| 1 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : a) All kinds of soil i) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 2 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : a) 1:2:4 (1 cement: 2 coarse sand (zone-ll) including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 20 mm nominal size including Recycled Concrete Aggregate (RCA) upto 25%) |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : a) 1:5:10 (1 cement : 5 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 10 graded stone aggregate 40 mm nominal size Recycled Aggregate (RA) ) |
| 5 | Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. |
| 6 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. a) Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 7 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required. A) bituminous portion cum |
| 8 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 9 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 10 | Laying old cement cocrete interlocking paver blocks of any design/shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in- charge. (Old CC paver blocks shall be supplied by the department. (free of cost). |
| 11 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filing the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. a) 60 mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. |
| 12 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : a) 100 mm diameter Class II |
| 13 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : a) 200 mm diameter Class II |
| 14 | Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : a) 80 mm dia |
| 15 | Providing and laying D.I. Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 : a) Up to 600 mm dia |
| 16 | Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329:a) 350 mmn dia Ductile Iron Class K-7 pipes |
| 17 | Providing, laying in standard lengths 110 mm nominal outer diameter (OD) High Density Polyethylene (H.D.P.E) Pipes of Grade PE-100/PN-10, confirming to IS 14333:2022 (amended upto date), including all local & central taxes, transportation and freight charges inspection charges, loading / unloading charges, conveyance to the departmental stores / site & stacking the same in closed shade duly protecting from sunrays & rain, etc and jointing with butt fusion welding joints conforming to DVS 2207 part-II complete in all respect as per directions of Engineer-incharge. |
| 18 | Providing, laying in standard lengths 200 mm nominal outer diameter (OD) High Density Polyethylene (H.D.P.E) Pipes of Grade PE-100/PN-10, confirming to IS 14333:2022 (amended upto date), including all local & central taxes, transportation and freight charges inspection charges, loading / unloading charges, conveyance to the departmental stores / site & stacking the same in closed shade duly protecting from sunrays & rain, etc and jointing with butt fusion welding joints conforming to DVS 2207 part-II complete in all respect as per directions of Engineer-incharge. |
| 19 | Providing, laying in standard lengths 225 mm nominal outer diameter (OD) High Density Polyethylene (H.D.P.E) Pipes of Grade PE-100/PN-10, confirming to IS 14333:2022 (amended upto date), including all local & central taxes, transportation and freight charges inspection charges, loading / unloading charges, conveyance to the departmental stores / site & stacking the same in closed shade duly protecting from sunrays & rain, etc and jointing with butt fusion welding joints conforming to DVS 2207 part-II complete in all respect as per directions of Engineer-incharge. |
| 20 | Providing flanged joint to 110 mm nominal outer diameter (OD) High Density Polyethylene (H.D.P.E) Pipes of Grade PE-100/PN-10 including all local & central taxes, transportation and freight charges inspection charges, loading / unloading charges etccomplete in all respect as per directions of Engineer-incharge. (Rates are inclusive ofall labour & material such as longneck collar, slipon flange, nut bolts etc). |
| 21 | Providing flanged joint to 200 mm nominal outer diameter (OD) High Density Polyethylene (H.D.P.E) Pipes of Grade PE-100/PN-10 including all local & central taxes, transportation and freight charges inspection charges, loading / unloading charges etccomplete in all respect as per directions of Engineer-incharge. (Rates are inclusive ofall labour & material such as longneck collar, slipon flange, nut bolts etc). |
| 22 | Providing flanged joint to 225 mm nominal outer diameter (OD) High Density Polyethylene (H.D.P.E) Pipes of Grade PE-100/PN-10 including all local & central taxes, transportation and freight charges inspection charges, loading / unloading charges etc complete in all respect as per directions of Engineer-incharge. (Rates are inclusive ofall labour & material such as longneck collar, slipon flange, nut bolts etc). |
| 23 | Deploying one no. fitter(2nd class) for day to day operation of sluice valve located at different locations of pipelines and all other works related to pipelines as per the direction of Engineer-in-charge. |
| 24 | Credit on account of HDPE Scrap retrived from dismantled HDPE pipe. |
| 25 | Add Cost Index @3% on SI. No. 1 to 16 (DSR Items) |
| 26 | Apply GST correction factor @ 0.973Note :-1) After intimation of leakage of pipeline, if the pipeline not repaired within 24 hours, penalty of Rs. 5,000/- Per day will be imposed and shall be recovered from the bill of the agency. 2) If the leakage in pipeline not repaired even after 72 hours of intimation, then the penalty of Rs 10,000/- per day will be imposed and shall be recovered from the bill of the agency. |