| 1 | 16A AMMETER SELECTOR SWITCH FOR MAIN INPUT CURRENT SELECTION | 16A AMMETER SELECTOR SWITCH FOR MAIN INPUT CURRENT SELECTION |
| 2 | 16A VOLTMETER SELECTOR SWITCH FOR MAIN INPUT VOLTAGE SELECTION | 16A VOLTMETER SELECTOR SWITCH FOR MAIN INPUT VOLTAGE SELECTION |
| 3 | 10A TP AC 2 WAY WITHOUT OFF AUTO or MANUAL MODE SELECTION FOR FLOAT and BOOST CHARGERS | 10A TP AC 2 WAY WITHOUT OFF AUTO or MANUAL MODE SELECTION FOR FLOAT and BOOST CHARGERS |
| 4 | 16A SP DC 2 WAY WITHOUT OFF SWITCH FOR FLOAT RECTIFIER or LOAD BUS AND BOOST RECTIFIER or BATTERY VOLTAGE SELECTOR SWITCH | 16A SP DC 2 WAY WITHOUT OFF SWITCH FOR FLOAT RECTIFIER or LOAD BUS AND BOOST RECTIFIER or BATTERY VOLTAGE SELECTOR SWITCH |
| 5 | 16A SP AC 2 WAY WITHOUT OFF AUTO C or O MODE or MANUAL BOOST MODE SELECTION FOR CHARGER | 16A SP AC 2 WAY WITHOUT OFF AUTO C or O MODE or MANUAL BOOST MODE SELECTION FOR CHARGER |
| 6 | 10A TP DC 2 WAY WITHOUT OFF FOR BOOST CHARGING OF BATTERY SET 1 or 2 SELECTION | 10A TP DC 2 WAY WITHOUT OFF FOR BOOST CHARGING OF BATTERY SET 1 or 2 SELECTION |
| 7 | 225A DC COIL OPERATED EMERGENCY CONTACTOR COIL 220V DC AUXI 1NO | 225A DC COIL OPERATED EMERGENCY CONTACTOR COIL 220V DC AUXI 1NO |
| 8 | 185A DC COIL OPERATED CONTACTOR FOR BOOST CHARGING BATTERY SET 1 COIL 220V DC AUXI 2 NC | 185A DC COIL OPERATED CONTACTOR FOR BOOST CHARGING BATTERY SET 1 COIL 220V DC AUXI 2 NC |
| 9 | 63A DP DC ON or OFF SWITCH FOR LOAD ISOLATION | 63A DP DC ON or OFF SWITCH FOR LOAD ISOLATION |
| 10 | 40A DC COIL OPERATED EMERGENCY CONTACTOR COIL 48V DC AUXI 1NO | 40A DC COIL OPERATED EMERGENCY CONTACTOR COIL 48V DC AUXI 1NO |
| 11 | 65A DC COIL OPERATED CONTACTOR FOR BOOST CHARGING BATTERY SET 1 COIL 48V DC AUXI 1 NC | 65A DC COIL OPERATED CONTACTOR FOR BOOST CHARGING BATTERY SET 1 COIL 48V DC AUXI 1 NC |
| 12 | FILTER CAPACITOR FOR RIPPLE SUPPRESSION FOR FLOAT and BOOST CHARGERS RATING 100 V 2200 Uf | FILTER CAPACITOR FOR RIPPLE SUPPRESSION FOR FLOAT and BOOST CHARGERS RATING 100 V 2200 Uf |
| 13 | DC TO DC CONVERTOR 48V DC TO 24 V DC 5 AMPS | DC TO DC CONVERTOR 48V DC TO 24 V DC 5 AMPS |
| 14 | 4 CHANNEL RELAY BOARDS FOR CONTACT MULTIPLICATION OF CARD MOUNTED PROTECTION RELAYS | 4 CHANNEL RELAY BOARDS FOR CONTACT MULTIPLICATION OF CARD MOUNTED PROTECTION RELAYS |
| 15 | ELECTRONIC CARD MODULE FOR AVR and CURRENT LIMIT FOR FLOAT CHARGER AUTO and MANUAL MODE | ELECTRONIC CARD MODULE FOR AVR and CURRENT LIMIT FOR FLOAT CHARGER AUTO and MANUAL MODE |
| 16 | ELECTRONIC CARD MODULE FOR AVR and CURRENT LIMIT FOR BOOST CHARGER AUTO and MANUAL MODE | ELECTRONIC CARD MODULE FOR AVR and CURRENT LIMIT FOR BOOST CHARGER AUTO and MANUAL MODE |
| 17 | ELECTRONIC CARD MODULE FOR FLOAT and BOOST RECTIFIER FUSE FAIL and FILTER FUSE FAIL | ELECTRONIC CARD MODULE FOR FLOAT and BOOST RECTIFIER FUSE FAIL and FILTER FUSE FAIL |
| 18 | PROTECTION MODULE FOR VARIOUS FAULT DETECTION and ANNUNCIATION | PROTECTION MODULE FOR VARIOUS FAULT DETECTION and ANNUNCIATION |
