| 1 | Supply and laying aluminium strip 25x3.15mm with insulator 1 meter interval, saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed. |
| 2 | Supply and laying Copper strip 20x3.15mm with insulator 1 meter interval, saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed. |
| 3 | Supply and laying GI strip 32x6mm with insulator 1 meter interval, saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed. |
| 4 | S&F Air termination rod, single pointed aluminium rod 12mm dia and 300mm long, complete all as specified and directed. |
| 5 | S&F test point terminal block made of GI size 75x75x25mm drilled and screwed including dia 25mm long head screw, complete all as specified and directed. |
| 6 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion including galavanised strip protected by 32mm bore light grade galvanised iron pipe and earth and connected to test point as directed including funnel, watering pipe 20mm bore light grade galvanised iron wire mesh charcol and common salt in alternate layers of 15 cm compacted thickness all around the GI electrode with concrete pit 1:3:6, type C-1, including necessary excavation in soft/loose soil and disposal of soil to a distance not exc 50 m and necssary testing complete connected to eathing test point, complete all as specifed and directed. |
| 7 | All as per Srl item No 6.00 above but for using galvanised iron strip 32x6mm as earthing lead, complete all as specified and directed. |
| 8 | All as per Srl item No 6.00 above but for using copper plate 600x600x3.15mm and copper strip 20x3mm as earthing lead, complete all as specified and directed. |
| 9 | Supply and Laying 20mm tubes medium grade galvanised, with all fitting including trenches/ wall/ floor complete all as specified and directed. |
| 10 | Supply and Laying 40mm tubes medium grade galvanised, with all fitting including trenches/ wall/ floor, complete all as specified and directed. |
| 11 | S&F ceramic/ procelain red earthing strip Insulator, size of 25x6 mm complete all as specified and directed. |
| 12 | M&L for PCC 1:3:6, type D-2, using 20mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specificed and directed . |
| 13 | S&F hybrid grounding device 240KA that provides 99.99% protection from lightning surges, noises, ESD, grounding electric current which enter power lines along with prefect ground (earth to neutral voltage less than 1.0V) to be connected in parallel, USA patent, confirming to CE, tested and certified as per IEC-ISO 9000 & ISO 14001- 2015 with all accessories complete all as specified as directed. Make: SN ENGINEERING or equivalent as approved. |
| 14 | S&F galvanized zinc metallic zinc coated Iron earthing Electrode speciallized developed for high sensitive equipment. Model SN001 (LXXVI MM ) as per Cpri 300 Cm long. Tested on 52.kA, C % 12 max, mn 0.60%mm class type GALV. Yield strength 329, tensile Strength 426, Elongation Bend/Flattering.Thickness Internal disposes\" 2 inch x6mm with base plate 3.15 to close the earthing rod. Terminal 2 inchx6mm filled with highly conductive compound which increase the life of Earthing electrode. Composition of chemical filled in Electrode water solubility . Grain size 100 mesh, along with SN make BFC Compound non toxic, non reactive, non explosive and non corrosive, longerlife Easytomaintain less space consistent results. Earthing Pitand Chamber Cover complete all as specified as directed. Make: SN ENGINEERING or equivalent as approved. |
| 15 | S&F Burnished metallic brown 99.69%,ly Non Galvanized non electrolyte earthing electrode with exothermic welding / breezing Welding at top of earthing electrode. Earthing equivalent SN modelSN001 (LXXVI mm) dia 300 CMLONGWithChemicalfilledin electrode... chemical analysis highly, Thickness Internal dispose, 2inch x6mm with base plate 3.15 to close the earthing rod. Terminal 2inch x6mm filled with highly conductive compound which increase the life of Earhing electrode.Composition of chemical filled in electrode water Solubility, acidsolubility grainsize 100mesh, alongwith SN makes BFC compound non toxic, non reactive, nonexplosive and non corrosive, longer life easy to maintain less spaceconsistent results, with earth pit chamber cover complete all as specified as directed. Make SN ENGINEERING or equivalent as approved. |
