Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Schedule \"A\" Part – I to Schedule \"A\" Part – XXI:NOTE: Schedule \"A\" Part – I to Part – XIX are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only |
| 2 | Lumpsum price worked out by the contractor for \"Buildings & Structures\",as listed in Schedule \"A\" Part – I . |
| 3 | Lumpsum price worked out by the contractor for \"Site Clearance / Earthwork/ Excavation/ Area development\", as listed in Schedule \"A\" Part – II . |
| 4 | Lumpsum price worked out by the contractor for \"Internal Electrification\", as listed in Schedule \"A\" Part – III . |
| 5 | Lumpsum price worked out by the contractor for \"Internal Water Supply\", as listed in Schedule \"A\" Part – IV . |
| 6 | Lumpsum price worked out by the contractor for \"Sewage Disposal \",as listed in Schedule \"A\" Part – V . |
| 7 | Lumpsum price worked out by the contractor for \"External Water Supply\", as listed in Schedule \"A\" Part – VI |
| 8 | Lumpsum price worked out by the contractor for \"External Electrification\",as listed in Schedule \"A\" Part – VII |
| 9 | Lumpsum price worked out by the contractor for Roads/Culvert/concrete pad\", as listed in Schedule \"A\" Part – VIII . |
| 10 | Lumpsum price worked out by the contractor for \"Area drainage\", as listed in Schedule \"A\" Part – IX |
| 11 | Lumpsum price worked out by the contractor for \"Retaining Wall/ Fencing/ Gate\",as listed in Schedule \"A\" Part – X |
| 12 | Lumpsum price worked out by the contractor for \"Fire fighting and fire alarm system\", as listed in Schedule \"A\" Part – XI |
| 13 | Lumpsum price worked out by the contractor for \"Lightning Protection\", as listed in Schedule \"A\" Part – XII |
| 14 | Lumpsum price worked out by the contractor for \"Lift\", as listed in Schedule \"A\" Part – XIII |
| 15 | Lumpsum price worked out by the contractor for \"Crane\", as listed in Schedule \"A\" Part – XIV |
| 16 | Lumpsum price worked out by the contractor for \"AC Plant\", as listed in Schedule \"A\" Part – XV |
| 17 | Lumpsum price worked out by the contractor for \"Summer appliances\",as listed in Schedule \"A\" Part – XVI . |
| 18 | Lumpsum price worked out by the contractor for \"Demolition\", as listed in Schedule \"A\" Part – XVII |
| 19 | Lumpsum price worked out by the contractor for \"DG Set\", as listed in Schedule \"A\" Part – XVIII |
| 20 | Lumpsum price worked out by the contractor for \"OBSRTUCTION LIGHT\", as listed in Schedule \"A\" Part – XIX |
| 21 | Lumpsum price worked out by the contractor for \"Special power supply\", as listed in Schedule \"A\" Part – XX |
| 22 | Lumpsum price worked out by the contractor for \"Dispersal\", as listed in Schedule \"A\" Part – XXI |
| 23 | Schedule \"A\" Part - XXII [Miscellaneous Items] |
| 24 | Internal Electrification |
| 25 | Point Wiring complete with 1100 Volts, FRLSH Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc concealed in walls, including 1100 Volts, FRLSH Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified. |
| 26 | All as per Serial Item No. 22 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified. |
| 27 | All as per Serial Item No. 22 above but One 3 Pin Switch Socket Outlet 5 Amps on same Board complete all as specified. |
| 28 | All as per item No.22 here-in-before but controlled by two two way switch complete all as specefied and directed. |
| 29 | All as per Serial Item No. 22 above but one 3 Pin Switch Socket Outlet 16 Amps on independent board, with 1100 Volts, FRLSH grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLSH grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor. |
| 30 | Supply and fixing of ceiling fan complete with blades, down rod and other accessories, AC 230 Volts, 1200 mm sweep, min air delivary 210 CFM with service value 6.00, BEE, 5 star rated with brushless direct current motor [BLDC] including connecting with 1.0 Sqmm, 2 core copper conductor from ceiling rose complete all as specified and as directed. |
| 31 | Supply and fixing exhaust fan, 250mm sweep, plastic body, heavy duty with louvers, AC single phase, 230 volts, connection with 1.0 sqmm copper conductor flexible wire from ceiling rose including making necessary opening and making good the disturbed surface complete all as specified and as directed. |
| 32 | Supply and fixing exhaust fan, 300 mm sweep, metallic body, heavy duty , AC single phase, 230 volts , 5 star rating, connection with 1.0 sqmm copper conductor flexible wire from ceiling rose including making necessary opening and making good the disturbed surface complete all as specified and as directed. |
| 33 | S&F energy efficient LED Tube light fitting with tube 5W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets including connecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed |
| 34 | S&F energy efficient LED Tube light fitting with tube 10W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets includingconnecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed |
| 35 | S&F energy efficient LED Tube light fitting with tube 18/20W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets includingconnecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed |
| 36 | S & F energy efficient LED security light fitting with tube 30 watts new generatiionenergy saving & environmental friendly long life, made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre-wired and connecting up with with 1.0 Sqmm copper conductor cable upto connector including 1.5 metre long GI tubing light grade bracket of 32 mm dia bend to shape for fixing on wall/ polewith suitable MS bracket nuts, bolts etc., complete all as specified and directed. |
| 37 | M & Lforsub-main wiring with 4.0 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 4.0 sqmmPVC insulated unshethed multi-stranded copper conductorcable for earth wiredrawn through 20 mm dia PVCconduit complete all as specified and as directed.Note :(i) Two run of 4.0 Sqmm + one run of 4.0 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. |
| 38 | Supply and fix polycarbonate meter box as per IS 14772 with IP -55 weather proof and temperature proof,fire retardant suitable for three phase smart pre-paid meter viewing glass, concealed hinge and earth bolt plugged including cable glands for incoming and outgoing cables and locking arrangement for top cover of the box without affecting communication complete all as specified and directed. |
| 39 | M & Lforsub-main wiring with 10.0 sqmm nominal area four single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 10.0 sqmmPVC insulated unshethed multi-stranded copper conductorcable for earth wiredrawn through PVCconduit of suitable size complete all as specified and as directed.Note :(i) Four run of 10.0 Sqmm + one run of 10.0 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. |
