| 1 | Taking out Existing Street / securitylights any type and size andSupply andfixing LED street light fitting 90 watts ,140 V - 270 V, 50Hz AC outdoor type in replacement with high pressure die cast alluminium housing with top opening service and heat resistant complete with driver, lamp bracket , with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection , Light source High efficiency long life LED package modules on MCPCB with LED lumen efficacy of >100 lumen per watt, Electronic Driver Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection, Over Voltage protection, 10 kV surge protection,Surge Voltage protection & other safety tests as per IS 15885 Part-2/Sec13 completedto driverwith superior finish with top maintainable driver compartment complete withthe fittings arrangement for fixing on existing bracket etc complete all as specified and directed. (Note : LM 79 and 80 test certificate submitted before executing of the work) |
| 2 | Taking out Existing Flood lights any type and size andSupply andfixing LED flood light fitting 150 watts ,140 V - 270 V, 50Hz AC outdoor typein replacement with high pressure die cast alluminium housing with top opening service and heat resistant complete with driver, lamp bracket , with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection , Light source High efficiency long life LED package modules on MCPCB with LED lumen efficacy of >100 lumen per watt, Electronic Driver Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection, Over Voltage protection, 10 kV surge protection,Surge Voltage protection & other safety tests as per IS 15885 Part-2/Sec13 completedto driverwith superior finish with top maintainable driver compartment complete withthe fittings with two pairs of necessary nuts and bolts with washers with suitable packing arrangement to fixing complete all as specified and directed. (Note : LM 79 and 80 test certificate submitted before executing of the work) |
| 3 | Taking out Existing Street / securitylightsbracket any type and sizeandSupply and fixingof mounting bracket made of 40 mm bore (or higher size to suit the opening of fitting) light grade GI pipe of approx. 1.5 mtr length bent to shape of 1 mtr and fixed to pole withFI 40mm x 6mm clamps,2 nos and suitable size necessarynuts & bolts ,including Bracket complete set painting oftwo coat red oxide and aluminium paintedfittings for Street lights with swaged tubular/ PCC pole connectedcomplete all as specified and directed. |
| 4 | Supply, laying, jointing, testing and commissioning LT underground cables 16 sqmm x 4core, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-7098 (marked, laid in trenches / ducts / fixed on poles/ laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified and directed. (Note;- Rate quoted includes terminal Lugs /road cutting/ floor cutting/ Inter locking floorand making good damaged portion matching with existing surface with all existing finishes.)including taking old us cable any type and size. |
| 5 | Excavationin trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and gettingout in Soft/Loose soilincluding trimming sides and bottom of trenches complete all as specified and directed. |
| 6 | Returning, filling-in, including spreading, watering and well ramming in layers notexceeding 25 cm thick each, in soft /loose soil complete all as specified and directed. |
| 7 | Removing excavated surplus soil to a distance not exceeding50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 8 | Material and labour for riverwashed and screened, dry sand for filling in trenches below 8 cm laid before laying of cable and 15 cm sand cable laid after laying the cable andaround underground cablesfor cushioning of cables complete all as specified and directed. |
| 9 | M & L Bricks for protection cover to under ground cable (with standard size fly ash bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm complete all as specified and directed. |
| 10 | Taking out old unsv pole PCC andSupplying, transporting to site, erecting, and fixing in position, steeltubular swaged and welded poles of Overall height 9 metres, type 410 SP-31, IS-2713 marked, with mild steel base plate (filletwelded to poles), pole cap / finial taper plug, bolts, nuts, washers etc,including painting on the outside with two coats of aluminium paint over a coat of red oxide primer on exposed surfaces and black bituminous paint on steel surface embedded in concrete and painting 05 nos band /strips with fluorescent , PO box red synthetic enamel paint ( 30 cm wide each) at a distance of 30 cm fromplinth block of colour black and Green withnumbering of poles, including the existing service line/ Chanel/ street lights Brackets with street lights /JBs complete allied itemsshifting the new polecomplete all as specified and directed.(Note:- Poles shall be swaged and welded atmanufacturer’s factory and not at site. The inner surface shall be factory painted) |