| 19 | BLOCKING DIODE FOR FLOAT and BOOST CHARGER RATING 70A I AVG PIV 800 FOR FCB MODE ON K3 HEAT SINK | BLOCKING DIODE FOR FLOAT and BOOST CHARGER RATING 70A I AVG PIV 800 FOR FCB MODE ON K3 HEAT SINK |
| 20 | 80 percent BLOCKING DIODE STUD TYPE RATING 70A I AVG PIV 800 ON K3 HEAT SINK | 80 percent BLOCKING DIODE STUD TYPE RATING 70A I AVG PIV 800 ON K3 HEAT SINK |
| 21 | LATCHING RESISTOR FOR RECTIFIER. 250 OHMS 50 WATTS FOR FLOAT AND BOOST CHARGERS | LATCHING RESISTOR FOR RECTIFIER. 250 OHMS 50 WATTS FOR FLOAT AND BOOST CHARGERS |
| 22 | 10K 1W POTENTIOMETER FOR AUTO or MANUAL VOLTAGE ADJUST IN FLOAT CHARGER | 10K 1W POTENTIOMETER FOR AUTO or MANUAL VOLTAGE ADJUST IN FLOAT CHARGER |
| 23 | 10K 1W POTENTIOMETER FOR AUTO or MANUAL CURRENT ADJUST IN BOOST CHARGER | 10K 1W POTENTIOMETER FOR AUTO or MANUAL CURRENT ADJUST IN BOOST CHARGER |
| 24 | 2PH CONTROL TRANSFORMER FOR POWER SUPPLY OF AVR CARDS PRIM 415 V SEC 16 0 16 V AC 400MA | 2PH CONTROL TRANSFORMER FOR POWER SUPPLY OF AVR CARDS PRIM 415 V SEC 16 0 16 V AC 400MA |
| 25 | 3PH CONTROL TRANSFORMER FOR SYNCHRONISING OF AVR CARDS. PRI 415 V SEC 16 0 16 50MA | 3PH CONTROL TRANSFORMER FOR SYNCHRONISING OF AVR CARDS. PRI 415 V SEC 16 0 16 50MA |
| 26 | 3PH CONTROL TRANSFORMER FOR AC U or V PRI 415 V 3 PHASE SEC 0 16 VAC 1 PHASE 250 MA | 3PH CONTROL TRANSFORMER FOR AC U or V PRI 415 V 3 PHASE SEC 0 16 VAC 1 PHASE 250 MA |
| 27 | 2 0fi CONTROL TRANSFORMER FOR FAN CONTROL SUPPLY PRIM 415 V 2 PHASE SEC 190V AC 50VA | 2 0fi CONTROL TRANSFORMER FOR FAN CONTROL SUPPLY PRIM 415 V 2 PHASE SEC 190V AC 50VA |
| 28 | SCR STUD TYPE 70A WITH HEATSINK LOOSE MODULE ONLY | SCR STUD TYPE 70A WITH HEATSINK LOOSE MODULE ONLY |
| 29 | DIODE FREE WHEELING STUD TYPE 70A WITH HEATSINK LOOSE MODULE ONLY | DIODE FREE WHEELING STUD TYPE 70A WITH HEATSINK LOOSE MODULE ONLY |
| 30 | DIGITAL AC AMMETER 48 X 96 SQ MM CLASS 1 CT RATIO 25 or 1A AUXILIARY VOLTAGE 24V DC | DIGITAL AC AMMETER 48 X 96 SQ MM CLASS 1 CT RATIO 25 or 1A AUXILIARY VOLTAGE 24V DC |
| 31 | DIGITAL AC VOLTMETER 48 X 96 SQ.MM CLASS 1 RANGE 0 500V AC AUXILIARY VOLTAGE 24V DC | DIGITAL AC VOLTMETER 48 X 96 SQ.MM CLASS 1 RANGE 0 500V AC AUXILIARY VOLTAGE 24V DC |
| 32 | DIGITAL DC AMMETER FOR FLOAT BOOST CHARGERS and 80percentage CELL TAP 48 X 96 SQ MM CLASS 1 75mV DC WITH SHUNT AUXILIARY VOLTAGE 24V DC | DIGITAL DC AMMETER FOR FLOAT BOOST CHARGERS and 80percentage CELL TAP 48 X 96 SQ MM CLASS 1 75mV DC WITH SHUNT AUXILIARY VOLTAGE 24V DC |
| 33 | DIGITAL DC VOLTMETER 48 X 96 SQMM CLASS 1 RANGE 75mV DC AUXILIARY VOLTAGE 24V DC | DIGITAL DC VOLTMETER 48 X 96 SQMM CLASS 1 RANGE 75mV DC AUXILIARY VOLTAGE 24V DC |
| 34 | DIGITAL DC CHARGE or DISCHARGE AMMETER FOR BATTERY 48 X 96 SQ MM CLASS 1 RANGE 75mV WITH SHUNT AUXI 24V DC | DIGITAL DC CHARGE or DISCHARGE AMMETER FOR BATTERY 48 X 96 SQ MM CLASS 1 RANGE 75mV WITH SHUNT AUXI 24V DC |
| 35 | TRANSPORTATION CHARGES FOR MATERIAL | TRANSPORTATION CHARGES FOR MATERIAL |