=Ics, necessaryconectionincluding taking out old existing unserviceable MCCB from panels etc complete all as specified and as directed. Make:- Havells/HPL/L&T |
| 48 | S&F in replacement LED bollard of capacity 10/11 watt, IP 65/66 for garden/pathway made with aluminium extrusion for studdiness with polycarbonate diffuser complete all as specified and as directed. Make:- Eveready cat No LEDBLB01015-01/Crompton cat No LBLA1-10-CDL/Wipro cat No LB14 131 XXX6505 |
| 49 | S&F in replacement of indirect decorative LED post top lantern 40/45 Watt, IP65 with die cast aluminium spigot, powder coated aluminiumreflector complete all as specified and as directed. Make:- Crompton cat No LPTOI45CDL/Halonix cat No HLPT-02-40CW IND/Bajaj cat No BRIL45WLEDNW |
| 50 | Supply and fixing in replacement ofPower contactor 32-40 Amp, 4 pole for timer panel complete all as specified and as directed. Make : HPL/ L&T/ Havells |