| 1 | (10.1) Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete . |
| 2 | D044-10.1A_Steel Fabrication Single section_(D044-10.1A)_(10)Steel(10.1)_Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete . Steel structural(10.1A)material will be issued free of cost from BHEL @ stores. |
| 3 | (10.2) Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 4 | D046-10.2A_Steel Fabrication Built-up section_(D046-10.2A)_(10)Steel(10.2)_Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete(10.2A)material will be issued free of cost from BHEL @ stores. |
| 5 | (13.61) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :(13.61.1) Two or more coats on new work. |
| 6 | D049-13.61.1_Synth-Enamel-Paint-2coats_(D049-13.61.1)_(13)Finishing(13.61.1)_Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : (13.61.1) Two or more coats on new work.(13.61.1A)Applicable for fabricated structural steel works. Painting Co-efficient for fabricated structural will be taken as 22.19Sqm/MT. |
| 7 | (13.62) Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: (13.62.1) Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 8 | D050-13.62.1_Synth-Enamel-Paint-2coats_(D050-13.62.1)_(13)Finishing(13.62.1)_Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: (13.62.1) Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. (13.62.1A)Applicable for fabricated structural steel works. Painting Co-efficient for fabricated structural will be taken as 22.19Sqm/MT. |
| 9 | (13.63) Painting with aluminium paint of approved brand and manufacture to give an even shade .(13.63.1) Two or more coats on new work |
| 10 | D051-13.63.1_Synth-Enamel-Paint-2coats-new work_(D051-13.63.1)_(13)Finishing(13.63.1)_(13.63) Painting with aluminium paint of approved brand and manufacture to give an even shade .(13.63.1) Two or more coats on new work (13.63.1A)Applicable for fabricated structural steel works. Painting Co-efficient for fabricated structural will be taken as 22.19Sqm/MT. |
| 11 | (13.99) Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :(13.99.1) One or more coats on old work. |
| 12 | D053-13.99.1B_Synth-Enamel-Paint_(D053-13.99.1B)_(13)Finishing(13.99.1)_(13.99) Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :(13.99.1) One or more coats on old work. (13.99.1B)Applicable for fabricated structural steel works. Painting Co-efficient for fabricated structural will be taken as 22.19Sqm/MT. |
| 13 | (13.100) Painting with aluminium paint of approved brand and manufacture to give an even shade : (13.100.1) One or more coats on old work. |
| 14 | D054-13.100.1_Aluminium-Paint_(D054-13.100.1)_(13)Finishing(13.100.1)_(13.100) Painting with aluminium paint of approved brand and manufacture to give an even shade : (13.100.1) One or more coats on old work. (13.100.1A)Applicable for fabricated structural steel works. Painting Co-efficient for fabricated structural will be taken as 22.19Sqm/MT. |
| 15 | (10.7) Providing and fixing of the following Rolling shutter spares in the existing rolling shutters including removal of damaged/ wornout spares.(10.7A) Providing and fixing ball bearing for rolling shutters. |
| 16 | D055-10.7_Synth-Enamel-Paint_(D055-10.7)_(10)Steel(10.7)_(10.7) Providing and fixing of the following Rolling shutter spares in the existing rolling shutters including removal of damaged/ wornout spares.(10.7A)Providing and fixing 60 cm long wire spring grade no 2 for rolling shutters. |
| 17 | (10.8) Extra for providing mechanical device chain and crank operation for operating rolling shutters.(10.8.1) Exceeding 10.00 sqm and upto 16.80 sqm in the area. |
| 18 | (10.8) Extra for providing mechanical device chain and crank operation for operating rolling shutters.(10.8.2) Exceeding 16.80 sqm in area. |
| 19 | D045-10.1B_Steel Fabrication Single section_(D045-10.1B)_(10)Steel(10.1)_Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete . Steel structural(10.1B)(Fabrication of structural steel without erection in position of fabricated items). |
| 20 | D047-10.2B_Steel Fabrication Built-up section_(D047-10.2B)_(10)Steel(10.2)_Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete(10.2B)(Fabrication of structural steel without erection in position of fabricated items). |
| 21 | D056-16.17.1_Barbed wire fence_(D056-16.17.1)_(16)Roads(16.17.1)_Laying/rectifying the existing barbed wire fencing in position with proper tension and alignment by means of providing necessary hook bolts and nuts with washer, 16 gauge GI binding wires, etc. complete. the rate includes conveyance of barbed wire from BHEL stores to site of work.(16.17.1A)(Barbed wire will be issued at free of cost by BHEL) |