| 16 | M&L for submain wiring with 2x6.0Sqmm+1x6.0Sqmm earth wire single core PVC insulated FRLS-H, PVC sheathed cooper cableconnecting to common earth dolly in and including heavy duty PVC Concealed Conduit as per site requirement and direction by EIC, with all accessories complete all as specified and directed. Note: Three runs of copper wire for phase, neutral, earth & one run PVC conduit/ casing shall be measured as one unit length. |
| 17 | All as per Srl item No 16.00 above but fpr 2 run of single core 4 Sqmm FR PVC insulated unsheathed multistranded copper conductor cable and one run of 4.0 Sqmm FR PVC insulated unsheathed multistrandedcopper conductor earth wire complete all as specified and direceted. |
| 18 | Supply, installation, testing and commissioning factory made, LT bus bar panel board cubical, Outdoor type, floor/ground mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts, made of 3.15mm thick CRCA sheet , air Neoprene adhesive type gasket, vermin proof, as per IS specification and thimbles including cable entry glands, Base frame of the panel shall be made of angle iron of size 650x450x130mm comprising. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with and comprising of the following:- (i) Microprocessor MCCB Adjustable Overload, Short-circuit, Ground fault (4 Pole) & Fixed Instantanous Netural Protection (4 Pole) and capacity 200 Amp 4 Pole ICU = ICS = 36 KA - 01 No. (As Main Incoming), One Standby) (ii) MCCB TPN 63 Amps, 36 kA - 04 Nos (Outgoing), (iii) MCB 10 Amps, 25 kA, (iv) Indicator lamp RYB |
| 19 | S&F sheet metal enclosure MCB DB 4 way TPN double door suitable for 415 V, IP 54 fixed flushed on walls, including cutting knitch and making good disturbed surfaces, complete all as specified and directed.Make : L&T/ Legrand/ Schneider. |
| 20 | S&F sheet metal enclosure MCB DB 12 way, SPN double door suitable for 240 V, IP 54 fixed flused on walls including cutting Knitch and making good disturbed surfaces, complete all as specified and directed.Make: L&T/ Legrand/ Schneider. |
| 21 | S&F sheet metal enclosure MCB DB 8 way, SPN double door suitable for 240 V, IP 54 fixed flused on walls including cutting Knitch and making good disturbed surfaces complete all as specified and directed. Make: L&T/ Legrand/ Schneider. |
| 22 | S&F sheet metal enclosuresDB\"s 4 waySPNdoubledoor suitable for 240 V, IP 54complete all as specified and directed. Make: L&T/ Legrand/ Schneider. |
| 23 | S&F MCB SP (single pole ) 06 to 32 Amps \"B\" Curve with 10 kA for inductive load connected through cable lugs of suitable size complete all as specified and directed. Make: L&T/ Legrand/ Schneider. |
| 24 | S&F MCB SPN/ DP (single pole and neutral) 32/ 40 Amps \"B\" Curve with 10 kA for inductive load connected through cable lugs of suitable size, complete all as specified and directed.Make: L&T/ Legrand/ Schneider. |
| 25 | S&F MCB SPN/ DP (single pole & neutral) 240 volt 63 amp \"B\" curve with 10 kA for inductive loadconnected through cable lugs of suitable size, complete all as specified and directed. Make: L&T/ Legrand/ Schneider. |
| 26 | S&F MCB TP (single pole & neutral) 415 volt 25 to 63 amp \"B\" Curve with 10 kA for inductive loadconnected through cable lugs of suitable size, complete all as specified and directed. Make: L&T/ Legrand/ Schneider. |
| 27 | S&F MCB TPN/ FP (single pole & neutral) 415 volts 40 to 100 amp \"B\" Curve with 10 kA for inductive loadconnected through cable lugs of suitable size, complete all as specified and directed. Make: L&T/ Legrand/ Schneider. |