| 40 | S & F MCCB DB, vertical double door, TPN, 4 way, sheet steel, with 200 Amps rated bus bar, 415 Volts, 50 Hz, IP : 43 protection,concealed in walls, including provision of MCCB FP 40 Amps, 10 KA as incommer and outgoing circuits, filling the empty with blanks, making good the disturbed area as per existing surfacecomplete all as specified and as directed. |
| 41 | S & F MCB DB, vertical double door, TPN, 6 way, sheet steel, , 415 Volts, 50 Hz, IP : 43 protection,concealed in walls, including provision for fixing RCBO, FP as incommer and outgoing circuits, MCB SP/TP filling the empty with blanks, making good the disturbed area as per existing surfacecomplete all as specified and as directed. |
| 42 | Supply and fixing wall mounted fan, 450mm sweep,AC single phase, 230 volts, connection with 1.0 sqmm copper conductor flexible wire from ceiling rose, 5 star rating complete all as specified and as directed. |
| 43 | Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part - I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified. |
| 44 | Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part - I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed. |
| 45 | Internal Water Supply |
| 46 | S & F 15 mm dia Bib taps, long body, fancy type, chromium plated screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 47 | S & F 15 mm dia Bib taps, long body, fancy type, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 48 | S & F CP mixer for mixing hot and cold water fancy type, chromium plated,screwed down for pipe, with two outlets going (one for bib tap and other for shower) complete all as specified and as directed. |
| 49 | S & F 15 mm dia bib tap two way, fancy type screwed down and fixed suitable for 16 mm outer dia CPVC pipe complete all as specified and as directed.Note: The maximum flow rate will be 03 LPM |
| 50 | S & F 15 mm health faucet, chromium plated, fancy type with steel flexible complete suitable for 16 mm outer dia CPVC pipe complete all as specified and as directed. |
| 51 | S & F CP mixer swan neck for mixing hot and cold water fancy type, chromium plated,fancy type screwed down for pipe, with two outlets going (one for hot and one for cold) kitchen complete all as specified and as directed. |
| 52 | External Electrification |
| 53 | Supply, Install, testing and commissioning of new 11 KV, 630 Amps Outdoor type load break switch (LBS) complete unit, extensible 1 way load break switch stand alone floor mounted, internal copper bus bars not less than 3.15 mm thick having MS Sheet Steel enclosure suitable for IP55 as per IEC 62271-200, LBS should complete with all accessoriessuch as HRC fuse 11 KV- 3 NosManual Trip Push Button, terminal boots, Provision for receiving incoming/outgoing Cables through Bottom entry, including termination kit & glands, cable supports, all front cable terminations, mechanical indications for load break switch ON/OFF, Heater ON / OFF switch with filament type 200Watts space heater & thermostat, single phase switch with socket, Lamp for panel illumination with snap type door limit switch.Surge Arrester (9kV,10kA) including Control Wiring with appropriate size complete all as specified and directed with the following specifications as given :-Note : -(i)Factory inspection of load break switch and its testing shall be done by the representative of the Accepting Officer.(ii) The contractor shall produce drawing of load break switch (LBS) for according approval of GE before the ordering of material to manufacturers. |
| 54 | Supply, install, test and commisioning of 11KV, 630A, 21KA, 3sec motor operated, compact gas insulated for outdoor application with IP-67 class of protection with SS 304 grade tank, impulse withstand voltage of 75 kV, insulation level of 28 kV (@power frequency of 1 min), control voltage 24V DC for motor operation, fully rated with earth switch, spring assisted mechanism, Arc proof type cable cover interlocked with Earth Switch, Red/Green Push button for On/Off Operation, capacitive voltage indication fixed type with aux contact, The VCB of RMU must have duty class of E2, M2 & C2 with 10000 mechanical operations(Type test report required at the time of drawing submission). Make of VCB and VI should be of same make for better optmization, suitable rating CTs and boots suitable for bottom entry front/ side / rear termination of 3 core cable 120-240 Sqmm, both side extendible non- draw out type Ring Main Unit having interlocking facility & internal arc tested with 21kA for 1s in cable & tank compartment (type test reports required along with drawing) with following details.(04 Module HT Switchgear RMU 4 way(having 02 LBS & 02VCBs) from OEM factory only. |
| 55 | (a) Incoming : (i) Incomer No.1:- 01 No., 630 Amp motorized Load break switch triple pole, single break 3 position as incomer (On, Off and earth having STC capacity 21KA for 3 seconds with copper bus bar and copper earth bar as per IEC 61958-1, earth fault indicator.(ii) Incomer No.2:- 01 No., 630 Amp motorized Load break switch triple pole, single break 3 position as incomer (On, Off and earth having STC capacity 21KA for 3 seconds with copper bus bar and copper earth bar as per IEC 61958-1, earth fault indicator.(b) Outgoing: (i)Outgoing No. 1:- 02 Nos., 630 Amp motorized Vaccum circuit breaker triple pole, single break 3 position with duty class of E2, M2, C2 with 10000 mechanical operations as outgoing (On, Off and earth having STC capacity 21KA for 3 seconds with copper bus bar and copper earth bar as per IEC 61958-1, cable bushings, shunt trip control, busbar cover, ring core current transformer of ratio 50/1 A.Note 1 -Foundation work as per OEM\"s recommendation is deemed to be included in the quoted rates for installation of RMU.Note 2 -Units shall be SCADA compatible. Note 3 - Drawing to be submitted for approval to GE before procurement of Item. |
| 56 | Supply, Install, Testing and commissoning triple redundant panel board (Indoor Type) suitable size, having provisions of 01 incomer for normal EB supply from 750 KVA transformer and from 2 x 625 KVA DG set CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 2mm thick CRCA steel sheet, weather / dust/ vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, panel to be mounted on cable trench if required with base channels as required complete in all respect all as specified & directed by Engineer-in-charge including comprising of following items :-(a) Motorised changeover switch, 4 Pole, 1250 Amps - 1 No(b) ACB 4 pole EDO 1250 Amps - 2 Nos(c) ACB 4 pole EDO 1000 Amps - 2 Nos(d) Battery charger - 2 Nos(e) AMF relay - 1 No(f) Aux Contactor - 2 Nos(g) Timer - 3 Nos(h) VMR - 3 Nos(j) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (k) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three |