| 22 | D057-16.70.2_Chain link fence_(D057-16.70.2)_(16)Roads(16.70.2)_Fixing of G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete. As per the direction of engineer-in-charge. Made of GI wire 4mm, PVC coated to achieve outer dia. Not less than 5 mm in required colour and shade. (16.70.2A)Chain link fencing will be issued at free of cost. |
| 23 | D052-13.99.1A_Synth-Enamel-Paint_(D052-13.99.1A)_(13)Finishing(13.99.1)_(13.99) Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :(13.99.1) One or more coats on old work. (13.99.1A)(Paint will be issued at free of cost by BHEL) |
| 24 | D048-10.2C_Steel Fabrication Built-up section_(D048-10.2C)_(10)Steel(10.2C)_Carrying from stacks at erection site to erection position and erection of fabricated steel work including all handling, conveying, leading, assembling, hoisting and erection in position and site welding and or bolting wherever required and alignment of the structure as per drawing and specification. Rate to be all inclusive such as bolts and nuts, welding, tools and plants, labour charges etc., complete excluding cost of fabricated components. |
| 25 | (10.22) Welding by gas or electric plant including transportation of plant at site etc. complete. |
| 26 | (15.18) Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 27 | (D84-FSMT)_(D84)Servicing of each shutter by applying grease, oil wherever required. If any defect is noticed , Engineer-in-Charge should be informed in writing indicating the location of shutter, nature of defect, spare parts required etc., complete. |
| 28 | (D85.1-FSMT)_(D85)Supply of the following man power for carring out emergency work in various buildings for attending of various maintenence works in Factory complex.(D85.1)Welder (SSW) |
| 29 | (D85.2-FSMT)_(D85)Supply of the following man power for carring out emergency work in various buildings for attending of various maintenence works in Factory complex.(D85.2)Fitter (SSW) |
| 30 | (DAT.CP16.46.1) Arresting the leakage in and around the `L\" or `J\" bolt joints of AC sheets and AC sheet cracks, etc. with applying bitumen compound. Rate includes labour charges, cost of bitumen compound, etc. all as per the instructions of engineer-in-charge. |
| 31 | (D86-FSMT)_(D86)Cleaning the existing rain water gutter joints in shop floor, by scraping the existing FRP sealant/bitumen sealant and cleaning the joint upto the metal surface free from dust and rust, filling the gap in the joint by repeated layers/fillets of welding without any leakage of rain water. rate to be all inclusive of labour charges for cleaning and for removing the AC sheets, NL glass and fixing it properly after welding and other incidental charges, etc., complete |
| 32 | (14.90) Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm.Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :(14.90.1) 3 mm thick |
| 33 | (12.1) Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (12.1.1) 1.00 mm thick with zinc coating not less than 275 gm/m² |
| 34 | (D206A-FSMT)_(D206)Providing and fixing on wall face unplasticised Rigid PVC rain water pipes confirming to IS 14735 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion.Note: The following items under 24 - A to E. Rate should include cost of specials, consumables, labour, other incidental charges etc.(D206A)160 mm dia. single socketed pipes |
| 35 | (D207B-FSMT)_(D207)Providing and fixing on wall face unplasticised Rigid PVC rain water pipes confirming to IS 14735 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion. Note: The following items under 24 - A to E. Rate should include cost of specials, consumables, labour, other incidental charges etc.(D207B)160 mm dia. Shoe |
| 36 | (D207C-FSMT)_(D207)Providing and fixing on wall face unplasticised Rigid PVC rain water pipes confirming to IS14735 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion. Note: The following items under 24 - A to E. Rate should include cost of specials, consumables, labour, other incidental charges etc.(D207C)160 mm dia. Bend |
| 37 | (D207D-FSMT)_(D207)Providing and fixing on wall face unplasticised Rigid PVC rain water pipes confirming to IS14735 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion. Note: The following items under 24 - A to E. Rate should include cost of specials, consumables, labour, other incidental charges etc.(D207D)160 mm dia. \"T\" |