| 28 | S&F MCCB 4 Pole 415 V fixed type 25 to 100 Amps with breaking capacity 16 KAfor inductive loadconnected through cable lugs of suitable size, complete all as specified and directed. Make: L&T/ Legrand/ Schneider. |
| 29 | S&F MCCB 4 Pole 415 V fixed type 125 to 160 Amps with breaking capacity 16 KAfor inductive loadconnected through cable lugs of suitable size, complete all as specified and directed. Make: L&T/ Legrand/ Schneider. |
| 30 | S&F in repair surge protection device (SPD) voltage protection level Up upto 1.3 kV, suitable for protection of all terminal equipments both common & differential mode protection complete all as specified & directed. Make : Havells, SKU: DHSA2NAN40320 SP+N |
| 31 | S&F AC single phase static energy meter of accuracy class 1.0, 240 V, 50 Hz with Backlit LCD display of rating 5 - 30 A, (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power with transparent hinge type boxincluding fixing all arangements, complete all as specified and directed. |
| 32 | S&F PVC casing capping of 25mm (1\") width, Insulator with copper stranded conductor cable 1100V grade ISIsize 1.5 Sqmm complete all as specified and directed. Make:- Havells/ Polycab or equivalent as approved. |
| 33 | S&F in replacement round type bed side lamp mounting LED luminaire 18/20 Watt including making arrangment in ceiling as per the size of fittings and connecting twin core cable up to nearest point complete with Inbuit/separate electronic driver & high brightnessLEDs Natural white colour, complete all as specifed and directed. Make:- Havells cat part No EDGESURFACERDDLR 18W LED 865S or equivalent as approved. |
| 34 | S&F in repair single core PVC Insulator with copper stranded conductor cable 1100V grade ISIsize 1.5 Sqmm, complete all as specified and directed.Make:- Havells/ Polycab/ SCI |
| 35 | S&F in repair single core PVC Insulator with copper stranded conductor cable 1100V grade ISIsize 2.5 Sqmm complete all as specified and directed.Make:- Havells/ Polycab/ SCI |
| 36 | S&F in repair single core PVC Insulator with copper conductor cable 1100V grade ISI size 4.0 Sqmm, complete all as specified and directed.Make:- Havells/ Polycab/ SCI |
| 37 | S&F in repair single core PVC Insulator with copper conductor cable 1100V grade ISIsize 6.0 Sqmm complete all as specified and directed.Make:- Havells/ Polycab/ SCI |
| 38 | S&F in repair service cable 6.0 sqmm x 2 core PVC Insulator with aluminium conductor cable 230V grade ISI, complete all as specified and directed.Make:- Havells/ Polycab/ SCI |
| 39 | S&F in repair service cable 10.0 sqmm x 2 core PVC Insulator with aluminium conductor cable 230V grade ISI, complete all as specified and directed. |
| 40 | M&L for ACP sheet 3mm thickness for Glow sign board with suitable required size of board including size & shape of letter work complete all as specified and directed. |
| 41 | M&L for alex acrylic letter 3mm, 25mm depth with LED module make of samsung or in equivalentincluding 1mm electrical wire for glow sign board with suitable required size of board including size & shape of letter work, complete all as specified directed. |
| 42 | S&F framed work such as grills, gratings, etc with end bars shouldered and /or riveted, or forged into spikes, frames guard bars, barred iron doors ladders framed balusters, walk ways, railings, framework of water tanks and similar wor fonforming to Fe- 290, Gde E-165, including painting, complete all as specifed and directed. |
| 43 | S&F framed work such as T-sec, L-section flat, etc for frame work to aluminium, complete all as specifed and directed. |
| 44 | M&L for ACP board 3x4 feet sheet 3mm thickness with vinyl printing as per sample of drawith/ schemetic diaghram etc suitable required size of board including shape of letter work, complete all as specified directed. |