| 57 | Supply, fix ,connecting , testing and commissioning of OEM Manufactured APFC Panel (automatic and manual operation) with 7% Aluminium reactor of capacity 150 KVAR (Output) @ 440 V AC interconnection with LT Panel/ Transformer (outdoor/ indoor) with appropriate size of electric power cable 1.1KV . The stage rating shall be (3x25, 2x15, 3x12.5,1x5,1x3) KVAR [6 steps]. The APFC Panel shall be fully type tested at an independnt Laboratory and shall comply with IEC 61439-1&2 and IEC 61921, IS-16636-2017. The degree of protection of enclosure system of the APFC Panel shall be min IP 54 (Outdoor) in accordance with IEC 60529. The capacitor bank shall be internet of things (IoT) enabled and communicable / integrable with BMS . The APFC Panel shall be Outdoor type confirming to IS 13341:1992 & IS13440:1993 floor mounted design fabricated out of 14 SWG CRCA Sheet treated through chemical with 8 tank process method of degreasing, derusting and phosphating powder coating (60-80 microns), painted in SIEMENS GREY (RAL 7032) shade powder coating paint, weather, dust and vermin proof suitable for humidity upto 95% and having four Nos iron legs made of 50x50x6mm thick, 60cm long angle iron below frame with front door and side/ back opening having locking arrangement prewired with copper conductor PVC insulated wire size 2.5sqmm/ extension strips and connected with suitable size thimbles & lugs. The legs duly embedded in ground (45cm) in PCC 1:3:6 type C1 (using 20mm aggregate). Cable entry from bottom. Transparent Acrylic sheet/Bakelite sheet will be provided for shrouding. Average daily temperature :+35 degree celcius max, Ambient temperature :-5 degree celcius to 40 degree celcius, Maximum altitude 2000m. Approved Make of Panel:-ABB/SCHNEIDER/SIEMENS/L&T/CMKL . The OEM \"s specified cannot authorize any other partners / sub vendors to manufacture APFC Panels on their behalf . |
| 58 | Supply, Install, Testing and commissioning LT distribution board (Indoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 2mm thick CRCA steel sheet, weather / dust/ vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, panel to be mounted on cable trench if required with base channels as required complete in all respect all as specified & directed by Engineer-in-charge including comprising of following item |
| 59 | (a) 4 Nos Aluminium Busbars of high conductivity, 3 Nos for phase (R,Y,B) rating 2400 Amps and 1No for neutral rating 1200 Amp, Mounted on DMC support with heat shrink sleeve - 1 Set.(a) ACB 4 Pole 1200 Amps 50 KA - 1 Nos (Incomer)(c) MCCB 4P 630 Amps, 36 KA, 415 V, 50 Hz - 2 Nos (Out going)(d) MCCB 4P 400 Amps, 36 KVA, 415V, 50 Hz - 1 No (Outgoing for APFC Panel)(e) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (f) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three |
| 60 | Supply, Install, Testing and commissioning LT distribution board (Indoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 2mm thick CRCA steel sheet, weather / dust/ vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, panel to be mounted on cable trench if required with base channels as required complete in all respect all as specified & directed by Engineer-in-charge including comprising of following items |
| 61 | (a) 4 Nos Aluminium Busbars of high conductivity, 3 Nos for phase (R,Y,B) rating 1200 Amps and 1No for neutral rating 800 Amp, Mounted on DMC support with heat shrink sleeve - 1 Set.(b)MCCB 4P 630 Amps, 36 KA, 415 V, 50 Hz - 1 No (Incomer)(c)MCCB 3P 315 Amps, 25 KA, 415 V, 50 Hz - 1 No (Out going)(d) MCCB 3P 160 Amps, 25 KA, 415 V, 50 Hz - 2 Nos (Outgoing)(e) MCCB 3P 100 Amps, 25 KA, 415 V, 50 Hz - 2 Nos (Outgoings) (f) MCCB 3P 63 Amps, 16 KA, 415V, 50 Hz - 5 Nos (Outgoing)(g) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc(h) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three |
| 62 | Supply, Install, Testing and commissioning LT distribution board (Indoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 2mm thick CRCA steel sheet, weather / dust/ vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, panel to be mounted on cable trench if required with base channels as required complete in all respect all as specified & directed by Engineer-in-charge including comprising of following items |
| 63 | (a) 4 Nos Aluminium Busbars of high conductivity, 3 Nos for phase (R,Y,B) rating 800 Amps and 1No for neutral rating 400 Amp, Mounted on DMC support with heat shrink sleeve - 1 Set.(b)MCCB 4P 315 Amps, 36 KA, 415 V, 50 Hz - 1 No (Incomer)(c) MCCB 3P 100 Amps, 25 KA, 415 V, 50 Hz - 3 Nos (Outgoing) (d) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (h) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three |
| 64 | Supply, Install, Testing and commissioning LT distribution board (Indoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 2mm thick CRCA steel sheet, weather / dust/ vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, panel to be mounted on cable trench if required with base channels as required complete in all respect all as specified & directed by Engineer-in-charge including comprising of following items |
| 65 | (a) 4 Nos Aluminium Busbars of high conductivity, 3 Nos for phase (R,Y,B) rating 2000 Amps and 1No for neutral rating 100 Amp, Mounted on DMC support with heat shrink sleeve - 1 Set.(b)MCCB 4P 100 Amps, 36 KA, 415 V, 50 Hz - 1 No (Incomer)(c) MCCB 3P 63 Amps, 25 KA, 415 V, 50 Hz - 1 No (Outgoing) (d) MCCB 3P 32 Amps, 25 KA, 415 V, 50 Hz - 1 No (Outgoing) (e) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (f) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three |
| 66 | Supply, Install, Testing and commissioning LT distribution board (Indoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 2mm thick CRCA steel sheet, weather / dust/ vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, panel to be mounted on cable trench if required with base channels as required complete in all respect all as specified & directed by Engineer-in-charge including comprising of following items |
| 67 | (a) 4 Nos Aluminium Busbars of high conductivity, 3 Nos for phase (R,Y,B) rating 2400 Amps and 1No for neutral rating 1200 Amp, Mounted on DMC support with heat shrink sleeve - 1 Set.(b)ACB 4P 1200 Amps, 50 KA, 415 V, 50 Hz - 1 No (Incomer)(c) ACB 3P 1000 Amps, 50 KA, 415 V, 50 Hz - 1 No (Outgoing)(d) MCCB 3P 315 Amps, 50 KA, 415 V, 50 Hz - 2 Nos (Outgoing) (e) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (f) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three |