| 38 | (D207E-FSMT)_(D207)Providing and fixing on wall face unplasticised Rigid PVC rain water pipes confirming to IS 14735 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion. Note: The following items under 24 - A to E. Rate should include cost of specials, consumables, labour, other incidental charges etc.(D207E)160 mm dia. \"Y\" with Door |
| 39 | (D87-FSMT)_(D87)Treatment for Gutter : Providing and laying epdm membrane of 1.2mm thick of \"Dr.Fixit Flexshield\" or equivalent of having 300% elongation and 7 Mpa tensile strength and 27 KN/m tear strength, conforms to ASTM D 412, applied over a clean and dry surface to fully bonded with Dr.Fixit Flexshield Adhesive or euivalent including surface preparation, reprofile the distressed portion with Dr.Fixit Pidicrete URP modified mortar or equivalent etc , complete as per specification. |
| 40 | (12.7) Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.(12.7.1) 0.80 mm thick with zinc coating not less than 275 gm/m² |
| 41 | (DAT.23) Carrying from stores to site of work sizing, bending to the required shape and dimension and fixing of GI sheets for flashing. rate to include fixing of GI sheet with all accessories in proper line, level, etc. including all labour and incidental charges, etc., complete. GI sheets at random length will be supplied by BHEL free of cost, at BHEL stores. |
| 42 | (DAT.24) Carrying from BHEL stores and fixing of corrugated G.S.sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheetscomplete (up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (DAT.24.1) 1.00 mm thick with zinc coating not less than 275 gm/m? (G.S Sheets will be issued at free of cost by BHEL) |
| 43 | (DAT.25) Carrying from BHEL stores and fixing of Pre-painted galvalume Zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa and Corrugated G.S.sheet roofing including vertical/curved surface fixed with polymer coated as in roof covering / cladding to wall ,fixed with self tapping screws as specified and other incidental charges, etc., complete including loading, leading, placing & fixing in position, scaffolding charges, hire and running charges for tools and plants. The measurement shall be based on actual laid area. (DAT.25.1) 1.00mm thick with zinc coating not less than275 gm/m? (G.S sheets will be issued at free of cost by BHEL)but for Ridges, Hips, Valley Gutter, Drip and Straight Flashing . |
| 44 | (D12.50A-TSMT)_(D12.50A)Carrying from BHEL store and fixing of color coated trapezoidal profiled roofing sheet as per IS 513 - Mild steel with base metal thickness of 0.5 mm of any colour having tensile strength of 240 mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified and other incidental charges, etc., complete including loading,leading,placing & fixing in position, scaffolding charges, hire and running charges for tools and plants. The measurement shall be based on actual laid area. |
| 45 | (DAT.26) Carring from BHEL store and fixing of color coated trapezoidal profiled roofing sheet as per IS 513 - Mild steel with base metal thickness of 0.5 mm of any colour having tensile strength of 240 mpa as in roof covering / cladding to wall ,fixed with self tapping screws as specified and other incidental charges, etc.,complete including loading,leading, placing & fixing in position, scaffolding charges, hire and running charges for tools and plants. The measurement shall be based on actual laid area. (DAT.26.1) Same as item No 13 above but for Ridges, Hips, Velley gutter, Drip and straight Flashing. |
| 46 | (D12.50-TSMT)_(D12.50)Supply and fixing of color coated trapezoidal profiled roofing sheet as per IS 513 - Mild steel with base metal thickness of 0.5 mm of any colour having tensile strength of 240 mpa as in roof covering / cladding to wall ,fixed with self tapping screws as specified and other incidental charges, etc.,complete including loading,leading, placing & fixing in position, scaffolding charges, hire and running charges for tools and plants. The measurement shall be based on actual laid area. |
| 47 | (D12.51.1-TSMT)_(D12.51.1)Supply and fixing of color coated plain ridge of size 500 mm (width) x1250 mm (length) profiled ridge sheet as per IS 513 - Mild steel with base metal thickness of 0.5 mm of any colour having tensile strength of 240 mpa as in roof covering / cladding to wall ,fixed with self tapping screws as specified and other incidental charges, etc., complete. |
| 48 | (15.28) Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:(15.28.1) G.S. Sheet |
| 49 | (15.28) Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:(15.28.2) Asbestos cement sheet |