| 11 | M&L for PCC (1:4:8)type D2 with 40 mm graded stone aggregate in foundation(below pole ) complete all as specified and directed. |
| 12 | M&L for cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate for foundation of pole etc. (around the poles in pit) complete all as specified and directed. |
| 13 | M&L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate for coping of poles including necessary form work, fair finishing to exposed surfaces using extra cement complete all as specified and directed. |
| 14 | Taking out existingunsv junction box any type and size and S&F pole mounting type junction box factory made of minimum size 290 x200x100mm of FRP sheet duly powder coated with front openable hinged door , locking arrangements, with 4 Nos aluminium bus bars 40 Amps ratingmounted on SMC /porcelain insulator, cable glands and lugs consisting DIN type rails for fixingMCB SP 6/10 Amps, 10 kA suitable for domestic loading , -01 no. including mild steel flat iron clamp and and supporting flat Ironmade out of 40x4mm FI, nuts, bolts and washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 15 | Taking out existingunsv conduitany type and size and Supply& fixing UnplasticisedPVC pipes of prssure rating 10Kgf/cmSq25 mm bore and 3mm thick complete fixed on pole using suitable clamps nuts & bolts (not less than 03 Nos) complete all as specified and as directed |
| 16 | Taking out existingunsv connection wireany type and size and S&F for one runs of three core 1.5 Sqmmx 3 core (nominal area) PVC insulated and PVC sheathed multi stranded unarmed copper conductor cable LT 1100 volt grade Confirming to IS : 7098 drawn through pipe/ polefor connecting to street light and pole JB with lugscomplete all as specified and directed. |
| 17 | Taking down unsv burnt timer panel any type and size and Supplying andfixing in repair automatic operation street light timing switch having lighting control (ON-OFF) through Astronomical Calculation of Sun rise/ sun set by setting date, time and degree of longitude and latitude without separate light sensors and prewired with suitable size of copper conductor single core PVC insulated and sheathed cable and all mechanism fitted into panel, outdoor type , pole mounted with FI 25x4mm clamps , nuts, bolts and washers dully painted,connecting and testing factory made , epoxy powder coated, Single Phase street light panel, Astronomical 24 hrs,suitable for 6KW (max) complete with 32 Amps TP Contactor, and 40 Amps TPN MCBs and fixedon pole/ wall/ feeder pillar complete all as specified and directed. |
| 18 | Taking out unsv DBs and MCB any type and Supply and fixing SPN DBs 2way forMCB complete with SPN Isolator 63 Amp, suitable for domestic loading, 240 Volt complete all as specified and directed. |
| 19 | Taking down of existing unserviceable Isolator DPand S & FIsolator DP,40 Amps, 240Volts ,\"C\" curve rating and to be housed in existing sheet metal enclosures ( distribution boxes)complete all as specified and directed. |
| 20 | Taking down of existing unserviceable Isolator TPNand S & FIsolator TPN,63 Amps, 415 Volts and to be housed in existing sheet metal enclosures ( distribution boxes)complete all as specified and directed . |
| 21 | Taking down of existing unserviceable wall fans and Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 22 | Supply & fixingin repair/replacement Sheet Metal Enclosures vertical TPN distribution board with provision for & including 100 Amp MCCB TP with breaking capacity 16kA as incomer with necessary internal wiring, MCBs as outgoing , 4 way, 415 Volt, Double door for housing MCB\"s/Isolators and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing complete all as specified and directed.including taking out old u/s DBs any capacity. |
| 23 | S&Fin repair/ replacement MCB SPN 63 Amps\"C\" Curve type breaking capacity 10kA, 240 V for fixing inside VTPN complete all as specified and directed |
| 24 | Supply & fixingin repair/replacement MCB DB Box 8 way 200 Amps capacity, 240 volts, Double door, SPN and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing complete all as specified & directed including taking out old u/s DBs any capacity. |