| 68 | Supply, Install, Testing and commissioning LT distribution board (Indoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 2mm thick CRCA steel sheet, weather / dust/ vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, panel to be mounted on cable trench if required with base channels as required complete in all respect all as specified & directed by Engineer-in-charge including comprising of following items |
| 69 | (a) 4 Nos Aluminium Busbars of high conductivity, 3 Nos for phase (R,Y,B) rating 3200 Amps and 1No for neutral rating 1600 Amp, Mounted on DMC support with heat shrink sleeve - 1 Set.(b)ACB 4P 1600 Amps, 50 KA, 415 V, 50 Hz - 1 No (Incomer)(c) ACB 3P 1200 Amps, 50 KA, 415 V, 50 Hz - 1 No (Outgoing) (d) MCCB 3P 200 Amps, 36 KA, 415 V, 50 Hz - 1 No (Outgoing) (e) MCCB 3P 100 Amps, 36 KA, 415 V, 50 Hz - 1 No (Outgoing) (f) MCCB 4P 400 Amps, 50 KA, 415V, 50 Hz - 1 No (Outgoing for APFC Panel)(g) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (h) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three |
| 70 | Supply, Install, Testing and commissioning LT distribution board (Indoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 2mm thick CRCA steel sheet, weather / dust/ vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, panel to be mounted on cable trench if required with base channels as required complete in all respect all as specified & directed by Engineer-in-charge including comprising of following items |
| 71 | (a) 4 Nos Aluminium Busbars of high conductivity, 3 Nos for phase (R,Y,B) rating 2000 Amps and 1No for neutral rating 1000 Amp, Mounted on DMC support with heat shrink sleeve - 1 Set.(b) ACB 3P 1000 Amps, 50 KA, 415 V, 50 Hz - 1 No (Outgoing) (c) MCCB 4P 160 Amps, 36 KA, 415 V, 50 Hz - 1 No (Outgoing) (d) MCCB 4P 100 Amps, 25 KA, 415 V, 50 Hz - 2 Nos (Outgoing) (e) MCCB 4P 63 Amps, 25 KA, 415 V, 50 Hz - 2 Nos (Outgoing) (f) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (g) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three |
| 72 | Supply, Install, Testing and commissioning LT distribution board (Indoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 2mm thick CRCA steel sheet, weather / dust/ vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, panel to be mounted on cable trench if required with base channels as required complete in all respect all as specified & directed by Engineer-in-charge including comprising of following items |
| 73 | (a) 4 Nos Aluminium Busbars of high conductivity, 3 Nos for phase (R,Y,B) rating 800 Amps and 1No for neutral rating 400 Amp, Mounted on DMC support with heat shrink sleeve - 1 Set.(b) MCCB 4P 315 Amps, 36 KA, 415 V, 50 Hz - 1 Nos (Incoming) (c) MCCB 3P 125 Amps, 25 KA, 415 V, 50 Hz - 1 No (Outgoing) (d) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (e) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three |
| 74 | Supply, Install, Testing and commissioning LT distribution board (Indoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 2mm thick CRCA steel sheet, weather / dust/ vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, panel to be mounted on cable trench if required with base channels as required complete in all respect all as specified & directed by Engineer-in-charge including comprising of following items |
| 75 | (a) 4 Nos Aluminium Busbars of high conductivity, 3 Nos for phase (R,Y,B) rating 800 Amps and 1No for neutral rating 400 Amp, Mounted on DMC support with heat shrink sleeve - 1 Set.(b) MCCB 4P 315 Amps, 36 KA, 415 V, 50 Hz - 1 Nos (Incoming) (c) MCCB 3P 160 Amps, 25 KA, 415 V, 50 Hz - 1 No (Outgoing)(d) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (e) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three |
| 76 | Supply, Install, Testing and commissioning LT distribution board (Indoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 2mm thick CRCA steel sheet, weather / dust/ vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, panel to be mounted on cable trench if required with base channels as required complete in all respect all as specified & directed by Engineer-in-charge including comprising of following items |
| 77 | (a) 4 Nos Aluminium Busbars of high conductivity, 3 Nos for phase (R,Y,B) rating 400 Amps and 1No for neutral rating 200 Amp, Mounted on DMC support with heat shrink sleeve - 1 Set.(b) Onload changeover switch 4P 200 Amps - 1 No(b) MCCB 4P 200 Amps, 36 KA, 415 V, 50 Hz - 1 Nos (Incoming) (c) MCCB 3P 100 Amps, 25 KA, 415 V, 50 Hz - 2 Nos (Outgoing) (d) MCCB 3P 63 Amps, 25 KA, 415 V, 50 Hz - 1 No (Outgoing) (e) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (e) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three |
| 78 | Supply, Install, Testing and commissioning LT distribution board (Indoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 2mm thick CRCA steel sheet, weather / dust/ vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, panel to be mounted on cable trench if required with base channels as required complete in all respect all as specified & directed by Engineer-in-charge including comprising of following items |
| 79 | (a) 4 Nos Aluminium Busbars of high conductivity, 3 Nos for phase (R,Y,B) rating 200 Amps and 1No for neutral rating 100 Amp, Mounted on DMC support with heat shrink sleeve - 1 Set.(b) MCCB 4P 160 Amps, 25 KA, 415 V, 50 Hz - 1 Nos (Incoming)(c) MCCB 3P 63 Amps, 16 KA, 415 V, 50 Hz - 3 Nos (Outgoing) (c) MCCB 3P 32 Amps, 16 KA, 415 V, 50 Hz - 3 Nos (Outgoing) (d) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (e) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three |
| 80 | Supply, Install, Testing and commissioning LT distribution board (Indoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 2mm thick CRCA steel sheet, weather / dust/ vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, panel to be mounted on cable trench if required with base channels as required complete in all respect all as specified & directed by Engineer-in-charge including comprising of following items |
| 81 | (a) 4 Nos Aluminium Busbars of high conductivity, 3 Nos for phase (R,Y,B) rating 200 Amps and 1No for neutral rating 100 Amp, Mounted on DMC support with heat shrink sleeve - 1 Set.(b) MCCB 4P 100 Amps, 25 KA, 415 V, 50 Hz - 1 Nos (Incoming) (c) MCCB 3P 32 Amps, 16 KA, 415 V, 50 Hz - 4 Nos + 1 spare (Outgoing) (d) Timer switch 415 volts,three phase of 20 Amp rating with power contactor fitted inside the panel - 4 Nos (3 Nos for streetlights and 01 No for flood lights) (e) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc (f) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three |