| 50 | (D281CFSMT)_(D281)Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of :(D281C)FRP sheets 3 mm thick |
| 51 | (D88-FSMT)_(D88)Cleaning and removing all foreign materials and debris deposited in the rain water gutters provided in shops whenever required and disposing them at the specified places as instructed by the engineer-in-charge. |
| 52 | (15.42) Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead :(15.42.3) 150 mm dia pipe |
| 53 | (D12.51.3-FSMT)_(D12.51.3)Carrying and fixing in position of 6mm thick wired glass in roof north light glazing including straightening the aluminium astrangle as required. Rate includes cost of labour , tools & tackles etc., complete. Required glass ,aluminium astrangle will be issued at Civil Factory stores at free of cost. |
| 54 | (D89-FSMT)_(D89)Laying of new rails in proper alignment, level, tightening of bolts after placing the rail clips, greasing the bolts (grease to be supplied by department). Leading, lifting, positioning of new rails, straightening of new rails if warranted has to be to done by the contractor. The work has to be done without damaging any of the existing facilities in the shop. Work has to be completed with proper clearance from shop. Bolts, nuts, fish plates will be supplied from department. Rails may have to be cut in one or two places along the length of the bay which is included in the scope of erection. Necessary crane arrangement for erection of rail will be given by department free of cost subject to availability. ForAll Crane rails works (EOT/Gantry/Semi Gantry etc) |
| 55 | (D90-FSMT)_(D90)Preventive maintenance of EOT crane rails (on each side) of production bay by maintaining the rails in good conditions suitable for movement of cranes at all times by tightening bolts and nuts. cleaning the tracks removing all foreign materials like dust, iron rust, iron chips, oils, etc. complete. the rate is inclusive of all materials, equipment and labour for the entire work including cob web removal in the crane, gantry and auxiliary girders and surge lacing. |
| 56 | (D91-FSMT)_(D91)Upkeeping the EOT crane walk way on each bay including staircase by maintaining the walkways of staircase for movement of person at all times by cleaning the walkway, removing all foreign materials like cobweb dust, etc. complete and disposing the same at the specified places as instructed by the engineer-in-charge. |
| 57 | (15.19) Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge |
| 58 | (CVL-1.1.1A-CMT)_(1.1) Carriage of materials by mechanical transport including loading, unloading and stacking.(1.1.1) Lime, moorum, building rubbish.(1.1.1A) Upto 1Km |
| 59 | (DAT.35) Dismantling the B.G.track rails after removing the bolts, rail clips and fishplates, lowering and handing over to BHEL storeswithin 1 KM lead. Rate to include loading, leading unloading & stacking of rails. (DAT.35.1) Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in:R.S. Joists |
| 60 | (D92.1-FSMT)_(D92)Supply of the following man power for carring out emergency work in various buildings for attending of various maintenence works in Factory complex.(D92.1)USW |
| 61 | D058-12.50_2mmPolycarbonate Roof sheet_(D058-12.50)_(12)Roofing(12.50)_Supply and fixing 2 mm thick UV-stabilized corrugated embossed/clear polycarbonate roofing sheets of TILARA/SUNTUF/LOTUS or Equivalent make, colour, and quality, including cutting, aligning, and fixing with self-drilling / self-tapping screws with EPDM washers, overlaps, ridges, flashings, and all necessary accessories as per manufacturer’s specification and direction of Engineer-in-Charge. The work shall be completed in all respects to ensure water tightness and durability. |
| 62 | Carring from BHEL store and fixing of non-asbestos high impact Polypropylene reinforced cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required and other incidental charges, etc.,complete including loading, leading, placing & fixing in position, scaffolding charges, hire and running charges for tools and plants. The measurement shall be based on actual laid area. |
| 63 | (D94.1-FSMT)_(D94)Structural Maintenance,(Carring from BHEL store and fixing of non-asbestos high impact Polypropylene reinforced cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required and other incidental charges, etc.,complete including loading, leading, placing & fixing in position, scaffolding charges, hire and running charges for tools and plants. The measurement shall be based on actual laid area.)(D94.1)Applicable for Ridges, Hips, Velley gutter, Drip and straight Flashing. |