| 25 | Supply & fixingin repair/replacement MCB, SPN, AC, 240 volts of 63 Amps capacity 10KA, \"C\" series andmaking connections with suitable size of copper lugs complete all as specified & directed |
| 26 | Supply & fixing in repair/replacementMCB , SP, AC, 240 volts of 05 to 32Amps capacity 10KA, \"C\" series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 27 | M & L for sub main wiring with6 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed,FRLSH copper conductor stranded cable with and including continuous earth wire of size 6.0 Sqmm nominal cross sectional area, single core , PVC insulated, copper conductor stranded cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories/ fittings ,brass screws, washers etc and connected to common earth dolly including all cutting/ chases etc in wall, making good to walls etc including two coats of white/ colour washing/distempering etc to the disturbed surfaces to match the existing complete all as specified & directed including taking out old u/s sub main wiring any size. |
| 28 | S&F in repair/replacement 20 watts Light emitting Diode (LED) tube light fitting wall mounting , indoor decorativealuminium extruded T5 LED battens, Integrated type, AC 230-240V, 50 hz, with PMMA/PC diffuser, 4\" long, easy to install, Efficacy:100 lumen/watt, Minimum 3.5 KV Voltage Surge Protection, Power factor > 0.9, making connections with and including 23/.0076 flexible cord of required length from ceiling rose to connector complete all as specified and directed. |
| 29 | S&F in repair/replacement 10 watts Light emitting Diode (LED) tube light fitting wall mounting , indoor decorativealuminium extruded T5 LED battens, Integrated type,AC 230-240V, 50 hz, with PMMA/PC diffuser, 2\" long, easy to install, Efficacy:100 lumen/watt, Minimum 3.5 KV Voltage Surge Protection, Power factor > 0.9, making connections with and including 23/.0076 flexible cord of required length from ceiling rose to connector complete all as specified and directed. |
| 30 | M & L forLED Bulb 12 watt 240 volt complete all as specified and directed including taking out old unsbulb. |
| 31 | Supply & fixing in repair/replacement switch piano flush type, 05/06 Amps single pole , one way 240 volts complete all as specified & directed . |
| 32 | Supply & fixing in repair/replacement of bell push, flush type 05/06 Amps, 240 volts complete all as specified & directed . |
| 33 | Supply & fixing in repair/replacement bell, AC, 230 volts, single pole, ding dong typesize compete all as specified & directed. |
| 34 | Supply & fixing in repair/replacement switch piano flush type, 15 /16 Amps single ploe, one way 240 volts complete all as specified & directed . |
| 35 | Supply & fixing in repair/replacement socket outlet 3 pin, 05/06 Amps (2 -in-1 Multipurpose) flush type 240 volts complete all as specified & directed. |
| 36 | Supply & fixing in repair/replacement of socket outlet 3 pin, 15/16 Amps (2 -in-1 Multipurpose) flush type 240 volts complete all as specified & directed. |
| 37 | Supply & fixing in repair/replacement ceiling fan regulator, flush type, hum free, AC, 230 volts, 100 watts duty ISI Marked with and including modular white surround complete all as specified & directed. |
| 38 | Supply & fixing in repair/replacement lamp holder (Angular/Straight), insulated body, with back plate for batten fitting complete all as specified & directed |
| 39 | Attending the complaints for checking of existing electrical fittings and fixtures in qtrs at sectors area for continuous electric supply including carrying out minor repairs etc as required to make the items functional and replacing tube rods, chokes, CFLs, copper cable , switches, sockets, holders etc as per suitable size and capacity at site complete all as specified and directed. (Note - (a) items such as switches, sockets,holders, ceiling roses, tube light fitting, CFL fitting, ceiling light fitting , mirror light fitting, bulk head gitting etc shall be measured and paid under respective items of schedule.(b) Repairing up to four points at a time in one quarter will be measured as one complaint. |
| 40 | Supply and fix in repair/ replacement 09 Watt LED bollard light fiting for pathways and garden Cone/round, clear/ milky diffuser spun cover, die cast pole mounting, efficacy 95lm/watt, IP 65, module including fixing in concrete post suitable size GI pipe complete all as specified and directed. |