| 82 | Supply , Fixingand Testing Powder coated Outdoor street light control box of size not less than 280 x 200 x 100 mm Syntax PVC IP 65 ,in and including suitable terminal TPN SMC Connectorfor three phaseCable Line ( IN & OUT) , MCB 6Amps SP\"B\" Series , canopyweather proof hinged doors, incl locking system and arrangements for fixing on Steel Poles with GI/Aluminium clampsas per site requirement complete all as specified and directed. |
| 83 | Supply and fix LED airport taxi link light complete with base plate, flange coupling and connector kit complete all as specified and as directed. |
| 84 | Material and labour for cutting of bituminous road / floor for laying ofU/G cables not exceeding 1.5 meter wide and not exceeding 1.5meterdeep including refilling / with material and, watering well ramming / compacting and making good with PCC 1:3:6, type M-10 100mm thick complete all as specified anddirected.Note :-PCCshall bemeasuredseparately. |
| 85 | Supply and laying Highly Electrical resistant Elastomers electrical mat of size 1mtr x 2 mtr, Confirming IS: 15652/2006 (Latest), ISI marked. High Die Electric Strength Up to 65 KV. Insulation Resistance Up to 1494000 Mega Ohm. Fire Retardant. Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic. No Adverse Effect of Acids, Alkalis and Transformer Oil. Manufactured Without Any Metallic Derivatives Suitable For Both A.C D.C Electrical Installations Easy To Install, Can Be Pasted. Water And Moisture Proof, Does Not Decay.Temp resistance -10 to 55 degree Celcius used in High voltage panels/sub stations/near bus bars/transformer rooms etc |
| 86 | RETAINING WALL/ FENCING/ GATE |
| 87 | Supply and fix in repairs 900 mm dia razor blade galvanised barbed concertina coil having minimum weight of 8 kg(+) or(-) 5% per coil of 2.6mm dia wire streched to a length of 5 to 6m as in fencing to steel posts and to another coil/ MS nibs including fixing with special galvanised fasterners such as J clips, C clips, U clips and steel wire rope for securingcomplete all as specified and as directed by Engr-in-Charge .Note:- After streching the coil, the length of the compound wall on which it has been streched shall be considered for measurement. |
| 88 | fighting and fire alarm system |
| 89 | Supply, installation, Testing & Commissioning of Microprocessor based 2 loop capacity , Networkable analogue addressable type fire alarm control panelcomplying with BSEN 54 with min.600 character LCD display, The panel should be equipped with sufficient numbers of 1 loop with up to 10 to 15% spare capacity with each loop shall have a capacity of minimum 10 detectors and 10 analog addressable devices in one loop. Four access levels, capable of taking Flash Scan devices, flash EPROM sufficient numbers of programmable relay controls for controlling fire hydrant pump, 240 volts AC power supply, automatic battery charger including 24 volts sealed lead acid batteries suitable for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required. and panels shall have provision of integraton with BMS System all as specified and directed. |
| 90 | Supply, installation, Testing & Commissioning of LANDLINE FIRE ALARM AUTO DIALER WITH sms and Memory Available To Store 10 Phone Numbers dialling facility to get the intimation about the location of the area Built in Emergency Speech Dialer with 8 Numbers & 1/ 2 Messages,NO/NC contacts for both fire and fault, Automatic changeover arrangement to standby supply with battery charger with low battery indication,Fault/ failure indication such as MAINS FAIL, short, open, Battery FAIL etc,Micro-Controller Based System,Both Dialling Modes Can Be Used (Pulse/Tone),Recorded Message Playback Speaker Provision Available all as specified and directed. |
| 91 | Supply, installation, Testing & Commissioning of Analog addressable Multi Criteria (Optical/smoke +therma/heat) detectors Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 alongwith mounting accessories and connected items all as specified and directed. |
| 92 | Supply, Installation, testing and commissioning addressable Manual call point (Pull down/Break Glass Type). The device shall have an LED which shall blink in normal state and get steady on activationto monitor the health status of the device and shall be underwritters laboratories listed, semi flush typealongwith mounting accessories and connected items all as specified and directed. |
| 93 | Supply, installation, Testing & Commissioning of Strobe Lights Cum Hooter single stage continous normal operation with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of +5 DB 1000 mtrs range with 110 cd alongwith mounting accessories and connected items all as specified and directed. |
| 94 | Supply,installation, Testing & Commissioning of fault isolator module with automatic resetting arrangement alongwith mounting accessories and connected items all as specified and directed. |
| 95 | Supply, installation, Testing & Commissioning of Addressable control modules for Access control Integration for Hooters / Sounders / Strobes and connected items all as specified and directed. |
| 96 | Supply, installation, Testing & Commissioning of Input module and connected items all as specified and directed. |
| 97 | M&L for sub main wiring/point wiring with 2 runs of 1.5 sqmm PVC insulated stranded copper conductor FRLS cable and 1 run of 1.5 sqmm copper FRLS cable as earth lead in steel conduit laid in duct / along pole/wall etc including making connection complete and making good the distrubed surface matching with existing surface complete all as directed all as specified: |
| 98 | Supply and fix electric motor siren and connected DOL Starter conforming to IS 1941 suitable for three phase 415 V supply with motor not less than 3.7 KW power to be synchronized with existing fire alarm panel including connected items etc. and able to deliver 143 DB noise level with audible range not less than 5000 metres and necessary platform with minimum 30cm above ground level and plan size as recommended by manufacturer alongwith motor cover of MS Sheet 3 mm thick complete all as specified and directed. |
| 99 | Supply and fix 4 way TPN Vertical Double Door DB Box with MCCB incoming IP43 rating complete all as specified and directed |
| 100 | M & L for masonry valve chamber of size 1200 X 1200 X 900 mm [interanl dimensions] comprising of 50mm thick PCC for valve including excavation and earth work in any type of soil and 200 mm thick PCC 1:4:8 type D2 foundation, brick work in CM (1:6) plastring internal surface 15 mm tick in CM (1:4) PCC (1:3:6) type B1 couping 50 x50x6 mm angle iron 3 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer allas specified and as directed. |
| 101 | Supply and lay Ductile Iron Pipe both end flanged, S/S including specials, bends, all fittings etc., Class “K-9”, 150 mm dia complete all as specified and as directed. |
| 102 | M&L for Cutting of Ductile iron pipes of 150 mm borein position for insertion of new tees, branches etc including dewatering due to residual water in pipes complete all as specified and directed. |
| 103 | Supply and fix Fire Extinguisher Dry Chemical Powder (ABC) type 6.5 kg capacity |
| 104 | Supply and fix Fire Extinguisher CO2 type (Light weight squeeze grip type) 4.5 kg capacity |
| 105 | Supply and fix Fire Extinguisher water stored pressure type 9 ltr capacity |
| 106 | Supply and fix Fire Extinguisher Dry Chemical Powder Trolly mounted 25 kg capacity including trolly |
| 107 | Cutting and removing the existing fire hydrant along with existing DI Pipe as schedule and permanently closing the pipeline complete all as specified |
| 108 | LIFTS |
| 109 | Supply, install, test and commissioning of electrically operated Goods lift of capacity 1000 kgs with a speed of approximately 0.5mtr per second to serve ground floor to two floor with a total of 03 floors with AC variable voltage and variable frequency (V3F) drive system on the mocro processor controlled complete with power driven automatic sliding door (COPD) suitable to the size of car having stainless steel panels in hairline finish No. 04 , SS sliding door, PVC flooring in cabin, SS Hair line finish No. 04 ceiling, door operation automatic, entrance protection 3D full height infra red curtain door detector system, indicators (landing/car) with DOT Matrix type direction and position indicators with stainless steel face plates (for car full length COP to be provided), press and speak tree way intercom with speaker, SS Hand Rails in mirror finish, hall lantern (up/down) and Gong indicator arrangement, Pit ladder and Balustrade, over load warning signal, battery operated alaram bell and emergency light, announcement system with music, stop switch, auto cut off car fan switch, door open and close button, Auto rescue device (ARD), do\"s and dont\"s information and minor building work, scaffolding and necessary steel items for the erection of the elevator all as specified as per standard design of manufacturer.Note:-(i) Approximate dimentions of Lift well size 2500 mm Width X 2025 mm Depth, Car Size 1000 mm Width X 1700 mm Depth.(ii) Including Minor Buiding works and Scaffolding in lift shaft(iii) Liason and Documentation with Electrical Inspectorate. |
| 110 | EOT CRANE |
| 111 | Supply, installation, erecting, commissioning, and testing of double girder electrically operated OH crane, Non flame proof, indoor type, 10 ton capacity with span of 43 meter having lift 7 metre (approx.) and bay length 58 mtrs, AC 400/440 V, 3 phase, 50 Hz , Class-II Medium Duty M-5 as conforming to IS 807/3177 and IS : 3177-1999 with and including the following:(a) Squirrel cage induction motors of suitable capacity for Hoist, cross travel and long travel suitable to work on AC 415 V, 3 phase, 50 Hz.(b) Electro magnetic disc brakes forHoist, cross travel and long travel.(c) Capacity of Hoist motor is 12 HP(d) Catacity of CT Motor is 3 HP and LT Motor Twin Drive is 7.5 HP (2 Nos)(e) Wire rope 6 x 36 made of Fiber or Hemp core material of size 16mm dia having number of falls 4 confirmong to IS:3938 Para 5. Rope drum shall be fabricated out of seamless pipe duly machined and grooved to accomodate full length of rope in one layer. The drum shall be mounted on anti-friction ball / roller bearings.(f) Hook is made of EN 3A material type \"C\" shank confirming to IS:3815(g) Gear box for Hoist, cross travel and long travel enclosed helically pinions are made of EN 24 material confirming to IS:1570, gears are made of EN 19 / EN 24 material and initial filling of lubiration oil with oil splashh) Control panels indoor type, made of 2 mm thick CRCA sheet, coated with powder coated paint consiting V3F drive, MCCBs / MCBs, contactors, measuring meters, relays, CTs, connectors, busbars if required complete. |
| 112 | (j) Complete wiring with flexible PVC insulated multi-stranded 1100 Volt grade copper conductor unarmoured cable of suitable sizes conforming toIS 7098 (Part I) 1988.(k) End stop consisting two side full length platform made of mild steel material with steel buffer.(l) Supplying and fixing pendent push button station at an operating voltage of 110 Volt and IP 65 protection along with radio control remote (m) Supplying and fixing 2 x 250 Watts LED light fitting.(n) PVC Flexible festoon type travelling cable system supported on MS trolley moving on C- Rail for cross travel.(o) DSL system with 100 Amp PVC sheathed GI conductor(p) Complete painting of crane with standard clour code and writing the details of crane like capacity, date of installation, load test details etc.(q) Full length platform shall be provided at the one end for maintenance purpose and two short length platforms shall be provided on the other side.(r) Speeds : Hoist 3.00metre per minute, cross travel 20.00metre per minute and long travel 20.00metre per minute. |
| 113 | S&F sheet metal enclosure suitable for 63 Amps MCCB complete all as specified and as directed |
| 114 | AC Plant |
| 115 | Design, Supply and install, test and commissioning of Air Cooled Variable Refrigerant Flow (VRF) Outdoor units (working and stand by) with all Inverter Scroll Compressor in each individual unit, preferably all compressors of suitable capacity, air cooled copper condenser coils must haveAnticorrosive coatings, condenser fan motor shall be weather proof, brushless DC drive, fan shall have lower vibration, motor shall have minimum 10 steps and air flow resistance with protective grill, suitable for 380-420 Volts, 3 Phase + N, 50Hz, AC supply and shall deliver 100% capacity at 35 Degree Centigrade temperature and shall be suitable for operation in upto 55°C ambient without tripping or failure, Minimum Full load coefficient of performance (COP) must be 4.15 DC Inverter compressor, including Refrigerant R-410A with first charge of refrigerant gas, outdoor to have IP55 sealed box for electrical components with micro channel refrigerant cooling and built in air circulation fan , Enhanced vapour injection technology for increased capacity during very long piping suitable PCC foundations and connecting earthing for ODU from the panel complete all as specified of capacity 16 HP [2x8Hp] .The unit shall be with BMS Compaitable Make: CARRIER / TOSHIBA / MITSUBISHINote: Design details with drawings shall be submitted by the contractor to GE for approval before commencement of work. |
| 116 | All as per Item above but of capacity 20 HP [2x10 HP] |
| 117 | All as per Item above but of capacity 234 HP [6x26 HP+ 3x26 HP] |
| 118 | All as per Item above but of capacity 24 HP [1x16 HP+ 1x8 HP] |
| 119 | Design, supply, install, testing and commissioning Double skin Horizontal type Air Handling Unit (AHU) 50mm Thick PUF insulated panel of outer skin 0.6mm GI Pre plasticized finish, inner skin 0.6 mm thick GI, fan section with DIDW Fans Belt driven suitable for 415+/-10%, 50 cycles, DX coil section with 6 row copper tube cooling coil with aluminium fins, DX coil connecting to VRF outdoor units & 22 Gauge, SS drain tray, filter section with Cleanable Pre-filter with 90% efficiency down to 10 micron (EU4), Internal and External supports, etc., including all necessary accessories as per relevant standard. Coil size shall be selected for maximum face velocity of 2.5m/s, filter shall be sized maximum face velocity of 2m/s. Maximum fan outlet velocity shall be 9.5m/s. AHU shall have a lamp with a switch for the maintenance. Sound level at 1m distance shall be less than 75 dBA including required electrical connections complete all as specified for following capacity including VRV AHU KITS.Make -Edgetech/Luftek /Zeco |
| 120 | Supply and install GSS Louvers with bird screen, adjustable damper for fresh air packages of approx. size 500 x 500 x 150 mm made GI frame and sheets complete fixed at AHU room of seminar hall at first floor T Complex including necessary addition / alteration work involved in the wall complete all as specified and as directed. |
| 121 | Supply, install, test and commissioning of Fire-retardant canvas connection to Indoor units for AHU as per manufacturer\"s instructions complete all as specified and as directed. |
| 122 | Supply, install, test and connect Oppose Blade Volume Control dampers for Air balancing as per manufacturer\"s instructionscomplete all as specified and as directed. |
| 123 | Design, Supply, Install, test and commissioning ofhard drawn copper refrigerant pipes for VRF Indoor and Outdoor units with necessary copper fittings, laid neatly, secured with GI clamps and wall brackets with pipe supports as per technical specifications, at every 1.5 meter interval and at bends including insulation with 19 mm thick class \"O\" nitrile rubber, UV treatment (coating) for exposed refrigerant piping insulation complete all as required at site as per specifications and as directed for following sizes. Make: MEXFLOW/CAMIPRO/TOTAL LINENotes: (i) The pipe sizes shall be selected according to the equipment capacities and manufacture\"s specification.(ii) If required, Soft piping will only be allowed from refnet to the IDUs in case the same is as per OEM recommendations.(iii) Contractor shall submit a detailed schedule of piping both suction and liquid line with detailed shop drawings. (iv) Necessary leak /pressure test shall be carried out before charging of refrigerant gas.(v) All brazing shall be protected against oxidation during soldering / brazing by use of dry nitrogen gas flowing through the tube to remove carbon deposits. |
| 124 | Supply and fix Acoustic lining inside sheet metal ducts with 10mm thick Open Cell nitrile rubber class 1, having density 140 kg/m3 insulation using manufacturers recommended adhesive, tapes etc., and applications. Complete all as specified. Make: KFlex /Arma Flex/A Flex |
| 125 | Suppy and fix Y/T joints suitable for refrigent pipe of any size as per manufacturers recommendations for indoor units complete all as specified and as directed. |
| 126 | Suppy and fix Y/T joints suitable for refrigent pipe of any size as per manufacturers recommendations for Outdoor units complete all as specified and as directed. |
| 127 | Supply, fill and Charge Refrigerant Gas R410a during commissioning in addition to default gas in the compressor including vacuum all as specified. |
| 128 | Summer Appliances |
| 129 | S &F Copper tube with insulation for suction and discharge line combined (same size as the AC installed) for connection between indoor and outdoor unit (beyound 3 mtr) complete all as specified and as directed. |
| 130 | S & F 4 core 4 Sq mm muti stranded copper conductor cable for connection between indoor and outdoor unit (beyound 3 mtr) complete all as specified and as directed. |
| 131 | Supply and fix Refrigerator, electric driven (single phase, 240 Volt, 50 Hz), capacity 256 Litres. BEE 5 star rated complete all as specified and as directed. |
| 132 | Supply & Install Voltage Stabilizer for automatic operation single phase natural air cooled indoor type and designed for input variation between 90 Volts to 300 volts with output voltage stabilized at 230 Volts with accuracy +/- 2.5% and capacity 5 KVA or 15 Ampere complete all as specified and as directed. Make: V Guard VE 500 or equivalent in Microtek/Voltamp/Vinitec |
| 133 | Supply & Install Voltage Stabilizer for automatic operation single phase natural air cooled indoor type and designed for input variation between 90 Volts to 300 volts with output voltage stabilized at 230 Volts with accuracy +/- 2.5% and capacity 4 KVA or 12 Ampere complete all as specified and as directed. Make: V Guard VE 500 or equivalent in Microtek/Voltamp/Vinitec |
| 134 | Supply & Install Voltage Stabilizer for automatic operation single phase natural air cooled indoor type and designed for input variation between 90 Volts to 300 volts with output voltage stabilized at 230 Volts with accuracy +/- 2.5% and capacity 2 KVA or 6 Ampere complete all as specified and as directed. Make: V Guard VE 500 or equivalent in Microtek/Voltamp/Vinitec |
| 135 | Demolition |
| 136 | Taking down MCB distribution board with MCB\"s complete all as specified and directed. |
| 137 | DG Set |
| 138 | Supply, install, testing and commissioningof silent Diesel Engine Generating set including accoustic enclosure as per latest CPCB norms 415 Volts 750KVA, 3 Phase, 0.8 power factor, 50 Hz, 1500 RPM self excited self regulated brushless AC generator including accoustic enclosure suitable for ambient condition and conforming to condition under IS-4722, BS-5514/2613/5000 with AMF Panel and including the followingincluding accoustic enclosure suitable for ambient condition at sea area and conforming to Engine as per IS:10002, ISO-3046, BS-5514 and Alternator as per IS:4774, BS EN 60034-1 with the following accessories including necessary suitable size PCC foundation, GI pipe for laying of cables etc., all as per manufacturers instructions complete all as specified and directedMake: Kirloskar/ Cummins/Ashok Leyland/ Jyoti/ Crompton |
| 139 | (i) The capacity of generator set shall be net after all due de-rating factors as per relevant ISI design.(ii) Rate quoted shall be deemed to be inclusive of cable and terminations form generator to the AMF panel, with necessary holes to wall including making good to disturbed surfaces so as to match with the existing finishes all as specified and directed.(iii) The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test.(A) Alternator: Standard design alternator rated at 750 KVA net output at site after considering de-rating as per site conditions at 0.8 (Lag) power factor AC, 3 Phase, 4 wire, 415 Volts, 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class \"H\" and voltage regulation of +/-1% at rated voltage from no load to full load.The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/-1% tolerance.The alternator will be suitable for tropical climate and shall generally conform to BS-2613/5000/IS-4722. |
| 140 | (i) Insulation class-\"H‘(ii) Temperature rise Class-\"H‘(iii) Excitation: Self Excited(iv) Regulation Performance: The voltage is kept constant with +/-1%, manual voltage adjustment within +/-5%(v) Frequency regulation +/-1%(B) Diesel Engine: Adequate capacity of Diesel engine as approved by the Accepting Officer based on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS-5514 with an overload capacity of 10% for one hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under: |
| 141 | (i) Fly wheel with housing(ii) Cooling System: Moulded radiator with fan & belts(iii) Cooling Water Pump: Centrifugal type belt driven(iv) Exhaust System: Exhaust System complete with exhaust piping of 150mm dia. with MS pipe light grade up to & outside and 1 meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure.Exhaust gas turbo charger type.Exhaust manifoldSilencer: Residual type Bellows(v) Fuel System: Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed/ frequency regulation, Fuel filters, Fuel hoses.(vi) Lub oil System: Lubricating oil filter, Lubricating oil pump(vii) Air Intake System: Air intake Manifold, Air cleaner dry type(viii) Governor: Electronic Governor(ix) Starting System: Electric Self starter with maintenance free battery including battery charging alternator |
| 142 | (x) Batteries: Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and starter gear ring start and stop push button, Ignition key/switch.Handling and Operation: Salient features of accessories shall be as under:Radiator with blower fanCorrosion inhibitor coolantPaper element filters for fuel, lub oil and by passElectronic governor controlled direct fuel injection systemFly wheel housing and fly wheel(xi) Generator Monitoring Panel: Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start/stop arrangement, indications for engine parameters, hour run meter, RPM meter, engine oil pressure indicator, water/coolant temperature indicator, battery volt display.(xii) Safety Controls: Engine low lube oil pressure high water temperature and over speeding of engine |
| 143 | (xiii) Coupling arrangement : Flexible coupling, fly wheel to suit flexible coupling(xiv) Accessories : AVM pads built or separtely mounted to manufacturer base frames.(xv) Base frame: Made out of ISMC 250 of sturdy design made of MS channel or as recommended by manufacturer.(C) AMF panel: Factory made indoor type control cubical made out of 2 mm thick CRCA sheet dust and vermin proof totally enclosed with front and rear opening of 415 Volts, 3 phase, 4 wire, AC, 50 Hz, including powder coated, aluminum bus bar of one and half times the rated load of 750 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 Volts grade of suitable capacity,fuses name plates consisting of 4 pole MCCB\"s and contactors and relays of capacity as recommended by the manufacturer, detachable cable gland plates all controls, indicators andMicro processor base LED/LCD display for indication voltage, current, frequency, speed, KW, KWH, PF, temperature,battery voltage,etc with the following:- |
| 144 | (i) indicator lamps - 3 Nos, (ii) Fuse set - 3 Nos (iii) Annuciation with indication lamps for :- (a) Low lub oil pressure (b) High water Temparature(c) Engine over speed (iv) Battery low voltage Controls :- (a) Load on Indication(b) Load off indication(c) Engine start push button (d) Engine stop push button(v) Fault accept/Reset push button(vi) Battary Charger : (a) Transformer (b) Rectifier (c) Resistance (d) DC Volt meter(e) Charger rate selector switch(D) Accoustic Enclosure : Manufactured by OEM suitable for 750 KVA DG Set(i) NAL approved as per CPCB(ii) It should be as per latest rules and regulations of Ministry of Environment and Forest and pollution control board |
| 145 | (iv) Fuel tank should be inside the enclosure and the capacity of the tank for 12 Hrs run the DG Set.(v) construction details/specification are as follows:(vi) Outer Body : CRCA sheet of 1.6 mm thick(vii) Doors CRCA sheet of 1.6 mm thick(viii) Sound insulation : As per OEM Norms.(ix) The accoustic should be composite in construction and fully assembled integral unit(x) The batteries should be placed inside the enclosure beside the DG set on a suitable insulated plat form(xi) The cost of the fuel pipe lines is deemed to be included in the quoted rate.(xii) The DG Set should be provided with externalEmergency stop push button(xiii) The enclosure should be suitably illluminatedby CFL/FTL/LED lamp fittings(xiv) The noise level should be 75 dB at 1m under freefield conditions |
| 146 | (xv) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set green.The base frame should be painted with epoxy based black shade(xvi) Rubber matting of LV grade 19 mm thick of suitable size, chequered type, ISI marked shall be laid in front of control panel.(E) Testing: The DG set shall be tested for a period Not less than 12 hours continuously out of which at least 1/2Hr on No Load and 02 hrs on 25% load, 02 hours each on 50% and 2.5 hrs on 75 % of rated full load, 4 hours on rated full load and 01 hours on 10% in exceess of rated full load.Necessary load shall be given on connected load. If the required full load for testing purpose is not available at the site, artificial load has to be arranged by the contractor for the testing. All instruments, consumable stores like engine oil, grease required for carrying out the tests including manpower shall be provided by the contractor. Contractor shall arrange DHPP for testing of DG set . Unit rate quoted shall deemed to include cost of the same. |
| 147 | All as per item above but of capacity 625 KVA |
| 148 | All as per item above but of capacity 200 KVA |
| 149 | Obstruction Light |
| 150 | S&F Obstruction Lights red colour twin LED light fitting complete all as specified. |
| 151 | Air compressor |
| 152 | S&F Air compressure 10 hp 7.5 kw capacity of air receiver 500 ltrs complete with hose reel nozzel and connected items complete all as specified and as directed |
| 153 | S&F pvc round copper conductor of 3 core 4 sqmm incl 15 amp top plug complete all as specified and as directed |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail